Page 83
Cells and Networking
4.1
General networking set-up
To create a network you first have to give each unit an individual IP number. This can be done in two ways. Either via a PC equipped with ToolsTalk using RS232 (serial communication) or, on the Graph Power Focus model, through the user interface of the unit. The IP number gives every Power Focus an identity and an address, which enables separation and individual communication with every unit. It is important that each unit has a unique IP address. Not having unique IP addresses may cause serious network problems. Power Focus uses fixed IP addresses. It is important to plan your network configuration with reference to IP addresses assigned to each Power Focus. Contact your network administrator to know which IP addresses to use. Every Power Focus uses multicast to send a message used by other devices to verify its presence on the network. The frequency of that message can be specified and it affects how fast a drop out is detected. It also affects the network load. Contact your network administrator before changing the default setting of six seconds. The Subnet mask is used for partitioning a TCP/IP network. The Default router is used as gateway in communication with other networks. Contact Yo ur network administrator to get a valid Subnet mask and Default router address. Default router must be on the same Subnet as the IP address.
4.1.1
Networking set-up using Power Focus 3000 Graph
Networking set- up using the interface on a Power Focus 3000 Graph. Note! The Power Focus 3000 has to be restarted for the network settings to take effect. 2 Config – 3 Communication – 0 Remote Com
• • • • •
Set the IP address of the connected Power Focus to a unique number within the network. Set the Subnet mask according to network partitioning. Default router is optional. Press Store to save settings in the RBU. Restart the Power Focus 3000.
83
Page 84
Cells and Networking 2 Config – 3 Communication – 1 Advanced
•
Cell keep alive is the time interval for multicasting keep alive messages on the network.
4.1.2
Networking set-up using ToolsTalk
Networking set- up using a ToolsTalk equipped PC connected to the Power Focus 3000 via RS232, serial communication. Note! The Power Focus 3000 has to be restarted for the networking settings to take effect. OPTIONS – SETTINGS •
Set the Com port on which the Power Focus is connected.
•
Connect the Power Focus by clicking on the connect button.
84
Page 85
Cells and Networking CONFIG – COMMUNICATION •
• • • • •
Set the IP address of the connected Power Focus to a unique number within the network. Set the Subnet mask according to network partitioning. Default router is optional. Cell Timeout is the time interval for broadcasting alive messages on the network. Click Store to save settings. Restart the Power Focus 3000.
85
Page 86
Cells and Networking
4.2
Cell and Net
The Cell and Net concept is part of the Silver and the Gold software versions. It enables you to logically arrange your network. The Gold software also enables synchronised groups and Cell Jobs to be run. With the Cell concept you can arrange the Power Focus units at an assembly station in a Cell. The Net concept enables you to group all Cells on the assembly line.
The figure shows a Cell that is created by using three Compact units, one Graph unit and a hub.
A Cell consists of one Cell Master and a maximum of 19 Cell Members, a total of 20 units. Cells can then be grouped into Nets, the maximum number of Cells in a net is 1000. Each net has a Net Master. One Power Focus unit can function both as Cell Master and Net Master. Every cell has a Cell ID unique on the network. Within a Cell every Power Focus unit has its own and unique Channel-ID. With the Power Focus Graph you can browse through the different channels and program or view the result from any other Power Focus unit in the Cell. The Cell Master is not different from the Cell Members when it comes to functionality. Any Power Focus Graph Cell Member can be used to program any other member of the cell, even the Cell Master. All Power Focus units may also be programmed by a PC equipped with ToolsTalk, the Power Focus software. A Power Focus Graph always displays one channel. By default it displays its own Channel- ID. A Cell Member still functions as a separate unit. Every Cell Member has its own tool. The LEDs on the tool, the Power Focus unit and on possib le external devices such as alarms etc, reflect only the results from the unit itself. When programming a remote Power Focus unit, make sure it is not in use by anyone else. Otherwise it might lead to damages on the tool or a joint. It might also lead to personnel injuries.
86
Page 87
Cells and Networking
4.2.1
Cell and Net set-up using Power Focus 3000 Graph
This section gives an example on how to set up a Cell Master using a Power Focus 3000 Graph. Note! The Power Focus 3000 has to be restarted for the cell/net settings to take effect. 2 Config – 1 System setup – 0 Password & name
• • • • •
Set Channel ID to a number unique within the cell [1-20]. PF name is optional. [max 25 characters] Set Cell ID number to a number unique within the network [1-1000]. Cell name is optional. [max 25 characters] Press Store to save settings in the RBU.
2 Config – 3 Communication – 0 Remote Com
• • • •
• •
IP address, Subnet mask and Default router. Set Netmaster IP address to the IP address of the Net Master. Set Cellmaster IP address to the IP address of the Cell Master. Define a Cell Master or Net Master by setting Cellmaster IP address / Netmaster IP address equal IP address. Press Store to save the settings. Restart the Power Focus 3000.
87
Page 88
Cells and Networking
4.2.2
Cell and Net set-up using ToolsTalk
This section gives an example on how to set up a Cell Master using ToolsTalk: Note! Power Focus has to be restarted for the cell/net settings to take effect.
CONFIG –PASSWORD AND NAME • Set Channel ID to a number unique within the cell [1-20]. • PF name is optional. [max 25 characters] • Set Cell ID to a number unique within the network [1-1000]. • Cell name is optional. [max 25 characters] • Click Store to save the settings. CONFIG – COMMUNICATION • IP address, Subnet mask and Default router. • Set Netmaster IP address to the IP address of the Net Master. • Set Cellmaster IP address to the IP address of the Cell Master. • Define a Cell Master or Net Master by setting Cellmaster IP address / Netmaster IP address equal IP address. • Cell Timeout • Click Store to save the settings. • Restart the Power Focus 3000.
88
Page 89
Cells and Networking
4.3
Connecting ToolsTalk
When connecting to a Controller, Cell Master or Net Master make sure that the following settings are correct. OPTIONS – SETTINGS • Set Controller IP address of the Power Focus that you want to connect. • Under Ethernet set-up, check whether the connected Power Focus is a Controller, Cell Master or a Net Master.
•
To connect the Power Focus Controller, Cell Master or Net Master, click on the connect button.
PF MAP • When a Cell Master or Net Master is connected, clicking on the correspond ing line in the PF Map will expand the Cell tree/ Net tree. The figure to the right shows an example of a PF Map that displays a Net Master with five Cell Masters connected.
89
Page 90
Page 91
Rapid Backup Unit (RBU)
5
Rapid Backup Unit (RBU)
The RBU, Rapid Backup Unit, is a software key and data storage unit for the Power Focus 3000 controller. The RBU unlocks software/functions available for each version of the Power Focus 3000. It also stores a backup copy of the Power Focus 3000 configuration. The RBU backup copy makes it possible to move functionality and configurations between different Power Focus 3000 controllers. There are three different RBU versions, Bronze , Silver and Gold, where the Gold RBU unlocks the full capacity and functionality of the Power Focus 3000. The table on the next page displays the functionality available for each RBU version. The RBU serial number also is also a part of the Power Focus 3000 Ethernet MAC address. Power Focus 3000 Ethernet address: 00-50-D6 -XX-YY-ZZ (from serial RBU). Example RBU with serial number C00015767: 00015767 => 003D97 (Hexadecimal) C00015767 => 00-50-D6-00-3D-97 (MAC address) RBU Bronze The Bronze RBU unlocks the basic Power Focus 3000 tightening functionality. Note that it is not possible to run the Power Focus 3000 Graph with a Bronze RBU. RBU Silver The Silver RBU unlocks advanced Power Focus 3000 functionality such as Multistage and Job. The Silver RBU also enables full networking capability and the possibility to run Tensor DS tools. RBU Gold The Gold RBU unlocks the full capacity and functionality of the Power Focus 3000. Features such as Cell jobs and Synchronised tightenings are only available with the Power Focus 3000 Gold version. The table on the next page shows the RBU functionality overview.
91
Page 92
92
Gold
Hardware Power Focus 3000 Compact Power Focus 3000 Graph Power Focus 3000 Color Capacity Number of Psets Number of Jobs Number of tightening results Control strategies Tq con Tq con / Ang mon Ang con / Tq mon Tq con / Ang con (AND) Tq con / Ang con (OR) DS-con Rev Ang con Click Wrench RotateSpindleForward RotateSpindleReverse Control options PVT mon PVT compensate PVT selftap Rundown angle mon Current monitoring CW/CCW operation Functionality Multistage Step synchronisation Job Cell job I/O TCP/IP Programming Port (RS232) I/O Expansion (up to 124 in/124 out) Optional Fieldbus Card Barcode reader port (RS232) IR Networking Cell Net Syncgroup Toolsnet Factory Overview Other Tensor DS Tools Quick programming Auto set Real time statistics SPC Barcode reading
Silver
Bronze
Rapid Backup Unit (RBU)
x x x x x x x
64 0 5000
250 99 5000