Page 581

Section 10A I/O Interface voltages on IN+ and IN-- terminals terminals must remain within ±20 Volts with respect to ANL COM for proper input channel operation. This is true for current and voltage input channel operation. voltage outputs (OUT 0 and OUT 1) are referenced to ANL COM. Load resistance (R1) for a voltage output channel must be equal to or greater than 1K ohms. current output channels (OUT 0 and OUT 1) source current that returns to ANL COM. Load resistance (R1) for a current output channel must remain between 0 and 500 ohms. input connections for single-ended or differential inputs are the same. ATTENTION: Before wiring any analog module, disconnect power from the chassis and from any other source to the analog module.

Grounding Your Cable Belden cable #8761 has two signal wires (black and clear), one drain wire and a foil shield. The drain wire and foil shield must be grounded at one end of the cable. Do not earth ground the drain wire and foil shield at both ends of the cable. Input Channel -- Ground the drain wire and foil shield near the sourcing device. Output Channel -- Use a rack mounting tab as a ground for the drain wire and foil shield. Important: If you cannot ground the input channel at the sourcing device, ground the drain wire and foil shield at the rack mounting tab. Do not connect the foil shield or drain wire to the analog terminal block. They must be connected to an earth ground, which is not provided at the analog module.

10A-58

Page 582

Section 10A I/O Interface

Analog Module NIO4V OUTPUT INPUT POWER

ANALOG

(0) IN 0+ (1) IN 0(2) ANL COM (3) IN 1+ (4) IN 1-

+ Analog source -

(0) IN 0+ (1) IN 0-

PE

(2) ANL COM (3) IN 1+ (4) IN 1-

(5) ANL COM

(5) ANL COM

(6) NOT USED

(6) NOT USED

(7) OUT 0

(7) OUT 0

(8) ANL COM

(8) ANL COM

(9) NOT USED

(9) NOT USED

(10) OUT 1

(10) OUT 1

(11)ANL COM

(11)ANL COM

Jumper unusedinputs

+ Analog Load Do not jumper unused outputs

PE

1746- NIO4V

Reading/Writing Analog Data The analog I/O module passes values to PAL through the I/O ring. The variable used to read/write the analog I/O module data is assigned using the PAL I/O assigner (refer to your 9/Series PAL Reference Manual for details). The following table shows the values of these PAL variables: Table 10A.AN Analog Input Decimal Values (to PAL) Voltage/Current Range

Decimal Representation

Number of Significant Bits

- 10V to + 10V (1LSB)

- 32,768 to + 32,767

16 bits

0V to 10 V (1LSB)

0 to 32,767

15 bits

0V to 5V

0 to 16,384

14 bits

1V to 5V

3,277 to 16,384

13.67 bits

- 20mA to +20mA

- 16,384 to +16,384

15 bits

0 to +20mA

0 to 16,384

14 bits

4 to +20 mA

3,277 to 16,384

13.67 bits

Resolution per LSB

305.176mV

1.22070mA

10A-59

Page 583

Section 10A I/O Interface

To determine an approximate voltage that an input value represents, use one of the following equations: 10 V (input value) = input voltage (V) 32,768 or for current 20 mA ( input value) = input voltage (V) 16,384 For example, if an input value of - 16,021 is in the input image, the calculated input voltage is: 10 V (- 16,021) = - 4.889221 V 32,768

This is the calculated value. The actual value may vary within the accuracy limitations of the module.

Table 10A.AO Analog Output Decimal Values (from PAL) Voltage/Current Range

Decimal Representation

Number of Significant Bits

- 10V to + 10V (1 LSB)

- 32,768 to + 32,767

14 bits

0V to 10 V (1 LSB)

0 to 32,767

13 bits

0V to 5V

0 to 16,384

12 bits

1V to 5V

3,277 to 16,384

11.67 bits

0 to +21mA

0 to +32,764

13 bits

0 to +20mA

0 to 31,208

12.92 bits

4 to +20 mA

6,242 to 31,208

12.6 bits

Resolution per LSB 1.22070mV

2.56348mA

To determine a value for the PAL variable of an analog output to produce a desired output, use one of the following equations: 32,768 (desired voltage output V) = output decimal value 10 V dc or for current 32,768 ( desired current output mA) = output decimal value 21 mA For example, if an output voltage of +1 V dc is desired, the value to be put in the corresponding PAL variable would be: 32,768 10V dc

10A-60

(+1V dc) = 3277

Page 584

Section 10A I/O Interface

10A.8.1 Analog I/O Specifications (1746-NIO4V)

Features High resolution -- 16 bit input and 14 bit output converters provide accurate control capabilities. Backplane powered -- No external power supply required, reducing system cost. User selectable inputs -- Configurable per channel for current or voltage inputs. Input channel filtering -- Rejects high frequency noise that couples into an analog input signal. Image maps directly into the 1746I adapter. Isolation -- All analog modules are isolated from each other and from the backplane. Description

Specification

Input Channels per Module

2 differential, voltage or current selectable per channel

Output Channels per Module

2 voltage outputs, not individually isolated

Backplane Current Draw

55mA at 5V dc 115mA at 24 V dc

Communication Format

16 bit Two’s Complement Binary

Field Wiring to Backplane Isolation

500 V dc

Conversion Time

512ms for all channels in parallel

Current/Voltage Ranges NIO4V

±10 V dc or ±20 mA (input) ±10 V dc (output)

Step Response Input Output

60 ms at 95% 2.5 ms at 95%

Maximum Wire Size

#14 AWG

Terminal Block

Removable

Noise Immunity

NEMA Standard ICS 2-230

Environmental Conditions Operating temperature Storage temperature Humidity rating

0 to +60°C (+32°to +140°F) - 40°C to +85°C (- 40°to +185°F) 5 to 95% (noncondensing)

Recommended Cable

Belden #8761

Certification

UL 508 listed, CSA 22.2 142 approved

Hazardous Environment Classification

Class I, Division 2 Hazardous Environment

10A-61

Page 585

Section 10A I/O Interface

10A.9 1746 I/O Fault Status

If the 9/Series fiber optic I/O ring should fault or any other fault should occur within the 1746 I/O rack, the 1746I module will attempt to maintain all of its I/O in the same state condition. This holds all output devices in the chassis to their present state. (Outputs already ON remain ON, outputs already OFF remain OFF, and analog modules maintain their present output voltage). Wire your I/O devices accordingly considering all safety issues.

10A.9.1 Troubleshooting the 1746I Communication Module

This section provides diagnostic information for troubleshooting your 1746 I/O chassis using the LED’s on the front of the 1746I module. Also in this section is information on using test modes to diagnose any problems with the fiber-optic connections. OFF This LED Status ON Flashing

10A-62

Indicates this possible cause:

Run LED On

·The I/O ring and the 1746 I/O rack are communicating properly and the rack is functioning.

Rack LED On

·RAM or ROM failure at power turn on. ·Device in rack failed or is not seated properly. ·Internal error in the 1746I adapter.

Rack LED Flashing

·A card type was found in the rack at power turn on that is not supported by the 1746I module.

Ring LED On

·Connection or device has failed in the I/O ring for a device before the 1746I in the ring. ·Power turned off at the CNC. ·Transmitter and receiver cables are reversed.

Ring LED Flashing

·Connection or device has failed in the I/O ring for a device after the 1746I in the ring.

All LEDs Off

·Power turned off at the CNC while the ring was up and running. ·Connection of I/O ring broken before this 1746I module while the ring was up and running.

Page 586

Section 10A I/O Interface

10A.10 Fast I/O (9/260 and 9/290 only)

The Fast I/O feature provides 4 inputs to and 4 outputs from the control. This feature is used to make changes in PAL that will take effect the next iteration of the PAL program. Using the fast I/O feature, the operator can input values to the PAL program using the PAL flag $HSIN and output values using the PAL flag $HSOUT. The fast I/O connector on the motherboard provides an interface port for fast input and output to and from the control. This connector interfaces with cable C11. Refer to page 7A-26 for additional information on cable C11. Figure 10A.40 and Table 10A.AP show the connector and its pin assignments. Figure 10A.40 Fast I/O Connector (has pins)

1

2

3

4

5

6

7

8

9 11

10 12

13

14

15

16

10A-63

Page 587

Section 10A I/O Interface

Table 10A.AP Pin Assignments for the Fast I/O Connector (P3) (Not available on the 9/230 and 9/440 control) Pin No.

Signal Name

Pin No.

Signal Name

1

FAST_I1

9

FAST_O1

2

COM

10

COM

3

FAST_I2

11

FAST_O2

4

COM

12

COM

5

FAST_I3

13

FAST_O3

6

COM

14

COM

7

FAST_I4

15

FAST_O4

8

COM

16

COM

Allen-Bradley recommends that you use the terminal blocks shown in Figure 10A.41 to simplify the wiring between your control and the fast I/O. The fast I/O cable connects to the connector on the block. Use the pin assignments in Table 10A.AP to wire the terminal connections. Figure 10A.41 Recommended Terminal Blocks for Fast I/O Wiring

19203

Weidmueller RI-16 Idc R (rail-mounted) Cat. No. 914892 Weidmueller RI-16 Idc P (panel-mounted) Cat. No. 914903

10A-64

19204

Phoenix FLKM 16 Order No. 22 81 02 1

Page 588

Section 10A I/O Interface

Figure 10A.42 shows the fast I/O circuit. Figure 10A.42 Fast I/O Circuit (Not available on the 9/230 control) +5 V 1K F38

Fast I/O Output

+5 V 1.8K Fast I/O Input

PE

PE

Table 10A.AQ lists the input specifications for the fast I/O. Table 10A.AQ Fast I/O Input Specifications Item

Specification

Remark

Maximum Input Current - Low

IIL = 6mA/input

Source

Maximum Input Voltage - Low

VIL = 0.45V/input

-

Table 10A.AR lists the output specifications for the fast I/O. Table 10A.AR Fast I/O Output Specifications Not available on the 9/230 control Item

Specification

Remark

Minimum Output Voltage - High

VOH = 4.25V/output

-

Minimum Output Current - High

IOH = 300mA/output

Source

Maximum Output Voltage - Low

VOL = 0.5V/output

-

Maximum Output Current - Low

IOL = 13mA/output

Sink

10A-65

Page 589

Section 10A I/O Interface

10A.11 Wiring I/O Safely

Many safety issues present themselves to the machine tool builder when wiring I/O devices. Typically, 9/Series I/O devices attempt to maintain their current status in the event of a system failure, I/O ring fault, or E-STOP condition. Make sure that this is a safe state for your machine by following these guidelines. Make sure I/O is wired so power failure places the device in a safe condition. For example if an output point controls an axis brake, you would typically want the brake applied when the I/O device fails or loses power. Make sure I/O is wired so E-STOP condition places the device in a safe condition. Remember E-STOP conditions do not reset I/O devices. I/O devices attempt to maintain their last state when E-STOP occurred. For example if an output point controls an axis brake, you would typically want the brake applied when the E-STOP condition occurs. Brake Circuit When R1-1 is closed brake is released. If E-STOP string is broken, brake is engaged.

R1- 1

R2- 1 L2 (L)

L1 (H)

Customer supplied brake relay

R1

R2

Energizes Brake Relay E-STOP String PB2 Terminal Block COM

COM

A01

COM COM

A02 A03

B01 B02

A04

A05 A06 A07

B03 B04 B05

B06

A08 B07

A09

A10 COM

B08 B09

B10

Label

COM

Important: Notice in the above figure the E-STOP string only kills power to the terminal blocks of the I/O module which in turn de-energizes the brake relay. The actual I/O module on the I/O ring remains powered. Killing power to the I/O device itself while the fiber optic ring is still running can cause I/O ring fault errors.

END OF SECTION

10A-66

Page 590

Section

10B

9/Series Adapter Modules for 1771 and 1746 I/O Devices

10B.0 Section Overview

This section discusses using I/O adapter modules for the 9/Series I/O ring. These adapter modules allow you to use Allen-Bradley’s 1746 I/O or 1771 I/O modules in the 9/Series I/O ring. This is accomplished by placing an adapter module in the I/O chassis that will interface to the 9/Series fiber optic I/O ring. These modules always reside in the first slot of the I/O chassis and replace the logic controller CPU or ASB adapter module that would typically reside in the first slot. 1771 Series B I/O Chassis 1746 Series B I/O Chassis

1771 XIOC adapter module

10B.1 1771 I/O Ring Adapter Module

1746I adapter module

Use the 1771 I/O Ring Adapter Module to interface an Allen-Bradley 1771 series B I/O chassis with the control. The 1771 I/O ring adapter module provides the system installer with the option of using a 1771 series B I/O chassis for discrete inputs and discrete outputs to the control (only discrete I/O cards are compatible with the 1771 adapter module). Use page 10B-10 to calculate how many ASRN chips are required for each I/O chassis. The adapter module must be placed in the first slot of the 1771 series B I/O chassis. The 1771 series B I/O chassis is then interfaced with the fiber-optic I/O ring of the control using the fiber optic connectors on the adapter module. Refer to the Allen-Bradley 1771 I/O Ring Adapter Module Product Data Sheet, publication 8500-4.5.1, for additional information on this module. No more than 16 1771 I/O adapter modules can exist on the 9/Series I/O ring.

10B-1