Page 93

Rapid Backup Unit (RBU)

5.1

Connecting the RBU

Make sure that the power is switched off when connecting and disconnecting the RBU. Connect (if not already connected) the RBU to the 15-pin connector on the back panel of the Power Focus 3000 (see figure below).

5.2

Start-up instructions

At start-up, the Power Focus 3000 checks for inconsistencies between the controller and RBU configurations. If an inconsistency is detected the user is prompted to select either the controller or RBU configuration. This makes it possible to move/copy configurations between Power Focus 3000 controllers by using the RBU. The table on the next page describes the selections available and how to choose configuration. If the Power Focus 3000 and the RBU are incompatible for other reasons than a configuration mismatch (e.g. they have an older software version), either the Power Focus 3000 or the RBU is referred to as NOK. When changing RBU type there is only possible to load the configuration from the RBU. Press the plus (+) or minus (-) button on the Power Focus 3000 Compact to toggle between the selections. Confirm selection with the Enter button. Press the corresponding soft button to make a selection on the Power Focus 3000 Graph.

93

Page 94

Rapid Backup Unit (RBU) Status

Message at start up

Action

Compact

Graph

Power Focus and RBU matche s

No message

No message

---

Power Focus and RBU don’t match

Clear / RBU / PF

Select PF, Clear (All) or RBU

Select if you want to use the Power Focus’ or the RBU’s configuration.

Power Focus OK RBU NOK

PF / Clear / Stop

Select PF, Clear (All) or Stop

Power Focus NOK RBU OK

RBU / Clear / Stop

Select RBU, Clear (All) or Stop

Power Focus NOK RBU NOK

Clear / Stop

Select Clear (All) or Stop

Select if you want to use the Power Focus’ configuration. Otherwise select “Stop”. Select if you want to use the RBU’s configuration. Otherwise select “Stop”. Select “Clear” if you want to clear the Power Focus’ and the RBU’s memories. Otherwise select Stop.

IMPORTANT CHANGING RBU WILL CLEAR THE TIGHTENING RESULT DATABASE. Pushing the "Stop" button will only prevent the result database from being erased if the RBU has been changed between silver and gold, provided the previous RBU is re-inserted. Note that a change between gold/silver and bronze will clear the result database even if the "Stop" button is pressed. If the Power Focus 3000 is turned on with no RBU or a Power Focus 3000 Graph is turned on with a Bronze RBU the tightening result database will be cleared without a query to the user.

94

Page 95

Control and monitoring

6

Control and monitoring

6.1

Important

Tool tightening basics and safety issues There are different variables that control the tool rotation direction. They are: tool direction ring, tool tightening direction (parameter P240, see Parameter List) and tightening strategies. Tightening : Tightening a screw or a nut according to the selected control strategy. Loosening : Back off the screw or nut. This is done with full power. Loosening speed and ramp can be programmed. Reverse: Control strategy that loose the screw or nut a programmed number of degrees. The direction is always the opposite of the Tightening direction.

Direction Ring

6.1.1

Tool Trigger

Tool trigger start

With some exceptions the position of the tool direction ring at the time the tool trigger is pressed will give the direction of rotation. If the ring is in the right position the tool will rotate clockwise (CW) and counter clockwise (CCW) if the ring is in the left position. The direction will not change if the direction ring is moved while the tool is running. With parameter P240, Tool tightening direction, the tightening direction of the tool is selected. This means that the tool will tighten the joint clockwise (right-hand threaded joints) if CW is selected and the direction ring is in the right position. Select CCW for counter clockwise tightenings.

95

Page 96

Control and monitoring Note! If different tightening directions are used on the same tool, there is a risk that the operator will use the wrong direction for a specific screw. This could lead to unexpected reaction forces in the tool that could be dangerous for the operator. If Reverse angle or Rotate spindle reverse is used as tightening strategy, the “active” direction is the opposite from the Tightening direction (P240). For example, if CW is selected turn the direction ring to the left position. For safety reasons, it is not possible to loosen the joint when these strategies are selected.

6.1.2

Remote start (4-pin connector)

The remote start input is connected in parallel with the tool trigger and has the same functionality. If remote start input is used the tool trigger is disabled. The 4-pin connector must be wired correctly.

6.1.3

Tool start from digital input

If a digital input is used as start signal input, the direction ring and trigger on the tool are bypassed. If tool start from digital input is selected and activated, the tool will start tightening in the direction programmed in parameter P240, Tightening direction. The 4-pin connector must be wired correctly. Note! Do not use Tool Start From Digital Input via an I/O-expander on a synchronised tool group. Use only the four internal digital inputs.

6.1.4

Tool start from FieldBus

The FieldBus tool start input works in the same way as the tool start from digital input. The 4-pin connector must be wired correctly.

96

Page 97

Control and monitoring

6.2

Control Strategies

Power Focus 3000 offers several strategies for control and monitoring of the tool. This section gives a generic description of the control strategies available. Appendix A describes in detail how each control strategy works in combination with the tightening strategies. These control strategies are available in the Power Focus 3000: • • • • • • •

Torque Control (Tq con) Torque Control / Angle Monitoring (Tq con / Ang mon) Torque Control / Angle Control (Tq con / Ang con [AND]/[OR]) Angle Control / Torque Monitoring (Ang con / Tq mon) Reverse Angle (Reverse Ang) Rotate spindle forward/reverse (Rotate spindle forward/reverse) Click wrench (Click wrench)

For the Torque control tightening strategies the tightening process starts when the torque reaches Cycle start and ends when torque drops below Cycle complete for a period of End time milliseconds. For the Angle control and Reverse angle tightening strategies, the tightening process also starts when the torque reaches Cycle start. For the Rotate spindle tightening strategies, the tightening process starts immediately as the tool starts running. For these tightening strategies the tightening process ends when End time milliseconds has elapsed since Target angle was reached. The torque result presented is, with one exception, the peak torque measured during the tightening process. The exception is Reverse angle tightenings where the torque at peak angle is presented. The joint angle is defined by P121, Measure angle to. The joint angle can be measured from Start final angle to either Torque peak, Angle peak or Cycle complete. Note! P124, Final angle max is always evaluated from Start final angle to angle peak.

97

Page 98

Control and monitoring

6.2.1

Tq con

The Torque control strategy controls the torque. This strategy is selectable for both a one- or twostage tightenings. The tool stops when the torque reaches the Final target value. If, for some reason, the tool should exceed Final tq max, the tool shuts off and the (NOK) tightening results are shown.

6.2.2

Tq con / Ang mon

The Torque control and Angle monitor strategy controls the torque and monitors the angle. This strategy is selectable for both a one- or two-stage tightenings. The tool stops when the torque reaches the Final target value. If the tool for some reason should exceed Final tq max or Final angle max, the tool shuts off and the (NOK) tightening results is shown.

6.2.3

Tq con / Ang con [AND] / [OR]

The Torque control and Angle control strategy controls both torque and angle. This strategy is selectable for both a one- or two-stage tightenings. [AND] Power Focus 3000 controls the Final target value and the Final angle value. The tool stops when both targets are reached. They do not have to be reached at the same time. [OR] Power Focus 3000 controls the Final target value and the Final angle value. The tool stops when the first of these two targets are reached. For both [AND] and [OR], both the torque and the angle result must be within respective min and max limit. If, for some reason, the tool should exceed Final tq max or Final angle max , the tool shuts off and the (NOK) tightening results are shown.

6.2.4

Ang con / Tq mon

The Angle control and Torque monitoring strategy controls the angle and monitors the torque. This strategy is selectable for both a one- or two-stage tightenings. Target angle is then defined as the number of degrees between Start final angle and the peak angle. The tool stops at Target angle. If the tool for some reason should exceed Final tq max or Final angle max, the tool shuts off and the (NOK) tightening results is shown.

98

Page 99

Control and monitoring

6.2.5

Reverse Ang

The Reverse angle strategy reverses the spindle a specified number of degrees in the opposite Tool tightening direction. This is useful when, for example, the bolt needs to be loosened before the final tightening. Create a Multistage to combine and perform several Psets as one. Target angle is defined as the number of degrees between Start final angle and the peak angle. The tool stops at Target angle. If the tool for some reason should exceed Final torque max or Final angle max, the tool shuts off and the (NOK) tightening results is shown. Note! The torque value shown in the result is torque at peak angle. Note! Tightening fail if the torque never reaches Cycle start.

6.2.6

Rotate spindle forward/ reverse

The Rotate spindle forward/reverse strategies rotate the spindle a specified number of degrees, either forward or reverse, independently of torque. The only torque values monitored are Final tq max and Final tq min. Target angle is defined as the number of degrees between start of tightening and the peak angle. The tool stops at Target angle. If, for some reason, the tool should exceed Max final torque or Max final angle, the tool shuts off and the (NOK) tightening results are shown. Note! Tightening process begins when the trigger is pressed.

6.2.7

Click wrench

Select this strategy if the Power Focus 3000 shall indicate a click wrench or to incorporate other non-tightening operations into the work process such as ocular inspections or filling of fluid containers etc. It is possible to configure four independent click wrench operations, Click wrench number 1 – 4. A click wrenc h Pset only consists of a Click wrench number, Final Target torque and a Tool idle time. Each Click wrench number shall be associated with one digital input [see Appendix C; Digital Inputs And Outputs]. Asserting the specified Digital Input indicates to the Power Focus 3000 that the specified click wrench operation has been performed. Use Final Target to set the torque result level for click wrench tools. Use Tool idle time to avoid unintentional Digital Input assertion repetitions. Note! Resulting torque is the Final torque set by the Pset.

99

Page 100

Control and monitoring

6.3

Tightening Strategies

In order to achieve the best quality, speed and ergonomic behaviour the Power Focus 3000 supports a number of different tightening strategies. Both standard and proprietary patented strategies are supported. This section provides a generic description of the tightening strategies available. Appendix A contains a detailed description of how each tightening strategy works in combination with the control strategies.

6.3.1

One-Stage

Torque Final Target

Cycle start

1

Soft start

Cycle complete

Time Zoom step

Step 1 speed

Tool speed

Tightening is performed in one stage until Final Target torque has been reached. The tool accelerates fast to final speed. In this example, the Zoom step function is activated, which reduces tool speed when torque is close to Final Target. This means improved accuracy and reduced risk of overshoot.

100

Page 101

Control and monitoring

6.3.2

Two Stage

Torque Final Target First target

Cycle start

Cycle complete

Soft start Step 2 ramp

Step 1 ramp

Zoom step

Time

Step 2 speed

Step 1 speed

Tool speed

For a two stage tightening, the tool operates at high speed during the first stage and at lower speed during the second stage. The tool stops for about 50 ms between stages to reduce joint relaxation and then accelerates for the second stage.

101

Page 102

Control and monitoring

6.3.3

Quick Step

Torque Final Target First target

Cycle complete

Cycle start

Soft start

Time Zoom step

Step 1 ramp Step 1 speed

Step 2 speed Step 2 ramp

Tool speed

Quickstep is a two stage tightening with high tool speed during the first stage and a lower tool speed during the second stage. The speed changes immediately to second stage speed and does not stop between the stages. In this example the strategy ends with a Zoom step, which reduces the risk of overshoot.

102