Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of B-Series Switches: Pressure, Differential Pressure, Temperature

Manual · Ashcroft

B-Series Switches: Pressure, Differential Pressure, Temperature

Manual16 pagesPDF 1.1 MB

Ashcroft B-Series catalog of pressure, differential pressure and temperature switches: ranges, switch elements, ordering codes.

What this file really is

The old site listed this file as a manual for the Ashcroft B424B. The file is named as a user manual, but the document is a product catalog (Bulletin SW-10) for Ashcroft B-Series pressure, differential pressure and temperature switches.

Download the PDF1.1 MB

Filed under · 1 model

Filed under these models in the old catalog

Summary

What is in it

A product catalog for Ashcroft B-Series pressure, differential pressure, vacuum and temperature switches. It describes the type 400 watertight and type 700 explosion-proof enclosures, the actuators, nominal ranges, deadbands and proof pressures, the switch element choices and their electrical ratings, how to build a model number (enclosure, switch element, actuator seal, options, range), optional features such as limit controls and fire-safe actuators, thermowells, and a guide to selecting a switch with a glossary of switch terms.

From the manual

Key facts from this manual

Each line names its page in the PDF.

Ashcroft Bulletin SW-10, a catalog of B-Series pressure, differential pressure and temperature switches in type 400 watertight and type 700 enclosures. It gives pressure ranges and deadbands, the model number scheme (enclosure, switch element, actuator seal, options, range), selection and application advice, and type 400 dimensions; B424B appears as an ordering example.

Read for this summary: pages 1 to 5, 9 to 14 and 16 of 16.

Enclosure code B4
Pressure switch, type 400, watertight enclosure meeting NEMA 3, 4, 4X, 13 and IP66 p. 5
Switch element 24
The standard switch element p. 5
Actuator seal B
Buna-N p. 5
Actuator
Diaphragm-sealed piston for setpoints of 2 to 3000 psi; large diaphragm for 4.5 to 150 inches of H2O p. 4
Repeatability
±1 percent of range; proof pressure at least 400 percent of range p. 4
Setting range
About 15% to 100% of the nominal range p. 13
Contacts
SPDT snap acting; fine silver for 8 volts or more, gold alloy optional below 8 volts p. 13
Type 400 ratings
Snap-action switch with ratings up to 10A dc or 20A ac p. 2
Electrical connection
3/4 NPT p. 2
Pressure connection
psi ranges 316 SS; psid ranges nickel-plated brass; inches of water ranges epoxy-coated carbon steel p. 2
Enclosure build
Type 400: epoxy-coated aluminum with neoprene gasket p. 2
Ambient temperature
–20 to 150°F, all styles; setpoint shift of ±1% of range per 50°F is normal p. 5
Factory setting
Option XFS, set to ±1% of the nominal range p. 13
Mounting
Any position p. 12

What this manual walks you through

  • Pressure ranges, overpressure ratings and approximate deadbands by switch element p. 4
  • Building a B-Series pressure switch model number p. 5
  • Choosing optional features and accessories p. 9
  • Selecting the actuator, enclosure, switching function and switch element p. 10, 11
  • Switch terms such as deadband, proof pressure and repeatability p. 11
  • Applying switches to difficult media, steam, high temperature, vibration and pulsation p. 12
  • Ordering a factory-set switch (XFS) p. 13
  • Type 400 dimensions p. 14

Good to know

  • Pressures above the nominal range can permanently damage the switch. p. 11
  • For steam, a water-filled siphon belongs between the switch and the process line. p. 12
  • Above 300°F process temperature, four feet of 1/2 inch tubing between process and switch generally protects it. p. 12
  • Severe vibration may cause premature tripping, roughly 5% to 10% of range from the setpoint. p. 12
  • Buna N cannot be cleaned for oxygen service. p. 9

Questions this manual answers

What does the Ashcroft model number B424B mean?

In the model number tables, B4 is a type 400 watertight pressure switch, 24 is the standard switch element, and B is a Buna-N actuator seal. p. 5, 13

How do I order a B424B set at the factory?

Add option XFS and give the setpoint and whether it trips on increasing or decreasing pressure, for example B424B XFS 100# Set: 60# decreasing. p. 13

What range can an Ashcroft B-Series pressure switch be set over?

About 15% to 100% of the nominal range. p. 13

Can the B-Series switch be used on steam?

Yes, with a water-filled siphon between switch and process line; the catalog recommends the stainless steel welded connection and diaphragm. p. 12

Does the B-Series switch have to be mounted upright?

No, switches with snap acting contacts may be mounted in any position. p. 12

The whole text · 2 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 81-8
  2. Pages 9 to 169-16

The file

Revision and size

RevisionBulletin SW-10
PublisherDresser Control Instrument Operation
Pages16
PDF1.1 MB
TextText from the PDF itself.

The first pages · 3 of 16

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 16
Page 2
Page 2of 16
Page 3
Page 3of 16

More documents · 1