Page 1
GS2 Series Drives User Manual
115V Input: 0.25 - 1.0 hp 230V Input: 0.5 - 7.5 hp 460V Input: 1.0 - 10 hp 575V Input: 1.0 - 10 hp
Page 2
Page 3
WARNING Thank you for purchasing automation equipment from Automationdirect.com®, doing business as AutomationDirect. We want your new automation equipment to operate safely. Anyone who installs or uses this equipment should read this publication (and any other relevant publications) before installing or operating the equipment. To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. These codes vary from area to area and usually change with time. It is your responsibility to determine which codes should be followed, and to verify that the equipment, installation, and operation is in compliance with the latest revision of these codes. At a minimum, you should follow all applicable sections of the National Fire Code, National Electrical Code, and the codes of the National Electrical Manufacturer's Association (NEMA). There may be local regulatory or government offices that can also help determine which codes and standards are necessary for safe installation and operation. Equipment damage or serious injury to personnel can result from the failure to follow all applicable codes and standards. We do not guarantee the products described in this publication are suitable for your particular application, nor do we assume any responsibility for your product design, installation, or operation. Our products are not fault-tolerant and are not designed, manufactured or intended for use or resale as on-line control equipment in hazardous environments requiring fail-safe performance, such as in the operation of nuclear facilities, aircraft navigation or communication systems, air traffic control, direct life support machines, or weapons systems, in which the failure of the product could lead directly to death, personal injury, or severe physical or environmental damage ("High Risk Activities"). AutomationDirect specifically disclaims any expressed or implied warranty of fitness for High Risk Activities. For additional warranty and safety information, see the Terms and Conditions section of our catalog. If you have any questions concerning the installation or operation of this equipment, or if you need additional information, please call us at 770-844-4200. This publication is based on information that was available at the time it was printed. At AutomationDirect we constantly strive to improve our products and services, so we reserve the right to make changes to the products and/or publications at any time without notice and without any obligation. This publication may also discuss features that may not be available in certain revisions of the product.
Trademarks This publication may contain references to products produced and/or offered by other companies. The product and company names may be trademarked and are the sole property of their respective owners. AutomationDirect disclaims any proprietary interest in the marks and names of others. Copyright 2004, Automationdirect.com® Incorporated All Rights Reserved No part of this manual shall be copied, reproduced, or transmitted in any way without the prior, written consent of Automationdirect.com® Incorporated. AutomationDirect retains the exclusive rights to all information included in this document.
Page 4
AVERTISSEMENT Nous vous remercions d'avoir acheté l'équipement d'automatisation de Automationdirect.com®, en faisant des affaires comme AutomationDirect. Nous tenons à ce que votre nouvel équipement d'automatisation fonctionne en toute sécurité. Toute personne qui installe ou utilise cet équipement doit lire la présente publication (et toutes les autres publications pertinentes) avant de l'installer ou de l'utiliser. Afin de réduire au minimum le risque d'éventuels problèmes de sécurité, vous devez respecter tous les codes locaux et nationaux applicables régissant l'installation et le fonctionnement de votre équipement. Ces codes diffèrent d'une région à l'autre et, habituellement, évoluent au fil du temps. Il vous incombe de déterminer les codes à respecter et de vous assurer que l'équipement, l'installation et le fonctionnement sont conformes aux exigences de la version la plus récente de ces codes. Vous devez, à tout le moins, respecter toutes les sections applicables du Code national de prévention des incendies, du Code national de l'électricité et des codes de la National Electrical Manufacturer's Association (NEMA). Des organismes de réglementation ou des services gouvernementaux locaux peuvent également vous aider à déterminer les codes ainsi que les normes à respecter pour assurer une installation et un fonctionnement sûrs. L'omission de respecter la totalité des codes et des normes applicables peut entraîner des dommages à l'équipement ou causer de graves blessures au personnel. Nous ne garantissons pas que les produits décrits dans cette publication conviennent à votre application particulière et nous n'assumons aucune responsabilité à l'égard de la conception, de l'installation ou du fonctionnement de votre produit. Nos produits ne sont pas insensibles aux défaillances et ne sont ni conçus ni fabriqués pour l'utilisation ou la revente en tant qu'équipement de commande en ligne dans des environnements dangereux nécessitant une sécurité absolue, par exemple, l'exploitation d'installations nucléaires, les systèmes de navigation aérienne ou de communication, le contrôle de la circulation aérienne, les équipements de survie ou les systèmes d'armes, pour lesquels la défaillance du produit peut provoquer la mort, des blessures corporelles ou de graves dommages matériels ou environnementaux («activités à risque élevé»). La société AutomationDirect nie toute garantie expresse ou implicite d'aptitude à l'emploi en ce qui a trait aux activités à risque élevé. Pour des renseignements additionnels touchant la garantie et la sécurité, veuillez consulter la section Modalités et conditions de notre documentation. Si vous avez des questions au sujet de l'installation ou du fonctionnement de cet équipement, ou encore si vous avez besoin de renseignements supplémentaires, n'hésitez pas à nous téléphoner au 770-844-4200. Cette publication s'appuie sur l'information qui était disponible au moment de l'impression. À la société AutomationDirect, nous nous efforçons constamment d'améliorer nos produits et services. C'est pourquoi nous nous réservons le droit d'apporter des modifications aux produits ou aux publications en tout temps, sans préavis ni quelque obligation que ce soit. La présente publication peut aussi porter sur des caractéristiques susceptibles de ne pas être offertes dans certaines versions révisées du produit.
Marques de commerce La présente publication peut contenir des références à des produits fabriqués ou offerts par d'autres entreprises. Les désignations des produits et des entreprises peuvent être des marques de commerce et appartiennent exclusivement à leurs propriétaires respectifs. AutomationDirect nie tout intérêt dans les autres marques et désignations. Copyright 2004, Automationdirect.com® Incorporated Tous droits réservés Nulle partie de ce manuel ne doit être copiée, reproduite ou transmise de quelque façon que ce soit sans le consentement préalable écrit de la société Automationdirect.com® Incorporated. AutomationDirect conserve les droits exclusifs à l'égard de tous les renseignements contenus dans le présent document.
Page 5
WARNING Warning: Read this manual thoroughly before using GS2 Series AC Motor Drives.
WARNING: AC input power must be disconnected before performing any maintenance. Do not connect or disconnect wires or connectors while power is applied to the circuit. Maintenance must be performed only by a qualified technician. WARNING: There are highly sensitive MOS components on the printed circuit boards, and these components are especially sensitive to static electricity. To avoid damage to these components, do not touch these components or the circuit boards with metal objects or your bare hands. WARNING: A charge may still remain in the DC-link capacitor with hazardous voltages, even if the power has been turned off. To avoid personal injury, do not remove the cover of the AC drive until all "DISPLAY LED" lights on the digital keypad are off. Please note that there are live components exposed within the AC drive. Do not touch these live parts. WARNING: Ground the GS2 AC Drive using the ground terminal. The grounding method must comply with the laws of the country where the AC drive is to be installed. Refer to “Basic Wiring Diagram” in CHAPTER 2. WARNING: The mounting enclosure of the AC drive must comply with EN50178. Live parts shall be arranged in enclosures or located behind barriers that meet at least the requirements of the Protective Type IP20. The top surface of the enclosures or barrier that is easily accessible shall meet at least the requirements of the Protective Type IP40. Users must provide this environment for GS2 Series AC Drive. Warning: The AC drive may be destroyed beyond repair if incorrect cables are connected to the input/output terminals. Never connect the AC drive output terminals T1, T2, and T3 directly to the AC main circuit power supply.
Page 6
GS2 SERIES AC DRIVE USER MANUAL Please include the Manual Number and the Manual Issue, both shown below, when communicating with Technical Support regarding this publication.
Manual Number:
GS2-M
Issue:
First Edition, Revision C
Issue Date:
12/2006 Publication History
Issue
Date
Description of Changes
First Edition
6/07/02
Original
First Edition, Revision A
6/30/03
Made minor changes throughout. Update for Firmware Version 1.04 Added parameter 7.00 (PID) functionality.
First Edition, Revision B
1/28/05
Added 115V drives; Made minor changes throughout.
Added 575V drives and accessories; Added Ch1 Drives Purpose section; Added short circuit withstand specifications and notes; First Edition, Revision C 12/2006 Changed Ch5 DL PLC control program example; Added new AppxB PLC analog modules; Miscellaneous clarification revisions throughout.
Page 7
TABLE OF CONTENTS
Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–1 Manual Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–2 GS2 AC Drive Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–3 GS2 AC Drive Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–5
Installation and Wiring . . . . . . . . . . . . . . . . . . . . . . .2–1 Ambient Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2–2 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2–3 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2–4 GS2 Circuit Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2–6 External Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2–12
Keypad Operation and Quickstart . . . . . . . . . . . . . . .3–1 The GS2 Digital Keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3–2 GS2 Quickstart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3–6
AC Drive Parameters . . . . . . . . . . . . . . . . . . . . . . . . .4–1 GS2 Parameter Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4–2 Detailed Parameter Listings . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4–11 Motor Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4–11 Ramp Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4–13 Volts/Hertz Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4–19 Digital Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4–22 Analog Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4–32 Preset Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4–41 Protection Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4–43 PID Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4–51 Display Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4–55 Communication Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . .4–56
Page 8
Table of Contents
GS2 Modbus Communications . . . . . . . . . . . . . . . . .5–1 Communication Parameters Summary . . . . . . . . . . . . . . . . . . . . .5–2 GS2 Parameter Memory Addresses . . . . . . . . . . . . . . . . . . . . . . . .5–4 GS2 Status Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5–9 Communicating with DirectLogic PLCs . . . . . . . . . . . . . . . . . . . .5–12 Communicating with Third-party Devices . . . . . . . . . . . . . . . . . .5–30
Maintenance and Troubleshooting . . . . . . . . . . . . . .6–1 Maintenance and Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6–2 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6–3
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A–1 Accessories Part Numbering . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A–2 Line Reactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A–2 Braking Resistors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A–8 EMI Input Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A–10 RF Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A–16 Fuses and Fuse Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A–17 GS-EDRV Ethernet Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . .A–20 GS Drive Configuration Software . . . . . . . . . . . . . . . . . . . . . . . .A–22 Miscellaneous Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A–25
Using GS2 AC Drives with DirectLOGIC PLCs . . . . . .B–1 Compatible DirectLOGIC PLCs and Modules . . . . . . . . . . . . . . . . .B–2 Typical Connections to the GS2 Series AC Drive . . . . . . . . . . . . . .B–7
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .I–1 ii
GS2 Series AC Drive User Manual
Page 9
GETTING STARTED
CHAPTER
1
In This Chapter... Manual Overview . . . . . . . . . . . . . . . . . . . . . . . . . .1–2 Overview of this Publication . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–2 Who Should Read This Manual . . . . . . . . . . . . . . . . . . . . . . . . . .1–2 Supplemental Publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–2 Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–2 Special Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–2
GS2 AC Drive Introduction . . . . . . . . . . . . . . . . . .1–3 Purpose of AC Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–3 Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–3 Model Explanation: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–3 Nameplate Information: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–3 External Parts and Labels: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–4
GS2 AC Drive Specifications . . . . . . . . . . . . . . . . . .1–5
Page 10
Chapter 1: Getting Started
Manual Overview Overview of this Publication The GS2 AC Drive User Manual describes the installation, configuration, and methods of operation of the GS2 Series AC Drive.
Who Should Read This Manual This manual contains important information for those who will install, maintain, and/or operate any of the GS2 Series AC Drives.
Supplemental Publications The National Electrical Manufacturers Association (NEMA) publishes many different documents that discuss standards for industrial control equipment. Global Engineering Documents handles the sale of NEMA documents. For more information, you can contact Global Engineering Documents at: 15 Inverness Way East Englewood, CO 80112-5776 1-800-854-7179 (within the U.S.) 303-397-7956 (international) www.global.ihs.com NEMA documents that might assist with your AC drive systems are: • Application Guide for AC Adjustable Speed Drive Systems • Safety Standards for Construction and Guide for Selection, Installation, and Operation of Adjustable Speed Drive Systems.
Technical Support By Telephone: 770-844-4200 (Mon.-Fri., 9:00 a.m.-6:00 p.m. E.T.)
On the Web: www.automationdirect.com
Our technical support group is glad to work with you in answering your questions. If you cannot find the solution to your particular application, or, if for any reason you need additional technical assistance, please call technical support at 770-844-4200. We are available weekdays from 9:00 a.m. to 6:00 p.m. Eastern Time. We also encourage you to visit our web site where you can find technical and non-technical information about our products and our company. Visit us at www.automationdirect.com.
Special Symbols When you see the “notepad” icon in the left-hand margin, the paragraph to its immediate right will be a special note. When you see the “exclamation mark” icon in the left-hand margin, the paragraph to its immediate right will be a WARNING. This information could prevent injury, loss of property, or even death (in extreme cases).
1–2
GS2 Series AC Drive User Manual