Page 303
Appendix E
25.1.3 Trend deviation alarm Trend deviation check and alarm are measured and compared against X-bar and the range for the currently used Pset. 7 points consecutively increasing 7 points consecutively decreasing 7 points consecutively above average ( X and / or R ) 7 points consecutively below average ( X and / or R ) 1 point outside X or R ± 2 sigma (sigma for the whole population) Point = subgroup The mean is the average of x and r ( X and R ). This means that the SPC trend alarms cannot function until the number of tightenings in the memory corresponds with the user-specified number of subgroup parameters.
25.1.4 Calculation of UCL and LCL Power Focus calculates recommended values for UCL and LCL. The operator can then choose if he wants to use these values or enter another value. Subgroup size, Subgroup frequency and Number of subgroups parameters are used in the calculations.
25.1.5 Calculation of X and R Power Focus calculates recommended values. The operator can then choose if he wants to use these values or enter another value. Subgroup size, Subgroup frequency and Number of subgroups parameters are used in the calculations.
303
Page 304
Appendix E
25.1.6 Calculation formulas When a stat display is requested, the whole memory will be calculated. This will also be done when shifting Pset. Power Focus controls the lowest and highest values. If some of these drop out from memory once it is full (first in – first out), the entire memory will be recalculated. The formula for group range is calculated after each completed subgroup. The formula for the statistic parameters used by Power Focus are as follows: Xi = value n = number of tightenings Min = minimum value from all the tightenings in the test series Max = maximum value from all the tightenings in the test series minl = minimum acceptable value maxl = maximum acceptable value Range = R = Max − Min 1 n
Mean = X = 1 ∑ X i n i =1
1 n 2 2 σ = sn−1 = X − nx ∑ n − 1 i−1 i
CR =
6*σ Maxl − Minl
CP =
Maxl − Minl 6*σ
Maxl − X X − Minl CPK = min , 3 * σ 3 *σ
304
Page 305
Appendix E Tightenings X1 X2 X3 X4 X5 X6 X7 X8 X9 X10 Xi Xi+1 Xi+2 Xi+3 Xi+4 Xi+5 Xi+6 Xi+7 Xi+8 Xi+9 Xi+10 Xi+11 Xi+12 Xi+13 Xi+14 Xi+.. ... A subgroup is a group of tightenings. Subgroup size is freely programmable and in the example above it is set to 5, which means that all values in the same group range from i to i+4. X-bar is the calculated average of the last completed subgroup. Subgroup size =Group size = z Grouprange = Wn = max[ X i+1 , X i+ 2 , , , , X i+ z ] − min[ X i+1 , X i +1 , , , , X i+ z ] Wn +1 = max[ X i+ z+1 , X i+ z+ 2 , , , , X i +2 z ] − min[ X i+ z+1 , X i+ z+ 2 , , , , X i + 2z ] n
W =
∑W j = n− 6
CAM = j
6 1746 . (max l − min l ) 6 *W
305
Page 306
Appendix E The formula for CAM is calculated using the first 6 subgroups. After that, a new calculation is made using each completed subgroup in conjunction with the last 6 subgroups. 1 n X = 1 ∑ xi n i=1 1 n R = 1 ∑ ri n i =1
XUCL = X + ( A2 ∗ R ) XLCL = X − ( A2 ∗ R ) RUCL = D4 ∗ R RLCL = D3∗ R
A2 , D3andD4 are tabular constants and depend on the Subgroup size.
306
Page 307
Appendix E
25.1.7 Constants for calculation of SPC variables Constants for Calculation of SPC Variables Subgroup Size
Divisors for Estimation Of Standard Dev.
Factors for Control Limits
N 2 3 4 5
D2 1.13 1.69 2.06 2.33 c4 0.798 0.886 0.921 0.940
A2 1.88 1.02 0.73 0.58
D3 -
D4 3.27 2.57 2.28 2.11
A3 2.66 1.95 1.63 1.43
B3 -
B4 3.27 2.57 2.27 2.09
6 7 8 9 10
2.53 2.70 2.85 2.97 3.08
0.952 0.959 0.965 0.969 0.973
0.48 0.42 0.37 0.34 0.31
0.08 0.14 0.18 0.22
2.00 1.92 1.86 1.82 1.78
1.29 1.18 1.10 1.03 0.98
0.03 0.12 0.19 0.24 0.28
1.97 1.88 1.82 1.76 1.72
11 12 13 14 15
3.17 3.26 3.34 3.41 3.47
0.975 0.978 0.979 0.981 0.982
0.29 0.27 0.25 0.24 0.22
0.26 0.28 0.31 0.33 0.35
1.74 1.72 1.69 1.67 1.65
0.93 0.89 0.85 0.82 0.79
0.32 0.35 0.38 0.41 0.43
1.68 1.65 1.62 1.59 1.57
16 17 18 19 20
3.53 3.59 3.64 3.69 3.74
0.984 0.985 0.985 0.986 0.987
0.21 0.20 0.19 0.19 0.18
0.36 0.38 0.39 0.40 0.42
1.63 1.62 1.61 1.60 1.59
0.76 0.74 0.72 0.69 0.68
0.45 0.47 0.48 0.50 0.51
1.55 1.53 1.52 1.50 1.49
21 22 23 24 25
3.78 3.82 3.86 3.90 3.93
0.988 0.988 0.989 0.989 0.990
0.17 0.17 0.16 0.16 0.15
0.42 0.43 0.44 0.45 0.46
1.58 1.57 1.56 1.55 1.54
0.66 0.65 0.63 0.62 0.61
0.52 0.53 0.55 0.56 0.57
1.48 1.47 1.46 1.45 1.44
307
Page 308
Page 309
Abbreviations
26
Abbreviations
X <= => σ a µ
The centre line The mean The mean of the average Arrow (button) Sigma (standard deviation) Alpha (often a symbol for angle) Mu (the values of the mean)
A AC Ack Admin Ang con Ang mon ASL
Ampere Alternating Current Acknowledged Administration Angle control Angle monitoring Atlas Service Literature
CAN CC CCW CD Ch CL Config CW
Controller area network Control card Counter-clockwise Compact disc Channel Clear (button) Configuration Clockwise
DC Deg Dig in DSP
Direct Current Degrees Digital input Digital signal processor.
ft.lb
Foot pound
GFI
Ground Fault Interrupter
HW Hz I/O
Hardware Hertz (unit of frequency) Input/output
R X
309
Page 310
Abbreviations ID in.lb IR kpm
Identification Inches pound Infra red Kilo pound meter
LCD LED
Liquid Crystal Display Light Emitting Diode
MC
Motor card n Nm No. NOK nxOK
Number (of values) Newton meter Number Not approved (tightenings) Number of approved (tightenings)
OK
Approved (tightenings)
PF PLC PROG Pset PVT
Power Focus Programmable Logic Controller Program (button) Parameter set Prevailing torque
R chart RAM RAS RBU rpm RS232
Range chart Random Access Memory Remote Access Server Rapid Backup memory Revolutions per minute FieldBus, serial communication link
S4/S7/S9 SM SPC STAT SW
Motor sizes in Tensor-S tools Sync Reference Statistic Parameter Control Statistic (button) Software
310
Page 311
Abbreviations Tq Tq con Tq mon TTPF
Torque Torque control Torque monitoring ToolsTalk Power Focus (SW)
UCL UTL
Upper control limit Upper tolerance limit
V VIN
Volt Vehicle Identification Number
X-bar X-bar-bar
The mean The average of means z subgroup size, group size
311