Page 223
Hardware Description
20.2
Connections
20.2.1 Power Focus 3000 Compact back panel
1. 2.
Printer Serial #2 (RS232)
3. 4. 5.
Ethernet RBU FieldBus card (optional)
6. 7. 8.
Tool output Digital input Relays
9. 10. 11.
Serial #1 (RS232) I/O-bus I/O-bus
12. 13. 14.
Remote start Mains power connector GFI, Ground Fault Interrupter
15.
Main fuse
6 7 1 8 2 14
3
9 10
4
11 12 13 5 15
223
Page 224
Hardware Description
20.2.2 Power Focus Graph back panel 1. 2.
Printer Serial #2 (RS232)
3. 4. 5.
Ethernet RBU FieldBus card (optional)
6. 7. 8.
Tool output Digital input Relays
2 1
7 8
11 13 10
15. Main fuse
224
5
12
12. Remote start 13. Mains power connector 14. GFI, Ground Fault Interrupter
Weight
Power Focus model Compact Graph
4
6
9. Serial #1 (RS232) 10. I/O-bus 11. I/O-bus
20.3
3
Weight [Kg] 12 16
9 15
14
Page 225
Hardware Description
20.4
Power
Power Focus 3000 operates on a single-phase 110 or 230 VAC line voltage. Power Focus 3000 has a function for sensing the line voltage automatically. This means that the Power Focus automatically switches to the voltage you connect to. Line voltage Line voltage 110 VAC (90-120) 230 VAC (200-240)
Power consumption Power consumption depends on the speed and torque of the tool. High speed and torque give the highest power. Power Focus model/Tool Compact S4/S7 S9 Graph S4/S7 S9
Standby [W] 20 20 20 20
Free running [W] 150 200 150 200
Mains Fuse Recommended mains fuses ( power outlet): Tool S4/S7 S9
Mains Voltage [V] 115 230 115 230
Fuse [A] 15 10 20 16
If you are running PF3000 as standalone units and trigger the tools manually (random) it is normally possible to connect up to three PF 3000 to one power drop. If you are synchronising the spindles you will need one drop for each PF3000. Wiring All connections are located on the rear of the units. If it is necessary to change the plug on the mains cable, use the following wiring guide: Colour Brown or black Blue Green and yellow
Input Live Neutral Protective ground
Note! The power cable is the mains disconnecting device. If you open the Power Focus, first pull out the power cable to make sure that the unit is free from electric power. Note! Do not use galvanically insulated line voltage since it disrupts the function of the Ground Fault Interrupter (GFI). Note that the test button for the GFI activates the GFI even if the Power Focus is supplied with power from an isolated transformer. 225
Page 226
Hardware Description
20.5 No. 1.
2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13.
14.
15. 16. 17.
226
Parts List
Part Description Fuse Holder Fuse Fuse Card Connector Compact Card Connector Graph Drive Card Motor Card Display Card Compact Ground Fault Interrupter Power switch Back Panel Lock Front Panel Compact Membrane switch Front Door Compact Back Panel Compact Back Panel Graph Control Card FieldBus Card
1) 2)
Display Card (Complete) Display Card (without keypad) 3) LCD display 4) Keypad 5) Keypad Card Front Panel Graph Overlay Front Door Graph Support strap
Ordering Number 4222-0412-00 4222-0413-15 4222-0413-20 4222-0399-80 4222-0398-80 4222-0386-80 4222-0387-80 4222-0391-80 4222-0603-80 4222-0020-01 4222-0362-80 4222-0363-01 4222-0604-83 4222-0604-85 4222-0347-90 4222-0323-82 4222-0374-81 4222-0402-80 4222-0649-80 4222-0651-80 4222-0652-80 4222-0802-80 4222-0374-87 4222-0478-80 4222-0381-81 4222-0473-00 4222-0477-80
Info.
4222-0380-85 4222-0380-87 4222-0374-88 4222-0757-12
Tensor S4/7 Tensor S9
15 A (S4/7) 20 A (S9)
Tensor S4/7 Tensor S9
30 mA
Tensor S4/7 Tensor S9 Not Shown
DeviceNet Profibus-DT InterBus ModBus plus For Graph
Not shown
Page 227
Hardware Description Power Focus 3000 Compact
227
Page 228
Hardware Description Power Focus 3000 Graph
228
Page 229
Appendix A
21
Appendix A: QUICK Reference Guide
Use this appendix in conjunction with the Parameter List, chapter 18, as a reference guide when programming the Power Focus 3000. A more general description of the tightening and control strategies available can be found in Control and Monitoring, chapter 6. A joint is regarded as hard if the clamping angle, a, is small and soft if a is large. There is no limit, but test standards define a < 30° as hard. The dynamic effects on tightening increase dramatically if angles go down substantially (approximately 15°).
a
Find the page below that describes the desired strategy and study the graph and the parameters that need to be set. Note that the graphs are presented schematically, which means that your programming results may look different compared to the graph.
229
Page 230
Appendix A
21.1
Tq Con
21.1.1 One stage Torque
P114 Final tq max
Acceptance window
P113 Final Target
P112 Final tq min
P110 Cycle start P115 Cycle complete
Time P142 Soft start time
P141 End time P130 Soft start speed
P135 Step 1 ramp
Tool speed P131 Step 1 speed
P1xx Programming Open new Pset
P10x Control Strategy P100 Tq con P101 One stage
P14x Time P141 End time P142 Soft start time P144 Cycle abort timer
P15x Batch P150 Batch count P151 Batch size
230
P11x Torque P110 Cycle start P112 Final tq min P113 Final target P114 Final tq max P115 Cycle complete
P13x Speed/Ramp P130 Soft start speed P131 Step 1 speed P135 Step 1 ramp
Page 231
Appendix A
21.1.2 Two stage Torque P114 Final tq max P113 Final Target Acceptance window
P112 Final tq min P111 First Target
P110 Cycle start P115 Cycle complete Time P142 Soft start time P141 End time
P135 Step 1 ramp P130 Soft start speed
P132 Step 2 speed P136 Step 2 ramp
P131 Step 1 speed
Tool speed
P1xx Programming Open new Pset
P10x Control Strategy P100 Tq con P101 Two stage
P14x Time P141 End time P142 Soft start time P144 Cycle abort timer
P15x Batch P150 Batch count P151 Batch size
P11x Torque P110 Cycle start P111 First target P112 Final tq min P113 Final target P114 Final tq max P115 Cycle complete
P13x Speed/Ramp P130 Soft start speed P131 Step 1 speed P132 Step 2 speed P135 Step 1 ramp P136 Step 2 ramp
231
Page 232
Appendix A
21.1.3 Quick step Torque P114 Final tq max
P113 Final Target Acceptance window
P112 Final tq min P111 First Target
P110 Cycle start
P115 Cycle complete Time
P142 Soft start time P141 End time
P130 Soft start speed P135 Step 1 ramp P132 Step 2 speed
P131 Step 1 speed
Tool speed
P1xx Programming Open new Pset
P10x Control Strategy P100 Tq con P101 Quick step
P14x Time P141 End time P142 Soft start time P144 Cycle abort timer
P15x Batch P150 Batch count P151 Batch size
232
P11x Torque P110 Cycle start P111 First target P112 Final tq min P113 Final target P114 Final tq max P115 Cycle complete
P13x Speed/Ramp P130 Soft start speed P131 Step 1 speed P132 Step 2 speed P135 Step 1 ramp