Page 293

Appendix D

24.7

InterBus

Introduction to InterBus The InterBus is normally used for industrial automation applications, such as valve, sensor and I/O unit control. InterBus is used in many different types of industry, including: Automobile Industry, Food Industry, Building Automation, Plant Construction, Paper Converting, Wood Processing and Process Engineering. InterBus has a user organisation called the InterBus Club. The organisation assists members on a wide variety of matters concerning InterBus. For more information, contact the InterBus Club: http://www.interbusclub.com Protocol & Supported Functions The media used by Interbus is a shielded copper cable consisting of three twisted pairs. Two of these pairs are used for the bus connection and in the last pair only one cable is used. This cable is used to earth the bus. The baud rate for the bus is 500 kbit/s with a total amount of data of 4096 I/O points. The Power Focus InterBus module is to be used on InterBus Remote Bus networks. In applications where it is necessary to exchange large amounts of data and where a parallel application interface is required, InterBus is the preferred option. InterBus has two ways of exchanging data. One through fast cyclical I/O data, called process data. The other is a somewhat slower protocol called PCP, which is mainly used for configuring and setting the parameters of a device. The Power Focus InterBus module supports up to 10 words on the bus, out of which none, one, two or four words may be selected to act as the PCP – channel, necessary if the PCP-protocol required. The PCP version supported by the module is version 2.0, which is fully backwards compatible. Note! When using InterBus master boards where the PCP channel is not supported, the maximum input and output is 20 Bytes in and 20 Bytes out.

293

Page 294

Appendix D Power Focus Interbus description Physical Interface

Transmission media: InterBus two differential lines. Topology: Ring Structure. FieldBus connectors: 9 pin male DSUB. Cable: Shielded copper cable, Three Twisted pair. Isolation: The bus is galvanically separated from the other electronics with two DC/DC Converters. Bus signals are isolated via opto couplers. ASICs and circuits: Module is based on SUPI 3 and SRE1 chip from Phoenix Contact. Facts in brief

The table below gives a brief summary of facts for Power Focus Interbus module. Variable Node Address Number of nodes in an Interbus network Baud rate Process string length Parameter string length (send with PCP) PCP length Parameter data index ID code (in PLC side)

Limits Auto select 500 kbit/sec <= 20 bytes 122 byte – Process string length * 0, 1, 2, 4 Words 0x6000 R/W + I (I = 0, 1, …) 0x6040 RO + I (I = 0, 1, …) PCP 0 = 3 PCP 1 = 0xF3 PCP 2 = 0xF0 PCP 4 = 0xF1

* The string length in the Power Focus 3000 is limited to 122 bytes. Interbus standard allows 512 bytes.

294

Page 295

Appendix D Hardware

BUS-IN (9-pin Dsub male) BUS-OUT (9-pin Dsub female) Pin Housing 1 2 3 4 5 6 7 8 9

Name PE DO1 DI1 GND Not used Not used /DO1 /DI1 Not used Not used

Pin Housing 1 2 3 4 5 6 7 8 9

Name PE DO2 DI2 GND Not used GND /DO2 /DI2 Not used RBST

Note! Always connect RBST to GND if it is not the last module on the bus. If the RBST is not connected to GND on the output connector, the Power Focus InterBus module will terminate the outgoing bus.

295

Page 296

Appendix D Functionality of the indicator LEDs LED# 1. RBDA 2. TR

Name Remote Bus DisAble Transmit/Receive

3. CC

Cable Check

4. BA

Bus Active

Description Active RED when outgoing remote bus is switched off Active GREEN when PCP communication is carried out over the InterBus (0.6 s hold time to be visual, Retriggerable). Active GREEN if the cable connection is good and the InterBus Master is not in RESET Active GREEN, is monitoring Layer 2

Icon file

Contact you local Atlas Copco representative to get a copy of the Icon file for Power Focus. This file can be used to have a PF Icon in the PLC configuration SW. File name: pf3intb.ico

296

Page 297

Appendix D

24.8

ModBusPlus

ModBusPlus is a local area network system designed for industrial control and monitoring applications, developed by Modicon, Inc. The network enables programmable controllers, host computers and other devices to communicate throughout plants and substations. ModBusPlus transfers fast data for motor controllers, MMI, I/O units and other industrial equipment. ModBusPlus has an international user organisation called Modicon Inc. General technical questions regarding the FieldBus should be addressed to your local ModBusPlus User Group in the first instance. A contact address list is available from the ModBusPlus Internet site; www.modicon.com. Power Focus ModbusPlus description Physical Interface

• • • • • •

Transmission media: ModBusPlus one differential line (RS-485 twisted pair) and shield. Topology: Token Bus Structure, virtual token ring. FieldBus connectors: 9 pin female DSUB. Cable: Shielded copper cable, One Twisted pair Isolation: The bus signals are separated from the other electronics with a transformer according to ModBusPlus interface description. ASIC’s and circuits: Module is based on chip-set and software from Modicon Inc.

Mechanical overview

ModBusPlus module is a host device. This host device can be read and written to from another ModBusPlus host device or controller. ModBusPlus module will not initiate any Point-to-point communication to other nodes, it will only respond to incoming commands. It can although broadcast Global data to all nodes on the network. Protocol and Supported Functions

ModBusPlus has two ways of exchanging data. One through fast cyclic I/O data called Global data, and one through a somewhat slower ModBus protocol for point-to-point parameter data transfer. The Maximum Global Data is 32 words on the bus. The point-to-point data transfer is handled by using one of the following ModBus functions Read holding Registers, PreSet Single Register and PreSet multiple Registers all 40000 registers.

297

Page 298

Appendix D Facts in brief

The table below shows a brief summary of facts for Power Focus ModBusPlus module. Variable Limits Information Node Address 1 - 64 The node address cannot be changed during operation. Source Address 1 - 64 The node address cannot be changed during operation. Number of nodes in a ModBusPlus Max 32 (with repeaters 64) network Bus length Max 2000 m with repeaters Bus cable length Max 500 m Data address 40001+ I (I = 0, 1, …)* From This address is based on PF words. 41025 + I (I = 0, 1, …)* To PF Baud rate Automatic (1Mbit/s) Automatically set from PLC at connection. Data to PF total length 0 - 122 bytes ** Must be the same in PF and PLC. Data from PF total length 0 - 122 bytes ** Must be the same in PF and PLC. Global string length (To/From PF ) 0 - 64 bytes Must be the same in PF and PLC. Host Firmware Rev. 77 * Global Data From PF Data in the module starts from address 40001 and Point-to-Point Data starts immediately thereafter. Global Data To PF data in the module starts from address 41025 and Point-to-Point Data starts immediately thereafter. For example, If To PF string length is 8 bytes and To PF Global string length is 4 bytes, the Global data are mapped to address 41025 and 41026, the point-to-point data are mapped to address 41027 and 41028. ** The string length is in PF limited to 122 bytes. ModBusPlus standard allows 64 bytes global data and 250 bytes point-to-point data.

298

Page 299

Appendix D Hardware LED 1: Not used LED 2: Error LED 3: MBP Active LED 4: MBP Init

Functionality of the indication LEDs

The module is equipped with four bi-colour LEDs, used for debugging purposes. The function of the LEDs is described in the table and figure below. Name Error (LED 2)

Colour Red

Function Indicates that the communication is not OK. Turned Off – communication OK

MBP Active (LED 3)

Green

MBP Init (LED 4)

Green

Indicates different Node Status: Flashing every 160 ms – This node works normally, receiving and passing token. Flashing every 1 s – This node is in Monitor_Offline status. 2 Flashing, off 2 s – This node is in MAC_IDLE never receiving-token status. 3 Flashing, off 1.7 s – This node is not hearing any other nodes. 4 flashing, off 1.4 s – This node has heard a valid packet that has a duplicated-node address sent from another node on the network, using the same Node ID. Indicates that the peer interface is initialised Turned Off – peer interface is not initialised

FieldBus Connectors

ModBusPlus recommends the use of a 9 pin female D-sub connector. Depending on the protection class and type of application, other connector designs may also be used. Connector 9-pin female DSUB Pin 1 2 3 4

Name Cable shielding Line-B Line-A PE

299

Page 300

Appendix D Node Address

Node address is set with the first dip switch on the FieldBus module, allowing address settings from 1-64 in binary format. If the set node address is from SW1, ModBusPlus takes SW node address regardless of hardware switch position. 1 MSB ON ON ON OFF OFF

2

3

4

5

6

ON ON ON OFF OFF

ON ON ON OFF OFF

ON ON ON OFF OFF

ON ON OFF OFF OFF

ON OFF ON ON OFF

Function LBS Node address set to 1 Node address set to 2 Node address set to 3 Node address set to 63 Node address set to 64

Note! The node address cannot be changed during operation. Source Address

Source address is set using the second dip switch (the one close to LED) on the FieldBus module, this enables address settings from 1-64 in binary format. If the set source address is from SW2, ModBusPlus takes SW source address regardless of hardware switch position.

1 MSB ON ON ON OFF OFF

2

3

4

5

6

ON ON ON OFF OFF

ON ON ON OFF OFF

ON ON ON OFF OFF

ON ON OFF OFF OFF

ON OFF ON ON OFF

Function LBS Source address set to 1 Source address set to 2 Source address set to 3 Source address set to 63 Source address set to 64

Note! The source address cannot be changed during operation. File and Icon

It is not necessary for ModBusPlus to install a special file to recognise our product and it does not support icon files.

300

Page 301

Appendix E

25

Appendix E: Statistics

25.1

Statistics in Power Focus 3000

The statistics are measured after each tightening and can be shown on the display in real time and be sent to a PC via serial or Ethernet connection. It is also possible to send statistical reports to a printer for print out. There is a stat alarm LED on the front panel of the Power Focus. Statistics are calculated based on the following result parameters: Result Torque Angle

Unit Nm* Deg

Description Final torque in selected tq presentation unit. Final angle in degrees.

* = Other units can be used. The following statistical results are calculated and displayed for torque and angle parameters: Results # Results Min Max R Low OK High

X σ X -3 σ X +3 σ 6σ Cr Cp Cpk Cam Sub-group results Min Max R x σ

Description Total number of results that the stat calculations are based on for the analysed Pset. Lowest result in analysed Pset Highest result in analysed Pset Range (Max – Min) % low tightenings in analysed Pset % OK tightenings in analysed Pset % high tightenings in analysed Pset The mean value for the selected Pset Sigma. Shows the calculated standard deviation. Mean - 3 sigma Mean + 3 sigma 6 x sigma Cr is a calculated viability number. (capability). The lower value, the better process. Cp is a viability factor. The higher value the better process. Cpk is a viability factor. The higher value the better process.

Lowest result in the latest completed subgroup Highest result in the latest completed subgroup Range for the latest completed subgroup Average value for the latest completed subgroup Sigma for the latest completed subgroup

Other definitions

R

X

Average of subgroup range (number of subgroups) Average of subgroup average (number of subgroups)

301

Page 302

Appendix E

25.1.1 Statistical process control In order to rapidly detect changes in the process, Power Focus is equipped with a number of statistical alarm limits based on the x and R calculations for torque and angle. SPC functions are used on torque and angle. All checks are performed on the Pset that the tool is currently running with. If any of the following criteria are true the stat alarm light, and a relay (if used), is activated. The tool may still run even if an alarm is issued. The alarm is only a warning. The alarm signals remain active until the process falls within all limits again or the result memory is cleared. This means that the alarm does not switch off during tightening.

25.1.2 Statistic alarm x > UCL x < LCL R > UCL R < LCL Cp < 2.0 Cpk < 1.33

SPC x and r compared with LCL / UCL alarms cannot function until the LCL and UCL have been programmed.

302