Page 133

Job •

Select and set Job options parameters. [See chapter 18, Parameter list, Job section, for parameter descriptions]

•

Note! Forced job must be selected if Auto Select is used.

9.4

Selecting a Job

In a Job selection the Job ID is used. When a Job is selected, the channels involved in the Job will be forced into Job Mode. Once a Job has been selected, it is possible to select a new Job, until the first tightening is started or a batch increment is performed. At that state the only way to select a new Job is either to complete the running Job or to abort the running Job.

9.4.1

Job select source and Job select source override

It is possible to define two different parameters that will be used for Job selection, Job Select Source and Job Select Source Override. These parameters should be set in Config [see chapter 10, Config]. For a more detailed parameter description, see chapter 18, Parameter List. To be able to select a Job, at least one of the two parameters has to be set. Sources that Jobs could be selected from are the following: • Digin (Digital Input) • Ethernet/Serial • Identifier • Field Bus • PF Keyboard

133

Page 134

Job Job Select Source Override has a higher priority than Job Select Source. If a Job is chosen from Select Source then it is possible to select a new Job from the same source or Select Source Override. On the other hand, if a Job is chosen from Select Source Override then it is only possible to select a new Job from the same source. This function is normally used when the normal Select Source (i.e. Ethernet) is down and a manual operation is needed. Note! The system will remember the most recently selected source until the Job either is completed or aborted. Note! To be able to select a Job from the Power Focus 3000 Graph display, Job Select Source or Job Select Source Override parameters must be set to “PF keyboard”.

9.4.2

Selecting and running a Cell Job

In order to be able to select a cell Job, the Job Reference has to communicate with the Job Clients, which is part of the selected Job. Otherwise, the Job Reference will not start the Job. If the Job Reference loses contact with a Job Client it will try to re-establish the communication. If the Job Reference loses communication with a Job Client during an ongoing Job, the following will happen: • If the client that is disconnected has tightenings left to perform the Job Reference will abort the running Job immediately. • If the client that is disconnected has performed all tightenings left to perform or had no part in the running Job, the Job will continue. If a Job Client loses communication with its Job Reference, it will stop its ongoing part of the Job and lock the tool.

134

Page 135

Job

9.5

Job functions and features

Job functions and features enable the operator to change the status of a running Job. All Job functions and features are available from the following devices. - A defined digital input and/or I/O expander - Tools Talk - Graph Display - Field Bus Running Job

Job Monitor

Select the Job to run from the combo box (in the selection row in ToolsTalk). Note! To run the Job from ToolsTalk the Job select source (Config parameter C221) have to be in Ethernet/Serial mode. Click on the arrow to the right of this icon to select Job Monitor. Job Monitor displays created Jobs and provides functionality for managing (se picture below).

135

Page 136

Job In the Job Monitor window the current/latest Job Status (Running, OK, NOK and Aborted) can be displayed. Job Monitor also displays Job ID and if the running order is fr ee or forced for a running Job.

The table below describes the functions in Job Monitor.

136

Page 137

Job Functions

Restart Job

Description This function allows you to re-start the running Job without needing to reselect the Job. All Batch counters in the running Job resets and the Job options timers will also be restarted.

Decrement

This function allows you to re-do the last tightening in a Job. The batch counter of the Pset or Multistage is decreased with one step. It is not possible to go back one stage after the job has been completed.

Increment

In both forced order Job and free order Job batch decrement is only possible from the Job reference. This function allows you to skip the batch counter value of a Pset or a Multistage without performing a tightening. It is allowed to complete a Job by using the Batch Increment function. If using batch increment to complete a Job, the status of the Job will be not ok . How to use batch increment in: 1. Forced order Job Batch Increment is possible from the Job reference or the Job member with the active Pset. 2. Free order Job Batch Increment is possible from the Job member with the active Pset.

Bypass

Abort Job

This function allows you to skip a specific Pset or Multistage in the running Job, independently of the batch size. When a Pset or Multistage is bypassed, the batch counter will be set equal to the batch size value and the Pset will be considered as completed. If using bypass to complete a Job, the status of the Job will be not ok . How to use bypass in: 1. Forced order Job Bypass is possible from the Job reference or the Job client with active Pset. 2. Free order Job Bypass is only possible from the Job client with active Pset It is only possible to select or abort a Job from the Job reference. Abort can be an external signal as well as an internal command. (see subchapter for max time for first tightening and max time to complete Job) When a Job abort request is received, the Job function will wait for the ongoing tightening result to count it in the Job, before aborting the Job. A cancelled Job will be regarded as an aborted Job. Abort Job has no effect if there is no running Job.

137

Page 138

Job Job Off (Emergency mode)

This function offers the possibility to turn off Job functionality and unlock all involved tools without delete the Job configuration. • In case of a running Job: The effect of Job Off on a running Job is the same as aborting the Job besides that the tool/tools will not be disabled. The Job reference will automatically choose Pset 1 for all of the members. •

In case of no running Job: The Job reference unit will unlock all of the members tools, and will automatically choose Pset 1 for all of the members.

When a Power Focus unit is in Job Off mode, it is possible to perform tightening with any existing Pset or Multistage. Note that as long as the Job reference is in Job Off mode there is no possibility to select a new Job. Job Off mode must first be inverted before selecting a new Job. A Power Focus 3000 has Job On (Job Off invert) mode as default settings. The Job reference unit will remember the Job Off mode after a reboot. Note that if the Job reference is in the Job Off mode and the rest of the group is in the Job On (Job Off invert) mode, it is still not possible to select Job. The only occasion when the Job Off functionality affects the Job clients is when the Job clients have lost communication with their Job reference. In this case it is possibility to unlock the clients locally.

138

Page 139

Job

9.6

Job result

It is possible to follow a detailed status of a running Job through ToolsTalk or the graphical display on a Power Focus 3000. The Job Status presented to the operator includes the following information: • • • • • •

Type of Job (Forced or Free Ordered or Repeat Job). A list of all Psets or Multistages included in the Job in their predefined order. Channel ID of the Power Focus 3000 unit that each Pset or Multistage belongs to. Status of Psets or Multistages (Executed or not) Present Batch Counter value of each Pset or Multistage. Batch size value of each Pset or Multistage.

The status information is updated each time a tightening or any Job feature has affected the running Job. Job Completion A Job is considered completed when all Psets or Multistages included in the Job have been completed. A Pset or Multistage is considered completed when its batch Counter value equals the batch Size for that Pset or Multistage. A Pset or Multistage can be completed through tightenings or by using functions such as Batch increment or Bypass. Job Status Job OK Job OK is received if all Psets or Multistages included in the Job have been completed through OK tightenings. Job NOK A Job is considered as NOK (Not OK) if the functions Increment, Bypass or Abort Job was used. Job Aborted An cancelled Job is considered as aborted (equal to NOK)

139

Page 140

Job Indicator Lights n x OK The n x OK light indicates when the number of approved rundowns corresponds to the number (batch size) programmed in the Power Focus 3000. The indicator is active until the next tightening or Job selection is initiated. OK The OK light indicates when the result of the rundown is within the specified limits. The indicator is active until the next tightening or Job selection is initiated. NOK The NOK light indicates when the result of the rundown falls outside the specified limits. The light is active until the next cycle starts. JOB OK

The JOB OK light indicates when the Job is finished and all tightenings in the Job were correctly performed. The light is active until the next tightening or Job starts or when the system is reset.

140

Page 141

Job

9.7

Situations in which the tool is in locked mode

When the selected Job has its option lock at Job done configured to active, all tools in the Job group will be locked after the Job is performed or aborted. The Power Focus 3000 unit, which is locked in Job mode, will remain locked until a new Job is selected, or until tool is enable again. As the lock in the Job done parameter is stored in Power Focus memory, it is not possible to unlock the tool by rebooting the unit. During an ongoing Job with lock at Job done parameter active, all the clients that have no part in the Job will be locked. This is valid for all the clients that had contact with their Job reference at the time the Job was selected.

9.7.1

Unlocking the tool

Unlock the tool by selecting a new Job, selecting Job Off, or deleting all existing Jobs. Remember that you can only unlock the tool from the Job reference, unless you select Job Off. All Job clients have to be active to be unlocked by the Job reference. Note that it is not possible to unlock the tool by rebooting the Power Focus 3000! When a Job is completed or aborted, the following will happen: • If the last Job had lock at Job done chosen, it will lock the tool for all units in the Job group even the ones that had no part in the last Job. •

If the last Job did not have Lock at Job done selected, or if the Job mode is changed from running to Job off, functionality will choose latest Pset which was selected from the Dig in, FieldBus or Selector in case one of these is Pset select source. Otherwise the latest selected Pset in the Job will remains.