For the AutomationDirect Direct Logic DL06

Page 180

Chapter 10: LCD Display Panel

Confirm PLC Type, Firmware Revision Level, Memory Usage, Etc.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D

Menu 1, M1:PLC INFO.

10–6

From the default screen, press the MENU key one time to arrive at the PLC INFO menu option.

Default screen D L 0 6

P L C

Step 1.1 Press ENT to enter this menu selection. The first screen inside the PLC INFO selection is M1:PLC TYPE. This selection displays the model number of the PLC.

MENU

ENT

M E N U S C R E E N > M 1 : P L C I N F O .

Step 1.2

ESC

M 1 : P L C

T Y P E D 0 - 0 6 D D 1

Step 1.3 Press MENU again to sequence to PLC MODE. The PLC mode is either RUN, STOP (for Stop or Program Mode), TEST-STOP (for Test Stop Mode), or TEST-RUN (for Test Run Mode). You can put the DL06 in the Test Run Mode from the Test Stop Mode.

ESC

M a y 0 8 1 4 : 1 2 : 0 1

ESC

M 1 : P L C

MENU

MENU

ENT

ENT

MO D E R U N

ESC

MENU

ENT

NOTE: The menu screen examples shown in this section assume the password/lock feature is not turned on. If the password/lock feature is turned on, the user will be prompted by a message on the Display Panel to enter the password at the appropriate time. Users without password authorization will have access to a limited number of screens.

DL06 Micro PLC User Manual, 3rd Edition Rev. A

Page 181

Chapter 10: LCD Display Panel

Step 1.4 Press MENU again to sequence to FIRMWARE REV.

M 1 : F I R MWA R E R E V . V 1 . 0 0 0

Step 1.5 Press MENU again to sequence to LADDER MEMORY USED. The number of words used and the total number available in the PLC are displayed.

Press MENU again to sequence to LADDER PASSWORD, ACTIVATED OR NOT ACTIVATED. This is the last screen of the PLC INFO menu and is self-explanatory.

ENT

ESC

MENU

M E MO R Y / 7 6 8 0

ENT

M 1 : L A D D E R P A S SWD N O T A C T I V A T E D

Return to Step 1.1

Press ESC once more to return to the default screen.

MENU

M 1 : L A D D E R U S E D 2 1

Step 1.6

Press ESC to exit the M1 menu and return to the main menu.

ESC

ESC

MENU

ENT

M E N U S C R E E N > M 1 : P L C I N F O .

Default screen

ESC

D L 0 6

P L C

MENU

ENT

M a y 0 8 1 4 : 2 2 : 1 1

DL06 Micro PLC User Manual, 3rd Edition Rev. A

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D

10–7

Page 182

Chapter 10: LCD Display Panel

Examining Option Slot Contents

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D

Menu 2, M2:SYSTEM CFG.

10–8

From the default screen, press MENU twice to arrive at the M2:SYSTEM CFG. (System Configuration) menu option.

Step 2.1 > M 1 : P L C I N F O . > M 2 : S Y S T E M C F G .

Step 2.2 Press ENT to enter the SYSTEM CFG. menu selection.

ESC

MENU

ENT

M 2 : O P T I O N S L O T D 0 - D E V N E T S

1

NOTE: This is an example only and may not represent the contents of this or any option slot on your system.

Step 2.3 Pressing the MENU key four times will cycle through the four option slots. The model number of the option card in each slot is shown on line 2 or there is an indication that the slot is empty.

ESC

MENU

ENT

M 2 : O P T I O N S L O T 2 E M P T Y I / O S L O T

Step 2.4

ESC

MENU

ENT

M 2 : O P T I O N S L O T F 0 - 0 4 A D - 1

ESC

DL06 Micro PLC User Manual, 3rd Edition Rev. A

MENU

ENT

3

Page 183

Chapter 10: LCD Display Panel

Step 2.5 Press the ESC key twice to return to the default screen.

M 2 : O P T I O N S L O T 4 E M P T Y I / O S L O T

Return to Step 2.1

ESC

MENU

ENT

> M 1 : P L C I N F O . > M 2 : S Y S T E M C F G .

Return to default screen D L 0 6

ESC

MENU

P L C

ENT

M a y 0 8 1 4 : 5 7 : 2 1

DL06 Micro PLC User Manual, 3rd Edition Rev. A

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D

10–9

Page 184

Chapter 10: LCD Display Panel

Monitoring and Changing Data Values

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D

Menu 3, M3:MONITOR From the default screen, press MENU three times to arrive at the M3:MONITOR menu option.

Step 3.1

The M3:MONITOR sub-menu contains the data monitor and the bit monitor. The data monitor allows you to examine the contents of memory registers or pointers to determine their contents. The default format is BCD/HEX, but the format can be changed to decimal by setting bit 8 of V7742. Please refer to the DL06 Memory Map for ranges.

Step 3.2

> M 2 : S Y S T E M C F G . > M 3 : MO N I T O R

V-memory values

10–10

Use the right or left arrow key to move the cursor to the digit you want to change. Use the up or down arrow key to change the digit. The V-memory address is expressed as an octal number so you will not see 8’s or 9’s. This screen allows you to view two adjacent V-memory locations in BCD format. The lower word is to the right. Pressing ENT makes it possible to change the value in the lower word. At this level of the menu hierarchy, you can also use the up and down arrow keys to scroll to other memory locations.

MENU

M 3 : > D A T A > B I T

ESC

Data Monitor Data type = V for V-memory or P for pointer. Press MENU to change data type, or press ENT to designate the register whose data you want to view or change.

ESC

ENT

MO N I T O R MO N I T O R

MENU

ENT

Step 3.3 M 3 : D A T A A D D R E S S

Step 3.4

ESC

M 3 : D A T A A D D R E S S

Step 3.5 M 3 : V V A L

ESC

T Y P E V 0 0 0 0 0

MENU

ENT

T Y P E V 0 0 0 0 0

MENU

1 0 0 0 0

ENT

V

0 0 0 0 0

The data values on this screen will be four digits in length for BCD/HEX unless bit 8 of V7742 is set. Bit 8 of V7742 changes the data format to decimal (five digits).

DL06 Micro PLC User Manual, 3rd Edition Rev. A

Page 185

Chapter 10: LCD Display Panel

Step 3.6 Use the right or left arrow key to move the cursor to the digit you want to change. Use the up or down arrow key to move to another digit. The V-memory value is expressed as a BCD number so you will see values (in the range: 0 - F) available for each digit. The data format can be changed to decimal by setting bit 8 of V7742.

ESC

MENU

M 3 : D A T A V C H G = 0 0 0 0

Step 3.7

ESC

MENU

M 3 : V V A L

Returns to Step 1.1

ESC

MENU

MENU

M 3 : D A T A A D D R E S S

Returns to default screen D L 0 6

ESC

0 0 0 0 0

ENT

1 0 0 0 0

ESC

0 0 0 0 0

ENT

M 3 : D A T A V C H G = A F 0 6

Step 3.8

Push the ESC key five (5) times to return to the default screen.

ENT

V

0 A F 0 6

ENT

T Y P E V 0 0 0 0 0

MENU

P L C

ENT

M a y 0 8 1 5 : 0 2 : 1 3

DL06 Micro PLC User Manual, 3rd Edition Rev. A

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D

10–11

Page 186

Chapter 10: LCD Display Panel

Pointer values

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D 10–12

Press ESC twice to return to the Step 3.3 screen with the cursor on the V, as shown. Use the up or down arrow key to change the V to P. Now, the pointer information is displayed.

Return to Step 3.3 M 3 : D A T A A D D R E S S

Step 3.4a

T Y P E V 0 0 0 0 0

ESC

MENU

M 3 : D A T A A D D R E S S

Use the up or down arrow keys to change the value of the current digit. Use the left or right arrow keys to move from one digit to the next.

Step 3.5a

ESC

T Y P E P 0 0 0 0 0

MENU

M 3 : D A T A A D D R E S S

Step 3.6a

ESC

To change from the data monitor to the bit monitor, press ESC three times to return to Step 3.2 (five times to return to the default screen).

Step 3.7a

ESC

ENT

T Y P E P 0 0 0 0 0

MENU

M 3 : D A T A A D D R E S S

At Step 3.7a, the up and down arrow keys can be used to cycle through data words. Each time you press the up or down arrow key, the address increments or decrements by one 16-bit word (addresses are expressed in octal).

ENT

ENT

T Y P E P 1 0 0 0 0

MENU

ENT

M 3 : D A T A P 1 0 0 0 0 ( V 0 0 0 0 0 ) 2 0 0 0

Return to Step 3.3

ESC

MENU

M 3 : > D A T A > B I T

DL06 Micro PLC User Manual, 3rd Edition Rev. A

ENT

MO N I T O R MO N I T O R

Page 187

Chapter 10: LCD Display Panel

Bit Monitor

Return to Step 3.3

Bit status From Step 3.3, press the up or down arrow key, then the ENT key. You will see one of eleven bit data types displayed. The data type that appears on the display is the last data type accessed. The address shown is also the last address accessed for that particular data type. Press ENT to change the address.

M 3 : D A T A A D D R E S S

T Y P E P 0 0 0 0 0

Return to Step 3.3

ENT

ESC

MENU

M 3 : B I T A D D R E S S

ESC

Use the arrow keys to change the address as necessary.

M 3 : B I T A D D R E S S

ESC

Press ENT to view the selected bits.

M 3 : B I T A D D R E S S

ESC

Use the left and right arrow keys to select a bit whose status you want to change. Press ENT once to see the change status screen. Press ENT again to change the status from OFF to ON or ON to OFF.

ESC

MENU

ENT

T Y P E V 0 0 0 0 0

MENU

ENT

T Y P E C 0 0 0 0 0

MENU

ENT

T Y P E V 0 2 5 0 0

MENU

ENT

M 3 : B I T - 0 0 V 2 5 0 0 o o o o o o o o o o o o o o o o

ESC

MENU

ENT

M 3 : B I T - 0 2 V 2 5 0 0 C H G = O N S T A T : O F F

DL06 Micro PLC User Manual, 3rd Edition Rev. A

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D

10–13

Page 188

Chapter 10: LCD Display Panel

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D

Changing Date and Time Menu 4, M4 : CALENDAR R/W

10–14

From the default screen, press the MENU key four times to arrive at Step 4.1.

Step 4.1 > M 3 : D A T A T Y P E > M 4 : C A L E N D A R R / W

Step 4.2

ESC

M 4 : D A T E T I M E

Step 4.3

ESC

MENU

ENT

0 5 - 0 8 - 0 2 0 1 : 2 1 : 2 8

MENU

ENT

M 4 : > C H A N G E > C H A N G E

Step 4.4 At Step 4.4, use the up and down arrows to change the value for month, day, or year. Use the left and right arrow keys to move between the different digits in the date. After making the necessary changes using the arrow keys, press the ENT key to register the changes.

M 4 : D A T E C H G =

Step 4.5 You will be asked if you want to set the date to the chosen value. Press ENT again if the date is correct. You will automatically return to Step 4.2, and the new date will be displayed.

ESC

ESC

M 4 : D A T E S E T ?

ESC

DL06 Micro PLC User Manual, 3rd Edition Rev. A

MENU

D A T E T I M E

ENT

MM - D D - Y Y 0 5 - 0 8 - 0 2

MENU

ENT

MM - D D - Y Y 0 5 - 0 8 - 0 2

MENU

ENT

Page 189

Chapter 10: LCD Display Panel

Returns to Step 4.2 In order to change the time or date/time format, press ENT again at Step 4.2.

M 4 : D A T E T I M E

ESC

Use the up or down arrow keys or the MENU key to scroll through the submenu choices. At this point in our example, we will change the time setting.

0 5 - 0 8 - 0 2 0 1 : 2 1 P M

MENU

ENT

M 4 : > C H A N G E > C H A N G E

ESC

MENU

ENT

M 4 : > C H A N G E > C H A N G E

At Step 4.4, use the up and down arrows to change the value for hour, minute, or second. Use the left and right arrow keys to move between the different digits in the time. After making the necessary changes using the arrow keys, press the ENT key to register the changes.

ESC

M 4 : T I M E C H G =

ESC

You will be asked if you want to set the date to the chosen value. Press ENT again if the date is correct. You will automatically return to Step 4.2, and the new date will be displayed.

M 4 : T I M E S E T ?

ESC

MENU

D A T E T I M E

T I M E F O R MT

ENT

H H : MM : S S 1 3 : 5 3 : 3 2

MENU

ENT

H H : MM : S S 1 3 : 5 3 : 3 2

MENU

ENT

DL06 Micro PLC User Manual, 3rd Edition Rev. A

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D

10–15