Page 21
Getting Started
11
In This Chapter. . . ., Introduction, DL405 System Components, Programming Methods, DirectLOGIC™ Part Numbering System, Quick Start for PLC Checkout and Programming, Steps to Designing a Successful System, Frequently Asked Questions
Page 22
1--2
Getting Started
Getting Started
Introduction The Purpose of this Manual
Thank you for purchasing our DL405 family of products. This manual shows you how to install, program, and maintain the equipment. It also helps you understand how to interface them to other devices in a control system. This manual contains important information for personnel who will install DL405 PLCs and components, and for the PLC programmer. If you understand PLC systems our manuals will provide all the information you need to get and keep your system up and running.
Where to Begin
If you already understand PLCs please read Chapter 2, “Installation, Wiring, and Specifications”, and proceed on to other chapters as needed. Be sure to keep this manual handy for reference when you have questions. If you are a new DL405 customer, we suggest you read this manual completely so you can understand the wide variety of features in the DL405 family of products. We believe you will be pleasantly surprised with how much you can accomplish with our products.
Supplemental Manuals
If you have purchased operator interfaces or DirectSOFT™, you will need to supplement this manual with the manuals that are written for these products.
Technical Support
We realize that even though we strive to be the best, we may have arranged our information in such a way you cannot find what you are looking for. First, check these resources for help in locating the information: S S S
Table of Contents -- chapter and section listing of contents, in the front of this manual Appendices -- reference material for key topics, near the end of this manual Index -- alphabetical listing of key words, at the end of this manual
You can also check our online resources for the latest product support information: S Internet -- Our Web address is http://www.automationdirect.com If you still need assistance, please call us at 770--844--4200. Our technical support group is glad to work with you in answering your questions. They are available Monday through Friday from 9:00 A.M. to 6:00 P.M. Eastern Standard Time. If you have a comment or question about any of our products, services, or manuals, please fill out and return the ‘Suggestions’ card that was shipped with this manual.
DL405 User Manual, 4th Edition
Page 23
Getting Started
1--3
Conventions Used
When you see the “notepad” icon in the left--hand margin, the paragraph to its immediate right will be a special note. The word NOTE: in boldface will mark the beginning of the text.
When you see the “exclamation mark” icon in the left--hand margin, the paragraph to its immediate right will be a warning. This information could prevent injury, loss of property, or even death (in extreme cases). The word WARNING: and text will be in boldface. Key Topics for Each Chapter
The beginning of each chapter will list the key topics that can be found in that chapter.
1
DL405 User Manual, 4th Edition
Getting Started
When you see the “light bulb” icon in the left--hand margin, the paragraph to its immediate right will give you a special tip. The word TIP: in boldface will mark the beginning of the text.
Page 24
1--4
Getting Started
Getting Started
DL405 System Components
CPUs
The DL405 product family is one of the most versatile and widely accepted PLCs used for medium control applications. The CPUs are small, yet powerful. Their modular design and expansion capability blend well with todays fast-moving industry. The following is a summary of the major DL405 system components. There are three feature-enhanced CPUs in this product line, the DL430, DL440, and the DL450. All include a built-in power supply and communication ports. Each CPU offers a large amount of program memory, a substantial instruction set and advanced diagnostics. The DL450 features drum timers, floating-point math, built-in PID loops, and additional communications ports. Details of these CPU features are covered in Chapter 3, CPU Specifications and Operation.
Bases
Three base sizes are available in the system: 4 slot, 6 slot and 8 slot.
I/O Configuration
The DL430/440 CPUs can support up to 640 I/O between the CPU base and expansion bases (the DL450 up to 1024 local I/O). A maximum of 512 additional I/O for the DL430, 1024 for the DL440, or 1536 for the DL450 can be added to the system in the form of remote I/O bases and slice I/O blocks. Each of these I/O configurations is explained in Chapter 4, System Design and configuration.
I/O Modules
The DL405 family has some of the most powerful modules in the industry. They include a complete range of discrete modules which support 24 VDC, 125 VDC, 110/220 VAC and up to 10A relay outputs. Analog modules provide 12-bit resolution and several selections of input and output signal ranges (including bipolar). Specialty modules include a 100KHz high-speed input, thermocouple, general purpose communication, magnetic pulse input, 16 loop PID function and more.
Programming Methods
DirectSOFT Programming for Windows™
Handheld Programmer
There are two programming methods available to the DL405 CPUs, RLL (Relay Ladder Logic) and RLL PLUS.Stage Programing. Both the DirectSOFT programming package and the handheld programmer support RLL and Stage. The DL405 CPUs can be programmed with one of the most advanced programming packages in the industry ----DirectSOFT 5, Ver. 5 or later. DirectSOFT 5 is a Windows-based software package that supports many of the Windows features you already know, such as cut-and-paste between applications, point-and-click editing, viewing and editing multiple application programs at the same time, browsers, and newly added Intelligent Box (IBox) Instructions which will help ease your programming tasks. DirectSOFT 5 universally supports the DirectLOGIC™ CPU families. This means you can use the same DirectSOFT 5 package to program DL105, DL205, DL305, DL405 or any new CPUs that we add to our product line. There is a separate manual for the DirectSOFT 5 programming software. All DL405 CPUs have a built-in programming port for use with the handheld programmer (D4--HPP). The HPP can be used to create, modify and debug your application program. A separate manual for the DL405 HPP is available.
DL405 User Manual, 4th Edition
Page 25
Getting Started
The diagram below shows the major components and configurations of the DL405 system. The next two pages show specific components for building your system.
COMPUTERS and OPERATOR INTERFACE
PEER-TO-PEER and MASTER/SLAVE COMMUNICATIONS
Printer
305
System Migration or Expansion
DirectNET/Modbusr Communication (max. 3300ft/1000m)
DirectNET/Modbusr Communication (max. 3300ft/1000m) 1. ONLINE/OFFLINE Programming 2. Reporting 3. Monitoring 4. Debugging
405
General RS232C/ RS422 Port (max. 3300ft1000m)
DirectNET Communication (max. 3300ft/1000m)
Local Operator Interface or handheld programmer 405
RM
Connects to DL405 Programming Port
DCM MB DCM MSTR
EX
(Max. 3.3ft/1m)
EX Up to 3 expansion bases total (only 2 shown)
RS
REMOTE I/O
RS
1. Flexible Placement of I/O 2. Reduced Installation Costs 3. Versatile I/O Offering
DL405 User Manual, 4th Edition
Getting Started
DL405 System Diagrams
1--5
Page 26
Getting Started
1--6
Getting Started
Direct LOGIC™ DC INPUT 8pt 24--48 VDC 16pt 12--24 VDC 16pt 12--24 VDC (1ms response) 32pt 24 VDC 32pt 5--12 VDC 64pt 24VDC
AC INPUT 8pt 110--200 VAC 16pt 110 VAC
AC/DC INPUT 8pt 90--150 VAC/DC Isolated 16pt 12--24 VAC/DC
PROGRAMMING Handheld Programmer with Built-in RLL PLUS DirectSOFT 5 Programming for Windows
COPROCESSORt MODULES RS232C / RS422 / RS485 Telephone Modem Program Memory Ranges from 128K to 512K
SPECIALTY MODULES 8/16pt Input Simulator 8pt Interrupt Input Module High Speed Counter Module 8 pt. Magnetic Pulse Input Module 16 Loop PID Module 4 Loop Temperature Controller SDSt Interface Module Filler Module
DL405 User Manual, 4th Edition
CPUs DL430 -- 110/220 VAC P/S, 6.5K Built-in EPROM Memory DL440 -- 110/220 VAC P/S, 22.5K Memory (Memory Cartridge Required) DL440 -- 24 VDC or 125 VDC P/S, 22.5K Memory (Memory Cartridge Required) DL450 -- 110/220 VAC P/S 7.5K Built-in Flash Memory DL450 -- 24 VDC or 125 VDC P/S 7.5K Built-in Flash Memory
BASES
4 Slot Bases (expandable or nonexpandable) 6 Slot Bases (expandable or nonexpandable) 8 Slot Base (expandable or nonexpandable)
MEMORY CARTRIDGES CMOS RAM w/battery UVPROM EEPROM
Page 27
Getting Started
RELAY OUTPUT DC OUTPUT 8pt 8pt 16pt 16pt 32pt 32pt 64pt
12--24 VDC 24--250 VDC 5--24 VDC 12--24 VDC 5--24 VDC 12--24 VDC 5--24VDC
8pt 8pt 8pt 16pt
AC OUTPUT 8pt 18--220 VAC 16pt 18--220 VAC
10A/pt 5A/pt 2A/pt 1A/pt
I/O SYSTEMS Expansion Bases Local Base Expansion Unit 110/220 VAC P/S Local Base Expansion Unit 24 VDC P/S Local Base Expansion Unit 125 VDC P/S Remote I/O Remote I/O Master Module Remote I/O Slave Unit 110--220 VAC Remote I/O Slave Unit 24 VDC DL450 CPU Direct remote I/O link on Port 3
NETWORKING Ethernet Communication Module Data Communication Module DirectNET Network/Modbusr DL450 CPU (Ports 1 and 3) DirectNET Network/Modbusr Modbusr Master Module Modbusr Slave Module TIWAYt Network Interface Module Shared Data Network Module
ANALOG 4CH 8CH 16CH 4CH 8CH 16CH 8CH 8CH
Input Input Input Output Output Output Thermocouple Input RTD Input
DL405 User Manual, 4th Edition
Getting Started
DL405 Family
1--7
Page 28
1--8
Getting Started
Getting Started
DirectLOGIC™ Part Numbering System A DL405 PLC control system may be comprised of many products from the DL405 family. The part numbering system below shows how the part numbering systems work for each product category. Part numbers for accessory items such as cables, batteries, memory cartridges etc. are typically an abbreviation of the description for the item.
CPUs and Micro PLCs Specialty CPUs Product family
D1/F1 D2/F2
D4--
440DC
--1
D3--
05B
DC
D4--
16
N
D
2
D3--
16
N
D
2
D3/F3 D4/F4 Class of CPU / Abbreviation
230...,330...,430...
Denotes a differentiation between similar modules
--1, --2, --3, --4
Bases Product family
D2/F2 D3/F3 D4/F4
Number of slots
##B
Type of Base
DC or empty
Discrete I/O DL205 Product family
D2/F2
DL305 Product family
D3/F3
DL405 Product family
D4/F4
Number of points
04/08/12/16/32/64
Input
N
Output
T
Combination
C
AC
A
DC
D
Either
E
Relay Current Sinking
R 1
Current Sourcing
2
Current Sinking/Sourcing
3
High Current
H
Isolation
S
Fast I/O Denotes a differentiation between Similar modules
F --1, --2, --3, --4
DL405 User Manual, 4th Edition
F --1