Page 220
Appendix B: DL06 Error Codes DL06 Error Code
1 B 3 4 5 6 7 8 9 10 11 12 13 14 A B C D
Description
E526 OFF LINE
The handheld programmer is in the OFFLINE mode. To change to the ONLINE mode use the MODE key.
E527 ON LINE
The handheld programmer is in the ON LINE mode. To change to the OFF LINE mode use the MODE key.
E528 CPU MODE
The operation attempted is not allowed during a Run Time Edit.
E540 CPU LOCKED
The DL06 has been password locked. To unlock the DL06 use AUX82 with the password.
E541 WRONG PASSWORD
The password used to unlock the DL06 with AUX82 was incorrect.
E542 PASSWORD RESET
The DL06 powered up with an invalid password and reset the password to 00000000. A password may be re-entered using AUX81.
E601 MEMORY FULL
Attempted to enter an instruction which required more memory than is available in the DL06.
E602 INSTRUCTION MISSING
A search function was performed and the instruction was not found.
E603 DATA MISSING
A search function was performed and the data was not found.
E604 REFERENCE MISSING
A search function was performed and the reference was not found.
E610 BAD I/O TYPE
The application program has referenced an I/O module as the incorrect type of module.
E620 OUT OF MEMORY
An attempt to transfer more data between the DL06 and handheld programmer than the receiving device can hold.
E621 EEPROM NOT BLANK
An attempt to write to a non-blank EEPROM in the handheld programmer was made. Erase the EEPROM and then retry the write.
E622 NO HPP EEPROM
A data transfer was attempted with no EEPROM (or possibly a faulty EEPROM) installed in the handheld programmer.
E623 SYSTEM EEPROM
A function was requested with an EEPROM in the handheld programmer which contains system information only.
E624 V-MEMORY ONLY
A function was requested with an EEPROM in the handheld programmer which contains V-memory data only.
E625 PROGRAM ONLY
A function was requested with an EEPROM in the handheld programmer which contains program data only.
E627 BAD WRITE
An attempt to write to a faulty EEPROM in the handheld programmer was made. Replace the EEPROM if necessary.
E628 EEPROM TYPE ERROR
The wrong size EEPROM is being used.
E640 COMPARE ERROR
A compare between the EEPROM handheld programmer and the DL06 was found to be in error.
E642 CHECKSUM ERROR
An error was detected while data was being transferred to the handheld programmer’s EEPROM. Check cabling and retry the operation.
E650 HPP SYSTEM ERROR
A system error has occurred in the handheld programmer. Power cycle the handheld programmer. If the error returns replace the handheld programmer.
E651 HPP ROM ERROR
A ROM error has occurred in the handheld programmer. Power cycle the handheld programmer. If the error returns replace the handheld programmer.
E652 HPP RAM ERROR
A RAM error has occurred in the handheld programmer. Power cycle the handheld programmer. If the error returns replace the handheld programmer.
B–6
DL06 Micro PLC User Manual, 3rd Edition Rev. A
Page 221
PPENDIX
C
Introduction ........ 0. ce ee eee eee eee ee eee eens C2
INSTRUCTION EXECUTION TIMES
In This Appendix...
Instruction Execution Times ............. 0.0 cee eee ee eee eee C-3
Page 222
Appendix C: Instruction Execution Times
Introduction
1 2 C 4 5 6 7 8 9 10 11 12 13 14 A B C D
This appendix contains several tables that provide the instruction execution times for DL06 Micro PLCs. Many of the execution times depend on the type of data used with the instruction. Registers may be classified into the following types: • Data (word) Registers • Bit Registers
V-Memory Data Registers Some V-memory locations are considered data registers, such as timer or counter current values standard user V-memory is classified as a V-memory data register. Note that you can load a bit pattern into these types of registers, even though their primary use is for data registers. The following locations are data registers: Data Registers
DL06
Timer Current Values Counter Current Values
V0 - V377 V1000 - V1177 V400 - V677 V1200 - V7377 V10000 - V17777
User Data Words
V-Memory Bit Registers You may recall that some of the discrete points such as X, Y, C, etc. are automatically mapped into V-memory. The following bit registers contain this data: Bit Registers
DL06
Input Points (X) Output Points (Y) Control Relays (C) Stages (S) Timer status Bits Counter status Bits Special Relays (SP)
V40400 - V40437 V40500 - V40537 V40600 - V40677 V41000 - V41077 V41100 - V41177 V41140 - V41147 V41200 - V41237
How to Read the Tables
C–2
Some instructions can have more than one parameter. For example, the SET instruction shown in the ladder program to the right can set a single point or a range of points. In these cases, execution times depend on the amount and type of parameters. The execution time tables list execution times for both situations, as shown below: SET RST
1st #: X, Y, C, 2nd #: X, Y, C, S 1st #: X, Y, C, 2nd #: X, Y, C, S
(N pt) (N pt)
9.2 µs 9.6 µs + 0.9 V x N 9.2 µs 9.6 µs + 0.9 V x N
DL06 Micro PLC User Manual, 3rd Edition Rev. A
Two Data Locations Available X0
X1
Y0 – Y7 SET
C0
Execution depends on numbers of locations and types of data used
Page 223
Appendix C: Instruction Execution Times
Instruction Execution Times Boolean Instructions Boolean Instructions Instruction STR STRN OR ORN AND ANDN ANDSTR ORSTR OUT OROUT NOT SET
RST
PAUSE
DL06
Legal Data Types
Execute
Not Execute
X, Y, C, T, CT, S,SP, GX, GY X, Y, C, T, CT, S,SP, GX, GY X, Y, C, T, CT, S,SP, GX, GY X, Y, C, T, CT, S,SP, GX, GY X, Y, C, T, CT, S,SP, GX, GY X, Y, C, T, CT, S,SP, GX, GY None None X, Y, C, GX, GY X, Y, C, GX, GY None 1st #: X, Y, C, S, 2nd #: X, Y, C, S (N pt) 1st #: X, Y, C,S, GX, GY 2nd #: X, Y, C,S (N pt), GX, GY 1st #: T, CT, GX, GY 2nd #: T, CT (N pt), GX, GY 1wd: Y 2wd: Y (N points)
0.67 µs 0.67 µs 0.51 µs 0.55 µs 0.42 µs 0.51 µs 0.37 µs 0.37 µs 1.82 µs 2.09 µs 1.04 µs 9.2 µs 9.6 µs+0.9 µs x N 9.2 µs 9.6 µs+0.9 µs x N 25.7 µs 16.8 µs + 2.7 µs x N 5.6 µs 9.2 µs + 0.3 µs x N
0.00 µs 0.0 µs 0.51 µs 0.55 µs 0.42 µs 0.51 µs 0.37 µs 0.37 µs 1.82 µs 2.09 µs 1.04 µs 1.0 µs 1.1 µs 1.0 µs 1.1 µs 1.1 µs 1.4 µs 5.4 µs 4.8 µs
DL06 Micro PLC User Manual, 3rd Edition Rev. A
1 2 C 4 5 6 7 8 9 10 11 12 13 14 A B C D C–3
Page 224
Appendix C: Instruction Execution Times
Comparative Boolean Instructions
1 2 C 4 5 6 7 8 9 10 11 12 13 14 A B C D C–4
Comparative Boolean Instructions Instruction
Legal Data Types 1st 2nd V Data Reg. V:Data Reg. V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)
DL06 Execute
Not Execute
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
V: Bit Reg.
V:Data Reg. V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
P:Indir. (Data)
V:Data Reg V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)
29.9 µs 29.9 µs 27.7 µs 51.0 µs 51.0 µs
29.9 µs 29.9 µs 27.7 µs 51.0 µs 51.0 µs
P:Indir. (Bit)
V:Data Reg V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)
29.9 µs 29.9 µs 27.7 µs 51.0 µs 51.0 µs
29.9 µs 29.9 µs 27.7 µs 51.0 µs 51.0 µs
1st V: Data Reg.
2nd V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
V: Bit Reg.
V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
P:Indir. (Data)
V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)
30.3 µs 30.3 µs 27.4 µs 51.0 µs 51.0 µs
30.3 µs 30.3 µs 27.4 µs 51.0 µs 51.0 µs
P:Indir. (Bit)
V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)
30.3 µs 30.3 µs 27.4 µs 51.0 µs 51.0 µs
30.3 µs 30.3 µs 27.4 µs 51.0 µs 51.0 µs
STRE
STRNE
DL06 Micro PLC User Manual, 3rd Edition Rev. A
Page 225
Appendix C: Instruction Execution Times
Comparative Boolean Instructions (cont’d) Comparative Boolean Instructions Instruction
DL06
Legal Data Types 1st 2nd V:Data Reg V Data Reg V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)
Execute
Not Execute
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
V: Bit Reg.
V:Data Reg. V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
P:Indir. (Data)
V:Data Reg V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)
30.3 µs 30.3 µs 27.4 µs 50.4 µs 50.4 µs
30.3 µs 30.3 µs 27.4 µs 50.4 µs 50.4 µs
P:Indir. (Bit)
V:Data Reg V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)
30.3 µs 30.3 µs 27.4 µs 50.4 µs 50.4 µs
30.3 µs 30.3 µs 27.4 µs 50.4 µs 50.4 µs
1st Data Reg.
2nd V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
V: Bit Reg.
V:Data Reg V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
P:Indir. (Data)
V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)
29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs
29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs
P:Indir. (Bit)
V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)
29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs
29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs
ORE
ORNE
DL06 Micro PLC User Manual, 3rd Edition Rev. A
1 2 C 4 5 6 7 8 9 10 11 12 13 14 A B C D C–5
Page 226
Appendix C: Instruction Execution Times
1 2 C 4 5 6 7 8 9 10 11 12 13 14 A B C D C–6
Comparative Boolean Instructions (cont’d) Comparative Boolean Instructions Instruction
ANDE
ANDNE
DL06
Legal Data Types 1st 2nd V Data Reg. V:Data Reg V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)
Execute
Not Execute
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
V: Bit Reg.
V:Data Reg V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
P:Indir. (Data)
V:Data Reg V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)
29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs
29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs
P:Indir. (Bit)
V:Data Reg V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)
29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs
29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs
1st V: Data Reg.
2nd V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
V: Bit Reg.
V:Data Reg. V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
P:Indir. (Data)
V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)
29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs
29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs
P:Indir. (Bit)
V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)
29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs
29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs
DL06 Micro PLC User Manual, 3rd Edition Rev. A
Page 227
Appendix C: Instruction Execution Times
Comparative Boolean Instructions (cont’d) Comparative Boolean Instructions Instruction 1st T, CT
STR
Legal Data Types 2nd V:Data Reg. V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)
Execute
Not Execute
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
V Data Reg
V:Data Reg. V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
V: Bit Reg.
V:Data Reg. V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
P:Indir. (Data)
V:Data Reg. V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)
29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs
29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs
V:Data Reg V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)
29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs
29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs
1st T, CT
2nd V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
V: Data Reg.
V:Data Reg. V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
P:Indir. (Bit)
STRN
DL06
DL06 Micro PLC User Manual, 3rd Edition Rev. A
1 2 C 4 5 6 7 8 9 10 11 12 13 14 A B C D C–7
Page 228
Appendix C: Instruction Execution Times
Comparative Boolean Instructions (cont’d)
1 2 C 4 5 6 7 8 9 10 11 12 13 14 A B C D C–8
Comparative Boolean Instructions Instruction
STRN (cont.)
DL06
Legal Data Types 1st 2nd V: Bit Reg V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)
Execute
Not Execute
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
P:Indir. (Data)
V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)
29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs
29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs
P:Indir. (Bit)
V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)
29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs
29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs
1st T, CT
2nd V Data Reg V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
V Data Reg.
V:Data Reg. V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
V: Bit Reg.
V:Data Reg. V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
P:Indir. (Data)
V:Data Reg V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)
29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs
29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs
P:Indir. (Bit)
V:Data Reg V:Bit Reg K:Constant P:Indir. (Data P:Indir. (Bit)
29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs
29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs
OR
DL06 Micro PLC User Manual, 3rd Edition Rev. A
Page 229
Appendix C: Instruction Execution Times
Comparative Boolean Instructions (cont’d) Comparative Boolean Instructions Instruction 1st T, CT
ORN
Legal Data Types 2nd V:Data Reg. V:Bit Reg K:Constant P:Indir. (Data P:Indir. (Bit)
DL06 Execute
Not Execute
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
V: Data Reg
V:Data Reg V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
V: Bit Reg.
V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs
P:Indir. (Data)
V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)
29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs
29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs
P:Indir. (Bit)
V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)
29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs
29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs
DL06 Micro PLC User Manual, 3rd Edition Rev. A
1 2 C 4 5 6 7 8 9 10 11 12 13 14 A B C D C–9