Page 43

User Interfaces Result mode – (view) all

G H F

I

E

A

B

C

D

The header text (“Pset 1”) is white on a black background if the Pset is one currently running, otherwise it will be white text on a grey background. A B C D E

Arrow left Arrow up Arrow down Arrow right Arrow down

F Arrow up G Title of columns

H Most recent result I

Measured results

(Soft key) Scroll left in columns. (Soft key) Scroll up in rows. (Soft key) Scroll down in rows. (Soft key) Scroll right in columns. Arrow indicating that it is possible to scroll down to view earlier results. Arrow indicating that it is possible to scroll up to view later results. Date/Time; Trq; Angle; (Rundown Angle / PVT / Self-tap / Number in batch / Batch size / Tightening ID) (it is possible to scroll through these last six by using the right/left arrow keys). If a tightening is completed while this window is active, the result will be displayed here. Values outside programmed limits are presented in inverse mode. Those parameters which are not measured / stored will be displayed as ‘---‘.

43

Page 44

User Interfaces Result mode – Event Log

F

E

A

A B C D E F

44

Type Arrow up Arrow down More.. Arrow down Events

B

C

D

(Soft key) Choose between Statistical and General events. (Soft key) Move cursor one row up. (Soft key) Move cursor one row down. (Soft key) Information about the event. Indicates that it is possible to scroll down to view earlier events. List of event numbers and date / time.

Page 45

User Interfaces Programming mode – enter Programming Tree To enter programming mode, press the PROG key.

There are three ways to enter the different sets: 1. Press corresponding softkey. 2. Press the corresponding number key, i.e. 1 for Pset. 3. Move up/down in the tree and enter a branch using the right arrow key or enter. From a branch (a set) there are various ways to enter the correct parameter: 1. Explore the programming tree using the arrow keys. 2. Enter the parameter number. Example: If you have entered Job, the job-branch, and want to edit parameter J100, press 1 – 0 – 0. This will make the Power Focus 3000 show the existing Jobs.

45

Page 46

User Interfaces Programming mode – enter parameter values There are various different types of parameter value; Number, List value, String value and IP address. •

Number, with or without decimals. (Example: P110 – Pset Cycle start)

Above: Example of a number value – Parameter P110.

•

List value. When entering this type of parameter, a list of alternatives will pop up where a value can be shown by scrolling up / down using the arrow keys. (Example: P100 – Pset Control strategy)

Above: Example of a list – Parameter P100.

46

Page 47

User Interfaces •

String value. Enter a character in the parameter field by pressing the number keypad. Waiting three seconds or pressing arrow right key will result in the cursor moving to the position for the next character. It is also possible to move cursor back using the arrow left key. Pressing the Cl key while the cursor is located on a character will delete the character. (Example: P402 – Pset name)

Above: Example of a string value – Parameter 402.

•

IP address. Enter the four numbers between 0 and 255, separated by a dot. (Example: C300 – (own) IP address).

Above: Example of an IP – address value – Parameter C300.

47

Page 48

User Interfaces

3.3

ToolsTalk

ToolsTalk is an application that acts as an interface between the user and the Power Focus 3000. It is used for programming and monitoring Power Focus from a PC. With ToolsTalk installed, users can communicate with the Power Focus via the serial port (RS232) as well as over the Ethernet. Ethernet communication makes the management of Power Focus 3000 easy and efficient, since ToolsTalk can be installed on a PC anywhere on the network.

3.3.1

Scope

ToolsTalk is an application designed to serve as an interface between the user and Power Focus 3000. With ToolsTalk, users can create and edit instructions and settings for the Power Focus 3000. The settings needed to control the tightening process performed by the Power Focus include: Tightening strategies, Control parameters, Torque parameters, Angle parameters, Speed and Ramp parameters and Time parameters. The settings are transferred to Power Focus via an Ethernet connection or via the serial port. Process data can be collected from the Power Focus and monitored in real-time. ToolsTalk makes management of Power Focus easy and efficient, since the software can be installed on any PC on the network. ToolsTalk is fully compatible with Microsoft Windows® and supports widely accepted communication protocols such as: Ethernet, TCP/IP and RS232 (serial communication).

48

Page 49

User Interfaces

3.3.2

Getting started

Installation Setup ToolsTalk is easy to install. •

Insert the installation CD

•

Run setup.exe and follow the onscreen instructions

Registration To complete installation a ToolsTalk software registration have to be done. Registration can be done over the web, from the Atlas Copco Tools web site at: http://www.atlascopco.com/tools/software Enter your license number and you will be issued with a registration key. Start ToolsTalk from Windows Click on the START button, select Program and then Atlas Copco Tools and click on ToolsTalk Power Focus 3000. Alternatively, double-click on the ToolsTalk Power Focus 3000 shortcut on your desktop.

49

Page 50

User Interfaces

3.3.3

Overview

If you are familiar with Microsoft Windows, you will soon be comfortable with the ToolsTalk interface. The figure below shows the Menu row (1), the Selection panel (2), the Toolba r (3) and the PF Map (4): 1 2 3 4

Almost every function in ToolsTalk has its own window. There are several ways to start a function in ToolsTalk. For almost all functions you can use a menu item in the menu row, click on a tool button in the toolbar or double-click on text in the PF map. ToolsTalk is even designed to work without using a mouse. Therefore is it possible to access all functions from the menu row, even though a mouse will make things easier.

50

Page 51

User Interfaces Menu row This section describes the different functions found in the menu row. Note that an additional menu appears in the menu row when opening a function window. For example, if you open a Pset window, a new menu named “Pset” will appear in the menu row. When you open File, you can open and save files, print and exit ToolsTalk.

From the Edit menu you can create a new Pset, Multistage or Job

The Focus menu allows you to decide what kind of connection to use when connecting to the Power Focus. You can choose between an Ethernet connection or a serial connection. The offline mode allows you to work with ToolsTalk without being connected to a Power Focus.

51

Page 52

User Interfaces From the Options menu, you can select if you want the toolbar to be shown or not. The following functions are available: Settings, Change language, Get Event Log and View Com Messages and Forced release progcontrol.

The Window menu allows you to set, properties for windows and icons. This menu also enables you to open the activate menu.

The Activate menu contains a list of all available functions (Pset, Job, Multistage, etc).

From the Help menu, you can access the Power Focus Manual help file. About ToolsTalk PF brings up details about the version of the program you are using.

52