Page 303

Appendix E

25.1.3 Trend deviation alarm Trend deviation check and alarm are measured and compared against X-bar and the range for the currently used Pset. 7 points consecutively increasing 7 points consecutively decreasing 7 points consecutively above average ( X and / or R ) 7 points consecutively below average ( X and / or R ) 1 point outside X or R ± 2 sigma (sigma for the whole population) Point = subgroup The mean is the average of x and r ( X and R ). This means that the SPC trend alarms cannot function until the number of tightenings in the memory corresponds with the user-specified number of subgroup parameters.

25.1.4 Calculation of UCL and LCL Power Focus calculates recommended values for UCL and LCL. The operator can then choose if he wants to use these values or enter another value. Subgroup size, Subgroup frequency and Number of subgroups parameters are used in the calculations.

25.1.5 Calculation of X and R Power Focus calculates recommended values. The operator can then choose if he wants to use these values or enter another value. Subgroup size, Subgroup frequency and Number of subgroups parameters are used in the calculations.

303

Page 304

Appendix E

25.1.6 Calculation formulas When a stat display is requested, the whole memory will be calculated. This will also be done when shifting Pset. Power Focus controls the lowest and highest values. If some of these drop out from memory once it is full (first in – first out), the entire memory will be recalculated. The formula for group range is calculated after each completed subgroup. The formula for the statistic parameters used by Power Focus are as follows: Xi = value n = number of tightenings Min = minimum value from all the tightenings in the test series Max = maximum value from all the tightenings in the test series minl = minimum acceptable value maxl = maximum acceptable value Range = R = Max − Min 1 n

Mean = X = 1 ∑ X i n i =1

1 n 2 2 σ = sn−1 = X − nx ∑ n − 1 i−1 i

CR =

6*σ Maxl − Minl

CP =

Maxl − Minl 6*σ

Maxl − X X − Minl CPK = min , 3 * σ 3 *σ

304

Page 305

Appendix E Tightenings X1 X2 X3 X4 X5 X6 X7 X8 X9 X10 Xi Xi+1 Xi+2 Xi+3 Xi+4 Xi+5 Xi+6 Xi+7 Xi+8 Xi+9 Xi+10 Xi+11 Xi+12 Xi+13 Xi+14 Xi+.. ... A subgroup is a group of tightenings. Subgroup size is freely programmable and in the example above it is set to 5, which means that all values in the same group range from i to i+4. X-bar is the calculated average of the last completed subgroup. Subgroup size =Group size = z Grouprange = Wn = max[ X i+1 , X i+ 2 , , , , X i+ z ] − min[ X i+1 , X i +1 , , , , X i+ z ] Wn +1 = max[ X i+ z+1 , X i+ z+ 2 , , , , X i +2 z ] − min[ X i+ z+1 , X i+ z+ 2 , , , , X i + 2z ] n

W =

∑W j = n− 6

CAM = j

6 1746 . (max l − min l ) 6 *W

305

Page 306

Appendix E The formula for CAM is calculated using the first 6 subgroups. After that, a new calculation is made using each completed subgroup in conjunction with the last 6 subgroups. 1 n X = 1 ∑ xi n i=1 1 n R = 1 ∑ ri n i =1

XUCL = X + ( A2 ∗ R ) XLCL = X − ( A2 ∗ R ) RUCL = D4 ∗ R RLCL = D3∗ R

A2 , D3andD4 are tabular constants and depend on the Subgroup size.

306

Page 307

Appendix E

25.1.7 Constants for calculation of SPC variables Constants for Calculation of SPC Variables Subgroup Size

Divisors for Estimation Of Standard Dev.

Factors for Control Limits

N 2 3 4 5

D2 1.13 1.69 2.06 2.33 c4 0.798 0.886 0.921 0.940

A2 1.88 1.02 0.73 0.58

D3 -

D4 3.27 2.57 2.28 2.11

A3 2.66 1.95 1.63 1.43

B3 -

B4 3.27 2.57 2.27 2.09

6 7 8 9 10

2.53 2.70 2.85 2.97 3.08

0.952 0.959 0.965 0.969 0.973

0.48 0.42 0.37 0.34 0.31

0.08 0.14 0.18 0.22

2.00 1.92 1.86 1.82 1.78

1.29 1.18 1.10 1.03 0.98

0.03 0.12 0.19 0.24 0.28

1.97 1.88 1.82 1.76 1.72

11 12 13 14 15

3.17 3.26 3.34 3.41 3.47

0.975 0.978 0.979 0.981 0.982

0.29 0.27 0.25 0.24 0.22

0.26 0.28 0.31 0.33 0.35

1.74 1.72 1.69 1.67 1.65

0.93 0.89 0.85 0.82 0.79

0.32 0.35 0.38 0.41 0.43

1.68 1.65 1.62 1.59 1.57

16 17 18 19 20

3.53 3.59 3.64 3.69 3.74

0.984 0.985 0.985 0.986 0.987

0.21 0.20 0.19 0.19 0.18

0.36 0.38 0.39 0.40 0.42

1.63 1.62 1.61 1.60 1.59

0.76 0.74 0.72 0.69 0.68

0.45 0.47 0.48 0.50 0.51

1.55 1.53 1.52 1.50 1.49

21 22 23 24 25

3.78 3.82 3.86 3.90 3.93

0.988 0.988 0.989 0.989 0.990

0.17 0.17 0.16 0.16 0.15

0.42 0.43 0.44 0.45 0.46

1.58 1.57 1.56 1.55 1.54

0.66 0.65 0.63 0.62 0.61

0.52 0.53 0.55 0.56 0.57

1.48 1.47 1.46 1.45 1.44

307

Page 308

This page is a scan with no text; see it in the PDF.

Page 309

Abbreviations

26

Abbreviations

X <= => σ a µ

The centre line The mean The mean of the average Arrow (button) Sigma (standard deviation) Alpha (often a symbol for angle) Mu (the values of the mean)

A AC Ack Admin Ang con Ang mon ASL

Ampere Alternating Current Acknowledged Administration Angle control Angle monitoring Atlas Service Literature

CAN CC CCW CD Ch CL Config CW

Controller area network Control card Counter-clockwise Compact disc Channel Clear (button) Configuration Clockwise

DC Deg Dig in DSP

Direct Current Degrees Digital input Digital signal processor.

ft.lb

Foot pound

GFI

Ground Fault Interrupter

HW Hz I/O

Hardware Hertz (unit of frequency) Input/output

R X

309

Page 310

Abbreviations ID in.lb IR kpm

Identification Inches pound Infra red Kilo pound meter

LCD LED

Liquid Crystal Display Light Emitting Diode

MC

Motor card n Nm No. NOK nxOK

Number (of values) Newton meter Number Not approved (tightenings) Number of approved (tightenings)

OK

Approved (tightenings)

PF PLC PROG Pset PVT

Power Focus Programmable Logic Controller Program (button) Parameter set Prevailing torque

R chart RAM RAS RBU rpm RS232

Range chart Random Access Memory Remote Access Server Rapid Backup memory Revolutions per minute FieldBus, serial communication link

S4/S7/S9 SM SPC STAT SW

Motor sizes in Tensor-S tools Sync Reference Statistic Parameter Control Statistic (button) Software

310

Page 311

Abbreviations Tq Tq con Tq mon TTPF

Torque Torque control Torque monitoring ToolsTalk Power Focus (SW)

UCL UTL

Upper control limit Upper tolerance limit

V VIN

Volt Vehicle Identification Number

X-bar X-bar-bar

The mean The average of means z subgroup size, group size

311