The text of a manual · part 4 of 5
Power Focus Quick Guide, pages 31 to 40
Pages 31 to 40 of 48
The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Atlas Copco PF3007-C-HW and Atlas Copco PF3007-G-HW
Page 31
SYNCHRONISATION PROGRAMMING Software Setup 1) Make sure that all Power Focus units in the synchronised group are part of the same Cell (see cell programming). 2) Decide which units should act as Sync Reference and Sync Members according to HW setup. 3) For the Sync members: – Set Sync reference IP address in the appropriate field. – Set Tool start select source to Sync start. – Configure the 4-pin connector on the back panel for remote start. – Re-start the Sync Member. – Repeat step 1-4 for all Sync Members.
4) For the Sync reference: – Set Sync reference IP address equal to own IP address. – Create the Sync Group List and set other Sync options. – Re-start Sync Reference. – Pset programming, and I/O-setup is done only on the Sync Reference.
31
Page 32
MONITORING IN TOOLSTALK ToolsTalk provides a number of monitors designed to present extensive information about various functions of Power Focus. Among others are: Operator Monitor Detailed information about the tightening operation is presented.
Get all results Power Focus can store up to 5000 individual tightening results. With the Get All Results option, the user is able to retrieve and view these.
By choosing Save To File the results are saved into a text-file. The user can also choose to open and view the results in Microsoft Excel® by selecting Open In Excel.
32
Page 33
TRACES / STATISTICS These are three different ways to activate the traces: 1) Select Window in Main Row and then click on Activate->Trace. 2) Use the PF map. Double-click on Trace. 3) Use Trace icon in Toolbar. Click on the icon.
Statistics The statistic setup can be found under Pset – Statistic Programming. There you are able among others to program statistical alarms like SPC, etc.
33
Page 34
SERVICE SETUP Under Diagnostic – Configuration – Tool service, this window shows the service status of the tool.
Here you can see information about last service date and the number of tightenings after service. By turning the Service indicator alarm On, the Power Focus will automatically alert the user when the service interval has expired.
34
Page 35
EVENT CODES Event code
Group
Description
E000-E099
0
Rundown failures
E100-E199
1
Event-related errors
E200-E299
2
User input error
E300-E399
3
Statistical errors
E400-E499
4
Communication errors
E500-E599
5
Hardware errors TOOL
E600-E699
6
Hardware errors DC3000/MC3000
E700-E799
7
Hardware errors
E800-E899
8
Software errors
E900-E999
9
Errors MMI3000
Event Code
Event Text
Acknowledge
Explanation
E000-E099: Rundown errors E001
Torque LO
-
Start button was probably released to early. Let the tool «finish» the tightening.
E002
Torque HI
-
The programming is probably bad. Make sure that you have some movement on the socket in the second stage.
E003
Torque measurement possibly invalid
-
E004
Angle1 LO
-
E005
Angle1 HI
-
Check the programming or the joint
E006
Angle2 LO
-
Check the programming or the joint
E007
Angle2 HI
-
Check the programming or the joint
Check the programming or the joint
E100-E199: Event-related errors E101
Pset invalid (check sum error)
Yes
E102
Rundown prohibited due to Lock on Reject
-
This error code is displayed after a NOK tightening when the function Lock on Reject is activated. In this case the tool is disabled, the tool can be unlocked with a digital input or with the tool ring.
E103
Forward direction prohibited via digital input
-
The forward direction is prohibited via the digital input.
35
Page 36
E104
Reverse direction prohibited
-
The reverse direction is prohibited via digital input or in Job mode. The reverse direction is prohibited in job mode when Lock at Job Done is selected or batch mode is configured to NOK+OK.
E105
Reverse direction prohibited via ToolsTalk
-
The reverse direction is prohibited via Tools Talk.
E106
Rundown prohibited due to active CycleHold
-
The tool is locked due to Cycle hold.
E107
Rundown prohibited due to Line Control, batch not enabled
-
A job using Line Control is selected. The job does not start until Line Control Start signal is received.
E108
Rundown prohibited due to keypad usage
-
E109
Pset revision not supported by this SW
-
E110
Configuration revision not supported by this SW
-
E111
MC Rundown timeout
-
E112
Rehit
-
E113
Current limit reached – Rundown aborted
Yes
E114
OpenEnd Reference position not found
Yes
E115
Direction uncertain
-
E116
SelfTap max torque reached – Rundown aborted
-
E120
MC Motortuning failure
Yes
Motor tuning failed. The trigger could have been released before the end of the motor tuning or the tool has a defect.
E121
OpenEnd tuning failure
Yes
This error indicates that the open end tuning command has not been successfully performed. Either the command was aborted by the operator or the command could not be performed for any other reason.
E126
Multistage aborted
-
This error indicates that the current running multistage has not been performed entirely (the drive has been shut off or the tool trigger was released before the end).
The rundown was not terminated before the drive time out (2 minutes).
The current limit has been reached; the drive is disabled.
36
Page 37
E127
PVT shut off
-
This error indicates that the drive was shut off in the Self-tap or prevail phase of the rundown.
E128
Trigger lost
-
When the function Trigger lost is activated in the Pset, this error indicates that the trigger of the tool was released before final target.
E129
Torque lower than target
-
When the function torque lower than target is activated in the Pset, this error indicates that the torque result is below final target. The torque status is NOK even if the torque result was larger than final torque min.
E130
Post view torque shut off
E131
Tool Disconnected
This error indicates that the tool is not connected Yes to the controller or that the tool cable has been damaged.
E132
Wrong tool start input setting
1) Check if the remote start wiring in the PF is correctly set in accordance to the settings in the Yes Configuration parameters (C220). 2) Check if the tool trigger is constantly pressed or if there is some malfunction in the tool.
E133
Forward direction prohibited via ToolsTalk
-
The forward direction is prohibited via Tools Talk.
E134
MC Target input active at start attempt
-
The target signal is active in the drive though the tightening has been acknowledged by the CC-card.
E135
MC No start Ack from CC
-
No start acknowledgement has been received by the MC drive from the CC-card (timeout 32s)
E136
Rundown prohibited due to batch locked
-
This error is displayed if the function lock at batch OK is enabled and when the batch is completed. The tool can only be unlocked via a digital input.
E137
Rundown prohibited via field bus
-
The rundown is prohibited via field bus.
E138
Wrong tool start input source
-
It is only possible to start the tool from the selected tool start select source.
E139
Rundown prohibited via Open protocol
-
The rundown is prohibited via Open protocol.
E140
Insert user ID card to release tool
-
The tool is locked, the user must insert his ID card in the card reader to release the tool.
E141
MC Current Monitoring torque deviation
Yes
Post view torque conditions were not fulfilled.
37
Page 38
E142
MC SyncroTorque diffstop
-
E150
Job client does not respond
-
When running a Cell Job, this error is displayed by the job master when one of the job members does not respond.
E151
Job in OFF mode
-
It is not possible to select a new job, the PF3000 is in Job Off mode.
E152
PF locked in job mode
-
This error appears when in a forced cell job an attempt is made to tighten with a controller which is not currently active or when a controller has performed all tightenings.
E153
Not Ok to select new job
-
A job is currently running, it is not possible to select a new job until the first is finished in some way (completed or aborted). This message is also displayed if a job is selected on a job member.
E154
Remote job running
-
When running a Cell Job, this is displayed by the job members when a cell job is selected on the job master.
E155
Remote job aborted
-
When running a Cell Job, This is displayed by the job members when a cell job is aborted.
E156
Job members lost
-
When running a Cell Job, this is displayed by the master when it has lost contact with one of its job member.
E157
Job reference lost
-
When running a Cell Job, this is displayed by the job members when they have lost contact with their Job Master.
E158
Invalid Job ID
-
When the selected job does not exist.
E159
No Pset In Selected Job
-
When the selected job does not contain any Pset.
E160
Job select source not valid
-
Attempt to select a Job with the wrong input source.
E161
Line Control Alert 1
-
The line control has been activated, and the first control alert limit has been reached.
E162
Line Control Alert 2
-
The line control has been activated, and the second control alert limit has been reached.
E180
Euchner Ident System only supports Siemens 3964R protocol
-
The protocol settings for the serial COM port 1 is not set to 3964R, it is not possible to use the Euchner Ident System with this configuration.
E181
Not possible to read ID card
-
It was not possible to read the ID card inserted in the Euchner system.
38
Page 39
E200-E299: User input error E201
First target > Final target
-
E202
Final target > Tool max torque
-
E203
First target < XX % of tool max torque
-
E204
Final target < YY % of tool max torque
-
E205
Pset not open
-
E206
Pset number invalid
-
An attempt was made to do a tightening with the wrong Pset within a job.
E207
Wrong Pset Select Source
-
Attempt to select Pset from a source not specified in the Cset.
E208
Not Ok to select new Pset
-
It is not allowed to select new Pset when the already selected Pset is auto selected by Job.
E233
Final target range error
-
This error code is displayed when an attempt is made to tighten with a final target out of range (larger than tool max torque or 9999).
E234
Start final angle range error
-
This error code is displayed when an attempt is made to tighten with a start final angle out of range.
E235
Target angle range error
-
E236
Configuration set inconsistent
Yes
This error code is displayed if one device on the IO bus has the right ID but the wrong type (for example a selector is connected and a re-alarm is configured).
E237
Strategy Configuration error
-
No valid control strategy was chosen for the stored Pset.
E238
Not possible to run a multistage with a click wrench Pset
-
An attempt was made to perform a multistage tightening containing at least one Pset with a click wrench strategy.
E240
Password Incorrect Input Source
-
The password is entered from an invalid source according to the configuration.
E241
Password Access Denied
-
E242
Password Locked Out
-
39
Page 40
E250
Maxtime for first tightening run out (job)
-
This message is displayed and the job is terminated if the first tightening is not performed within the specified time.
E251
Maxtime to complete job run out
-
This message is displayed and the job is terminated if the job is not completed within the specified time.
E300-E399: Statistical errors E333
Not allowed subscription
-
The requested statistic subscription is not allowed. For example it is not allowed to set an angle statistic subscription for a Pset using only the torque control strategy.
E334
No statistic available for this Pset
-
The Pset strategy is not suitable to calculate statistics (no strategy is chosen, DS control)
E335
Not enough data
-
No enough data were available to calculate the statistic control limits.
E336
Mem alloc fail
-
It was not possible to allocate enough memory for the statistic subscription.
E340
Xucl tq
-
The last subgroup mean torque value is larger than the upper control limit.
E341
Xlcl tq
-
The last subgroup mean torque value is lower than the lower control limit.
E342
Rucl tq
-
The last subgroup range torque value is larger than the upper control limit.
E343
Rlcl tq
-
The last subgroup range torque value is lower than the lower control limit.
E344
Cp tq
-
The torque Cp is lower than 2.
E345
Cpk tq
-
The torque Cpk is lower than 1,33.
E354
2sigma x tq
-
Trend deviation alarm, the last subgroup torque average is outside Xtq-bar-bar – 2 sigma.
E355
2sigma r tq
-
Trend deviation alarm, the last subgroup torque range average is outside Rtq-bar-bar – 2 sigma.
E360
Xucl ang
-
The last subgroup mean angle value is larger than the upper control limit.
E361
Xlcl ang
-
The last subgroup mean angle value is lower than the lower control limit.
40