Page 161

Appendix A: Accessories

EMI Filter Connections

1-phase Input Power

L

R

N

EMI Input Filter L

N

S

T

EMI Input Filter R

S

T

L1 L2 L3

L1 L2

1st Ed. Rev. C

3-phase Input Power

12/2006

GS2 Series AC Drive User Manual

A–15

Page 162

Appendix A: Accessories

RF Filters Description Zero phase reactors, (aka RF noise filters) help reduce radiated noise from the AC drive power wiring. These RF filters are effective for noise reduction on both the input and output sides of AC drives. Attenuation quality is good in a wide range from AM band to 10 MHz. Wiring Method Wind each wire four times around the core, as shown in Figure 1. The reactor should me mounted as closely as possible to the drive. If you are unable to wire as described above due to wire size or another aspects of your application, put all wires through four reactor cores in series without winding, as shown in Figure 2.

36 (1.42)

RF Filter number RF220X00A can be used with all models of GS2 AC drives.

35 (1.38)

68.5 (2.70)

RF220X00A

25 (0.98)

90 (3.54) 80 (3.15)

UNITS: mm (in) TOP VIEW

Figure 1 Line Power

L1

T1

L2

T2

L3

T3

MOTOR

Figure 2 Line Power

A–16

L1 L2 L3

T1 T2 T3

GS2 Series AC Drive User Manual

MOTOR

Page 163

Appendix A: Accessories

Fuses and Fuse Kits Short-circuit and ground fault protection devices are essential to prevent costly damage to your AC Drive application equipment. Fuse kits are available from AutomationDirect for the 115V through 460V GS2 Series AC Drives. Warning: The fuse kits provide protection only for the semiconductor components inside the AC drive. Motor branch circuit overcurrent protection should be separately provided using applicable local codes.

The following fuse kits consist of one fuse block and fuses sized to match each GS2 Series AC Drive. Replacement fuses are also available, and their part numbers are listed in the table below.

Fuse Kit Specifications (for 115V, 230V, 460V GS2 drive models) Part Number

Drive Model Fuse Wire Fuse Dimen / Phase Block Size Type -sions

GS-10P2-FKIT-1P GS-10P5-FKIT-1P GS-11P0-FKIT-1P GS-20P5-FKIT-1P GS-20P5-FKIT-3P GS-21P0-FKIT-1P GS-21P0-FKIT-3P GS-22P0-FKIT-1P GS-22P0-FKIT-3P GS-23P0-FKIT-1P GS-23P0-FKIT-3P GS-25P0-FKIT

GS2-10P2 / 1 GS2-10P5 / 1

2 pole

Figure 1 300V@20A

GS2-20P5 / 3

3 pole

Figure 2 300V@10A

GS2-21P0 / 1

Figure 1 300V@30A

GS2-21P0 / 3

2 pole Al/Cu 3 pole #2-14

GS2-22P0 / 1

2 pole

Figure 1 300V@45A

GS2-22P0 / 3

3 pole

Figure 2 300V@25A

GS2-23P0 / 1

2 pole

Figure 1 300V@60A

GS2-11P0 / 1 GS2-20P5 / 1

GS-41P0-FKIT GS-42P0-FKIT GS-43P0-FKIT GS-45P0-FKIT GS-47P5-FKIT

GS2-41P0 / 3

GS-4010-FKIT

GS2-4010 / 3

GS2-42P0 / 3 GS2-43P0 / 3

Figure 2 300V@20A

Figure 2

GS2-25P0 / 3 GS2-27P5 / 3

12/2006

A3T

GS2-23P0 / 3

GS-27P5-FKIT

1st Ed. Rev. C

Fuse Rating

Al/Cu 2/0-#6

Figure 3

300V@40A 300V@60A 300V @100A

Al/Cu #2-14

GS2-45P0 / 3 GS2-47P5 / 3

Figure 5 600V@50A Al/Cu 2/0-#6

Figure 6 600V@70A

GS-4010-FUSE

Figure 4 A6T

GS-27P5-FUSE GS-41P0-FUSE GS-42P0-FUSE GS-43P0-FUSE GS-45P0-FUSE GS-47P5-FUSE

600V@10A 3 pole

Replacement Fuses GS-10P2-FUSE-1P GS-10P5-FUSE-1P GS-11P0-FUSE-1P GS-20P5-FUSE-1P GS-20P5-FUSE-3P GS-21P0-FUSE-1P GS-21P0-FUSE-3P GS-22P0-FUSE-1P GS-22P0-FUSE-3P GS-23P0-FUSE-1P GS-23P0-FUSE-3P GS-25P0-FUSE

600V@15A 600V@20A 600V@30A

GS2 Series AC Drive User Manual

A–17

Page 164

Appendix A: Accessories

Fuses and Fuse Kits (continued) Edison Class CC fuses and fuse blocks are available for the 575V GS2 drives.

Fuses (for 575V GS2 drive models) Drive Model

Fuse Rating

GS2-51P0

6A @ 600V

GS2-52P0

10A @ 600V

GS2-53P0 GS2-55P0

Fuse Type (Qty Req’d)

15A @ 600V

GS2-57P5

20A @ 600V

GS2-5010

30A @ 600V

Edison Fuse HCLR6 HCLR10 HCLR15

CC (3)

HCLR20 HCLR30

Edison Dimensions Poles Fuse Block BC6033PQ or CHCC3D or CHCC3DI

Wire Range

Figure 7 Figure 8

3

18-8 AWG (1-16 mm2)

Figure 8

Fuses and Fuse Kits Dimensions Figure 1 [units = inches]

Figure 2 [units = inches]

Figure 3 [units = inches] Dia. 0.25 THRU C'BORE Dia. 0.50 x 0.50 DEEP (2 PLCS)

3.21"

3.65"

3.21"

3.65"

.73"

1.67"

1.67"

1.38”

.22"

.22"

2.75”

.49"

.49" .88"

.60"

1.47"

.60"

1.47"

.75"

2.73"

1.85"

A–18

1.750"

GS2 Series AC Drive User Manual

3.50" 5.00"

2.03”

Page 165

Appendix A: Accessories

Fuses and Fuse Kits Dimensions (continued) Figure 4 [units = inches]

Figure 5 [units = inches]

Figure 6 [units = inches]

.21" .28"

2.15"

.40"

1.95"

.671"

2.20"

.640"

1.56"

2.75" 4.38"

3.80" 4.60"

2.72"

Figure 7 [units = inches (mm)]

Figure 8 [units = mm (inches)] 0.425"

3 POLE

(10.80mm)

19.0 (0.75) 17.50 (0.689)

52.50 (2.067) 57.5 (2.26) 35.00 (1.378)

44.0 (1.73)

1.530"

1.625" + 0.015"

(38.86mm)

(41.28mm + 0.38mm)

80.7 (3.18)

45.2 (1.78)

0.200" + 0.003"

(5.08mm + 0.08mm)

Buss ®

BC6033PQ 1.210" + 0.015"

(30.73mm + 0.38mm)

30A

BUSSMANN COOPER INDUSTRIES ST. LOUIS, MO 63178 MADE IN U.S.A.

600V

CLASS CC FUSES ONLY CU ONLY 10 AWG 20 LB·IN

1st Ed. Rev. C

1.40"

4.78"

.24" 1.95"

1.57"

3.90"

3.13"

.79" 1.40"

12/2006

49.9 (1.97)

7.6 (0.30) 82.2 (3.24)

6.0 (0.24)

75 C WIRE 200,000A RMS SYM WITHSTAND RATING R

GS2 Series AC Drive User Manual

A–19

Page 166

Appendix A: Accessories

GS-EDRV Ethernet Interface The GS-EDRV Ethernet Interface provides a low-cost, high-performance Ethernet link between a PLC/PC-based Control system and any GS Series AC Drive. The GS-EDRV mounts on DIN rail and communicates through cable connections to the AC drive and Ethernet hub or PC. Functions and features of the interface: • process input signals from the AC drive • formats signals to conform to the Ethernet standard for connectivity to many control system architectures: H2-ERM or H4-ERM, KEPDirect EBC I/O server, or independent controller with a Modbus TCP/IP driver • transmit the signals to the PC-based controller • receive and translate output signals from the PLC/PC-based Control software • distribute the output signals to the appropriate drive • built-in web browser allows users to configure and control the drive from any web browser via the IP address of the GS-EDRV card.

The control function is not performed by the interface. The control function is performed by PC–based Control software (which is purchased separately) running on a PC. The GS-EDRV requires an external 24 VDC power supply.

The GS series drives have a provision for shutting down control or power to the drive in the event of a communications time-out. This function can be set up through the drive parameter group 9.

GS-EDRV Ethernet interface number GS-EDRV can be used with all models of GS2 AC drives.

A–20

Specifications Part Number GS-EDRV

Input Voltage

Input Current

10-33 VDC

90-135 mA

Can be used with all GS2 AC drives.

GS2 Series AC Drive User Manual

Page 167

Appendix A: Accessories

GS-EDRV Ethernet Interface (continued) GS-EDRV

Dimensions

2.7" 1.9"

4.0"

1st Ed. Rev. C

12/2006 units: inches

GS2 Series AC Drive User Manual

A–21

Page 168

Appendix A: Accessories

GS Drive Configuration Software GSoft is the optional configuration software for the GS family of AC drives. It allows you to connect a PC to a GS series AC drive via RS-232 or RS-485, and performs a variety of functions:

GS Series AC Drive Software Part Number Description GSOFT

GS drives configuration software

• Upload/download drive configurations • Create new drive configurations using Quick Start, Detailed, or Schematic Views • Edit drive configurations • Archive/store multiple drive configurations on your PC • Trend drive operation parameters • Tune the drive PID loop • View drive faults • Print a schematic representation of the drive configuration

System Requirements GSoft will run on PCs that meet the following requirements: • Windows 95, 98, Me, NT, 2000, and XP • Internet Explorer 4.0 or higher (for HTML help support) • 24Mb of available memory • 8 Mb hard drive space • Available RS-232 serial port Note: GSoft requires use of a configuration cable, GS-232CBL, which is sold separately. Note: RS-485 communication from an RS-232 PC port requires an FA-ISOCON or compatible converter, which is sold separately.

Software Configuration Methods GSoft offers 3 methods of creating a new configuration for your AC drive.

Quick Start Configuration The Quick Start Configuration method guides you through the most commonly used AC drive parameters. Quick Start Configuration may ONLY be used to create a new configuration. Once created and saved, a configuration built with the Quick Start Configuration method may be edited using the Detailed or Schematic View methods.

A–22

GS2 Series AC Drive User Manual

Page 169

Appendix A: Accessories

Software Configuration Methods (continued) Detailed Configuration The Detailed Configuration method provides AC drive parameter access in a tabbed dialog format. Detailed Configuration can be used for new or existing configurations.

1st Ed. Rev. C

12/2006

GS2 Series AC Drive User Manual

A–23

Page 170

Appendix A: Accessories

Software Configuration Methods (continued) Schematic View Configuration The Schematic View Configuration method uses a schematic picture of the AC drive and external connections to guide you through the setup of the AC drive. The Schematic View method can be used for new or existing configurations.

A–24

GS2 Series AC Drive User Manual