Ashcroft B-Series catalog of pressure, differential pressure and temperature switches: ranges, switch elements, ordering codes.
What this file really is
The old site listed this file as a manual for the Ashcroft B424B. The file is named as a user manual, but the document is a product catalog (Bulletin SW-10) for Ashcroft B-Series pressure, differential pressure and temperature switches.
Filed under · 1 model
Filed under these models in the old catalog
Summary
What is in it
A product catalog for Ashcroft B-Series pressure, differential pressure, vacuum and temperature switches. It describes the type 400 watertight and type 700 explosion-proof enclosures, the actuators, nominal ranges, deadbands and proof pressures, the switch element choices and their electrical ratings, how to build a model number (enclosure, switch element, actuator seal, options, range), optional features such as limit controls and fire-safe actuators, thermowells, and a guide to selecting a switch with a glossary of switch terms.
From the manual
Key facts from this manual
Each line names its page in the PDF.
Ashcroft Bulletin SW-10, a catalog of B-Series pressure, differential pressure and temperature switches in type 400 watertight and type 700 enclosures. It gives pressure ranges and deadbands, the model number scheme (enclosure, switch element, actuator seal, options, range), selection and application advice, and type 400 dimensions; B424B appears as an ordering example.
- Enclosure code B4
- Pressure switch, type 400, watertight enclosure meeting NEMA 3, 4, 4X, 13 and IP66 p. 5
- Switch element 24
- The standard switch element p. 5
- Actuator seal B
- Buna-N p. 5
- Actuator
- Diaphragm-sealed piston for setpoints of 2 to 3000 psi; large diaphragm for 4.5 to 150 inches of H2O p. 4
- Repeatability
- ±1 percent of range; proof pressure at least 400 percent of range p. 4
- Setting range
- About 15% to 100% of the nominal range p. 13
- Contacts
- SPDT snap acting; fine silver for 8 volts or more, gold alloy optional below 8 volts p. 13
- Type 400 ratings
- Snap-action switch with ratings up to 10A dc or 20A ac p. 2
- Electrical connection
- 3/4 NPT p. 2
- Pressure connection
- psi ranges 316 SS; psid ranges nickel-plated brass; inches of water ranges epoxy-coated carbon steel p. 2
- Enclosure build
- Type 400: epoxy-coated aluminum with neoprene gasket p. 2
- Ambient temperature
- –20 to 150°F, all styles; setpoint shift of ±1% of range per 50°F is normal p. 5
- Factory setting
- Option XFS, set to ±1% of the nominal range p. 13
- Mounting
- Any position p. 12
What this manual walks you through
- Pressure ranges, overpressure ratings and approximate deadbands by switch element p. 4
- Building a B-Series pressure switch model number p. 5
- Choosing optional features and accessories p. 9
- Selecting the actuator, enclosure, switching function and switch element p. 10, 11
- Switch terms such as deadband, proof pressure and repeatability p. 11
- Applying switches to difficult media, steam, high temperature, vibration and pulsation p. 12
- Ordering a factory-set switch (XFS) p. 13
- Type 400 dimensions p. 14
Good to know
- Pressures above the nominal range can permanently damage the switch. p. 11
- For steam, a water-filled siphon belongs between the switch and the process line. p. 12
- Above 300°F process temperature, four feet of 1/2 inch tubing between process and switch generally protects it. p. 12
- Severe vibration may cause premature tripping, roughly 5% to 10% of range from the setpoint. p. 12
- Buna N cannot be cleaned for oxygen service. p. 9
Questions this manual answers
What does the Ashcroft model number B424B mean?
In the model number tables, B4 is a type 400 watertight pressure switch, 24 is the standard switch element, and B is a Buna-N actuator seal. p. 5, 13
How do I order a B424B set at the factory?
Add option XFS and give the setpoint and whether it trips on increasing or decreasing pressure, for example B424B XFS 100# Set: 60# decreasing. p. 13
What range can an Ashcroft B-Series pressure switch be set over?
About 15% to 100% of the nominal range. p. 13
Can the B-Series switch be used on steam?
Yes, with a water-filled siphon between switch and process line; the catalog recommends the stainless steel welded connection and diaphragm. p. 12
Does the B-Series switch have to be mounted upright?
No, switches with snap acting contacts may be mounted in any position. p. 12