Chapter 5: Standard RLL Instructions - Comparative Boolean
Comparative Boolean
1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D
Store If Equal (STRE) DS5 Implied HPP
Used
The Store If Equal instruction begins a new rung or additional branch in a rung with a normally open comparative contact. The contact will be on when Vaaa equals Bbbb .
V aaa
B bbb
V aaa
B bbb
Store If Not Equal (STRNE) DS5 Implied HPP
5–26
Used
The Store If Not Equal instruction begins a new rung or additional branch in a rung with a normally closed comparative contact. The contact will be on when Vaaa does not equal Bbbb. Operand Data Type
DL06 Range
....................................B V-memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V Pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P Constant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . K aaa bbb
See memory map See memory map ––
See memory map See memory map 0–9999
In the following example, when the BCD value in V-memory location V2000 = 4933, Y3 will energize. DirectSOFT 5
Handheld Programmer Keystrokes
DirectSOFT32 V2000
K4933
Y3
$ STR
OUT
SHFT
E
E
J 4
GX OUT
C 4 D 9
D 3
A 2
D 3
3
A 0
A 0
0
ENT
ENT
In the following example, when the value in V-memory location V2000 =/ 5060, Y3 will energize. DirectSOFT 5 DirectSOFT32 V2000
K5060
Handheld Programmer Keystrokes Y3
SP STRN
OUT
SHFT
E
F
A 5
GX OUT
DL06 Micro PLC User Manual, 3rd Edition Rev. A
C 4 G 0
D 3
A 2
A 6
ENT
0
A 0
ENT
A 0
0
Page 181
Chapter 5: Standard RLL Instructions - Comparative Boolean
Or If Equal (ORE) DS5 Implied HPP
Used
The Or If Equal instruction connects a normally open comparative contact in parallel with another contact. The contact will be on when Vaaa = Bbbb.
V aaa
B bbb
V aaa
B bbb
Or If Not Equal (ORNE) DS5 Implied HPP
Used
The Or If Not Equal instruction connects a normally closed comparative contact in parallel with another contact. The contact will be on when Vaaa does not equal Bbbb. Operand Data Type
DL06 Range
....................................B V-memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V Pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P Constant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . K aaa bbb
See memory map See memory map ––
See memory map See memory map 0–9999
In the following example, when the BCD value in V-memory location V2000 = 4500 or V2002 =/ 2500, Y3 will energize. DirectSOFT 5 DirectSOFT32 V2000
K4500
Handheld Programmer Keystrokes Y3 OUT
$
SHFT
E
F
A
STR E 4
V2002
5
Q
K2500
SHFT
C
D
E
A 0
C
A 2
F 4
A 0
0
A 0
C 2
0
ENT
5
D
A 0
ENT
4
3
2 GX OUT
A 2
0 E
OR
C 4
ENT
3
In the following example, when the BCD value in V-memory location V2000 = 3916 or V2002 050, Y3 will energize. DirectSOFT 5 DirectSOFT32 V2000
K3916
Handheld Programmer Keystrokes Y3 OUT
V2002
K2500
$ STR D
SHFT
E
J
B
3
9
R ORN
SHFT
E
C
F
A
2 GX OUT
C 4 G 1
6
0 D 3
0
0
A
A 2
A
A
A 0
0
ENT C
4
5
A 2
0
C 0
ENT
ENT
DL06 Micro PLC User Manual, 3rd Edition Rev. A
2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D 5–27
Page 182
Chapter 5: Standard RLL Instructions - Comparative Boolean
And If Equal (ANDE)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D
DS5 Implied HPP
Used
The And If Equal instruction connects a normally open comparative contact in series with another contact. The contact will be on when Vaaa = Bbbb.
V aaa
B bbb
V aaa
B bbb
And If Not Equal (ANDNE) DS5 Implied HPP
5–28
Used
The And If Not Equal instruction connects a normally closed comparative contact in series with another contact. The contact will be on when Vaaa does not equal Bbbb
Operand Data Type
DL06 Range
....................................B V-memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V Pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P Constant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . K aaa bbb
See memory map See memory map ––
See memory map See memory map 0–9999
In the following example, when the BCD value in V-memory location V2000 = 5000 and V2002 = 2345, Y3 will energize. DirectSOFT 5 DirectSOFT32 V2000
K5000
Handheld Programmer Keystrokes V2002
K2345
Y3 OUT
$ STR F
SHFT
E
A
A
5
0
V AND
SHFT
E
C
D
E
2
A 0
C
3
5
A 0
A
A 2
4 D
0
0
ENT
4 F
A
A 2
0
3
GX OUT
C 4
0
C 0
2
ENT
ENT
In the following example, when the BCD value in V-memory location V2000 = 5000 and V2002 =/ 2345, Y3 will energize. DirectSOFT 5 Handheld Programmer Keystrokes
DirectSOFT32 V2000
K5000
V2002
K2345
Y3 OUT
$ STR F
SHFT
E
A
A
5
0 SHFT
E
C
D
E
2
0
4 D 3
5 ENT
A 0
A
A 2
F
0
0
ENT C
4
3
DL06 Micro PLC User Manual, 3rd Edition Rev. A
A
A
A 2
0
V AND
GX OUT
C 4
ENT
0
C 0
2
Page 183
Chapter 5: Standard RLL Instructions - Comparative Boolean
Store (STR) DS5 Implied HPP
Used
The Comparative Store instruction begins a new rung or additional branch in a rung with a normally open comparative contact. The contact will be on when Aaaa is equal to or greater than Bbbb.
Store Not (STRN) The Comparative Store Not instruction begins a new rung or DS5 Implied additional branch in a rung with a normally closed comparative HPP Used contact. The contact will be on when Aaaa < Bbbb. Operand Data Type
A aaa
B bbb
A aaa
B bbb
DL06 Range
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A/B V-memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V Pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p Constant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . K Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TA Counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CTA aaa bbb
See memory map See memory map –– 0–377 0–177
See memory map See memory map 0–9999
In the following example, when the BCD value in V-memory location V2000 욷 1000, Y3 will energize. DirectSOFT 5 DirectSOFT32 V2000
K1000
Handheld Programmer Keystrokes Y3
$ STR
OUT
B
SHFT
V AND
C
A
A
A
1 GX OUT
0 D 3
A 2
0
0
A 0
A 0
0
ENT
ENT
In the following example, when the value in V-memory location V2000 < 4050, Y3 will energize. DirectSOFT 5
Handheld Programmer Keystrokes
DirectSOFT32 V2000
K4050
Y3
SP STRN
OUT
E
SHFT
V AND
C
A
F
A
4 GX OUT
0 D 3
5
A 2 0
A 0
ENT
ENT
DL06 Micro PLC User Manual, 3rd Edition Rev. A
A 0
0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D
5–29
Page 184
Chapter 5: Standard RLL Instructions - Comparative Boolean
Or (OR)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D
DS5 Implied HPP
Used
The Comparative Or instruction connects a normally open comparative contact in parallel with another contact. The contact will be on when Aaaa is equal to or greater than Bbbb.
A aaa
B bbb
A aaa
B bbb
Or Not (ORN) DS5 Implied HPP
5–30
Used
The Comparative Or Not instruction connects a normally closed comparative contact in parallel with another contact. The contact will be on when Aaaa < Bbbb. Operand Data Type
DL06 Range
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A/B V-memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V Pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p Constant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . K Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TA Counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CTA aaa bbb
See memory map See memory map –– 0–377 0–177
See memory map See memory map 0–9999
In the following example, when theBCD value in V-memory location V2000 = 6045 or V2002 욷 2345, Y3 will energize. DirectSOFT 5
Handheld Programmer Keystrokes
DirectSOFT32 V2000
K6045
Y3 OUT
$ STR G
SHFT
E
A
E
6 V2002
0
Q
K2345
OR D
C 2
A 2
F 5
SHFT
V AND
C
E
F
ENT
4 D 3
5
A 0
A 0
0
ENT
4
3
GX OUT
C 4
A
A 2
0
C 0
2
ENT
In the following example when the BCD value in V-memory location V2000 = 1000 or V2002 < 2500, Y3 will energize. DirectSOFT 5
Handheld Programmer Keystrokes
DirectSOFT32
$ V2000
K1000
Y3
STR
OUT
B
SHFT
E
A
A
1 V2002
K2500
0
R ORN C
F 2
DL06 Micro PLC User Manual, 3rd Edition Rev. A
A 2
A 0
SHFT
V AND
C
A
A
ENT
0 D 3
0 ENT
A 0
A 0
0
ENT
0
5
GX OUT
C 4
A
A 2
0
C 0
2
Page 185
Chapter 5: Standard RLL Instructions - Comparative Boolean
And (AND) DS5 Implied HPP
Used
The Comparative And instruction connects a normally open comparative contact in series with another contact. The contact will be on when Aaaa is equal to or greater than Bbbb.
And Not (ANDN) The Comparative And Not instruction connects a normally DS5 Implied closed comparative contact in series with another contact. HPP Used The contact will be on when Aaaa < Bbbb. Operand Data Type
A aaa
B bbb
A aaa
B bbb
DL06 Range
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A/B V-memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V Pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p Constant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . K Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TA Counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CTA aaa bbb
See memory map See memory map –– 0–377 0–177
See memory map See memory map 0–9999
In the following example, when the value in BCD V-memory location V2000 = 5000, and V2002 욷 2345, Y3 will energize. DirectSOFT 5
Handheld Programmer Keystrokes
DirectSOFT32 V2000
K5000
V2002
K2345
Y3
$ STR
OUT
F
SHFT
E
A
A
5
0
V AND C
D 2
C 4 A 0
SHFT
V AND
C
E
F
ENT
4
0
A
A 2
5
D
A
A 0
0
ENT
0
3
GX OUT
A 2
0
C 0
2
ENT
3
In the following example, when the value in V-memory location V2000 = 7000 and V2002 < 2500, Y3 will energize. DirectSOFT 5
DirectSOFT32 V2000
K7000
Handheld Programmer Keystrokes V2002
K2500
Y3 OUT
$ STR H
SHFT
E
A
A
7
0
W ANDN C
F 2
GX OUT
5
C 4
A 2
A 0
SHFT
V AND
C
A
A
ENT
0
0 Y AND
0
0
ENT
0
SHFT
A
A 0
A
A 2
D 3
0
C 0
ENT
DL06 Micro PLC User Manual, 3rd Edition Rev. A
2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D
5–31
Page 186
Chapter 5: Standard RLL Instructions - Immediate Instructions
Immediate Instructions
1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D
Store Immediate (STRI) DS5 Implied HPP
Used
The Store Immediate instruction begins a new rung or additional branch in a rung. The status of the contact will be the same as the status of the associated input point at the time the instruction is executed. The image register is not updated.
X aaa
Store Not Immediate (STRNI) DS5 Implied HPP
Used
The Store Not Immediate instruction begins a new rung or additional branch in a rung. The status of the contact will be opposite the status of the associated input point at the time the instruction is executed. The image register is not updated.
X aaa
Operand Data Type
DL06 Range aaa
Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . X
0–777
In the following example when X1 is on, Y2 will energize. DirectSOFT32 5 DirectSOFT X1
Handheld Programmer Keystrokes $
Y2
STR
I
SHFT
B 8
1
ENT
OUT GX OUT
C 2
ENT
In the following example when X1 is off, Y2 will energize. DirectSOFT 5 DirectSOFT32 X1
Handheld Programmer Keystrokes Y2 OUT
SP STRN
SHFT
GX OUT
I
B 8
C 2
1 ENT
Or Immediate (ORI) DS5 Implied HPP
Used
The Or Immediate connects two contacts in parallel. The status of the contact will be the same as the status of the associated input point at the time the instruction is executed. The image register is not updated.
X aaa
Or Not Immediate (ORNI) DS5 Implied HPP
5–32
Used
The Or Not Immediate connects two contacts in parallel. The status of the contact will be opposite the status of the associated input point at the time the instruction is executed. The image register is not updated.
DL06 Micro PLC User Manual, 3rd Edition Rev. A
X aaa
ENT
Page 187
Chapter 5: Standard RLL Instructions - Immediate Instructions
Operand Data Type
DL06 Range aaa
Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . X
0–777
In the following example, when X1 or X2 is on, Y5 will energize. DirectSOFT 5 DirectSOFT32
Handheld Programmer Keystrokes Y5
X1
$
B STR
OUT
SHFT
OR
X2
ENT
1
Q GX OUT
C
I 8
2
F
ENT
ENT
5
In the following example, when X1 is on or X2 is off, Y5 will energize. Handheld Programmer Keystrokes
DirectSOFT32 DirectSOFT 5 Y5
X1
B
$ STR
OUT
R ORN
X2
ENT
1 SHFT
C
I 8
2
F
GX OUT
ENT
ENT
5
And Immediate (ANDI) DS5 Implied HPP
Used
The And Immediate connects two contacts in series. The status of the contact will be the same as the status of the associated input point at the time the instruction is executed. The image register is not updated.
X aaa
And Not Immediate (ANDNI) DS5 Implied HPP
Used
The And Not Immediate connects two contacts in series. The status of the contact will be opposite the status of the associated input point at the time the instruction is executed. The image register is not updated.
X aaa
Operand Data Type
DL06 Range aaa
Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . X
0–777
In the following example, when X1 and X2 are on, Y5 will energize. DirectSOFT 5
DirectSOFT32 X1
Handheld Programmer Keystrokes X2
Y5
B
$
OUT
STR V AND
ENT
1 SHFT
GX OUT
I
C 8
ENT
2
F
ENT
5
In the following example, when X1 is on and X2 is off, Y5 will energize. DirectSOFT 5
DirectSOFT32 X1
Handheld Programmer Keystrokes X2
Y5 OUT
$
B 1
STR W ANDN GX OUT
SHFT
ENT
I
C 8
F 5
2
ENT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D
ENT
DL06 Micro PLC User Manual, 3rd Edition Rev. A
5–33
Page 188
Chapter 5: Standard RLL Instructions - Immediate Instructions
Out Immediate (OUTI)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D
DS5
Used
HPP
Used
The Out Immediate instruction reflects the status of the rung (on/off ) and outputs the discrete (on/off ) status to the specified module output point and the image register at the time the instruction is executed. If multiple Out Immediate instructions referencing the same discrete point are used it is possible for the module output status to change multiple times in a CPU scan. See Or Out Immediate.
Y aaa OUTI
Or Out Immediate (OROUTI) DS5
Used
HPP
Used
The Or Out Immediate instruction has been designed to use more than 1 rung of discrete logic to control a single output. Multiple Or Out Immediate instructions referencing the same output coil may be used, since all contacts controlling the output are ored together. If the status of any rung is on at the time the instruction is executed, the output will also be on.
Y aaa OROUTI
Operand Data Type
DL06 Range aaa
Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Y
0–777
In the following example, when X1 is on, output point Y2 on the output module will turn on. For instruction entry on the Handheld Programmer, you can use the instruction number (#350) as shown, or type each letter of the command. DirectSOFT 5 DirectSOFT32
Handheld Programmer Keystrokes Y2
X1
$
B STR
OUTI
O INST#
D
F 3
C 2
A 5
0
ENT
ENT
ENT
In the following example, when X1 or X4 is on, Y2 will energize. DirectSOFT DirectSOFT32 5 X1
Handheld Programmer Keystrokes Y2 OR OUTI
X4
$
B
O INST#
D
F 3
C
Y2 OR OUTI
1
STR
2 $
A
4 D
F 3
C
DL06 Micro PLC User Manual, 3rd Edition Rev. A
0
ENT
ENT
ENT
ENT
ENT E
O INST#
ENT
5
STR
2
5–34
ENT
1
ENT A
5 ENT
0
Page 189
Chapter 5: Standard RLL Instructions - Immediate Instructions
Out Immediate Formatted (OUTIF) DS5
Used
HPP
Used
The Out Immediate Formatted instruction outputs a 1–32 bit binary value from the accumulator to specified output points at the time the instruction is executed. Accumulator bits that are not used by the instruction are set to zero.
Y aaa OUTIF K bbb
Operand Data Type
DL06 Range aaa
Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Y Constant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . K
0-777 1-32
In the following example when C0 is on,the binary pattern for X10 –X17 is loaded into the accumulator using the Load Immediate Formatted instruction. The binary pattern in the accumulator is written to Y30–Y37 using the Out Immediate Formatted instruction. This technique is useful to quickly copy an input pattern to outputs (without waiting for the CPU scan). DirectSOFT 5 C0
LDIF
X10 K8
Load the value of 8 consecutive locations into the accumulator, starting with X10.
Constant
X17 X16 X15 X14 X13 X12 X11 X10
K8
ON OFF ON ON OFF ON OFF ON
Unused accumulator bits are set to zero
Acc.
OUTIF
Location X10
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
8
7 6 5
4 3
2
1
0
0
0
1 0
1
1 0
1
0
0
0 0
0
0
0
0 0
0
0
0
0 0
0
0
0
0
0 0
0
0
1
0
Y30 K8
Copy the value in the lower 8 bits of the accumulator to Y30-Y37
Location
Constant
Y37 Y36 Y35 Y34 Y33 Y32 Y31 Y30
Y30
K8
ON OFF ON ON OFF ON OFF ON
Handheld Programmer Keystrokes $ STR
NEXT
NEXT
NEXT
I
F
SHFT
L ANDST
D
GX OUT
SHFT
I
3
8 F
8
NEXT
0 B
5 A 3
ENT I
A 1
D 5
A
0
8 I
0
8
ENT
ENT
DL06 Micro PLC User Manual, 3rd Edition Rev. A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D
5–35