Page 73
User Interfaces Get all results Power Focus can store up to 5000 individual tightening results. With the Get All Results option, the user is able to retrieve and view these. The user also has the choice of saving them to a textfile or an Excel- file. When the Get All Results option is chosen the window below appears.
Simply choose a specific Pset and click OK. The results from that Pset is then shown in the following window.
By choosing Save To File the results are saved into a text- file. The user can also choose to open and view the results in Microsoft Excel® by selecting Open In Excel. This, of course, requires a properly installed version of Excel. 73
Page 74
User Interfaces Trace
Select which type of chart you want to view. The choices available are: Torque over Time, Angle over Time, Speed over Time, Torque and Angle over Time, Torque over Angle or Torque and Speed over Time. Select if you wish to have Angle Offset and Auto update. Auto update will automatically update the charts as new tightening data arrive. If not selected the user can choose from viewing: Latest, Latest OK, Second latest OK, third latest OK, Latest NOK, Second latest NOK or third latest NOK tightening. NOK says Not OK. The Limits function allows you to customise the limits in the chart. The user can select from: Min Max, Self- tap, PVT, Rundown and CM. How to open Trace •
Select Window in Main Row and then click on Activate->Trace.
•
Use the PF map. Double-click on Trace.
•
Use Trace icon in Toolbar. Click on the icon.
74
Page 75
User Interfaces
3.3.9
Storing programming on file
To store the programmed settings on file, open the File menu. The following options are available: Read <object>, Read PF form File, Save <object> or Store PF to File. <Object> could be Pset, Multistage, Job, Config or Diagnostic, etc. Store PF to File
Read PF from File
Save <object> (Config, Pset, Job etc.) Read <object > (Config, Pset, Job etc.)
When you are connected to a Power Focus and perform Store PF to File, all programmed settings in the Power Focus will be stored to a file. The user will be asked to name the file. When you are connected to a Power Focus and perform Read PF from File. You will update the Power Focus with programmed settings stored on file. The user will be asked to name the file. This function stores a single object to file. The selected window in ToolsTalk will be store to file. The user will be asked to name the file. This function writes a single object file to the Power Focus. The selected window will be update with data from the file. The user will be asked to name the file.
When you store Power Focus to file, the user is asked to name the file. What actually happens is that ToolsTalk will store the programmed settings on a more than one file (for example one file for each Pset, Multistage and Job) A Pset will be stored in a file with extension “pfp”. File extension Explanation pf3 Overhead file pfp Pset pfc Config pfj Job pfm Multistage pfs Sync pff FieldBus pfd Diagnostic pfq Function pfi Identifier Excel When you store PF to File you have the option to store files in Excel format. Select Excel as file format in the Save As dialogue. The overhead file will have the extension xp3. Extensions for the other stored files will be “xls”. This file can be used in Microsoft Excel®.
75
Page 76
User Interfaces
3.3.10 Offline Offline mode gives the user the opportunity to conduct programming and configuration without being connected to a Power Focus unit. All programming will be stored to or read from a file. This file can be copied to one or more Power Focus units. There are three different ways to select the Offline mode: Select the menu Focus -> Offline
Select Offline from the ‘Selected Controller’ – box
Double click on the Offline icon in the ‘PF Map’ window.
The file can be located on the local hard drive, network, etc. There are a number of default files supplied when installing ToolsTalk. You can also find these files separately on the ToolsTalk installation CD-ROM. Depending on the licence level (Gold, Silver or Bronze) of the Power Focus the corresponding file shall be selected. You can recognise the different license le vels by the names of the default files: Gold.pf3, Silver.pf3 and Bronze.pf3. A good idea is to make a backup of these files.
76
Page 77
User Interfaces A file can be created by first connecting (Serial or Ethernet) to a Power Focus and then clicking on the menu File -> Store PF to File. Name the file and store it in an appropriate location.
Select a file with the same license level as the Power Focus unit. ToolsTalk opens the selected file and the user is able to change it. If a file with higher license level is selected you can still continue to change its contents, but if you try to use the file with a Power Focus unit with lower license level a warning message will be displayed. For example, the warning message to the right will be displayed if you try to use a file containing a larger number of Psets and Jobs than the Power Focus will accept. Click Yes if you want to use the file and accept the limitations. In this case the maximum number of Psets and Jobs will be set by the Power Focus.
77
Page 78
User Interfaces Configuring an offline tool To be able to set proper values for torque, speed etc in offline mode select first the tool that will be used for the application. •
Open the Diagnostic window and click on the Set Tool button.
When the Set tool window is opened, the tool list is shown and the following functions are available: a) Tool name b) Max torque c) Max RPM d) Tool ratio e) New tool a b c f g h d f) Delete tool g) Edit tool h) Confirm programming, OK i) Cancel j) Help e
78 i j
Page 79
User Interfaces It is possible to configure a new tool if the specific tool is not found. •
Click on the New Tool button to configure a new tool.
•
Fill in the following tool data: - Tool name - Tool max torque - Tool ratio - Tool max rpm
•
Click on OK to confirm the selections.
79
Page 80
User Interfaces
3.3.11 Tip The first letter of an item If you are placed in a Combo box or tree view you can type the first letter of an item to get focus on that item directly. Open Pset 1 programming window (The same procedure opens a all types of windows; Config, Job, Multistage etc.) 4. Select the menu item Window -> Activate -> Pset -> 1 Ctrl+Alt+P
5. Select Pset icon in toolbar. Click on the arrow at the right side. This brings up a list with available Psets. Click on the Pset you want to open.
6. Double click on the Pset 1 in the ‘PF Map’ window. If the Pset tree view is closed, double click on the Pset first.
80
Page 81
Cells and Networking
4
Cells and Networking
The new Power Focus 3000 software offers extended networking facilities. In Power Focus 3000 a network is created by using Ethernet TCP/IP, which is a standard in network communication. In the Silver and Gold Power Focus ve rsions, Ethernet is a built- in standard feature. No extra network cards are required. ToolsNet is a web-based utility that collects all data sent out by the Power Focus. It is based on the TCP/IP Ethernet standard. Each network only requires one ToolsNet installation. Netscape or Internet Explorer is used as browser interface. Ethernet TCP/IP networking also makes it simple to program and overview all Power Focuses in the network from a PC with the ToolsTalk software installed. All is built- in as standard functionality. To learn more about ToolsNet and ToolsTalk contact your local Atlas Copco representative. All units equipped with the Silver or the Gold software versions can be arranged in Cells and Nets. Cells and Nets offer a way of logically arranging and planing a factory network. Since Cells allow Compact Power Focus models to be programmed from Graph Power Focus models, it can also reduce the costs of a factory installation. Once a cell has been set- up, the Gold software enables synchronised groups and Cell Jobs to be run. In a factory, Power Focus units can be grouped in Cells. A Cell can be constituted of up to 20 Power Focus units. Cells can then be grouped into Nets. Every cell has a unique Cell Network ID and every Power Focus unit within a Cell has its own unique Channel ID. With a Power Focus 3000 Graph model it is possible to browse through the different channels and program or view the result from other Power Focus units in the cell. An ToolsTalk-equipped PC may also program all Power Focus 3000 units. A Cell Member still functions as a separate unit and reports directly to ToolsNet. To avoid conflicts with other traffic in an existing network, we recommend to build a separate Power Focus network and connect the two with a router or a PC with router functionality. Cells should be hooked up to the Power Focus network via switches. An example of a factory network with Cells and a Net is shown in the figure on the next page.
81
Page 82
Cells and Networking
Example of a factory network configuration. A Net is made up of three Cells. Each Cell has four Cell Members.