Page 103
Control and monitoring
6.3.4
Ergoramp
Torque
Final Target Ergoramp First target
Cycle complete
Cycle start
Soft start
Zoom step
Time
Step 2 ramp Step 1 ramp
Soft joint
Step 2 speed
Step 1 speed
Tool speed Torque Final Target Ergoramp First target
Cycle start
Soft start
Step 1 ramp
Cycle complete
Step 2 ramp Step 2 speed
2
Zoom step
Time
Hard Joint Step 1 speed
Tool speed
Ergoramp is a two stage tightening with a constant increase of torque during the second stage. It is set automatically using the programmed Ergoramp value and the hardness of the joint. This strategy has the ergonomic advantage of giving the user the same feeling for both soft and hard joints when using the same Pset. 103
Page 104
Control and monitoring
6.4
Control options
6.4.1
Rundown angle
The Rundown angle option allows the angle at Rundown Complete to be monitored. If Rundown angel From start is selected, the rundown phase will start as the tool trigger is pressed. If Rundown angle From cycle start is selected, the rundown phase will start as torque exceeds Cycle start. The acceptance window for Rundown angle is set by Rundown angle min and Rundown angle max.
6.4.2
Zoom Step
The Zoom step option reduces tool speed when torque approaches Final target. Tool speed is reduced gradually down towards the Zoom step speed. Zoom step speed can be set to between 2% – 20% of maximum speed. Zoom step produces very accurate results, low scatter and quick tightenings.
6.4.3
Combined Zoom step and Ergoramp
By combining Zoom step and Ergoramp, the advantages of both strategies will be achieved. Tightenings are precise and, at the same time, ergonomically correct for the operator. Zoom step and Ergoramp strategies can be combined for most types of bolted joints.
6.4.4
PF2000 compatible
This parameter changes the characteristic of the PF3000 so that it becomes similar to that of the PF2000. Acceleration during ramping becomes slower. Programming of parameters is not otherwise affected.
104
Page 105
Control and monitoring
6.5
Programming +
6.5.1
Current Monitoring
The spindle torque is proportional to the motor current. By measuring motor current a method of measurement that is independent of the torque transducer is achieved. The torque forming current is expressed as percentage of nominal current at tool max torque. With Current monitoring selected it is possible to set an acceptance window for the torque.
6.5.2
PVT options
Some joints have a torque peak at the start of the tightening. The Power Focus 3000 can monitor such tightenings to make sure they get the expected torque characteristic curve. It also makes it possible to do tightenings where the start torque is higher then Final target or even Final tq max. One example is self-tap joints, but it might also be used for other types of joints. Three options are available PVT Self tap, PVT Monitoring and PVT Compensate. They might all be used separately or together. All three options runs during the rundown stage i.e. prior of Rundown complete.
6.5.3
PVT self tap
When the joint has a torque peak at the start of the tightening it can be recommended to use the PVT Self tap monitoring option to ensure that the tightening gets the right characteristics. It also makes it possible to do tightenings where the start torque is higher then Final target or Final tq max. The self tap interval starts at Cycle start. During the self tap interval the torque has to reach at leased the Self tap min level but must stay below the Self tap max limit. Self tap max is monitored in real-time during the self tap interval. The Self tap min value is evaluated against the self tap interval peak value at the end of the interval. To reduce the effect of noise (ringing) the PVT Self tap monitor mean values calculated from a number of windows. A highe r Number of monitor windows make the monitoring more sensitive whereas a lower number will filter more noise.
105
Page 106
Control and monitoring
6.5.4
PVT Monitoring
When the joint torque has to pass through an acceptance window prior to Rundown complete to pass as a correct tightening it is recommended to use the PVT Monitoring option. With PVT monitoring selected it is possible to set an acceptance window for the torque before Rundown complete. PVT max is monitored in real-time during the monitor interval and if exceeded, the tool will stop immediately. The PVT min value is evaluated against the monitor interval peak value at the end of the interval. To reduce the effect of noise (ringing) the PVT Self tap monitor mean values calculated from a number of windows. A higher Number of monitor windows make the monitoring more sensitive whereas a lower number will filter more noise.
106
Page 107
Control and monitoring
6.5.5
PVT Compensate
The Power Focus 3000 lets the torque levels be dependent of the prevailing torque during the rundown phase. That makes the torque levels change dynamically for each new tightening. The different torque values, e.g. First target and Final target, are compensated for the prevailing torque during the rundown phase. The compensation value is calculated at Rundown complete as an average torque from an interval preceding the PVT Compensate point. The tightening result is presented with the compensation torque subtracted. Warning! Final tq max is also compensated with the PVT Compensate value.
Torque P214 Self-tap max Acceptance window
P213 Self-tap min P231 PVT Comp point
P116 Rundown complete
P225 PVT Max limit Acceptance window P110 Cycle start P224 PVT Min limit
P211 Self-tap interval
P11x Torque P110 Cycle start P116 Rundown complete
P221 PVT Delay interval
P222 PVT Monitor interval
P21x PVT self-tap P210 PVT self-tap P211 Self-tap interval
P22x PVT monitoring P220 PVT Monitoring P221 PVT Delay interval
P212 no of self-tap windows P213 Self-tap min P214 Self-tap max
P222 PVT Monitoring interval P223 no. of PVT windows P224 PVT Min limit P225 PVT Max limit
Angle
P23x PVT compensate P230 PVT Compensate P231 PVT Comp point
107
Page 108
Control and monitoring
6.5.6
Options
Tool tightening direction Select Tool tightening direction. CW for right hand threaded screws and CCW for left hand threaded screws. To start in the correct direction you must turn the tool direction ring to its correct position. This parameter has no effect when running an Open End tool (Tube Nut tool). Soft stop If Yes the Power Focus 3000 will ramp down the torque when target is reached. It is recommended to always use Soft stop. Alarm on rehit If the Alarm on Rehit checkbox is marked the Power Focus 3000 will detect re- hits (event code E112). The red lights on the tool will be lit when a re-hit is detected. The criteria for re-hit are a short or a non-existing second stage in combination with a low speed in the first stage. Alarm on Tq < target Decides if the tightening shall be approved if the torque is lower than the Final target. This alarm option overrides the Final tq min limit, giving an alarm even if torque is within the min and max limit. Alarm on lost trigger Decides if the tightening shall be approved if the tool trigger is lost before target is reached. If used, a Not OK status will be issued even if the result is within acceptance windows. DS tuning factor The DS tuning factor is used to adjust the torque readings on Tensor tools running in DS control mode. Used to fine-tune the tool to specific joints. For more information on how to use DS torque tuning factor see section DS tools (DS control).
108
Page 109
Parameter Set (Pset)
7
Parameter Set (Pset)
Click on the Pset icon in ToolsTalk to view the Pset window. Push the PROG button on a Power Focus 3000 Graph keyboard to enter the Pset menu section. The set of parameters that controls the tightening process is contained within a so-called Parameter set (Pset). This section describes how to set- up the basic Pset parameters necessary to perform a tightening. Create a Pset by using Auto Set, Quick programming or by setting the parameter values manually using the Power Focus 3000 Graph or ToolsTalk. The basic Pset parameters: - Control parameters - Torque parameters - Angle parameters - Speed and Ramp parameters - Time parameters - Batch count parameters - Statistical parameters The Parameter list, chapter 18 contains a description of each parameter. Note! To be able to select Psets from ToolsTalk you have to set the parameter C222, Pset select source parameter to Ethernet/Serial (Config – I/O set-up - Other I/Os - Pset select source).
109
Page 110
Parameter Set (Pset)
7.1
Create a Pset using Graph
Navigate through the menus with the arrow buttons on the front panel and confirm selections with the Enter button. •
Press the PROG button.
The programming window appears.
•
110
Select Pset – Programming - Control.
Page 111
Parameter Set (Pset) •
In the Control window select: - Control Strategy - Tightening Strategy - Rundown angle - Zoom step - PF 2000 compatible
•
Save settings by pressing the Store button.
•
Go back one level and select Torque .
•
Set the Torque parameters.
•
Press Store or OK to proceed.
•
Go back one level and select Angle.
•
Set the Angle parameters.
•
Press Store or OK to proceed.
•
Continue the programming by setting Speed and Ramp, Time and Batch Count parameters in the same manner.
•
Press Store to save the Pset.
111
Page 112
Parameter Set (Pset) Pset admin • Select Pset - Pset setup - Pset admin.
In Pset administration you will be presented with five options – view existing Psets, create new, name, copy and delete Psets.
When you create a new Pset, choose a number in a list and name the Pset. To name Pset, open the Name Pset window and use number buttons to enter text. First three pushes produce small letters, e.g. a, b, c. The next three pushes will produce capital letters, A, B, C. The next push produces the number of the button. Use the Cl button to delete characters. For copying Psets, use soft buttons From and To and arrow buttons up and down for selecting Psets. •
112
Press Store to save your selections.