Page 213

EXXX "Text"

Information

Tool locked

Tool not ready

PF not ready

Acknowledg ement

Category

Short description (graphic display)

Event code

Event codes

1 / 2 / 3 / 4 ACK / - PFNR / - TNR / - LCK "Text" /-

E349

7dec r tq

1

-

-

-

-

E350

7above x tq

1

-

-

-

-

E351

7below x tq

1

-

-

-

-

E352

7above r tq

1

-

-

-

-

E353

7below r tq

1

-

-

-

-

E354

2sigma x tq

1

-

-

-

-

E355

2sigma r tq

1

-

-

-

-

E360

Xucl ang

1

-

-

-

-

E361

Xlcl ang

1

-

-

-

-

E362

Rucl ang

1

-

-

-

-

E363

Rlcl ang

1

-

-

-

-

E364 E365 E366

Cp ang Cpk ang 7inc x ang

1 1 1

-

-

-

-

E367

7dec x ang

1

-

-

-

-

E368

7inc r ang

1

-

-

-

-

E369

7dec r ang

1

-

-

-

-

E370

7above x ang

1

-

-

-

-

E371

7below x ang

1

-

-

-

-

Trend deviation alarm, the subgroup torque mean value has decreased 7 times consecutively. Trend deviation alarm, the subgroup torque mean value has been above the average mean value of the average of the last ten subgroups 7 times consecutively. Trend deviation alarm, the subgroup torque mean value has been below the average mean value of the average of the last ten subgroups 7 times consecutively. Trend deviation alarm, the subgroup torque range value has been above the average range value of the average of the last ten subgroups 7 times consecutively. Trend deviation alarm, the subgroup torque range value has been below the average range value of the average of the last ten subgroups 7 times consecutively. Trend deviation alarm, the last subgroup torque average is outside Xtq-bar-bar – 2 sigma. Trend deviation alarm, the last subgroup torque range average is outside Rtq-bar-bar – 2 sigma. The last subgroup mean angle value is larger than the upper control limit. The last subgroup mean angle value is lower than the lower control limit. The last subgroup range angle value is larger than the upper control limit. The last subgroup range angle value is lower than the lower control limit. The angle Cp is lower than 2. The angle Cpk is lower than 1,33. Trend deviation alarm, the subgroup angle mean value has increased 7 times consecutively. Trend deviation alarm, the subgroup angle mean value has decreased 7 times consecutively. Trend deviation alarm, the subgroup angle range value has increased 7 times consecutively. Trend deviation alarm, the subgroup angle mean value has decreased 7 times consecutively. Trend deviation alarm, the subgroup angle mean value has been above the average mean value of the average of the last ten subgroups 7 times consecutively. Trend deviation alarm, the subgroup angle mean value has been below the average mean value of the average of the last ten subgroups 7 times consecutively.

213

Page 214

EXXX "Text"

Information

Tool locked

Tool not ready

PF not ready

Acknowledg ement

Category

Short description (graphic display)

Event code

Event codes

1 / 2 / 3 / 4 ACK / - PFNR / - TNR / - LCK "Text" /-

E372

7above r ang

1

-

-

-

-

E373

7below r ang

1

-

-

-

-

E374

2sigma x ang

1

-

-

-

-

E375

2sigma r ang

1

-

-

-

-

E380 E381 E382 E383 E384 E385 E386 E387 E388 E389 E390 E391 E392 E393 E394 E395

Xucl cm Xlcl cm Rucl cm Rlcl cm Cp cm Cpk cm 7inc x cm 7dec x cm 7inc r cm 7dec r cm 7above x cm 7below x cm 7above r cm 7below r cm 2sigma x cm 2sigma r cm

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

-

-

-

-

Trend deviation alarm, the subgroup angle range value has been above the average range value of the average of the last ten subgroups 7 times consecutively. Trend deviation alarm, the subgroup angle range value has been below the average range value of the average of the last ten subgroups 7 times consecutively. Trend deviation alarm, the last subgroup angle average is outside Xang-bar-bar – 2 sigma. Trend deviation alarm, the last subgroup angle range average is outside Rang-bar-bar – 2 sigma.

E400-E499: Communication errors E401

Duplicate device IDs on IO bus

3

ACK

PFNR

TNR

-

E402 E403

IO bus restarted IO device not responding

3 2

ACK ACK

PFNR PFNR

TNR TNR

-

E404

Selector is not connected or not responding

3

ACK

PFNR

TNR

-

E405

IO Expander is not connected or not responding

3

ACK

PFNR

TNR

-

E406

RE-alarm is not connected or not responding

3

ACK

PFNR

TNR

-

E408

Multiple devices of same type on IO bus

3

-

-

TNR

-

214

Two IO devices with the same Id are present on the I/O bus. The IO bus has been restarted. The I/O device is not properly connected or the Id of the device is not the same as the one configured. The selector is not properly connected or the Id of the selector is not the same as the one configured. The I/O expander is not properly connected or the Id of the I/O expander is not the same as the one configured. The Remote alarm is not properly connected or the Id of the Remote alarm is not the same as the one configured.

Page 215

EXXX "Text"

E409 E410

Information

Tool locked

Tool not ready

PF not ready

Acknowledg ement

Category

Short description (graphic display)

Event code

Event codes

1 / 2 / 3 / 4 ACK / - PFNR / - TNR / - LCK "Text" /3 3

-

-

TNR TNR

-

E411 E412 E413 E414 E415 E416 E433

Multiple selectors on IO bus No selector found and Pset source is IO bus Rotary selector has ID <> 1 IO expander has ID <> 2 RE Alarm has ID <> 3 Remote display has ID <> 4 4socket selector has ID <> 5 8socket selector has ID <> 6 No RBU present

3 3 3 3 3 3 4

ACK

PFNR

TNR TNR TNR TNR TNR TNR TNR

-

E434 E438

RBU Timeout RBU file mismatch

4 4

ACK ACK

PFNR PFNR

TNR TNR

-

E439

RBU signal mismatch

4

ACK

PFNR

TNR

-

E440 E441 E442 E443 E444

RBU no files RBU no answer RBU no such file RBU full RBU packet rejected

4 4 4 4 4

ACK ACK ACK ACK ACK

PFNR PFNR PFNR PFNR PFNR

TNR TNR TNR TNR TNR

-

E445 E446 E447 E448 E449 E450 E451

RBU corrupt RBU read error RBU write error RBU delete error RBU flush error RBU list error RBU Update Failed

4 4 4 4 4 4 4

ACK ACK ACK ACK ACK ACK ACK

PFNR PFNR PFNR PFNR PFNR PFNR PFNR

TNR TNR TNR TNR TNR TNR TNR

-

E460

3

-

-

TNR

-

E461 E462 E463 E464

FieldBus Type Mailbox Message Fault FieldBus Type Gen Com Fault FieldBus Mailbox Message Fault FieldBus Gen Com Fault FieldBus Hardware Fault

3 3 3 3

ACK

PFNR

TNR TNR TNR TNR

-

E465

FieldBus Dip switch Error

3

-

-

TNR

-

E466

FieldBus Offline

2

-

-

-

-

E467

FieldBus Configuration Fault

3

-

-

TNR

-

No RBU detected at start -up or RBU found missing at runtime. RBU did not respond to command from PF. A file with incorrect name or size was returned to a read request. An unexpected signal received by the RBU Manager in Idle status.

RBU responds with an answer not matching the last request. This is probably due to duplicates sent when the PF does not acknowledge packages.

RBU Erase failed. One of the database processes failed to synchronise the NVRAM with the RBU.

The FieldBus module is broken and has to be replaced. The software tries to configure the value of node address or baudrate, But the address switch on the FieldBus module is not in the right position to enable software setting. Set switches in the right position, then turn on the power. The FieldBus went from Online to Offline. This is just a warning.

215

Page 216

EXXX "Text"

Information

Tool locked

Tool not ready

PF not ready

Acknowledg ement

Category

Short description (graphic display)

Event code

Event codes

1 / 2 / 3 / 4 ACK / - PFNR / - TNR / - LCK "Text" /-

E468

FieldBus Hardware Mismatch

3

-

-

TNR

-

E469 E470 E480

FieldBus Init Error FieldBus PCP error Channel Id not valid

3 2 4

ACK

PFNR

TNR TNR TNR

-

E481

Cell member registration failed

3

ACK

PFNR

TNR

-

E490

Cell Id not valid

4

ACK

PFNR

TNR

-

E491

Net member registration failed

3

-

-

TNR

-

The FieldBus module installed in PF 3000 is not the same FieldBus type as configured with TTPF. Change FieldBus module or configuration to get a match.

The channel Id configured is not within the limits permitted. The channel Id must configured between 1 and 20. The cell member registration failed because one cell member is already registered with the same channel Id. The cell Id configured is not within the limits permitted. The cell Id must configured between 1 and 999. The net member registration failed because one net member is already registered with the same cell Id.

E500-E599: Hardware errors TOOL E501 E502 E511

Tool overheated Tool service interval expired Tool-PF3000 size mismatch

2 3 4

ACK

PFNR PFNR

TNR TNR TNR

-

E512

Tool revision not supported by this drive SW Tool EEPROM corrupt – service tool Tool EEPROM corrupt – Motortune Tool commutation sensor error Rotor magnet remains out of range Tool maxtorque or Gear Ratio out of range Tool normalisation out of range Illegal data error (Current monitoring) Torque transducer error No transducer (sensor) Calibration not OK, offset outside limits Calibration not OK, CalVal outside limits Calibration not OK, Offset changed > 5% of max value since last calibration Calibration not OK, CalVal changed > 5% of max value since last calibration

4

ACK

PFNR

TNR

-

4 4 4 4 4

ACK ACK ACK ACK ACK

PFNR PFNR PFNR PFNR PFNR

TNR TNR TNR TNR TNR

-

4 2

ACK

PFNR PFNR

TNR TNR

-

2 2 2

ACK ACK ACK

PFNR PFNR PFNR

TNR TNR TNR

-

Cables to transducer cut off or shorted. Cables to transducer cut off or shorted. Calibration limits out of bounds.

2

ACK

PFNR

TNR

-

Calibration value outside limits.

2

-

-

-

-

2

-

-

-

-

Calibration not OK, Offset changed > 5% of max value since last calibration. Calibration not OK, calibration value changed > 5% of max value since last calibration.

E513 E514 E515 E516 E517 E518 E534 E535 E536 E537 E538 E539 E540

216

The tool is too hot the drive is disabled. Mismatch between the tool and the controller (for example S4/S7 tool connected to a S9 controller). The tool is supported by the drive (drive version too old).

Commutation sensor failure. Rotor magnet remains out of range.

Page 217

EXXX "Text"

E541

Other calibration error

Information

Tool locked

Tool not ready

PF not ready

Acknowledg ement

Category

Short description (graphic display)

Event code

Event codes

1 / 2 / 3 / 4 ACK / - PFNR / - TNR / - LCK "Text" /2

ACK

PFNR

TNR

-

3 3 2 4 3 4

ACK ACK ACK ACK

PFNR PFNR PFNR PFNR PFNR

TNR TNR TNR TNR TNR TNR

-

4

ACK

PFNR

TNR

-

4

ACK

PFNR

TNR

-

4 4 4 4 4

ACK ACK ACK ACK ACK

PFNR PFNR PFNR PFNR PFNR

TNR TNR TNR TNR TNR

-

4

ACK

PFNR

TNR

-

2

-

-

-

-

4

ACK

PFNR

TNR

-

E802 E803 E804 E805

Database incompatible with PF software NVRAM range check error NVRAM size check error Database is corrupt (PF Model unknown)

4 4 4 4

ACK ACK ACK ACK

PFNR PFNR PFNR PFNR

TNR TNR TNR TNR

-

E806 E807 E811 E821

Failed to read from NVRAM Failed to write to NVRAM DPRAM range check error No calibration ACC from control

2 2 4 4

ACK ACK

PFNR PFNR

TNR TNR

-

E822

No Job ACC from control

4

ACK

PFNR

TNR

-

E600-E699: Hardware errors DC3000/MC3000 E601 E602 E603 E604 E605 E611 E612 E613 E614 E615 E616 E617 E633 E634

Dcbus LO at start of rundown Dcbus HI during rundown DC3000 overheated 24V output error Dcbus HI at start of rundown DC3000 EEPROM corrupt (csum error) MC3000 EEPROM corrupt (csum error) Config1 EEPROM corrupt (csum error) FirmWare corrupt (csum error etc) Option definition HW/SW mismatch Current measurement offset error Current measurement gain error SW mismatch CC <-> MC: Too old MC SW SW mismatch CC <-> MC: Too old CC SW

DC voltage too low DC voltage too high The drive is too hot, drive disabled 24 V output disabled (overload or short circuit)

Firmware corrupt (check sum error)

E700-E799: Hardware errors E700

PF started

This error code is only visible in the error log and used when the PF3000 is started.

E800-E899: Software errors E801

This error is displayed after start -up when the RBU is missing, or when the RBU revision cannot be supported by the controller (e.g bronze RBU on a graph unit), or when the RBU license file is missing or cannot be read by the boot code.

Tightening initialisation phase failed. Hardware failure. Tightening initialisation phase failed. Hardware failure.

217

Page 218

EXXX "Text"

1 / 2 / 3 / 4 ACK / - PFNR / - TNR / - LCK "Text" /-

E823

No calibration result

4

ACK

PFNR

TNR

-

E824

Cycle abort timeout

2

-

-

-

-

E831

Autoset wrong angle

2

-

-

-

-

E832

Autoset small angle

2

-

-

-

-

E833

Autoset tight NOK result

2

-

-

-

-

E834

Autoset rejected Pset in CCW direction

2

-

-

-

-

E840

Feature Not Available In Software Revision

2

-

-

-

E851

Connection with Tools Net server lost

2

-

-

-

E855 E856

Connection fatal error Router unreachable

3

-

-

-

E857

3

-

-

-

E858

Reboot needed before changes take effect IP address already in use

3

ACK

-

-

-

E859

IP address collision

2

-

-

-

-

E860

Memory Allocation Error

2

-

-

-

-

E862

Ethernet overload Error

2

-

-

-

E863

IP Port already in use

3

-

-

-

218

Information

Tool locked

Tool not ready

PF not ready

Acknowledg ement

Category

Short description (graphic display)

Event code

Event codes

-

ACK

No calibration was received from the drive during the tightening initialisation phase (timeout 100 ms). No tightening result was received from the drive before the Cycle abort timeout. The Cycle Abort timer is configurable in the Pset. Auto set could not be executed, the angle results of the tightening performed were null. Auto set could not be executed, the angle results of the tightening performed were too small (lower than 15 degrees). The Auto set could not be executed, four NOK tightenings were performed. The Auto set was not allowed by the PF3000 for this Pset because the Pset was configured in the CCW direction. Auto set is only permitted on CW Pset. This error is displayed if when attempt is made to run multistage with a bronze version, or handle a Pset with a Pset ID larger than the max number of Pset (larger than 64 in a bronze version or larger than 250 in a silver or gold version). The connection with the Tools Net server was lost, the PF3000 is trying to reconnect. The Tools Net server might be down or it might be an Ethernet cable problem. The router programmed in the configuration setting could not be reached. Check the network configuration and in particularly the sub net mask and the default router. The configuration changes will not take effect before a system reboot. The IP address of this PF3000 is already in use by another system. Another system attempts to use the same IP address as this PF3000. It was not possible to allocate enough memory to allow the Tools Net process to set a result subscription. The Ethernet driver of the PF3000 is switched off due to an overloaded network. An attempt was made to bind a TCP or UDP socket to a port already in use. For instance, a customer protocol might be using the same port as ToolsTalk.

Page 219

EXXX "Text"

Information

Tool locked

Tool not ready

PF not ready

Acknowledg ement

Category

Short description (graphic display)

Event code

Event codes

1 / 2 / 3 / 4 ACK / - PFNR / - TNR / - LCK "Text" /-

E870

Syncmember registration failure

2

-

-

TNR

-

E871 E872

Syncmaster configuration failure Sync initialisation failure

2 2

-

PFNR -

TNR TNR

-

E873 E891 E892 E893 E894

Synchrotork not yet implemented Precondition Failed Postcondition Failed Check violation Software Warning

2 2 2 2 2

-

-

TNR TNR TNR TNR TNR

-

4 4 2

ACK ACK -

PFNR PFNR -

TNR TNR -

-

The sync member registration failed. Two sync members can have the same channel id or one PF3000 with a sync reference IP address is missing in the sync list. The master channel id is not first in the sync list. The tightening synchronisation initialisation failed. Check the CAN bus cable, check that all the sync members have the same active pset, check the external start bridge…

E900-E999: Errors MMI3000 E901 E902 E903

MMI Start -up Error Printer start -up error Incorrect ToolsTalk Version

The Tools Talk version is not compatible with the current PF3000 software.

END

219

Page 220

This page is a scan with no text; see it in the PDF.

Page 221 read from a scan by OCR; it may hold reading errors

Hardware Description

20 Hardware Description

20.1 Dimension Drawings 20.1.1 Power Focus 3000 Graph a, _ 30 _ Le. . © \€) \ al \ ca ° © = | o- @ | / 365 ly |/ = ne _.y is) 4 ee

221

Page 222 read from a scan by OCR; it may hold reading errors

Hardware Description

20.1.2 Power Focus 3000 Compact a | ‘ |} or ja In \ vou \ ‘ \ \ \ | ° | f Hr 4 -©o Oo mb | j / j | / / a vt | | if | if ,/ ! ee! Sa at

222