Page 161
Appendix A: Accessories
EMI Filter Connections
1-phase Input Power
L
R
N
EMI Input Filter L
N
S
T
EMI Input Filter R
S
T
L1 L2 L3
L1 L2
1st Ed. Rev. C
3-phase Input Power
12/2006
GS2 Series AC Drive User Manual
A–15
Page 162
Appendix A: Accessories
RF Filters Description Zero phase reactors, (aka RF noise filters) help reduce radiated noise from the AC drive power wiring. These RF filters are effective for noise reduction on both the input and output sides of AC drives. Attenuation quality is good in a wide range from AM band to 10 MHz. Wiring Method Wind each wire four times around the core, as shown in Figure 1. The reactor should me mounted as closely as possible to the drive. If you are unable to wire as described above due to wire size or another aspects of your application, put all wires through four reactor cores in series without winding, as shown in Figure 2.
36 (1.42)
RF Filter number RF220X00A can be used with all models of GS2 AC drives.
35 (1.38)
68.5 (2.70)
RF220X00A
25 (0.98)
90 (3.54) 80 (3.15)
UNITS: mm (in) TOP VIEW
Figure 1 Line Power
L1
T1
L2
T2
L3
T3
MOTOR
Figure 2 Line Power
A–16
L1 L2 L3
T1 T2 T3
GS2 Series AC Drive User Manual
MOTOR
Page 163
Appendix A: Accessories
Fuses and Fuse Kits Short-circuit and ground fault protection devices are essential to prevent costly damage to your AC Drive application equipment. Fuse kits are available from AutomationDirect for the 115V through 460V GS2 Series AC Drives. Warning: The fuse kits provide protection only for the semiconductor components inside the AC drive. Motor branch circuit overcurrent protection should be separately provided using applicable local codes.
The following fuse kits consist of one fuse block and fuses sized to match each GS2 Series AC Drive. Replacement fuses are also available, and their part numbers are listed in the table below.
Fuse Kit Specifications (for 115V, 230V, 460V GS2 drive models) Part Number
Drive Model Fuse Wire Fuse Dimen / Phase Block Size Type -sions
GS-10P2-FKIT-1P GS-10P5-FKIT-1P GS-11P0-FKIT-1P GS-20P5-FKIT-1P GS-20P5-FKIT-3P GS-21P0-FKIT-1P GS-21P0-FKIT-3P GS-22P0-FKIT-1P GS-22P0-FKIT-3P GS-23P0-FKIT-1P GS-23P0-FKIT-3P GS-25P0-FKIT
GS2-10P2 / 1 GS2-10P5 / 1
2 pole
Figure 1 300V@20A
GS2-20P5 / 3
3 pole
Figure 2 300V@10A
GS2-21P0 / 1
Figure 1 300V@30A
GS2-21P0 / 3
2 pole Al/Cu 3 pole #2-14
GS2-22P0 / 1
2 pole
Figure 1 300V@45A
GS2-22P0 / 3
3 pole
Figure 2 300V@25A
GS2-23P0 / 1
2 pole
Figure 1 300V@60A
GS2-11P0 / 1 GS2-20P5 / 1
GS-41P0-FKIT GS-42P0-FKIT GS-43P0-FKIT GS-45P0-FKIT GS-47P5-FKIT
GS2-41P0 / 3
GS-4010-FKIT
GS2-4010 / 3
GS2-42P0 / 3 GS2-43P0 / 3
Figure 2 300V@20A
Figure 2
GS2-25P0 / 3 GS2-27P5 / 3
12/2006
A3T
GS2-23P0 / 3
GS-27P5-FKIT
1st Ed. Rev. C
Fuse Rating
Al/Cu 2/0-#6
Figure 3
300V@40A 300V@60A 300V @100A
Al/Cu #2-14
GS2-45P0 / 3 GS2-47P5 / 3
Figure 5 600V@50A Al/Cu 2/0-#6
Figure 6 600V@70A
GS-4010-FUSE
Figure 4 A6T
GS-27P5-FUSE GS-41P0-FUSE GS-42P0-FUSE GS-43P0-FUSE GS-45P0-FUSE GS-47P5-FUSE
600V@10A 3 pole
Replacement Fuses GS-10P2-FUSE-1P GS-10P5-FUSE-1P GS-11P0-FUSE-1P GS-20P5-FUSE-1P GS-20P5-FUSE-3P GS-21P0-FUSE-1P GS-21P0-FUSE-3P GS-22P0-FUSE-1P GS-22P0-FUSE-3P GS-23P0-FUSE-1P GS-23P0-FUSE-3P GS-25P0-FUSE
600V@15A 600V@20A 600V@30A
GS2 Series AC Drive User Manual
A–17
Page 164
Appendix A: Accessories
Fuses and Fuse Kits (continued) Edison Class CC fuses and fuse blocks are available for the 575V GS2 drives.
Fuses (for 575V GS2 drive models) Drive Model
Fuse Rating
GS2-51P0
6A @ 600V
GS2-52P0
10A @ 600V
GS2-53P0 GS2-55P0
Fuse Type (Qty Req’d)
15A @ 600V
GS2-57P5
20A @ 600V
GS2-5010
30A @ 600V
Edison Fuse HCLR6 HCLR10 HCLR15
CC (3)
HCLR20 HCLR30
Edison Dimensions Poles Fuse Block BC6033PQ or CHCC3D or CHCC3DI
Wire Range
Figure 7 Figure 8
3
18-8 AWG (1-16 mm2)
Figure 8
Fuses and Fuse Kits Dimensions Figure 1 [units = inches]
Figure 2 [units = inches]
Figure 3 [units = inches] Dia. 0.25 THRU C'BORE Dia. 0.50 x 0.50 DEEP (2 PLCS)
3.21"
3.65"
3.21"
3.65"
.73"
1.67"
1.67"
1.38”
.22"
.22"
2.75”
.49"
.49" .88"
.60"
1.47"
.60"
1.47"
.75"
2.73"
1.85"
A–18
1.750"
GS2 Series AC Drive User Manual
3.50" 5.00"
2.03”
Page 165
Appendix A: Accessories
Fuses and Fuse Kits Dimensions (continued) Figure 4 [units = inches]
Figure 5 [units = inches]
Figure 6 [units = inches]
.21" .28"
2.15"
.40"
1.95"
.671"
2.20"
.640"
1.56"
2.75" 4.38"
3.80" 4.60"
2.72"
Figure 7 [units = inches (mm)]
Figure 8 [units = mm (inches)] 0.425"
3 POLE
(10.80mm)
19.0 (0.75) 17.50 (0.689)
52.50 (2.067) 57.5 (2.26) 35.00 (1.378)
44.0 (1.73)
1.530"
1.625" + 0.015"
(38.86mm)
(41.28mm + 0.38mm)
80.7 (3.18)
45.2 (1.78)
0.200" + 0.003"
(5.08mm + 0.08mm)
Buss ®
BC6033PQ 1.210" + 0.015"
(30.73mm + 0.38mm)
30A
BUSSMANN COOPER INDUSTRIES ST. LOUIS, MO 63178 MADE IN U.S.A.
600V
CLASS CC FUSES ONLY CU ONLY 10 AWG 20 LB·IN
1st Ed. Rev. C
1.40"
4.78"
.24" 1.95"
1.57"
3.90"
3.13"
.79" 1.40"
12/2006
49.9 (1.97)
7.6 (0.30) 82.2 (3.24)
6.0 (0.24)
75 C WIRE 200,000A RMS SYM WITHSTAND RATING R
GS2 Series AC Drive User Manual
A–19
Page 166
Appendix A: Accessories
GS-EDRV Ethernet Interface The GS-EDRV Ethernet Interface provides a low-cost, high-performance Ethernet link between a PLC/PC-based Control system and any GS Series AC Drive. The GS-EDRV mounts on DIN rail and communicates through cable connections to the AC drive and Ethernet hub or PC. Functions and features of the interface: • process input signals from the AC drive • formats signals to conform to the Ethernet standard for connectivity to many control system architectures: H2-ERM or H4-ERM, KEPDirect EBC I/O server, or independent controller with a Modbus TCP/IP driver • transmit the signals to the PC-based controller • receive and translate output signals from the PLC/PC-based Control software • distribute the output signals to the appropriate drive • built-in web browser allows users to configure and control the drive from any web browser via the IP address of the GS-EDRV card.
The control function is not performed by the interface. The control function is performed by PC–based Control software (which is purchased separately) running on a PC. The GS-EDRV requires an external 24 VDC power supply.
The GS series drives have a provision for shutting down control or power to the drive in the event of a communications time-out. This function can be set up through the drive parameter group 9.
GS-EDRV Ethernet interface number GS-EDRV can be used with all models of GS2 AC drives.
A–20
Specifications Part Number GS-EDRV
Input Voltage
Input Current
10-33 VDC
90-135 mA
Can be used with all GS2 AC drives.
GS2 Series AC Drive User Manual
Page 167
Appendix A: Accessories
GS-EDRV Ethernet Interface (continued) GS-EDRV
Dimensions
2.7" 1.9"
4.0"
1st Ed. Rev. C
12/2006 units: inches
GS2 Series AC Drive User Manual
A–21
Page 168
Appendix A: Accessories
GS Drive Configuration Software GSoft is the optional configuration software for the GS family of AC drives. It allows you to connect a PC to a GS series AC drive via RS-232 or RS-485, and performs a variety of functions:
GS Series AC Drive Software Part Number Description GSOFT
GS drives configuration software
• Upload/download drive configurations • Create new drive configurations using Quick Start, Detailed, or Schematic Views • Edit drive configurations • Archive/store multiple drive configurations on your PC • Trend drive operation parameters • Tune the drive PID loop • View drive faults • Print a schematic representation of the drive configuration
System Requirements GSoft will run on PCs that meet the following requirements: • Windows 95, 98, Me, NT, 2000, and XP • Internet Explorer 4.0 or higher (for HTML help support) • 24Mb of available memory • 8 Mb hard drive space • Available RS-232 serial port Note: GSoft requires use of a configuration cable, GS-232CBL, which is sold separately. Note: RS-485 communication from an RS-232 PC port requires an FA-ISOCON or compatible converter, which is sold separately.
Software Configuration Methods GSoft offers 3 methods of creating a new configuration for your AC drive.
Quick Start Configuration The Quick Start Configuration method guides you through the most commonly used AC drive parameters. Quick Start Configuration may ONLY be used to create a new configuration. Once created and saved, a configuration built with the Quick Start Configuration method may be edited using the Detailed or Schematic View methods.
A–22
GS2 Series AC Drive User Manual
Page 169
Appendix A: Accessories
Software Configuration Methods (continued) Detailed Configuration The Detailed Configuration method provides AC drive parameter access in a tabbed dialog format. Detailed Configuration can be used for new or existing configurations.
1st Ed. Rev. C
12/2006
GS2 Series AC Drive User Manual
A–23
Page 170
Appendix A: Accessories
Software Configuration Methods (continued) Schematic View Configuration The Schematic View Configuration method uses a schematic picture of the AC drive and external connections to guide you through the setup of the AC drive. The Schematic View method can be used for new or existing configurations.
A–24
GS2 Series AC Drive User Manual