Page 41
E362
Rucl ang
-
The last subgroup range angle value is larger than the upper control limit.
E363
Rlcl ang
-
The last subgroup range angle value is lower than the lower control limit.
E364
Cp ang
-
The angle Cp is lower than 2.
E365
Cpk ang
-
The angle Cpk is lower than 1,33.
E366
7inc x ang
-
Trend deviation alarm, the subgroup angle mean value has increased 7 times consecutively.
E367
7dec x ang
-
Trend deviation alarm, the subgroup angle mean value has decreased 7 times consecutively.
E368
7inc r ang
-
Trend deviation alarm, the subgroup angle range value has increased 7 times consecutively.
E369
7dec r ang
-
Trend deviation alarm, the subgroup angle mean value has decreased 7 times consecutively.
E370
7above x ang
-
Trend deviation alarm, the subgroup angle mean value has been above the average mean value of the average of the last ten subgroups 7 times consecutively.
E371
7below x ang
-
Trend deviation alarm, the subgroup angle mean value has been below the average mean value of the average of the last ten subgroups 7 times consecutively.
E372
7above r ang
-
Trend deviation alarm, the subgroup angle range value has been above the average range value of the average of the last ten subgroups 7 times consecutively.
E373
7below r ang
-
Trend deviation alarm, the subgroup angle range value has been below the average range value of the average of the last ten subgroups 7 times consecutively.
E374
2sigma x ang
-
Trend deviation alarm, the last subgroup angle average is outside Xang-bar-bar – 2 sigma.
E375
2sigma r ang
-
Trend deviation alarm, the last subgroup angle range average is outside Rang-bar-bar – 2 sigma.
41
Page 42
E400-E499: Communication errors E401
Duplicate device IDs on IO bus
Yes
Two IO devices with the same ID are present on the I/O bus.
E402
IO bus restarted
Yes
The IO bus has been restarted.
E403
IO device not responding
Yes
The I/O device is not properly connected or the ID of the device is not the same as the one configured.
E404
Selector is not connected or not responding
Yes
The selector is not properly connected or the ID of the selector is not the same as the one configured.
E405
IO Expander is not connected or not responding
Yes
The I/O expander is not properly connected or the ID of the I/O expander is not the same as the one configured.
E406
RE-alarm is not connected or not responding
Yes
The Remote alarm is not properly connected or the ID of the Remote alarm is not the same as the one configured.
E408
Multiple devices of same type on IO bus
-
E409
Multiple selectors on IO bus
-
E410
No selector found and Pset source is IO bus
-
E411
Rotary selector has ID <> 1
-
E412
IO expander has ID <> 2
-
E413
RE Alarm has ID <> 3
-
E414
Remote display has ID <> 4
-
E415
4socket selector has ID <> 5
-
E416
8socket selector has ID <> 6
-
E433
No RBU present
Yes
E434
RBU Timeout
Yes
RBU did not respond to command from PF.
E438
RBU file mismatch
Yes
A file with incorrect name or size was returned to a read request.
E439
RBU signal mismatch
Yes
An unexpected signal received by the RBU Manager in Idle status.
E440
RBU no files
Yes
No RBU detected at start-up or RBU found missing at runtime.
42
Page 43
E441
RBU no answer
Yes
E442
RBU no such file
Yes
E443
RBU full
Yes
E444
RBU packet rejected
Yes
E445
RBU corrupt
Yes
E446
RBU read error
Yes
E447
RBU write error
Yes
E448
RBU delete error
Yes
E449
RBU flush error
Yes
E450
RBU list error
Yes
E451
RBU Update Failed
Yes
E460
FieldBus Type Mailbox Message Fault
-
E461
FieldBus Type Gen Com Fault
-
E462
FieldBus Mailbox Message Fault
-
E463
FieldBus Gen Com Fault
-
E464
FieldBus Hardware Fault
Yes
The FieldBus module is broken and has to be replaced.
E465
FieldBus Dip switch Error
-
The software tries to configure the value of node address or baudrate, But the address switch on the FieldBus module is not in the right position to enable software setting. Set switches in the right position, then turn on the power.
E466
FieldBus Offline
-
E467
FieldBus Configuration Fault
-
E468
FieldBus Hardware Mismatch
-
E469
FieldBus Init Error
-
E470
FieldBus PCP error
-
RBU responds with an answer not matching the last request. This is probably due to duplicates sent when the PF does not acknowledge packages.
RBU Erase failed.
One of the database processes failed to synchronise the NVRAM with the RBU.
The FieldBus went from Online to Offline. This is just a warning.
The FieldBus module installed in PF 3000 is not the same FieldBus type as configured with TTPF. Change FieldBus module or configuration to get a match.
43
Page 44
E480
Channel ID not valid
Yes
The channel ID configured is not within the limits permitted. The channel ID must configured between 1 and 20.
E481
Cell member registration failed
Yes
The cell member registration failed because one cell member is already registered with the same channel ID.
E490
Cell ID not valid
Yes
The cell ID configured is not within the limits permitted. The cell ID must configured between 1 and 999.
E491
Net member registration failed
-
The net member registration failed because one net member is already registered with the same cell ID.
E492
Software version not compatible with net-cell
Yes
It is not possible to build a net with two different revisions of the software.
E500-E599: Hardware errors TOOL E501
Tool overheated
-
E502
Tool service interval expired
-
The tool is too hot. The drive is disabled.
E511
Tool-PF3000 size mismatch
Yes
Mismatch between the tool and the controller (for example S4/S7 tool connected to a S9 controller).
E512
Tool revision not supported by this drive SW
Yes
The tool is not supported by the drive (drive version too old).
E513
Tool EEPROM corrupt – service tool
Yes
E514
Tool EEPROM corrupt – Motortune
Yes
E515
Tool commutation sensor error
Yes
Commutation sensor failure.
E516
Rotor magnet remains out of range
Yes
Rotor magnet remains out of range.
E517
Tool maxtorque or Gear Ratio out of range
Yes
E518
Tool normalisation out of range
-
E534
Illegal data error (Current monitoring)
Yes
44
Page 45
E535
Torque transducer error
Yes
Cables to transducer cut off or shorted.
E536
No transducer (sensor)
Yes
Cables to transducer cut off or shorted.
E537
Calibration not OK, offset outside limits
Yes
Calibration limits out of bounds.
E538
Calibration not OK, CalVal outside limits
Yes
Calibration value outside limits.
E539
Calibration not OK, Offset changed > 5% of max value since last calibration
-
Calibration not OK, Offset changed > 5% of max value since last calibration.
E540
Calibration not OK, CalVal changed > 5% of max value since last calibration
-
Calibration not OK, calibration value changed > 5% of max value since last calibration.
E541
Other calibration error
Yes
E600-E699: Hardware errors DC3000/MC3000 E601
Dcbus LO at start of rundown
Yes
DC voltage too low
E602
Dcbus HI during rundown
Yes
DC voltage too high
E603
DC3000 overheated
-
The drive is too hot, drive disabled
E604
24V output error
Yes
24 V output disabled (overload or short circuit)
E605
Dcbus HI at start of rundown
-
E611
DC3000 EEPROM corrupt (csum error)
Yes
E612
MC3000 EEPROM corrupt (csum error)
Yes
E613
Config1 EEPROM corrupt (csum error)
Yes
E614
FirmWare corrupt (csum error etc)
Yes
E615
Option definition HW/ SW mismatch
Yes
E616
Current measurement offset error
Yes
Firmware corrupt (check sum error)
45
Page 46
E617
Current measurement gain error
Yes
E633
SW mismatch CC <-> MC: Too old MC SW
Yes
E634
SW mismatch CC <-> MC: Too old CC SW
Yes
E700-E799: Hardware errors E700
PF started
-
This error code is only visible in the error log and used when the PF3000 is started.
E800-E899: Software errors E801
Database incompatible with PF software
Yes
E802
NVRAM range check error
Yes
E803
NVRAM size check error
Yes
E804
Database is corrupt
Yes This error is displayed after start-up when the RBU is missing, or when the RBU revision cannot be supported by the controller (e.g bronze RBU on a graph unit), or when the RBU license file is missing or cannot be read by the boot code.
E805
(PF Model unknown)
Yes
E806
Failed to read from NVRAM
-
E807
Failed to write to NVRAM
-
E811
DPRAM range check error
Yes
E821
No calibration ACC from control
Yes
Tightening initialisation phase failed. Hardware failure.
E822
No Job ACC from control
Yes
Tightening initialisation phase failed. Hardware failure.
E823
No calibration result
Yes
No calibration was received from the drive during the tightening initialisation phase (timeout 100 ms).
E824
Cycle abort timeout
-
No tightening result was received from the drive before the Cycle abort timeout. The Cycle Abort timer is configurable in the Pset.
E831
Autoset wrong angle
-
Auto set could not be executed, the angle results of the tightening performed were null.
46
Page 47
E832
Autoset small angle
-
Auto set could not be executed, the angle results of the tightening performed were too small (lower than 15 degrees).
E833
Autoset tight NOK result
-
The Auto set could not be executed, four NOK tightenings were performed.
E834
Autoset rejected Pset in CCW direction
-
The Auto set was not allowed by the PF3000 for this Pset because the Pset was configured in the CCW direction. Auto set is only permitted on CW Pset.
E840
Feature Not Available In Software Revision
E851
Connection with Tools Net server lost
E855
Connection fatal error
E856
Router unreachable
The router programmed in the configuration setting could not be reached. Check the network configuration and in particularly the sub net mask and the default router.
E857
Reboot needed before changes take effect
The configuration changes will not take effect before a system reboot.
E858
IP address already in use
Yes
The IP address of this PF3000 is already in use by another system.
E859
IP address collision
-
Another system attempts to use the same IP address as this PF3000.
E860
Memory Allocation Error
-
It was not possible to allocate enough memory to allow the Tools Net process to set a result subscription.
E862
Ethernet overload Error
E863
IP Port already in use
This error is displayed if when attempt is made to run multistage with a bronze version, or handle a Pset with a Pset ID larger than the max number of Pset (larger than 64 in a bronze version or larger than 250 in a silver or gold version). -
The connection with the Tools Net server was lost, the PF3000 is trying to reconnect. The Tools Net server might be down or it might be an Ethernet cable problem.
The Ethernet driver of the PF3000 is switched off due to an overloaded network. Yes
An attempt was made to bind a TCP or UDP socket to a port already in use. For instance, a customer protocol might be using the same port as ToolsTalk.
47
Page 48
2005:1 9833 1431 01