Page 230

Appendix C: Instruction Execution Times

Comparative Boolean Instructions (cont’d)

1 2 C 4 5 6 7 8 9 10 11 12 13 14 A B C D C–10

Comparative Boolean Instructions Instruction 1st T, CT

AND

Legal Data Types 2nd V Data Reg. V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)

DL06 Execute

Not Execute

7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs

7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs

V: Data Reg.

V:Data Reg V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)

7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs

7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs

V: Bit Reg.

V:Data Reg. V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)

7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs

7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs

P:Indir. (Data)

V:Data Reg V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)

29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs

29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs

P:Indir. (Bit)

V:Data Reg V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)

29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs

29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs

DL06 Micro PLC User Manual, 3rd Edition Rev. A

Page 231

Appendix C: Instruction Execution Times

Comparative Boolean Instructions (cont’d) Comparative Boolean Instructions Instruction 1st T, CT

ANDN

Legal Data Types 2nd V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)

DL06 Execute

Not Execute

7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs

7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs

V: Data Reg.

V:Data Reg V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)

7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs

7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs

V: Bit Reg.

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)

7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs

7.6 µs 7.6 µs 4.8 µs 30.2 µs 30.2 µs

P:Indir. (Data)

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)

29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs

29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs

P:Indir. (Bit)

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)

29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs

29.9 µs 29.9 µs 27.4 µs 51.0 µs 51.0 µs

Immediate Instructions Immediate Instructions

DL06

Instruction

Legal Data Types

Execute

Not Execute

LDI LDIF STRI STRNI ORI ORNI ANDI ANDNI OUTI OROUTI OUTIF SETI RSTI

V 1st #: Y 2nd #: K Constant X X X X X X Y Y 1st #: Y 2nd #: Y (N pt) 1st #: Y 2nd #: K Constant 1st #: Y 2nd #: Y (N pt)

20.6 µs 26.6 µs+0.9µs x N 19.3 µs 19.4 µs 19.1 µs 19.2 µs 18.7 µs 18.8 µs 25.5 µs 25.7 µs 66.1 µs+0.9µs x N 23.1 µs, 22.8 µs+1.4µsxN 23.2 µs, 22.8 µs+1.4µsxN

1.1 µs 1.4 µs 19.3 µs 19.4 µs 18.7 µs 18.9 µs 18.7 µs 18.8 µs 25.5 µs 25.7 µs 1.4 µs 0.9 µs, 0.9 µs 0.9 µs, 0.9 µs

DL06 Micro PLC User Manual, 3rd Edition Rev. A

1 2 C 4 5 6 7 8 9 10 11 12 13 14 A B C D C–11

Page 232

Appendix C: Instruction Execution Times

Bit of Word Boolean Instructions

1 2 C 4 5 6 7 8 9 10 11 12 13 14 A B C D C–12

Bit of Word Boolean Instructions Instruction

Legal Data Types

DL06 Execute

Not Execute

STRB

V:Data Reg. V:Bit Reg. P:Indir. (Data) P:Indir. (Bit)

3.1 µs 3.1 µs 30.0 µs 30.0 µs

3.1 µs 3.1 µs 30.0 µs 30.0 µs

STRNB

V:Data Reg. V:Bit Reg. P:Indir. (Data) P:Indir. (Bit)

3.0 µs 3.0 µs 29.8 µs 29.8 µs

3.0 µs 3.0 µs 29.8 µs 29.8 µs

ORB

V:Data Reg. V:Bit Reg. P:Indir. (Data) P:Indir. (Bit)

2.9 µs 2.9 µs 29.9 µs 29.9 µs

2.9 µs 2.9 µs 29.9 µs 29.9 µs

ORNB

V:Data Reg. V:Bit Reg. P:Indir. (Data) P:Indir. (Bit)

2.8 µs 2.8 µs 29.6 µs 29.6 µs

2.8 µs 2.8 µs 29.6 µs 29.6 µs

ANDB

V:Data Reg V:Bit Reg. P:Indir. (Data) P:Indir. (Bit)

2.8 µs 2.8 µs 29.6 µs 29.6 µs

2.8 µs 2.8 µs 29.6 µs 29.6 µs

ANDNB

V:Data Reg. V:Bit Reg. P:Indir. (Data) P:Indir. (Bit)

2.7 µs 2.7 µs 29.6 µs 29.6 µs

2.7 µs 2.7 µs 29.6 µs 29.6 µs

OUTB

V:Data Reg. V:Bit Reg. P:Indir. (Data) P:Indir. (Bit)

3.1 µs 3.1 µs 30.3 µs 30.3 µs

3.4 µs 3.4 µs 30.7 µs 30.7 µs

SETB

V:Data Reg. V:Bit Reg. P:Indir. (Data) P:Indir. (Bit)

13.4 µs 13.4 µs 41.1 µs 41.1 µs

3.4 µs 3.4 µs 29.1 µs 29.1 µs

RSTB

V:Data Reg. V:Bit Reg. P:Indir. (Data) P:Indir. (Bit)

13.5 µs 13.5 µs 41.3 µs 41.3 µs

1.4 µs 1.4 µs 29.1 µs 29.1 µs

DL06 Micro PLC User Manual, 3rd Edition Rev. A

Page 233

Appendix C: Instruction Execution Times

Timer, Counter and Shift Register Timer, Counter and Shift Register Instruction

1st

Legal Data Types 2nd

DL06 Execute

Not Execute

TMR

T

V Data Reg. V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)

26.8 µs 26.8 µs 20.0 µs 45.6 µs 45.6 µs

7.3 µs 7.3 µs 4.8 µs 30.2 µs 30.2 µs

TMRF

T

V:Data Reg. V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)

51.4 µs 51.4 µs 48.4 µs 75.9 µs 75.9 µs

7.3 µs 7.3 µs 4.6 µs 30.2 µs 30.2 µs

TMRA

T

V:Data Reg. V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)

48.9 µs 48.9 µs 45.0 µs 75.9 µs 75.9 µs

7.3 µs 7.3 µs 4.6 µs 30.2 µs 30.2 µs

1st

2nd V Data Reg. V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)

54.2 µs 54.2 µs 50.3 µs 81.2 µs 81.2 µs

7.3 µs 7.3 µs 4.6 µs 30.2 µs 30.2 µs

TMRAF

T

CNT

CT

V:Data Reg. V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)

25.8 µs 25.8 µs 22.2 µs 53.5 µs 53.5 µs

7.3 µs 7.3 µs 4.6 µs 30.2 µs 30.2 µs

SGCNT

CT

V:Data Reg. V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)

27.3 µs 27.3 µs 23.5 µs 54.9 µs 54.9 µs

7.3 µs 7.3 µs 4.6 µs 30.2 µs 30.2 µs

UDC

CT

V:Data Reg V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit)

39.8 µs 39.8 µs 35.4 µs 67.8 µs 67.8 µs

7.3 µs 7.3 µs 4.6 µs 30.2 µs 30.2 µs

SR

C (N points to shift)

17.8 µs + 0.9 µs x N

9.8 µs

DL06 Micro PLC User Manual, 3rd Edition Rev. A

1 2 C 4 5 6 7 8 9 10 11 12 13 14 A B C D C–13

Page 234

Appendix C: Instruction Execution Times

Accumulator Data Instructions

1 2 C 4 5 6 7 8 9 10 11 12 13 14 A B C D

Accumulator / Stack Load and Output Data Instructions Instruction

Legal Data Types

DL06 Execute

Not Execute

LD

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)

11.8 µs 11.8µs 9.0 µs 33.9 µs 33.9 µs

1.0 µs 1.0 µs 1.0 µs 0.9 µs 0.9 µs

LDD

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)

12.2 µs 12.2 µs 9.0 µs 37.8 µs 37.8 µs

1.0 µs 1.0 µs 1.0 µs 0.9 µs 0.9 µs

LDF

1st X, Y, C, S T, CT, SP

20.5 µs+0.9 µsxN

0.9 µs

10.4 µs

1.0 µs

LDR

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)

29.5 µs 29.5 µs 25.5 µs 54.9 µs 54.9 µs

1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs

LDSX

K: Constant

14.6 µs

1.0 µs

LDX

V:Data Reg. V:Bit Reg. P:Indir. (Data) P:Indir. (Bit)

10.8 µs 10.8 µs 45.2 µs 45.2 µs

1.0 µs 1.0 µs 1.0 µs 1.0 µs

OUT

V:Data Reg. V:Bit Reg. P:Indir. (Data) P:Indir. (Bit)

9.3 µs 9.3 µs 35.2 µs 35.2 µs

1.0 µs 1.0 µs 0.9 µs 0.9 µs

OUTD

V:Data Reg. V:Bit Reg. P:Indir. (Data) P:Indir. (Bit)

10.2 µs 10.2 µs 35.8 µs 35.8 µs

1.0 µs 1.0 µs 0.9 µs 0.9 µs

OUTF

1st X, Y, C

54 µs+1.0 µsxN

0.9 µs

OUTL

V:Data Reg. V:Bit Reg.

13.5 µs 13.5 µs

1.0 µs 1.0 µs

OUTM

V:Data Reg. V:Bit Reg.

13.7 µs 13.7 µs

1.0 µs 1.0 µs

OUTX

V:Data Reg. V:Bit Reg. P:Indir. (Data) P:Indir. (Bit)

17.2 µs 17.2 µs 43.4 µs 43.4 µs

1.0 µs 1.0 µs 1.0 µs 1.0 µs

NONE

8.4 µs

1.0 µs

LDA

C–14

2nd K:Constant O: (Octal constant for address)

POP

2nd K:Constant

DL06 Micro PLC User Manual, 3rd Edition Rev. A

Page 235

Appendix C: Instruction Execution Times

Logical Instructions Logical (Accumulator) nstructions Instruction AND

ANDD

ANDF ANDS OR

ORD

ORF ORS XOR

XORD

XORF XORS CMP

CMPD

Legal Data Types V:Data Reg. V:Bit Reg. P:Indir. (Data) P:Indir. (Bit) V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit) 1st: X, Y, C, S T, CT, SP, GX, GY 2nd: K:Constant None V:Data Reg V:Bit Reg. P:Indir. (Data) P:Indir. (Bit) V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit) 1st: X, Y, C, S T, CT, SP, GX, GY 2nd: K:Constant

DL06 Execute

Not Execute

7.9 µs 7.9 µs 33.4 µs 33.4 µs 8.9 µs 8.9 µs 5.7 µs 34.4 µs 34.4 µs

1.0 µs 1.0 µs 0.9 µs 0.9 µs 1.0 µs 1.0 µs 1.0 µs 0.9 µs 0.9 µs

21.6 µs + 0.9 µs x N

1.0 µs

10.0 µs 8.1 µs 8.1 µs 33.8 µs 33.8 µs 9.0 µs 9.0 µs 5.8 µs 34.5 µs 34.5 µs

1.0 µs 1.0 µs 1.0 µs 0.9 µs 0.9 µs 1.0 µs 1.0 µs 1.0 µs 0.9 µs 0.9 µs

20.9 µs + 0.9 µs x N

1.0 µs

None V:Data Reg. V:Bit Reg. P:Indir. (Data) P:Indir. (Bit) V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit) 1st: X, Y, C, S T, CT, SP, GX, GY 2nd: K:Constant

10.2 µs 8.0 µs 8.0 µs 33.6 µs 33.6 µs 9.0 µs 9.0 µs 5.4 µs 34.4 µs 34.4 µs

1.0 µs 1.0 µs 1.0 µs 0.9 µs 0.9 µs 1.0 µs 1.0 µs 1.0 µs 0.9 µs 0.9 µs

20.9 µs + 0.9 µs x N

1.0 µs

None V:Data Reg. V:Bit Reg. P:Indir. (Data) P:Indir. (Bit) V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)

10.1 µs 9.4 µs 9.4 µs 34.9 µs 34.9 µs 9.9 µs 9.9 µs 6.7 µs 35.4 µs 35.4 µs

1.0 µs 1.0 µs 1.0 µs 0.9 µs 0.9 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs

DL06 Micro PLC User Manual, 3rd Edition Rev. A

1 2 C 4 5 6 7 8 9 10 11 12 13 14 A B C D C–15

Page 236

Appendix C: Instruction Execution Times

Logical Instructions (cont’d)

1 2 C 4 5 6 7 8 9 10 11 12 13 14 A B C D

Logical (Accumulator) Instructions Instruction CMPF

CMPR CMPS

Legal Data Types 1st: X, Y, C, S T, CT, SP, GX, GY 2nd: K:Constant V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit) None

DL06 Execute

Not Execute

20.9 µs + 1.0 µs x N

1.0 µs

42.8 µs 42.8 µs 38.4 µs 69.0 µs 69.0 µs 11.2 µs

1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs

Math Instructions

C–16

Math Instructions (Accumulator) Instruction

DL06

Legal Data Types

Execute

Not Execute

V:Data Reg. V:Bit Reg. P:Indir. (Data) P:Indir. (Bit) V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Daa) P:Indir. (Bit)

78.4 µs 78.4 µs 101.2 µs 101.2 µs 83.3 µs 83.3 µs 67.7 µs 101.2 µs 101.2 µs

0.9 µs 0.9 µs 0.9 µs 0.9 µs 0.9 µs 0.9 µs 0.9 µs 0.9 µs 0.9 µs

SUB

V:Data Reg. V:Bit Reg P:Indir. (Data) P:Indir. (Bit)

77.4 µs 77.4 µs 95.1 µs 95.1 µs

0.9 µs 0.9 µs 0.9 µs 0.9 µs

SUBD

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)

82.5 µs 82.5 µs 66.0 µs 99.7 µs 99.7 µs

0.9 µs 0.9 µs 0.9 µs 0.9 µs 0.9 µs

MUL

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)

266.1 µs 266.1 µs 286.9 µs 290.0 µs 290.0 µs

0.9 µs 0.9 µs 0.9 µs 0.9 µs 0.9 µs

MULD

V:Data Reg. V:Bit Reg. P:Indir. (Data) P:Indir. (Bit)

839.1 µs 839.1 µs 863.1 µs 863.1 µs

0.9 µs 0.9 µs 0.9 µs 0.9 µs

V:Data Reg. V:Bit Reg K:Constant P:Indir. (Data) P:Indir. (Bit) V:Data Reg. V:Bit Reg. P:Indir. (Data) P:Indir. (Bit)

363.9 µs 363.9 µs 384.4 µs 419.8 µs 419.8 µs 398.3 µs 398.3 µs 390.9 µs 390.9 µs

0.9 µs 0.9 µs 0.9 µs 0.9 µs 0.9 µs 0.9 µs 0.9 µs 0.9 µs 0.9 µs

ADD

ADDD

DIV

DIVD

DL06 Micro PLC User Manual, 3rd Edition Rev. A

Page 237

Appendix C: Instruction Execution Times

Math Instructions (cont’d) Math Instructions (Accumulator) Instruction

DL06

Legal Data Types

Execute

Not Execute

INC

V:Data Reg V:Bit Reg P:Indir. (Data) P:Indir. (Bit)

48.5 µs 48.5 µs 74.7 µs 74.7 µs

1.0 µs 1.0 µs 1.0 µs 1.0 µs

DEC

V:Data Reg. V:Bit Reg. P:Indir. (Data ) P:Indir. (Bit)

47.5 µs 47.5 µs 71.5 µs 71.5 µs

1.0 µs 1.0 µs 1.0 µs 1.0 µs

INCB

V:Data Reg. V:Bit Reg. P:Indir. (Data) P:Indir. (Bit)

13.2 µs 13.2 µs 38.6 µs 38.6 µs

1.0 µs 1.0 µs 0.9 µs 0.9 µs

DECB

V:Data Reg. V:Bit Reg. P:Indir. (Data) P:Indir. (Bit)

13.2 µs 13.2 µs 38.0 µs 38.0 µs

1.0 µs 1.0 µs 0.9 µs 0.9 µs

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit) V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit) V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit) V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit) V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit) V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit) V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit)

24.9 µs 24.9 µs 23.5 µs 51.1 µs 51.1 µs 24.4 µs 24.4 µs 20.7 µs 50.7 µs 50.7 µs 24.7 µs 24.7 µs 23.3 µs 50.6 µs 50.6 µs 24.2 µs 24.2 µs 20.2 µs 50.2 µs 50.2 µs 10.8 µs 10.8 µs 8.2 µs 37.1 µs 37.1 µs 28.7 µs 28.7 µs 26.1 µs 54.9 µs 54.9 µs 48.1 µs 48.1 µs 41.7 µs 74.3 µs 74.3 µs

1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs

ADDB

ADDBD

SUBB

SUBBD

MULB

DIVB

ADDR

DL06 Micro PLC User Manual, 3rd Edition Rev. A

1 2 C 4 5 6 7 8 9 10 11 12 13 14 A B C D C–17

Page 238

Appendix C: Instruction Execution Times

Math Instructions (cont’d)

1 2 C 4 5 6 7 8 9 10 11 12 13 14 A B C D C–18

Math Instructions (Accumulator) Instruction SUBR

MULR

DIVR

ADDF SUBF MULF DIVF ADDS SUBS MULS DIVS ADDBS SUBBS MULBS DIVBS SQRTR SINR COSR TANR ASINR ACOSR ATANR

DL06

Legal Data Types

Execute

Not Execute

V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit) V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit) V:Data Reg. V:Bit Reg. K:Constant P:Indir. (Data) P:Indir. (Bit) 1st: X, Y, C, S T, CT, SP, GX, GY 2nd: K:Constant 1st: X, Y, C, S T, CT, SP, GX, GY 2nd: K:Constant 1st: X, Y, C, S T, CT, SP, GX, GY 2nd: K:Constant 1st: X, Y, C, S T, CT, SP, GX, GY 2nd: K:Constant None None None None None None None None None None None None None None None

50.1 µs 50.1 µs 58.7 µs 76.3 µs 76.3 µs 54.2 µs 54.2 µs 42.7 µs 80.4 µs 80.4 µs 50.1 µs 50.1 µs 58.7 µs 76.3 µs 76.3 µs

1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs

109.3 µs + 0.9 µs x N

1.0 µs

107.3 µs + 0.9 µs x N

1.0 µs

352.5 µs + 0.9 µs x N

1.0 µs

477.3 µs + 0.8 µs x N

1.0 µs

99.5 µs 97.5 µs 342.5 µs 467.3 µs 24.3 µs 23.7 µs 11.7 µs 29.7 µs 87.9 µs 226.8 µs 213.1 µs 285.5 µs 489.8 µs 508.3 µs 317.1 µs

1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs

DL06 Micro PLC User Manual, 3rd Edition Rev. A

Page 239

Appendix C: Instruction Execution Times

Differential Instructions Differential Instructions Instruction PD STRPD STRND ORPD ORND ANDPD ANDND

DL06

Legal Data Types

Execute

Not Execute

X, Y, C X, Y, C, S, T, CT X, Y, C, S, T, CT X, Y, C, S, T, CT X, Y, C, S, T, CT X, Y, C, S, T, CT X, Y, C, S, T, CT

14.4 µs 5.4 µs 7.3 µs 6.8 µs 7.1 µs 6.8 µs 7.1 µs

14.4 µs 5.4 µs 7.3 µs 5.2 µs 4.9 µs 5.2 µs 4.9 µs

Bit Instructions Bit Instructions (Accumulator) Instruction

DL06

Legal Data Types

Execute

Not Execute

SUM

None

1.0 µs

SHFR

V:Data Reg. (N bits) V:Bit Reg. (N bits) K:Constant (N bits)

6.7 µs 12.1 µs + 0.1 x N

SHFL

ROTR ROTL ENCO DECO

V:Data Reg. (N bits) V:Bit Reg. (N bits) K:Constant (N bits) V:Data Reg. (N bits) V:Bit Reg. (N bits) K:Constant (N bits) V:Data Reg. (N bits) V:Bit Reg. (N bits) K:Constant (N bits) None None

0.9 µs 8.4 µs + 0.1 x N 12.1 µs + 0.1 x N 0.9 µs 8.4 µs + 0.1 x N 16.4 µs 16.4 µs 12.9 µs 16.4 µs 16.4 µs 12.7 µs 33.9 µs 5.7 µs

1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 1.0 µs 0.9 µs 1.0 µs

DL06 Micro PLC User Manual, 3rd Edition Rev. A

1 2 C 4 5 6 7 8 9 10 11 12 13 14 A B C D C–19