Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual · part 5 of 33

Power Focus 3000: Control and Drive Unit for TENSOR-S Electric Nut Runners: User Interfaces, pages 33 to 42

Pages 33 to 42 of 315, from Power Focus 3000: Control and Drive Unit for TENSOR-S Electric Nut Runners

The original document is the PDF (7.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Atlas Copco PF3007-C-HW and Atlas Copco PF3007-G-HW

Page 33

User Interfaces

3.2.3

Keys

1

8

2

9 10

3 4

11

5

12

6 7

13

1.

Soft KEYS

8.

PROG

2.

RESULT

9.

ARROW KEYS

3.

CHAN

4.

P SET

10. KEYS with numbers and letters

5.

PRINT

11. Cl

6. 7.

Question mark KEY CANCEL KEY

12. Enter 13. OK

1. Soft keys The function of these five soft keys varies, depending on what is shown in the lower edge of the display. The soft keys can be locked for security reasons. 2. RESULT Press the RESULT key to exit programming mode and go back to the result monitor. For further information, see the chapter entitled "DISPLAY". 3. CHAN The CHAN keys are used to select channels in a Cell to program or to display results from. The display shows the Cell Member identity in the upper left corner. If the key is pressed for more than one second, a list appears with all available channels in the Cell.

33

Page 34

User Interfaces 4. P SET Press the P SET keys to select which Pset (or Job) to program or to display results from. If the key is pressed for more than one second, a list appears with all available Psets. If Pset select source is set to “keyboard”, and the display is in Result Mode 1, running Pset can be change from the Pset key on Graph front panel. 5. PRINT Press the PRINT key when you want to print a report. The available choices are shown in a list where the current object is selected. The printer must be connected to the parallel port on the back panel of the Power Focus Graph. 6. Question mark Press the Question Mark key to display available information, e.g. program version number, RBU type, etc. 7. CANCEL The CANCEL key cancels the last entry made when programming, closes current menu tree level and opens up the next higher level. If changes have been made, you will be prompted to cancel or store. 8. PROG Press the PROG key to enter Programming mode. This will bring up the programming tree. For further information, see the chapter entitled "DISPLAY". Note! It is possible to perform tightenings while programming. However, changes will not take effect during a tightening in progress. 9. Arrow keys Use the four arrow keys to move the cursor around the menu trees and lists. -

34

The right arrow key opens the next menu tree level down, enters a parameter field or scrolls right through columns. The left arrow key closes the shown level, returns to the higher level or scrolls left through columns. The up and down arrow keys are used to move the cursor up and down in programming trees or lists. The left and right arrow keys can also be used to move the cursor in parameter field.

Page 35

User Interfaces 10. Keys with numbers and letters When used for text entry the number on the key appears after scrolling through the letters (press the key several times). Special characters occur depending on selected language. ABC

DEF

GHI

7

8

9

JKL

MNO

PQR

4

5

6

STU

VWX

YZ

1

2

3

0

.

These keys have different functions depending on when they are used. In Pop- up windows, List menus, etc., a press on one of these keys will select the corresponding entry the list (only digits). No enter is needed. In an Input menu, a press on one of these keys will print out a letter or number. Several key presses will toggle the letters. For example: Press on the "7"key will make the letter scroll in this order: ‘abcABC7’. Language specific letters can be found on the “0” key.

11. Cl Clear key. In result mode, this key removes the most recent result from the memory in the used Pset. If you are in the programming menu (in a parameter field), pressing the Clear key will remove the most recently entered character/number. 12. ENTER Press the Enter key to activate a selection, end an entry or open the next level in a menu tree. 13. OK Press the OK key to confirm programming or acknowledge messages.

35

Page 36

User Interfaces

3.2.4

Display

The Power Focus ¼ VGA Display monitors results and programming. It can be configured to show information from any Power Focus within a Cell. Result mode – last result During start-up, the Power Focus Graph will automatically enter Last Result Mode (the display will show the most recent result for one channel). The figure below shows the Graph display in Result mode. Note! This is only an example (all selection fields can be configured in Cset). G H

I

J K

L

F E

M

D

A

36

B

C

Page 37

User Interfaces A

B

C

D

E

F G

H

I J K

L M

View

(Soft key) Pull- up menu for switching between result views. Available views are; Last Results, Statistics, Stat Chart, Trace, Job, Sync, All (results) and Event log -/+ (Soft key) Allows the user to scroll through the channels / Psets and view the most recent result for all cell members (if any). Browse (Soft key) Allows the user to switch function for the lower right view in runtime (the available selections are depending on the Power Focus 3000 configuration). The default view is configured in Cset. Result Windows The Result will flash (blink) if the value is outside (selected parameters 2, 3 programmed limits. When a Pset is chosen but it has no and 4) tightenings, ‘------‘ will be displayed instead of value. Parameter Window Value outside programmed limits will blink the result. When a (selected parameter 1) Pset is chosen but it has no tightenings, ‘------‘ will be displayed instead of value. Result type The name of the selected parameter (Torque, Angle etc). Channel number The number of the monitored channel (tool). If the channel belongs to the current Power Focus the background is black. However, if the channel belongs to another Power Focus in the Cell the background will be grey. Pset / Multistage number The Pset identification number (belongs to a specific channel (Power Focus). A “P” before the number indicates a Pset. An “M” indicates a multistage. Pset / Multistage name The name of the monitored Pset / Multistage. Number of tightenings The number of completed tightenings in a batch. Batch size The number of tightenings programmed in the batch. If the batch is activated the background will be black. Otherwise it is grey. Result unit The unit for the selected parameter (engineering unit). (Nm, degree etc.) VIN Vehicle identification number. Will be displayed simultaneously with the tightening result.

37

Page 38

User Interfaces Result mode – Statistics The screenshot below shows the statistics of all saved tightenings of the monitored channel and Pset.

F E

D

A

A Type B Param C Stat alarm D Parameter names E Parameter values F Parameter units

38

B

C

(Soft key) Choose between All tightenings, Last subgroup and # of tightenings. (Soft key) Choose between available statistics – torque, angle. (Soft key) Shortcut to statistical events log Name of parameters. Measured / calculated results. Units in which the parameters are displayed

Page 39

User Interfaces The view below shows the statistics of the last n (here 30) saved tightenings of the monitored channel and Pset.

The view below shows the statistics of the last subgroup of the monitored channel and Pset. This view shows the subgroup Statistics of the monitored channel and Pset.

39

Page 40

User Interfaces Result mode – Stat Chart The statistical charts of group mean value and group range are used for statistical process control. When there are less then 10 group results, the remaining columns to the right will be empty when there is anything to show.

B

A

A Graphical presentation

B Name and value of calculated parameters

40

The last ten subgroups results (the most recent is on the right hand side). The results outside the programmed limits are flagged. An arrow indicates if the value is outside a limit (above the max limit line or below the min limit line).

Page 41

User Interfaces Result mode – Trace G

I

F E

H

A

A Type B Select C Offset D Hold

E Measured angle

F Peak torque G Status H Peak point

B

C

D

(Soft key) Choose between Tq / Time, Tq / Angle etc. (Soft key) Choose which trace to be displayed (8 selections, Last 3 OK and Last 4 NOK plus the Latest) (Soft key) Choose between Angle offset (view from Start final angle) or No offset (view from Cycle Start torque). (Soft key) If the window is in run- mode, the trace will be updated after each completed tightening. If it is in hold mode, it will not be updated. The angle at the same time as when the highest torque was measured. When the result is outside acceptance interval, the text flashes with a frequency of 1 Hz. The highest torque value during the tightening. When the result is outside acceptance interval, the text flashes. Mode (Hold/Run), Type and Select. The level where the torque is at maximum.

41

Page 42

User Interfaces Result mode – Job F

G

H

E

I

D

J

K

A

B

C

The header text is on a black background if the job is currently running, otherwise the header will be text on a grey background. The different Psets are black text on a white background if the Pset is not done, otherwise it will be white text on a black background. A B

Mode Select

C

Command

D E F G H I

Pset no Channel no Job reference Job no Job Name Batch size

J

Number of tightenings Job Status

K 42

(Soft key) Turn Job mode off / on. (Soft key) Select new Job. (If PF Keyboard is configured for Job select source in Cset.) (Soft key) Issue a command – Restart job, Decrement, Increment, Bypass or Abort job. (If PF Keyboard is configured for Job select source in Cset.) The Pset for this channel is programmed for the present Job. The channel number within the present Job. Channel number of the Job Master. The number of the current Job. The name of the current Job. The number of tightenings in a batch. If batch count is active the background is black. Otherwise it is grey. The number of completed tightenings. Displays the status of the current job.