Page 23
User Interfaces
3
User Interfaces
Compact
Graph
ToolsTalk
This section describes the different interfaces, which are used to monitor and control the Power Focus. There are three different user interfaces: -
Power Focus 3000 Compact Power Focus 3000 Graph ToolsTalk
The Compact and the Graph are two different Power Focus 3000 models and ToolsTalk is a software package that is used for monitoring and controlling the Power Focus 3000 via a PC or a laptop. The Compact and the Graph have similar functionality and capacity. The only difference is the user interface.
23
Page 24
User Interfaces
3.1
Power Focus 3000 Compact
Power Focus 3000 Compact can be programmed either via a Graph, ToolsTa lk or a preprogrammed RBU. It can also be programmed directly via the unit’s Auto Set function. Except for differences in the user interface, the Compact possesses the same functionality and capacity as the Graph model. For a description of the connections on the Compact back panel, see chapter 20, Hardware Description.
3.1.1
Front Panel
The front panel of the Power Focus Compact consists of a display, indicator lights, buttons and a red and white power switch. There is also an IR window, which can be used in conjunction with an IR key to lock and unlock the buttons on the front panel.
1 2
1. Display The front panel contains a 4-digit, 7-segment display. 2. IR Window The IR window can be used in conjunction with an IR-key to lock and unlock the buttons on the front panel. 3. Power Switch Red and white power switch.
3
24
Page 25
User Interfaces
3.1.2
Indicator Lights 5
1 2 3 4
6 7 8
1. 2. 3.
n x OK OK NOK
4. 5. 6.
JOB OK ALARM PROG CONTROL
7. 8.
AUTO SET STAT
1. n x OK The n x OK light indicates when the number of approved rundowns corresponds to the number (batch size) programmed into the Power Focus 3000. The indicator remains active until the next cycle starts. 2. OK The OK light indicates when the result of the rundown is within the specified limits. The indicator remains active until the next cycle starts. 3. NOK The NOK light indicates when the result of the rundown falls outside the specified limits. The light is active until the next cycle starts. 4. JOB OK The JOB OK light indicates when the result of the Job is finished and within the specified limits. The light remains active until the next cycle starts or when the system is reset.
25
Page 26
User Interfaces 5. ALARM The ALARM indicates that an alarm message needs to be acknowledged. The light is active until the message is cleared. The alarm light can also flash indicating active alarm that does not need to be acknowledge, i. e. service indicator alarm. 6. Programming Control If the Power Focus 3000 is in programming mode the Programming Control light (illustrated by an opened padlock) flashes green. Programming Control can be undertaken via the unit itself, via a Graph or via ToolsTalk. A steady green light indicates that the programming buttons on the front panel are unlocked. If the Power Focus 3000 Compact is not in programming mode, the only buttons on the unit that can be used are Question Mark and Enter. (If key is unlocked, steady green, any key can be accessed.) 7. Auto Set The Auto Set light indicates when the Auto Set programming function is active. The light goes off when Auto Set is finished. 8. STAT The STAT light indicates when the calculated values fall outside statistical control limits. The light remains active until the values are within the control limits or the memory has been reset.
26
Page 27
User Interfaces
3.1.3
Keys
1 5 3
1.
Plus Button (+)
2. 3. 4.
Minus Button (-) Function Button Auto Set
5. 6.
Question Mark Enter
2
4 6
Plus Button (+) The Plus Button (+) is used to navigate through menus on the display and increase numbers. Minus Button (-) The Minus Button (-) is used to navigate through menus on the display and decrease numbers. Function Button (F) Press the Function button to display functions F1 - F5: F1 - Setting Final Target value 1. “F1”/”Ft” alternates in the display. If no Pset is selected “F1”/”----“ is displayed. 2. Press Enter to select the new Final Target value. Change the value by pressing the +/– keys. 3. Press Enter to save and exit. Press F to exit (no save).
27
Page 28
User Interfaces F2 - Setting Torque Tune Factor 1. “F2”/”tunE” alternates in the display if the selected Control Strategy is equals to DS control. Otherwise “F2”/”----“ is displayed. 2. Press Enter to access the Torque Tune Factor. Change the value by pressing the +/– keys (range 80% - 220%, default value 100%). 3. Press Enter to save and exit. Press F to exit (no save). F3 - Motor tuning 1. “F3”/”tool” alternates in the display. 2. Press Enter to activate the Motor Tuning process. When the Motor Tuning is being performed, the display will show the progress in percent (starting with 0). 3. Press the Tool Trigger Button to start Motor Tuning. 4. Press F at any time to abort the Motor Tuning process. 5. When Motor tuning process ends, “F3”/”tool” starts alternating in the display. F4 - Selecting Pset 1. “F4”/”Pset” alternates in the display if the Pset Select Source is Keyboard. Otherwise “F4”/”---“ is displayed. 2. Press Enter to access the available Psets. Browse existing Psets by pressing the +/- keys. 3. Press Enter to select a Pset and exit. 4. Press F to exit (no selection). F5 - Setting Batch count 1. “F5”/”batS” alternates in the display, indicating that a Pset is selected. Otherwise “F5”/”----“ is displayed. 2. Press Enter to access the Batch Size value (range 0 – 99). Change the Batch Size value by pressing the +/- keys. 3. Press Enter to save and exit. 4. Press F to exit (no save).
28
Page 29
User Interfaces Auto Set 1. Press the Auto Set button to enter Auto Set programming mode. “Aset”/”Ft” alternates in the display and the Auto Set led goes on. 2. Press Enter to access the Final Target value. Change the Final Target value (if required) by pressing the +/- keys. 3. Press Enter to select the Final Target value. “Aset” is shown in the display. 4. Perform a number of tightenings. When Auto Set is ready, the selected Pset number is displayed and Auto Set led goes out. 5. To abort Auto Set press the Auto Set button (exit and no save). Question Mark Pressing the Question Mark button will display the following information: Power Focus model Model type alternates with software version (G = Gold, S = Silver and B = Bronze). (“rBu” toggle with RBU type.) SW version The entire program code alternates with version number. (“rEL” with version number roll on the display from right to left.) Motor type “Type” alternates with type number, which is either 4, 7 or 9. (“tYPE” alternatives with tool type and number, e.g. S7.) Current Pset “Pset” alternates with the current Pset ID, e.g. “P27”. Current Job “Job” alternates with the current Job ID, e.g. “J3”. Note! The Question Mark button is always unlocked. 6. Enter The Enter button is used to execute selected functions and for error acknowledgement. Note! The Enter button is always unlocked.
29
Page 30
User Interfaces
3.2
Power Focus 3000 Graph
Power Focus 3000 Graph can be programmed in a variety of ways: manually setting parameters, by a pre-programmed RBU, by another Graph or by using ToolsTalk. It can also be programmed via built- in functions Quick Programming and Auto Set [see chapter 7; Parameter Set]. The Graph can supervise all other units on a network (i.e. acting as the “Cell Master”). Except for differences in the user interface, the Graph possesses the same functionality and capacity as the Compact model. For a description of the connections on the Graph back panel, see Hardware Description, chapter 20.
3.2.1
Front Panel
The front panel of the Power Focus Graph (below) contains of a display (1), indicator lights (2), keys (3) and a power switch (5). There is also an IR Window (4), which can be used in conjunction with an IR key to lock and unlock the keys on the front panel.
1. Display 2. Indicator lights 3. Keys
4. IR-Window
5. Power Switch
30
Page 31
User Interfaces
3.2.2
Indicator Lights
1
5
2 3
6 7
4
8
1. 2.
OK NOK
5. 6.
ALARM STAT
3. 4.
N X OK JOB OK
7. 8.
PROG. CONTROL AUTO SET
The eight light emitting diodes (LEDs) on the front panel of the Power Focus Graph monitor the status of the controller. The lights always show the results from the tool currently in use. The indicator lights will light up for a short while when the power on the Graph is turned on. 1. OK The OK light indicates when the result of the rundown is within the specified limits. The indicator remains active until the next cycle starts. 2. NOK The NOK light indicates when the result of the rundown falls outside the specified limits. The light is active until the next cycle starts. 3. n x OK The n x OK light indicates when the number of approved rundowns corresponds to the number (batch size) programmed into the Power Focus 3000. The indicator remains active until the next cycle starts.
31
Page 32
User Interfaces 4. JOB OK The JOB OK light indicates when the result of the Job is finished and within the specified limits. The light remains active until the next cycle starts or when the system is reset. 5. ALARM The ALARM indicates that an alarm message needs to be acknowledged. The light is active until the message is cleared. The alarm light can also flash indicating active alarm that does not need to be acknowledge, i. e. service indicator alarm. 6. STAT The STAT light indicates when the calculated values fall outside statistical control limits. The light remains active until the values are within the control limits or the memory has been reset. 7. Programming Control If the Power Focus is in programming mode, the green Program Control light (illustrated by an opened padlock) flashes. Program Control can be undertaken via the unit itself, via a Graph or via ToolsTalk. A steady light indicates that the programming keys on the front panel are unlocked. 8. Auto Set The Auto Set light indicates that the Auto Set programming function is active. The light goes off when Auto Set is finished.