The text of a manual · part 8 of 33
Power Focus 3000: Control and Drive Unit for TENSOR-S Electric Nut Runners: User Interfaces, pages 63 to 72
Pages 63 to 72 of 315, from Power Focus 3000: Control and Drive Unit for TENSOR-S Electric Nut Runners
The original document is the PDF (7.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Atlas Copco PF3007-C-HW and Atlas Copco PF3007-G-HW
Page 63
User Interfaces
3.3.7
Programming
There are several tools available to the user to create various instructions for the Power Focus 3000. This page gives a brief introduction to them. Pset A Pset contains all the necessary information Power Focus 3000 needs to perform a tightening. There are a number of parameters included in a Pset, among them: Control parameters, Torque parameters, Angle parameters etc. For more detailed information about Pset see chapter 7, Parameter set (Pset). Multistage Under some conditions it is necessary to perform a tightening in several stages. These circumstances require specific tightening strategies. Multistage allows the user to create linear sequences of Psets to perform a tightening divided into stages. For more detailed information about multistage see chapter 8, Multistage. Job A Job is a collection of Psets, which is useful when performing multiple tightening operations in a row with different requirements. This is convenient since the operator do not have to select a new Pset for every tightening. For more detailed information about Job see chapter 9, Job. Config Config contains functions for configuration of general settings. This includes System settings, I/O settings, Communication settings and Protocol settings. For more detailed information about Config see chapter 10, Configuration (Config). Sync A number of Power Focus 3000 in the same logical cell can be synchronised to perform the same task simultaneously. This type of operation requires synchronisation of the Power Focuses involved. With this tool Synchronisation parameters can be created. For more detailed information about Sync see chapter 11, Synchronisation (Sync).
63
Page 64
User Interfaces Diagnostic The Diagnostic tool can be used for retrieving information from the Power Focus containing general tool- information, Service status, Hardware- and software-configuration. Some programming is also made using the Diagnostics function. For more detailed information about Diagnostic see chapter 12, Diagnostic. Identifier It is possible to send an identifier string to the Power Focus 3000. This string is normally generated from a barcode reader connected to one of the serial ports on the Power Focus 3000 (this barcode is in car plants usually called VIN or ESN). For more detailed information about Identifier (barcode reader) see chapter 13, Identifier. FieldBus A FieldBus communication can be used for data communication between the Power Focus 3000 and PLC’s. It is an effective and fast way for data transferring of short data packages. For more detailed information about FieldBus see chapter 14, FieldBus.
3.3.8
Monitoring
ToolsTalk provides a number of monitors designed to present extensive information about various functions of Power Focus. They are: Function Result monitor Job monitor
Description Displays tightening results and statistics Displays created Jobs and provides functionality for managing Jobs Operator monitor Displays in-depth tightening-result information, also containing graphic representation such as charts and status- indicators Picture monitor Displays a visual description of the tightening-process, suitable for training purposes Get All Results Displays result information stored in the Power Focus and export possibilities Trace Displays detailed chart information from the latest tightening
64
Page 65
User Interfaces Result monitor The Result monitor presents the latest tightening results, from the Power Focus 3000 and the used Pset. The Tightening result includes, among other things: Final Torque, Final Angle, Over all status, Torque chart and Angle chart. If you want to watch result from a unique Pset you can select between Tightening values, Torque chart, Angle chart or Torque/Angle plot. You can watch several windows with different views, with a max limit of four.
To open the Result Monitor: • Select Window in the main menu row and then click on Activate->Result->Result Monitor. • Use the PF map. First, double-click on Monitors and then on Result Monitor. • Use Monitor icon in Toolbar. First click on the icon and then on Result Monitor.
65
Page 66
User Interfaces Job monitor Job Monitor displays created Jobs and provides functionality for managing Jobs.
For a function description (Restart Job, Decrement, Increment, Bypass, Abort Job and Job off) see chapter 9, Job.
66
Page 67
User Interfaces Operator monitor Selecting Operator monitor will bring up the following window:
In the Operator monitor, detailed information about the tightening operation is presented. For details about the information shown in the Operator monitor see below. b c d e a f l g m j h k i
67
Page 68
User Interfaces Letter a b c d e f h i j
Parameter PFName Pset Vin Over all status Events Final Torque status Final Angle status Batch Batch order PlotChart k l m
TorqueChart Final Torque Final Angle g
Explanation The name of the PF control The parameter set used to perfo rm the tightening Vehicle Identification Number The overall-status of the tightening Warnings and errors (See below) Status- indicator for Final Torque (Yellow- Low/ Green-OK/Red-High) Status- indicator for Final Angle (Yellow- Low/ Green-OK/Red-High) The order of the current operation in the batch The Over all status for the respective operation in the batch Displays the final torque and final angle, relative to the acceptance window Displays torque as a function of time Final Torque Final Angle
When Right-clicking anywhere in the Operator monitor, the following menu is shown:
The menu contains options that can be used to customise the Operator monitor. Alternative Explanation Activate Presentation User preferences for the content of the Operator monitor Set Background Colour Possibility to set the background colour for the Operator monitor Toggle Window Toggles the window Toggle MouseCursor Toggles the Mouse-cursor Set Label Colour Possibility to set the label colour for the Operator monitor
68
Page 69
User Interfaces Activate Presentation When choosing Activate Presentation the window on the left is shown. By checking the boxes, the user can customise the information shown in the Operator monitor
69
Page 70
User Interfaces Events The Over all status is indicating if the operation was performed within the specified limits for Final Torque and Final Angle and whether any error occurred or not. In the case below the over all status was Not OK since the trigger was lost.
Picture monitor The Picture monitor is a feature that gives the user visual guidance throughout the Job sequence. The next tightening (Pset) in can be presented graphically with an image (e.g. a picture of the area where a bolt is placed). When selecting Operator Monitor the window to the left is shown. To open the Picture monitor, select Picture Monitor and click OK. To edit the presentation click Picture Setup.
70
Page 71
User Interfaces Choosing Picture monitor will bring up the following window:
It shows a window similar to the Operator monitor with information about the latest tightening to the left and a picture associated with the next tightening (Pset) in the Job, to the left. Note! Picture monitor is not adjusted for Pset with batch counter. Only one picture per Pset is allowed.
71
Page 72
User Interfaces Picture monitor set-up To set up Picture monitoring, choose Picture Monitor Setup. The user has the possibility to associate an image- file with a Pset. Select a Pset from the list. Click on Set picture and select an image- file using the file-selector window. To import saved settings for the Picture monitor click on Read from file. To save the settings click on Store to file. A Save As-window will appear and the user can choose where to store the file containing the settings. When finished click OK. Note! A certain picture can only be specified for a certain Pset, so in order to make the use of Picture monitor easier, each tightening should be individually specified when creating a Job, instead of using Batches as a batch is a sequence of identical Psets. The alternative would be to choose a picture containing the whole batch with Set picture .
72