Page 31

SYNCHRONISATION PROGRAMMING Software Setup 1) Make sure that all Power Focus units in the synchronised group are part of the same Cell (see cell programming). 2) Decide which units should act as Sync Reference and Sync Members according to HW setup. 3) For the Sync members: – Set Sync reference IP address in the appropriate field. – Set Tool start select source to Sync start. – Configure the 4-pin connector on the back panel for remote start. – Re-start the Sync Member. – Repeat step 1-4 for all Sync Members.

4) For the Sync reference: – Set Sync reference IP address equal to own IP address. – Create the Sync Group List and set other Sync options. – Re-start Sync Reference. – Pset programming, and I/O-setup is done only on the Sync Reference.

31

Page 32

MONITORING IN TOOLSTALK ToolsTalk provides a number of monitors designed to present extensive information about various functions of Power Focus. Among others are: Operator Monitor Detailed information about the tightening operation is presented.

Get all results Power Focus can store up to 5000 individual tightening results. With the Get All Results option, the user is able to retrieve and view these.

By choosing Save To File the results are saved into a text-file. The user can also choose to open and view the results in Microsoft Excel® by selecting Open In Excel.

32

Page 33

TRACES / STATISTICS These are three different ways to activate the traces: 1) Select Window in Main Row and then click on Activate->Trace. 2) Use the PF map. Double-click on Trace. 3) Use Trace icon in Toolbar. Click on the icon.

Statistics The statistic setup can be found under Pset – Statistic Programming. There you are able among others to program statistical alarms like SPC, etc.

33

Page 34

SERVICE SETUP Under Diagnostic – Configuration – Tool service, this window shows the service status of the tool.

Here you can see information about last service date and the number of tightenings after service. By turning the Service indicator alarm On, the Power Focus will automatically alert the user when the service interval has expired.

34

Page 35

EVENT CODES Event code

Group

Description

E000-E099

0

Rundown failures

E100-E199

1

Event-related errors

E200-E299

2

User input error

E300-E399

3

Statistical errors

E400-E499

4

Communication errors

E500-E599

5

Hardware errors TOOL

E600-E699

6

Hardware errors DC3000/MC3000

E700-E799

7

Hardware errors

E800-E899

8

Software errors

E900-E999

9

Errors MMI3000

Event Code

Event Text

Acknowledge

Explanation

E000-E099: Rundown errors E001

Torque LO

-

Start button was probably released to early. Let the tool «finish» the tightening.

E002

Torque HI

-

The programming is probably bad. Make sure that you have some movement on the socket in the second stage.

E003

Torque measurement possibly invalid

-

E004

Angle1 LO

-

E005

Angle1 HI

-

Check the programming or the joint

E006

Angle2 LO

-

Check the programming or the joint

E007

Angle2 HI

-

Check the programming or the joint

Check the programming or the joint

E100-E199: Event-related errors E101

Pset invalid (check sum error)

Yes

E102

Rundown prohibited due to Lock on Reject

-

This error code is displayed after a NOK tightening when the function Lock on Reject is activated. In this case the tool is disabled, the tool can be unlocked with a digital input or with the tool ring.

E103

Forward direction prohibited via digital input

-

The forward direction is prohibited via the digital input.

35

Page 36

E104

Reverse direction prohibited

-

The reverse direction is prohibited via digital input or in Job mode. The reverse direction is prohibited in job mode when Lock at Job Done is selected or batch mode is configured to NOK+OK.

E105

Reverse direction prohibited via ToolsTalk

-

The reverse direction is prohibited via Tools Talk.

E106

Rundown prohibited due to active CycleHold

-

The tool is locked due to Cycle hold.

E107

Rundown prohibited due to Line Control, batch not enabled

-

A job using Line Control is selected. The job does not start until Line Control Start signal is received.

E108

Rundown prohibited due to keypad usage

-

E109

Pset revision not supported by this SW

-

E110

Configuration revision not supported by this SW

-

E111

MC Rundown timeout

-

E112

Rehit

-

E113

Current limit reached – Rundown aborted

Yes

E114

OpenEnd Reference position not found

Yes

E115

Direction uncertain

-

E116

SelfTap max torque reached – Rundown aborted

-

E120

MC Motortuning failure

Yes

Motor tuning failed. The trigger could have been released before the end of the motor tuning or the tool has a defect.

E121

OpenEnd tuning failure

Yes

This error indicates that the open end tuning command has not been successfully performed. Either the command was aborted by the operator or the command could not be performed for any other reason.

E126

Multistage aborted

-

This error indicates that the current running multistage has not been performed entirely (the drive has been shut off or the tool trigger was released before the end).

The rundown was not terminated before the drive time out (2 minutes).

The current limit has been reached; the drive is disabled.

36

Page 37

E127

PVT shut off

-

This error indicates that the drive was shut off in the Self-tap or prevail phase of the rundown.

E128

Trigger lost

-

When the function Trigger lost is activated in the Pset, this error indicates that the trigger of the tool was released before final target.

E129

Torque lower than target

-

When the function torque lower than target is activated in the Pset, this error indicates that the torque result is below final target. The torque status is NOK even if the torque result was larger than final torque min.

E130

Post view torque shut off

E131

Tool Disconnected

This error indicates that the tool is not connected Yes to the controller or that the tool cable has been damaged.

E132

Wrong tool start input setting

1) Check if the remote start wiring in the PF is correctly set in accordance to the settings in the Yes Configuration parameters (C220). 2) Check if the tool trigger is constantly pressed or if there is some malfunction in the tool.

E133

Forward direction prohibited via ToolsTalk

-

The forward direction is prohibited via Tools Talk.

E134

MC Target input active at start attempt

-

The target signal is active in the drive though the tightening has been acknowledged by the CC-card.

E135

MC No start Ack from CC

-

No start acknowledgement has been received by the MC drive from the CC-card (timeout 32s)

E136

Rundown prohibited due to batch locked

-

This error is displayed if the function lock at batch OK is enabled and when the batch is completed. The tool can only be unlocked via a digital input.

E137

Rundown prohibited via field bus

-

The rundown is prohibited via field bus.

E138

Wrong tool start input source

-

It is only possible to start the tool from the selected tool start select source.

E139

Rundown prohibited via Open protocol

-

The rundown is prohibited via Open protocol.

E140

Insert user ID card to release tool

-

The tool is locked, the user must insert his ID card in the card reader to release the tool.

E141

MC Current Monitoring torque deviation

Yes

Post view torque conditions were not fulfilled.

37

Page 38

E142

MC SyncroTorque diffstop

-

E150

Job client does not respond

-

When running a Cell Job, this error is displayed by the job master when one of the job members does not respond.

E151

Job in OFF mode

-

It is not possible to select a new job, the PF3000 is in Job Off mode.

E152

PF locked in job mode

-

This error appears when in a forced cell job an attempt is made to tighten with a controller which is not currently active or when a controller has performed all tightenings.

E153

Not Ok to select new job

-

A job is currently running, it is not possible to select a new job until the first is finished in some way (completed or aborted). This message is also displayed if a job is selected on a job member.

E154

Remote job running

-

When running a Cell Job, this is displayed by the job members when a cell job is selected on the job master.

E155

Remote job aborted

-

When running a Cell Job, This is displayed by the job members when a cell job is aborted.

E156

Job members lost

-

When running a Cell Job, this is displayed by the master when it has lost contact with one of its job member.

E157

Job reference lost

-

When running a Cell Job, this is displayed by the job members when they have lost contact with their Job Master.

E158

Invalid Job ID

-

When the selected job does not exist.

E159

No Pset In Selected Job

-

When the selected job does not contain any Pset.

E160

Job select source not valid

-

Attempt to select a Job with the wrong input source.

E161

Line Control Alert 1

-

The line control has been activated, and the first control alert limit has been reached.

E162

Line Control Alert 2

-

The line control has been activated, and the second control alert limit has been reached.

E180

Euchner Ident System only supports Siemens 3964R protocol

-

The protocol settings for the serial COM port 1 is not set to 3964R, it is not possible to use the Euchner Ident System with this configuration.

E181

Not possible to read ID card

-

It was not possible to read the ID card inserted in the Euchner system.

38

Page 39

E200-E299: User input error E201

First target > Final target

-

E202

Final target > Tool max torque

-

E203

First target < XX % of tool max torque

-

E204

Final target < YY % of tool max torque

-

E205

Pset not open

-

E206

Pset number invalid

-

An attempt was made to do a tightening with the wrong Pset within a job.

E207

Wrong Pset Select Source

-

Attempt to select Pset from a source not specified in the Cset.

E208

Not Ok to select new Pset

-

It is not allowed to select new Pset when the already selected Pset is auto selected by Job.

E233

Final target range error

-

This error code is displayed when an attempt is made to tighten with a final target out of range (larger than tool max torque or 9999).

E234

Start final angle range error

-

This error code is displayed when an attempt is made to tighten with a start final angle out of range.

E235

Target angle range error

-

E236

Configuration set inconsistent

Yes

This error code is displayed if one device on the IO bus has the right ID but the wrong type (for example a selector is connected and a re-alarm is configured).

E237

Strategy Configuration error

-

No valid control strategy was chosen for the stored Pset.

E238

Not possible to run a multistage with a click wrench Pset

-

An attempt was made to perform a multistage tightening containing at least one Pset with a click wrench strategy.

E240

Password Incorrect Input Source

-

The password is entered from an invalid source according to the configuration.

E241

Password Access Denied

-

E242

Password Locked Out

-

39

Page 40

E250

Maxtime for first tightening run out (job)

-

This message is displayed and the job is terminated if the first tightening is not performed within the specified time.

E251

Maxtime to complete job run out

-

This message is displayed and the job is terminated if the job is not completed within the specified time.

E300-E399: Statistical errors E333

Not allowed subscription

-

The requested statistic subscription is not allowed. For example it is not allowed to set an angle statistic subscription for a Pset using only the torque control strategy.

E334

No statistic available for this Pset

-

The Pset strategy is not suitable to calculate statistics (no strategy is chosen, DS control)

E335

Not enough data

-

No enough data were available to calculate the statistic control limits.

E336

Mem alloc fail

-

It was not possible to allocate enough memory for the statistic subscription.

E340

Xucl tq

-

The last subgroup mean torque value is larger than the upper control limit.

E341

Xlcl tq

-

The last subgroup mean torque value is lower than the lower control limit.

E342

Rucl tq

-

The last subgroup range torque value is larger than the upper control limit.

E343

Rlcl tq

-

The last subgroup range torque value is lower than the lower control limit.

E344

Cp tq

-

The torque Cp is lower than 2.

E345

Cpk tq

-

The torque Cpk is lower than 1,33.

E354

2sigma x tq

-

Trend deviation alarm, the last subgroup torque average is outside Xtq-bar-bar – 2 sigma.

E355

2sigma r tq

-

Trend deviation alarm, the last subgroup torque range average is outside Rtq-bar-bar – 2 sigma.

E360

Xucl ang

-

The last subgroup mean angle value is larger than the upper control limit.

E361

Xlcl ang

-

The last subgroup mean angle value is lower than the lower control limit.

40