Page 223

Hardware Description

20.2

Connections

20.2.1 Power Focus 3000 Compact back panel

1. 2.

Printer Serial #2 (RS232)

3. 4. 5.

Ethernet RBU FieldBus card (optional)

6. 7. 8.

Tool output Digital input Relays

9. 10. 11.

Serial #1 (RS232) I/O-bus I/O-bus

12. 13. 14.

Remote start Mains power connector GFI, Ground Fault Interrupter

15.

Main fuse

6 7 1 8 2 14

3

9 10

4

11 12 13 5 15

223

Page 224

Hardware Description

20.2.2 Power Focus Graph back panel 1. 2.

Printer Serial #2 (RS232)

3. 4. 5.

Ethernet RBU FieldBus card (optional)

6. 7. 8.

Tool output Digital input Relays

2 1

7 8

11 13 10

15. Main fuse

224

5

12

12. Remote start 13. Mains power connector 14. GFI, Ground Fault Interrupter

Weight

Power Focus model Compact Graph

4

6

9. Serial #1 (RS232) 10. I/O-bus 11. I/O-bus

20.3

3

Weight [Kg] 12 16

9 15

14

Page 225

Hardware Description

20.4

Power

Power Focus 3000 operates on a single-phase 110 or 230 VAC line voltage. Power Focus 3000 has a function for sensing the line voltage automatically. This means that the Power Focus automatically switches to the voltage you connect to. Line voltage Line voltage 110 VAC (90-120) 230 VAC (200-240)

Power consumption Power consumption depends on the speed and torque of the tool. High speed and torque give the highest power. Power Focus model/Tool Compact S4/S7 S9 Graph S4/S7 S9

Standby [W] 20 20 20 20

Free running [W] 150 200 150 200

Mains Fuse Recommended mains fuses ( power outlet): Tool S4/S7 S9

Mains Voltage [V] 115 230 115 230

Fuse [A] 15 10 20 16

If you are running PF3000 as standalone units and trigger the tools manually (random) it is normally possible to connect up to three PF 3000 to one power drop. If you are synchronising the spindles you will need one drop for each PF3000. Wiring All connections are located on the rear of the units. If it is necessary to change the plug on the mains cable, use the following wiring guide: Colour Brown or black Blue Green and yellow

Input Live Neutral Protective ground

Note! The power cable is the mains disconnecting device. If you open the Power Focus, first pull out the power cable to make sure that the unit is free from electric power. Note! Do not use galvanically insulated line voltage since it disrupts the function of the Ground Fault Interrupter (GFI). Note that the test button for the GFI activates the GFI even if the Power Focus is supplied with power from an isolated transformer. 225

Page 226

Hardware Description

20.5 No. 1.

2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13.

14.

15. 16. 17.

226

Parts List

Part Description Fuse Holder Fuse Fuse Card Connector Compact Card Connector Graph Drive Card Motor Card Display Card Compact Ground Fault Interrupter Power switch Back Panel Lock Front Panel Compact Membrane switch Front Door Compact Back Panel Compact Back Panel Graph Control Card FieldBus Card

1) 2)

Display Card (Complete) Display Card (without keypad) 3) LCD display 4) Keypad 5) Keypad Card Front Panel Graph Overlay Front Door Graph Support strap

Ordering Number 4222-0412-00 4222-0413-15 4222-0413-20 4222-0399-80 4222-0398-80 4222-0386-80 4222-0387-80 4222-0391-80 4222-0603-80 4222-0020-01 4222-0362-80 4222-0363-01 4222-0604-83 4222-0604-85 4222-0347-90 4222-0323-82 4222-0374-81 4222-0402-80 4222-0649-80 4222-0651-80 4222-0652-80 4222-0802-80 4222-0374-87 4222-0478-80 4222-0381-81 4222-0473-00 4222-0477-80

Info.

4222-0380-85 4222-0380-87 4222-0374-88 4222-0757-12

Tensor S4/7 Tensor S9

15 A (S4/7) 20 A (S9)

Tensor S4/7 Tensor S9

30 mA

Tensor S4/7 Tensor S9 Not Shown

DeviceNet Profibus-DT InterBus ModBus plus For Graph

Not shown

Page 227

Hardware Description Power Focus 3000 Compact

227

Page 228

Hardware Description Power Focus 3000 Graph

228

Page 229

Appendix A

21

Appendix A: QUICK Reference Guide

Use this appendix in conjunction with the Parameter List, chapter 18, as a reference guide when programming the Power Focus 3000. A more general description of the tightening and control strategies available can be found in Control and Monitoring, chapter 6. A joint is regarded as hard if the clamping angle, a, is small and soft if a is large. There is no limit, but test standards define a < 30° as hard. The dynamic effects on tightening increase dramatically if angles go down substantially (approximately 15°).

a

Find the page below that describes the desired strategy and study the graph and the parameters that need to be set. Note that the graphs are presented schematically, which means that your programming results may look different compared to the graph.

229

Page 230

Appendix A

21.1

Tq Con

21.1.1 One stage Torque

P114 Final tq max

Acceptance window

P113 Final Target

P112 Final tq min

P110 Cycle start P115 Cycle complete

Time P142 Soft start time

P141 End time P130 Soft start speed

P135 Step 1 ramp

Tool speed P131 Step 1 speed

P1xx Programming Open new Pset

P10x Control Strategy P100 Tq con P101 One stage

P14x Time P141 End time P142 Soft start time P144 Cycle abort timer

P15x Batch P150 Batch count P151 Batch size

230

P11x Torque P110 Cycle start P112 Final tq min P113 Final target P114 Final tq max P115 Cycle complete

P13x Speed/Ramp P130 Soft start speed P131 Step 1 speed P135 Step 1 ramp

Page 231

Appendix A

21.1.2 Two stage Torque P114 Final tq max P113 Final Target Acceptance window

P112 Final tq min P111 First Target

P110 Cycle start P115 Cycle complete Time P142 Soft start time P141 End time

P135 Step 1 ramp P130 Soft start speed

P132 Step 2 speed P136 Step 2 ramp

P131 Step 1 speed

Tool speed

P1xx Programming Open new Pset

P10x Control Strategy P100 Tq con P101 Two stage

P14x Time P141 End time P142 Soft start time P144 Cycle abort timer

P15x Batch P150 Batch count P151 Batch size

P11x Torque P110 Cycle start P111 First target P112 Final tq min P113 Final target P114 Final tq max P115 Cycle complete

P13x Speed/Ramp P130 Soft start speed P131 Step 1 speed P132 Step 2 speed P135 Step 1 ramp P136 Step 2 ramp

231

Page 232

Appendix A

21.1.3 Quick step Torque P114 Final tq max

P113 Final Target Acceptance window

P112 Final tq min P111 First Target

P110 Cycle start

P115 Cycle complete Time

P142 Soft start time P141 End time

P130 Soft start speed P135 Step 1 ramp P132 Step 2 speed

P131 Step 1 speed

Tool speed

P1xx Programming Open new Pset

P10x Control Strategy P100 Tq con P101 Quick step

P14x Time P141 End time P142 Soft start time P144 Cycle abort timer

P15x Batch P150 Batch count P151 Batch size

232

P11x Torque P110 Cycle start P111 First target P112 Final tq min P113 Final target P114 Final tq max P115 Cycle complete

P13x Speed/Ramp P130 Soft start speed P131 Step 1 speed P132 Step 2 speed P135 Step 1 ramp