Page 190

Chapter 10: LCD Display Panel

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D 10–16

If you want to change the format for the date or time, return to Step 4.2 and press ENT.

Press ENT, MENU, MENU to arrive at the menu selection for changing the date or time formats. Press ENT again to enter the format changing location.

Press ENT again to enter the date format changing location, or press MENU, ENT to change the time format.

At Step 4.4, use the up and down arrow keys to scroll through the date formats. The choices are as follows: MM-DD-YY (US format)

Returns to Step 4.2 M 4 : D A T E T I M E

ESC

0 5 - 0 8 - 0 2 0 1 : 2 1 P M

MENU

ENT

M 4 : > C H A N G E > C H A N G E

ESC

MENU

M 4 : > D A T E > T I M E

ESC

F O R MT D A T E

ENT

F O R M A T F O R M A T

MENU

ENT

M 4 : D A T E C H G =

F O R M A T MM - D D - Y Y

M 4 : T I M E

F O R M A T

DD-MM-YY (European format) YY-MM-DD (Asian format)

Press the ENT key to save the format C H G = H H : MM : S S changes. If you have chosen to make a time format change, your choices are: HH:MM US (12 hour 12:00 - 11:59AM/PM US format ) HH:MM AS (12 hour 00:00 - 11:59AM/PM Asian format ) HH:MM:SS (24 hour format)

Press the ENT key to save the format changes. Press ESC until the default screen reappears. Date and Time Variables and Formats _date:us _date:e _date:a _time:12 _time:24

DL06 Micro PLC User Manual, 3rd Edition Rev. A

US format European format Asian format 12 hour format 24 hour format

MM/DD/YY DD/MM/YY YY/MM/DD HH:MMAM/PM HH:MM:SS

Page 191

Chapter 10: LCD Display Panel

Setting Password and Locking

1 Menu 5, M5 : PASSWORD R/W The LCD Display Panel has its own password protection separate from the “ladder password” 2 protection of the PLC. An LCD Display password can be used to prevent unauthorized changes to clock and calendar setup and V-memory data values. Individuals with password 3 authorization can change clock, calendar, V-memory values, force bits on or off, etc. The LCD password inhibits unauthorized personnel from modifying the data in the DL06 with the LCD keypad. Even though the LCD password is locked, the user can still modify the 4 data in the DL06 with DirectSOFT 5 or the D2-HPP. The LCD Display Panel does not support the multi-level password. 5 Only menu 5 on the LCD Display can modify the LCD password. WARNING: The password protection available in DirectSOFT 5 or the HPP does not prevent 6 changes from the LCD Display Panel. To prevent changes from the LCD Display Panel, it is necessary to use the LCD password locking feature. 7 WARNING: The LCD password is apparently entered into the PLC, with no possibility to clear it. If you forget your LCD password, a new PLC must be purchased. 8 9 Step 5.1 Use the MENU key to navigate to the M5 menu option. Press ENT to arrive > M 4 : C A L E N D A R R / W at the display shown as Step 5.2. 10 > M 5 : P A S SWO R D R / W Assigning a password without locking the display allows access to all features 11 and capabilities of the LCD. Use the up arrow or down arrow keys 12 to toggle between PASSWD CHG? Step 5.2 and LOCK/UNLOCK? Eight zeroes M 5 : > P A S SWD C H G ? removes the password. If the password 13 > L O C K / U N L O C K ? is eight zeroes, the display will not LOCK. 14 A B M 5 : > P A S SWD C H G ? > L O C K / U N L O C K ? C D ESC

MENU

ENT

ESC

MENU

ENT

ESC

MENU

ENT

DL06 Micro PLC User Manual, 3rd Edition Rev. A

10–17

Page 192

Chapter 10: LCD Display Panel

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D 10–18

Use the up arrow or down arrow keys to scroll through number choices, and use the right arrow and left arrow keys to move from one digit position to another.

M 5 : P SWD C H G =

* * * * * * * * 0 0 0 0 0 0 0 0

NOTE: It is important to record the password where it will not be forgotten and to issue the password only to qualified personnel. Full access to the LCD Display Panel gives access to change data values within the PLC.

M 5 : P SWD C H G =

ESC

M 5 : P SWD S E T ?

Return to Step 5.2

ESC

* * * * * * * * 2 1 7 0 8 3 0 3

MENU

ENT

* * * * * * * * 2 1 7 0 8 3 0 3

MENU

ENT

M 5 : > P A S SWD C H G ? > L O C K / U N L O C K ?

It is not possible to lock the display without assigning a password. It is possible to assign a password without locking the display, but doing so will not protect sensitive data. Press the ENT key at Step 5.2, and the display is now locked. If you do not wish to lock the display at this point, press ESC.

ESC

MENU

ENT

M 5 : S T A T : U N L O C K E D E N T T O L O C K

DL06 Micro PLC User Manual, 3rd Edition Rev. A

ESC

MENU

ENT

Page 193

Chapter 10: LCD Display Panel

Before assigning a password, you can select “Lock/Unlock” by pressing ENT at Step 5.2.

Return to Step 5.2 M 5 : > P A S SWD C H G ? > L O C K / U N L O C K ?

ESC

MENU

ENT

M 5 : S T A T : U N L O C K E D E N T T O L O C K

ESC

Here, the display prompts you to enter a password.

M 5 : P SWD L O C K

MENU

ENT

* * * * * * * * 0 0 0 0 0 0 0 0

DL06 Micro PLC User Manual, 3rd Edition Rev. A

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D

10–19

Page 194

Chapter 10: LCD Display Panel

1 Reviewing Error History Menu 6, M6 : ERR HISTORY 2 From the default screen, press the MENU key six times to arrive at Step 6.1. 3 4 5 The Error History screen will display “NO ERROR” if there is no record of 6 errors. If errors have occurred, they can be identified by their Error Code. The Error Code table (see appendix B) will 7 explain the source of the error message. The last 16 messages are displayed.Error 8 messages are displaced when a new error message arrives 9 10 11 To review past error messages use the down arrow key to scroll through the historical record of error messages. 12 13 14 A B C D 10–20

Default screen Step 6.1 > M 5 : P A S SWO R D R / W > M 6 : E R R H I S T O R Y

ESC

MENU

ENT

M 6 : E R R O R H I S T O R Y N O E R R O R

D i a g n o s t i c E r r o r E 4 * * N O P R O G R A M

ESC

M 6 : E r r . E 4 0 1

DL06 Micro PLC User Manual, 3rd Edition Rev. A

MENU

ENT

0 5 - 2 2 - 0 2 1 0 : 4 3 A M

Page 195

Chapter 10: LCD Display Panel

Toggle Light and Beeper, Test Keys Menu 7, M7 : LCD TEST&SET This menu selection gives you an opportunity to: • Test each LCD key to assure that the PLC is receiving its input appropriately • Turn the beep sound off or on • Turn the LCD back light off or on Make a menu selection by pressing the ENT key.

> M 6 : E R R > M 7 : L C D

ESC

Press ENT to enter the LCD KEY TEST. All keys can be tested for proper function in this menu. To return to the menu, press the ESC key twice or hold the ESC key down until the menu layer reappears.

ENT

MENU

ENT

M 7 : L C D T E S T & S E T > B A C K L I G H T

ESC

The piezo electric buzzer can be configured to provide pushbutton feedback.

MENU

M 7 : L C D T E S T & S E T > L C D K E Y T E S T

ESC

Press ENT to enter the Back light test menu.

H I S T O R Y T E S T & S E T

MENU

ENT

M 7 : L C D T E S T & S E T > B E E P

DL06 Micro PLC User Manual, 3rd Edition Rev. A

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D

10–21

Page 196

Chapter 10: LCD Display Panel

PLC Memory Information for the LCD Display Panel

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D

The valid memory ranges for storing text messages in the DL06 are: V400 - V677

V1200 - V7577

V10000 - V17777

Data Format Suffixes for Embedded V-memory Data

10–22

Several data formats are available for displaying V-memory data on the LCD. The choices are shown in the table below. A colon is used to separate the embedded V-memory location from the data format suffix and modifier. Data Format

Modifier none (16 bit binary S in HEX format) C0 0

:B (4 digit BCD)

S C0 0

:D (32 bit binary) S C0 0

:DB (8 digit BCD)

S C0 0

:R (Floating point number) S C0 0

:E (Floating point number with S exponent) C0 0

Example

Character Position/Content of the Output

V2000 = 0012 1 2 3 4 V2000 s s 1 8 [:S] V2000:S 1 8 [:C0] V2000:C0 0 0 1 8 [:0] V2000:0 s s 1 8 V2000 = 0012 1 2 3 4 [:B] V2000:B 0 0 1 2 [:BS] V2000:BS 1 2 [:BC0] V2000:BC0 0 0 1 2 [:B0] V2000:B0 s s 1 2 V2000 = 0000 V2001 = 0001 1 2 3 4 5 6 7 [:D] V2000:D s s s s s s 6 [:DS] V2000:DS 6 5 5 3 6 [:DC0] V2000:DC0 0 0 0 0 0 0 6 [:D0] V2000:D0 s s s s s s 6 V2000 = 0000 V2001 = 0001 1 2 3 4 5 6 7 [:DB] V2000:DB 0 0 0 1 0 0 0 [:DBS] V2000:DBS 1 0 0 0 0 [:DBC0] V2000:DBC0 0 0 0 1 0 0 0 [:DB0] V2000:DB0 s s s 1 0 0 0 Value = 222.11111 V2000 = 1C72 V2001 = 435E 1 2 3 4 5 6 7 [:R] V2000:R s s s f 2 2 2 [:RS] V2000:RS f 2 2 2 . 1 1 [:RC0] V2000:RC0 f 0 0 0 2 2 2 [:R0] V2000:R0 s s s f 2 2 2 Value = 222.1 V2000 = 199A V2001 = 435E 1 2 3 4 5 6 7 [:E] V2000:E s f 2 . 2 2 1 [:ES] V2000:ES f 2 . 2 2 1 0 [:EC0] V2000:EC0 f 2 . 2 2 1 0 [:E0] V2000:E0 f 2 . 2 2 1 0 s = space f = plus/minus flag (plus = no symbol, minus = - )

DL06 Micro PLC User Manual, 3rd Edition Rev. A

8

9 10 11

5

5

3

6

5 5

5 5

3 3

6 6

8 0 0 0

8

9 10 11 12 13

. 1 . .

1 1 1 1

8

9 10 11 12 13

0 0 0 0

0 E E E

1 1 1 1

E + + +

1

1

1

1 1

1 1

1 1

+ 0 0 0

0 2 2 2

2

Page 197

Chapter 10: LCD Display Panel

The S, C0 and 0 modifiers alter the presentation of leading zeros and spaces. S removes leading spaces and left justifies the result. C0 replaces leading spaces with leading zeros. 0 is a modification of C0. 0 eleminates any leading zeros in the C0 format version and converts them to spaces.

1 2 Reserved memory registers for the LCD Display Panel 3 Two V-memory registers are reserved for making changes to LCD functions via ladder logic. V7742 allows for bit flags to be set in the ladder program. The bit flags control such things as 4 data formats, the back light, and the beeper. All V7742 bit flags are defined in the table on the next page. 5 The other reserved register is V7743. This register is used to write a customized default screen message to the LCD. A sample program for this purpose is illustrated later in this chapter. 6 V-memory address Contents 7 Various LCD flags 8 V7742 9 V7743 10 The following program segment uses the SET and RST coils to turn on and off bit 12 of 11 V7742. When C0 is on, bit 12 is turned on. Bit 12 turns on the beeper in the LCD Display Panel. The C1 contact resets bit 12 to the off state. 12 13 14 A B C D • Calendar date and time format • Default operation menu • Data format of data monitor • LCD password status flag • Key press acknowledgement buzzer on/off setting • Back light on/off setting Default message location (writing 0 to this address returns the default message to the factory setting)

C0

B7742.12

SET

C1

B7742.12

RST

DL06 Micro PLC User Manual, 3rd Edition Rev. A

10–23

Page 198

Chapter 10: LCD Display Panel

V7742 bit definitions

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D 10–24

Bit

15 14 13 12 11 10

9

8

7

6

5

4

3

2

1

0

*

0

0

0

0

0

0

0

0

0

0

V7742

1

0

0

0

0

Date display format (default = 00) Bit 1, 0

00, 11 01 10

= Month/Day/Year (US format) = Day/Month/Year (EU format) = Year/Month/Day (Asian format)

Bit 3, 2

00, 11 01 10

= HH:MM:SS (24 hour format) = HH:MM PM/AM (12 hour US format - 12:00 - 11:59) = HH:MM PM/AM (12 hour Asian format - 00:00 - 11:59)

Time display format (default = 00)

Default menu setting (default = 000)

Bit 6 - 4

000 001 010 011 100 101 110 111

= = = = = = = =

Default menu sequence, begins menu sequence with Menu 1 Begin menu sequence with Menu 1 Begin menu sequence with Menu 2 Begin menu sequence with Menu 3 Begin menu sequence with Menu 4 Begin menu sequence with Menu 5 Begin menu sequence with Menu 6 Begin menu sequence with Menu 7

0 1

= BCD/HEX format (0000 - FFFF) = Decimal format (00000 - 65535)

Data monitor format (default = 0) Bit 8

New message overwrite (default = 0) Bit 9

0 1

= New LCD message clears both lines of previous message = New LCD message leaves previous message, overwrites specified char. only

Bit 11

0 1

= Password unlock = Password lock

Bit 12

0 1

= Beep OFF = Beep ON (LCD beeps continuously during ON status of this flag)

Bit 13

0 1

= Beep OFF = Beep ON (LCD beeps when keys are pressed)

LCD password status flag (Read only)

Status flag beep on/off control (default = 0)

Keypad beep on/off control (default = 0)

LCD back light setting flag (default = 1) Bit 14

0 1

= Light OFF = Light ON

Bit 15

0 1

= LCD is not installed = LCD is installed

LCD installed status flag (Read only)

DL06 Micro PLC User Manual, 3rd Edition Rev. A

Page 199

Chapter 10: LCD Display Panel

Changing the Default Screen

Factory default message

1 2 3 4 Example program for setting the default screen message The following program can be used to set up the default screen message. This program uses the VPRINT instruction to load ASCII text to a designated V-memory location and to 5 embed a pointer to the current date. The LDA and OUT instructions are used to point to the V-memory location (+1) where the 6 text is located. The memory location V7743 is reserved for the pointer to the default message. NOTE: The VPRINT instruction adds a one word (2 bytes) non-printing header to the text. For this reason, 7 the LDA instruction points to the V-memory location V10001 rather than V10000. 8 V10000 V10001 9 V10002 V10003 V10004 10 V10005 V10006 11 V10007 V10010 12 V10011 V10012 13 V10013 V10014 14 V10015 V10016 V10017 A V10020 B After running this program, press MENU, then ESC or cycle power. The new default message should look as indicated. See Menu A u t o m a t i o n D i r e c t C 4 instructions for changing date and time information. D NOTE: It is possible to return to the factory default screen by writing 0 to V7743 and cycling power. At power-up the default screen is displayed. The default screen message is set at the factory but can be customized by the user. One method of customizing the default message uses the VPRINT instruction. The VPRINT instruction is described in Chapter 5.

SP0

SP0

VPRINT Byte Swap: "Print to" Address: "AutomationDirect"

None V10000

LDA

O10001

OUT

D L 0 6

P L C

M a y 0 8 1 4 : 2 0 : 4 9

00h

16h u

A o t a m i t n o i

D e r t c

V7743 END

DL06 Micro PLC User Manual, 3rd Edition Rev. A