Page 53
User Interfaces Selection panel Symbol
Designation
Description
Selected Controller
The available options are: Serial connection, Ethernet connection or the Offline mode
Running Pset
If Pset select source (Config parameter C222) is in Ethernet/Serial mode, you can select running Pset/multistage from this combo box
Running Job
If Job select source (Config parameter C221) is in Ethernet/Serial mode, you can select running job from this combo box
PF List
To make an easier Ethernet connection to a Power Focus use the combo box PF List. Select an item in the combo box and ToolsTalk will connect to the corresponding Power Focus. The information in the list contains: name, IP address and Port number
53
Page 54
User Interfaces Toolbar Symbol
Designation
Description
Pset
This icon opens the Pset (Parameter set) programming window. Click on the arrow to the right and the programmed Psets are shown along with number and name. The list can contain a maximum of 250 Psets
Multistage
This icon opens the Multistage programming window. Click on the arrow to the right and the programmed Multistages will be displayed along with number and name
Job
This icon opens the programming window for Job
Configuration
This icon opens the configuration window
Synchronisation This icon opens the synchronisation programming window
54
Diagnostic
This icon opens the diagnostics window
Identifier
This icon opens the identifier window
FieldBus
This icon opens the FieldBus configuration window
Monitoring
Click on the arrow to the right of this icon to select an appropriate monitor: Result monitor, Job monitor or Operator monitor. Using a result monitor is a convenient way to monitor tightening status
Page 55
User Interfaces Trace
Click the Trace icon to bring up a graphical display of the tightening results
Statistics
Click on this icon to display statistical results and graphs.
Focus map
This icon opens the PF Map if it is closed.
Connect
The Connect icon changes appearance depending on the connection status. When the PC is not in contact with the Power Focus, the upper icon is visible. Clicking on the icon will establish contact between the PC and the Power Focus. Once a connection is established, the lower icon will appear. Clicking on the icon will disconnect the PC from the Power Focus.
55
Page 56
User Interfaces
3.3.4
PF Map
The PF Map gives an overview and shortcuts to all settings in ToolsTalk. Click on the minus or plus symbols for opening and closing menus and double click on function names (Pset, Multistage, Job, etc) for opening the corresponding function. Brief information about the selected setting is displayed in the right panel of the PF Map. Right click on the function names to create a new instance of the function. If you click the Hide details button, only the left panel of the PF Map will be shown.
56
Page 57
User Interfaces
3.3.5
Connecting To Power Focus 3000
You can select between the alternatives serial connection or Ethernet connection. Serial connection When using the serial connection, it is important to use the proper baud rate settings. In order to establish a connection between ToolsTalk and the Power Focus they must use the same baud rate. Default baud rate is set to 9600 bit/s. To change the baudrate on the ToolsTalk side, use Settings. And on the Power Focus side, use Config. Also make sure that the serial cable is connected to the correct Com port on the PC. The Com port settings can be set in Settings. Ethernet connection Under Settings you can edit the IP Address for the Power Focus to which you would like to establish a connection. You can also set whether that Power Focus is a Netmaster, Cellmaster or a Controller. If you connect to a Netmaster you will get a list of Cell Masters in the PF Map. Double-click on a Cellmaster to get a list of all Power Focus (Controllers) in the cell. If you connect to a Cellmaster you will get a list of all Power Focus (Controllers) in the cell. To connect to a controller, double-click on a Power Focus. To connect There are several ways to connect a Power Focus from ToolsTalk: • • • • •
Select Focus in Menu row and then choose between serial connection or Ethernet connection. Select Selected Controller in Selection row, click on Serial PF or Ethernet PF. In the PF Map, double -click on Serial PF or Ethernet PF. Use image in Toolbar. Default this button will make a serial connection. However, it remembers the most recent connection so if you have made an Ethernet connection previously, the next time you click this button it will make an Ethernet connection. Use predefined Power Focus unit from PF List (Options menu – Settings – PF List tab). Connect via image in Toolbar.
“Serial PF” and “Ethernet PF” will change to the Power Focus name once the connection is established.
57
Page 58
User Interfaces To disconnect If you want to disconnect, click on the Disconnect image in Toolbar or select Focus>Ethernet or Serial->”PF name”->Disconnect. Offline mode See Offline section.
3.3.6
Settings
In the Settings menu you can set the IP Address for the Power Focus to which you want to establish a connection. You can also state whether that Power Focus is a “Cell Master” or a “Net Master”. In the Settings menu you can also: 1. Setup serial communication with Power Focus 3000 2. Setup Ethernet communication with Power Focus 3000 3. Create settings for logging communication messages between ToolsTalk and Power Focus 3000 4. Select if ToolsTalk should display Power Focus 3000 Error and Warning messages 5. Select the torque unit for display in ToolsTalk (This selection will not affect unit display in Power Focus 3000. See config set-up to find out how to change unit) 6. View parameter number and explanations (hints) 7. Auto store connected Power Focus to file on disconnect 8. Auto connect to Power Focus upon ToolsTalk start-up. 9. Set up printout 10. Administrate PF list Open the Settings menu via Options in the main menu bar.
58
Page 59
User Interfaces The Settings dialog has four tab sheets: 1. Communication and connecting installation 2. Set-up for viewing information inside the ToolsTalk PF application 3. Printout set-up 4. PF List administration Click OK to store your set- up. Click Close if you do not want to make any changes. Click Help if you need help about Power Focus 3000. The Communication sheet has four sections. In the Communication set-up field you can select if you want to view controller errors and warnings. Under Serial set-up you can select which Com port to use [normally Com1 or Com2]. The baud rate can be set to 2400, 4800, 9600, 19200, 38400, 57600 or 155200. Note that all the connected Power Focus 3000 units need the same baud rate value to work together. Default value is 9600. Under Ethernet set-up, you can select the type of connected Power Focus (Netmaster, Cellmaster or Controller), set Port number and Controller IP address. The default port number value is 6543. If you use an item from PF List (PF available list) then all three parameters [type, port, IP] will be set simultaneously. In the LOG section, you can select if you want to log communication between Power Focus and ToolsTalk. If you set Log to On, then messages will be stored in a file. The file name is stated in the Log file field.
59
Page 60
User Interfaces Via the Advanced button you can make special set- up for logging. If Split Log is activated the size of log.txt file cannot exceed the value set in Log file size . When the file is full the program will copy the contents to a file called log~.txt and erase the content of log.txt. Afterwards data will continue to be stored in log.txt. From the Help menu, you can open a series of help files. About ToolsTalk PF shows details about the current program version. The Application tab sheet has three sections. The first section is about ToolsTalk Presentation for programming windows. Use this if you want to view hints and parameter numbers. It is also possible to select display units (Nm, lbf.ft, lbf.in or kpm).
The first checkbox in Automatic functionality activates/deactivates Auto collapse tree views. The figure on the right shows what is displayed with the Auto collapse tree views checkbox selected.
60
Page 61
User Interfaces The figure on the right shows what is displayed with the Auto collapse tree views checkbox deselected.
If Auto connect on start up is checked, ToolsTalk will try to connect to the Power Focus via serial communication immediately on start- up. If the Auto store PF to file on disconnect box is checked, ToolsTalk will store PF to file when disconnecting. The last field allows you to set the path for Default directory. Log files and auto stored PF files will be saved to the selected default directory. The Printout tab sheet contains details of printoutsettings. If you enter text in the Printout footer it will be appear on every printed paper. If you use the A4 Printout format, select A4 format, otherwise select Default format. Printout Colours is only applicable if you use a colour printer.
61
Page 62
User Interfaces From the PF List tab you can manage the PF available list. You can add, modify and remove items. An item is a Power Focus with Name, IP address, port type and controller type. If you want to use multiple PF list files you can select which one you want to use.
Using PF List in Main Menu: The PF List is an easier way to connect a controller. Just select an item in the combo box and ToolsTalk will try to connect to the selected Power Focus 3000. The PF list can also be used in Communication settings.
62