Page 41

E362

Rucl ang

-

The last subgroup range angle value is larger than the upper control limit.

E363

Rlcl ang

-

The last subgroup range angle value is lower than the lower control limit.

E364

Cp ang

-

The angle Cp is lower than 2.

E365

Cpk ang

-

The angle Cpk is lower than 1,33.

E366

7inc x ang

-

Trend deviation alarm, the subgroup angle mean value has increased 7 times consecutively.

E367

7dec x ang

-

Trend deviation alarm, the subgroup angle mean value has decreased 7 times consecutively.

E368

7inc r ang

-

Trend deviation alarm, the subgroup angle range value has increased 7 times consecutively.

E369

7dec r ang

-

Trend deviation alarm, the subgroup angle mean value has decreased 7 times consecutively.

E370

7above x ang

-

Trend deviation alarm, the subgroup angle mean value has been above the average mean value of the average of the last ten subgroups 7 times consecutively.

E371

7below x ang

-

Trend deviation alarm, the subgroup angle mean value has been below the average mean value of the average of the last ten subgroups 7 times consecutively.

E372

7above r ang

-

Trend deviation alarm, the subgroup angle range value has been above the average range value of the average of the last ten subgroups 7 times consecutively.

E373

7below r ang

-

Trend deviation alarm, the subgroup angle range value has been below the average range value of the average of the last ten subgroups 7 times consecutively.

E374

2sigma x ang

-

Trend deviation alarm, the last subgroup angle average is outside Xang-bar-bar – 2 sigma.

E375

2sigma r ang

-

Trend deviation alarm, the last subgroup angle range average is outside Rang-bar-bar – 2 sigma.

41

Page 42

E400-E499: Communication errors E401

Duplicate device IDs on IO bus

Yes

Two IO devices with the same ID are present on the I/O bus.

E402

IO bus restarted

Yes

The IO bus has been restarted.

E403

IO device not responding

Yes

The I/O device is not properly connected or the ID of the device is not the same as the one configured.

E404

Selector is not connected or not responding

Yes

The selector is not properly connected or the ID of the selector is not the same as the one configured.

E405

IO Expander is not connected or not responding

Yes

The I/O expander is not properly connected or the ID of the I/O expander is not the same as the one configured.

E406

RE-alarm is not connected or not responding

Yes

The Remote alarm is not properly connected or the ID of the Remote alarm is not the same as the one configured.

E408

Multiple devices of same type on IO bus

-

E409

Multiple selectors on IO bus

-

E410

No selector found and Pset source is IO bus

-

E411

Rotary selector has ID <> 1

-

E412

IO expander has ID <> 2

-

E413

RE Alarm has ID <> 3

-

E414

Remote display has ID <> 4

-

E415

4socket selector has ID <> 5

-

E416

8socket selector has ID <> 6

-

E433

No RBU present

Yes

E434

RBU Timeout

Yes

RBU did not respond to command from PF.

E438

RBU file mismatch

Yes

A file with incorrect name or size was returned to a read request.

E439

RBU signal mismatch

Yes

An unexpected signal received by the RBU Manager in Idle status.

E440

RBU no files

Yes

No RBU detected at start-up or RBU found missing at runtime.

42

Page 43

E441

RBU no answer

Yes

E442

RBU no such file

Yes

E443

RBU full

Yes

E444

RBU packet rejected

Yes

E445

RBU corrupt

Yes

E446

RBU read error

Yes

E447

RBU write error

Yes

E448

RBU delete error

Yes

E449

RBU flush error

Yes

E450

RBU list error

Yes

E451

RBU Update Failed

Yes

E460

FieldBus Type Mailbox Message Fault

-

E461

FieldBus Type Gen Com Fault

-

E462

FieldBus Mailbox Message Fault

-

E463

FieldBus Gen Com Fault

-

E464

FieldBus Hardware Fault

Yes

The FieldBus module is broken and has to be replaced.

E465

FieldBus Dip switch Error

-

The software tries to configure the value of node address or baudrate, But the address switch on the FieldBus module is not in the right position to enable software setting. Set switches in the right position, then turn on the power.

E466

FieldBus Offline

-

E467

FieldBus Configuration Fault

-

E468

FieldBus Hardware Mismatch

-

E469

FieldBus Init Error

-

E470

FieldBus PCP error

-

RBU responds with an answer not matching the last request. This is probably due to duplicates sent when the PF does not acknowledge packages.

RBU Erase failed.

One of the database processes failed to synchronise the NVRAM with the RBU.

The FieldBus went from Online to Offline. This is just a warning.

The FieldBus module installed in PF 3000 is not the same FieldBus type as configured with TTPF. Change FieldBus module or configuration to get a match.

43

Page 44

E480

Channel ID not valid

Yes

The channel ID configured is not within the limits permitted. The channel ID must configured between 1 and 20.

E481

Cell member registration failed

Yes

The cell member registration failed because one cell member is already registered with the same channel ID.

E490

Cell ID not valid

Yes

The cell ID configured is not within the limits permitted. The cell ID must configured between 1 and 999.

E491

Net member registration failed

-

The net member registration failed because one net member is already registered with the same cell ID.

E492

Software version not compatible with net-cell

Yes

It is not possible to build a net with two different revisions of the software.

E500-E599: Hardware errors TOOL E501

Tool overheated

-

E502

Tool service interval expired

-

The tool is too hot. The drive is disabled.

E511

Tool-PF3000 size mismatch

Yes

Mismatch between the tool and the controller (for example S4/S7 tool connected to a S9 controller).

E512

Tool revision not supported by this drive SW

Yes

The tool is not supported by the drive (drive version too old).

E513

Tool EEPROM corrupt – service tool

Yes

E514

Tool EEPROM corrupt – Motortune

Yes

E515

Tool commutation sensor error

Yes

Commutation sensor failure.

E516

Rotor magnet remains out of range

Yes

Rotor magnet remains out of range.

E517

Tool maxtorque or Gear Ratio out of range

Yes

E518

Tool normalisation out of range

-

E534

Illegal data error (Current monitoring)

Yes

44

Page 45

E535

Torque transducer error

Yes

Cables to transducer cut off or shorted.

E536

No transducer (sensor)

Yes

Cables to transducer cut off or shorted.

E537

Calibration not OK, offset outside limits

Yes

Calibration limits out of bounds.

E538

Calibration not OK, CalVal outside limits

Yes

Calibration value outside limits.

E539

Calibration not OK, Offset changed > 5% of max value since last calibration

-

Calibration not OK, Offset changed > 5% of max value since last calibration.

E540

Calibration not OK, CalVal changed > 5% of max value since last calibration

-

Calibration not OK, calibration value changed > 5% of max value since last calibration.

E541

Other calibration error

Yes

E600-E699: Hardware errors DC3000/MC3000 E601

Dcbus LO at start of rundown

Yes

DC voltage too low

E602

Dcbus HI during rundown

Yes

DC voltage too high

E603

DC3000 overheated

-

The drive is too hot, drive disabled

E604

24V output error

Yes

24 V output disabled (overload or short circuit)

E605

Dcbus HI at start of rundown

-

E611

DC3000 EEPROM corrupt (csum error)

Yes

E612

MC3000 EEPROM corrupt (csum error)

Yes

E613

Config1 EEPROM corrupt (csum error)

Yes

E614

FirmWare corrupt (csum error etc)

Yes

E615

Option definition HW/ SW mismatch

Yes

E616

Current measurement offset error

Yes

Firmware corrupt (check sum error)

45

Page 46

E617

Current measurement gain error

Yes

E633

SW mismatch CC <-> MC: Too old MC SW

Yes

E634

SW mismatch CC <-> MC: Too old CC SW

Yes

E700-E799: Hardware errors E700

PF started

-

This error code is only visible in the error log and used when the PF3000 is started.

E800-E899: Software errors E801

Database incompatible with PF software

Yes

E802

NVRAM range check error

Yes

E803

NVRAM size check error

Yes

E804

Database is corrupt

Yes This error is displayed after start-up when the RBU is missing, or when the RBU revision cannot be supported by the controller (e.g bronze RBU on a graph unit), or when the RBU license file is missing or cannot be read by the boot code.

E805

(PF Model unknown)

Yes

E806

Failed to read from NVRAM

-

E807

Failed to write to NVRAM

-

E811

DPRAM range check error

Yes

E821

No calibration ACC from control

Yes

Tightening initialisation phase failed. Hardware failure.

E822

No Job ACC from control

Yes

Tightening initialisation phase failed. Hardware failure.

E823

No calibration result

Yes

No calibration was received from the drive during the tightening initialisation phase (timeout 100 ms).

E824

Cycle abort timeout

-

No tightening result was received from the drive before the Cycle abort timeout. The Cycle Abort timer is configurable in the Pset.

E831

Autoset wrong angle

-

Auto set could not be executed, the angle results of the tightening performed were null.

46

Page 47

E832

Autoset small angle

-

Auto set could not be executed, the angle results of the tightening performed were too small (lower than 15 degrees).

E833

Autoset tight NOK result

-

The Auto set could not be executed, four NOK tightenings were performed.

E834

Autoset rejected Pset in CCW direction

-

The Auto set was not allowed by the PF3000 for this Pset because the Pset was configured in the CCW direction. Auto set is only permitted on CW Pset.

E840

Feature Not Available In Software Revision

E851

Connection with Tools Net server lost

E855

Connection fatal error

E856

Router unreachable

The router programmed in the configuration setting could not be reached. Check the network configuration and in particularly the sub net mask and the default router.

E857

Reboot needed before changes take effect

The configuration changes will not take effect before a system reboot.

E858

IP address already in use

Yes

The IP address of this PF3000 is already in use by another system.

E859

IP address collision

-

Another system attempts to use the same IP address as this PF3000.

E860

Memory Allocation Error

-

It was not possible to allocate enough memory to allow the Tools Net process to set a result subscription.

E862

Ethernet overload Error

E863

IP Port already in use

This error is displayed if when attempt is made to run multistage with a bronze version, or handle a Pset with a Pset ID larger than the max number of Pset (larger than 64 in a bronze version or larger than 250 in a silver or gold version). -

The connection with the Tools Net server was lost, the PF3000 is trying to reconnect. The Tools Net server might be down or it might be an Ethernet cable problem.

The Ethernet driver of the PF3000 is switched off due to an overloaded network. Yes

An attempt was made to bind a TCP or UDP socket to a port already in use. For instance, a customer protocol might be using the same port as ToolsTalk.

47

Page 48

2005:1 9833 1431 01