Page 71
89 (3.5)
9.2 (0.36)
Rev C
Relay Form A (SPST) normally open
Commons Per Module
4 , 4 pts. / common (isolated)
Operating Voltage Range
6–240 VAC, 6–27 VDC
Output Voltage Range
5–264 VAC (47–63Hz) min. / max. 5–30 VDC min. / max.
Max. Load Current
2A / pt., 6A /common(subject to derating)
Max. Leakage Current
0.1mA @ 264 VAC
Max. Inrush Current
6A for 10ms / pt.; 20A for 10ms / com
Min. Load
5mA @ 5VDC
OFF to ON Response
< 15ms
ON to OFF Response
< 10ms
Base Power Required
700mA @ 5VDC
Status Indicators
Logic Side
Error Status Indications (LEDS)
FU1/ FU2 ON = fuse 1 or 2 blown FU3/ FU4 ON = fuse 3 or 4 blown
Fuses (User Replaceable) T1K–FUSE–2
4, (10A, 250V / common), (4 pts. / fuse) 5 x 20 mm type
Weight
200g
Output Points TR Fuses located under top cover
0 1 2 3 4 5 6 7 8 9 1011 12 13 1415 L
L L L L L L L
COM 0
COM 1
V0
V1
FU3
FU2
FU4
L L L L L L L L
COM 2
COM 3
Commons
6-27VDC 6-240VAC
FU1
54.3(2.14)
16
Output Type
6-27VDC 6-240VAC
V2
V3
8.1 (0.32)
V0 – V3 not used with Relay Output Modules mm (in.) 83.3 (3.28)
Equivalent Output Circuit Environmental Specifications Ambient Operating Temperature
32_F to 131_F (0_C to 55_C)
Storage Temperature
–4_F to 158_F (–20_C to 70_C)
Ambient Humidity
5% to 95% (Non–condensing)
Atmosphere
No corrosive gases. The level of environmental pollution = 2 (UL 840)
Vibration Resistance
MIL STD 810C, Method 514.2
Shock Resistance
MIL STD 810C, Method 516.2
Voltage Withstand
1500VAC, 1 minute
Insulation Resistance
500VDC, 10M ohm
Noise Immunity
NEMA ICS3–304
Internal Module Circuitry +V
Output
L To LED 10A
AC or DC Supply
Side View
COM 6-27VDC 6-240VAC
Impulse Noise 1us, 1000V
Date Code: 012* and later
FCC class A RFI (144MHz, 430MHz 10W, 10cm) Agency Approvals
UL, CE, FCC class A
80 (3.15)
Outputs Per Module
8.1 (0.32)
25.7(1.01)
T1K–16TR Relay Output
3–44
Wiring & Dimensions
Specifications
Derating Chart
Typical Relay Life (Operations) at Room Temperature Voltage & Type of Load
Load Current
Points 16
1A
2A
24 VDC Resistive
500K
250K
24 VDC Solenoid
100K
50K
110 VAC Resistive
500K
250K
110 VAC Solenoid
200K
100K
4
220 VAC Resistive
350K
200K
0
220 VAC Solenoid
100K
50K
1.0A 1.5A
12 2.0A
8
0 32
10 20 30 40 50 55 °C 50 68 86 104 122 131 ° F Ambient Temperature (°C/°F)
Page 72
Specifications
Wiring & Dimensions
T1K–08TRS Relay Output
Note: Apply the labels that come with the I/O module to the I/O base to properly identify the terminal points.
Outputs Per Module
8
Output Type
Relay Form A (SPST) normally open
Commons Per Module
8, 1 pt. / common (isolated)
Operating Voltage Range
6–240 VAC (47–63Hz), 6–27 VDC
89 (3.5)
9.2 (0.36) 8.1 (0.32)
Output Points
5–264 VAC (47–63Hz) min. / max. 5–30 VDC min. / max.
Max. Load Current
7A / pt. (subject to derating)
Max. Leakage Current
0.1mA @ 264 VAC
Max. Inrush Current
8A for 10ms
Min. Load
5mA @ 5VDC
OFF to ON Response
< 15ms
ON to OFF Response
< 10ms
Base Power Required
400mA @ 5VDC
Status Indicators
Logic Side
Error Status Indications (LEDS)
FU1/ FU2 ON = fuse 1 or 2 blown FU3/ FU4 ON = fuse 3 or 4 blown FU5/ FU6 ON = fuse 5 or 6 blown FU7/ FU8 ON = fuse 7 or 8 blown
Fuses (User Replaceable) T1K–FUSE–3
8, (10A, 250V / common), (1 pt. / fuse) NQ3–10 SOC Corp.
Weight
185g
C0
2
C1
Note: See other side for wiring example.
3
C2
4
C3
5
6
Fuses located under top cover
7
L
L
L
L
C4
C5
C6
C7
Commons
V0
V1
FU1
FU3
FU5
FU7
FU2
FU4
FU6
FU8
25.7(1.01)
Output Voltage Range
1
54.3(2.14) 80 (3.15)
08TRS
0
6-240VAC 6-27VDC V2
V3
8.1 (0.32)
Note: V0 – V3 not used on Relay Output Modules mm (in.) 83.3 (3.28)
Equivalent Output Circuit Internal Module Circuitry
Environmental Specifications Ambient Operating Temperature
32_F to 131_F (0_C to 55_C)
Storage Temperature
–4_F to 158_F (–20_C to 70_C)
Ambient Humidity
5% to 95% (Non–condensing)
Atmosphere
No corrosive gases. The level of environmental pollution = 2 (UL 840)
Vibration Resistance
MIL STD 810C, Method 514.2
Shock Resistance
MIL STD 810C, Method 516.2
Voltage Withstand
1500VAC, 1 minute
Insulation Resistance
500VDC, 10M ohm
Noise Immunity
NEMA ICS3–304 Impulse Noise 1us, 1000V FCC class A RFI (144MHz, 430MHz 10W, 10cm)
Agency Approvals
UL, CE, FCC class A
+V
Output
L To LED AC or DC Supply
10A
Side View
COM 6-27VDC 6-240VAC
Derating Chart Typical Relay Life (Operations) at Room Temperature Voltage & Type of Load
Points 8
Load Current 5A 2A
24 VDC Resistive
1000K
500K
200K
100K
24 VDC Solenoid
300K
100K
**
**
110 VAC Resistive
1000K
500K
200K
100K
110 VAC Solenoid
300K
100K
**
**
220 VAC Resistive
500K
250K
125K
60K
220 VAC Solenoid
300K
100K
**
**
** Solenoid (inductive) loads > 2A cannot be used.
7A
4A 5A
6
6A
4
7A
2 0 0 32
10 20 30 40 50 55 °C 50 68 86 104 122 131 ° F Ambient Temperature (°C/°F)
3–45
1A
Page 73
Wiring & Dimensions
0–20mA, 4–20mA, –20 to 20mA
Resolution
14 bit (13 bit plus sign bit)
Frequency Response
T1F–08AD–1 Fuse
–3db @ 500Hz, –20db/decade 250 ohm
Absolute Max. Ratings
8V max. input Normal Mode: 5ms per channel *Fast Mode: 0.5ms per channel
Linearity Error
+ / – 2 count max.
Input Stability
+ / – 1 count
Full Scale Error (Offset Error not included)
16 counts max.
Offset Error
2 counts max.
Max. Full Scale Inaccuracy (% of full scale) all errors included
0.18% @ 25_C 0.36% @ 60_C
Master Update Rate
8 channels per scan max.
Input Points Required
256 discrete pts. or 8 dwords (d (double) word = 32 bit word) Network Interface dependent
Base Power Required
75mA @ 5VDC
External Power Supply
18–30 VDC, 50mA, class 2
Recommended Fuse
0.032A, Series 217 Fast Acting
Operating Temperature
0 to 60_C (32 to 140_F)
Storage Temperature
–20 to 70_C (–4 to 158_F)
Accuracy vs. Temperature
+ / – 50 ppm / _C max. full scale
Relative Humidity
5 to 95% (non–condensing) No corrosive gases permitted
Vibration
MIL STD 810C 514.2
Shock
MIL STD 810C 516.2
Noise Immunity
NEMA ICS3–304
Weight
136g
Input Range Resolution: –20 to 20mA
–8192 to 8191 counts
0 – 20mA
0 – 8191 counts
4 – 20mA
1638 – 8191 counts
0
2–Wire Current Transmitter
Transmitter Supply 18-30VDC
E
D
1
2
B 6 1 C 5 3
2
4 4
3 5
6
7
0 1 2 3 4 5 6 7
-
+ Module Supply 24VDC
Note: V1 internally connected to Commons
8.1 (0.32) mm (in.)
83.3 (3.28) NOTES: 1: Shields should be grounded at the signal source. 2: More than one external power supply can be used, provided all the power supply commons are connected. 3: A Series 217, 0.032A fast-acting fuse is recommended for 4–20 mA current loops. 4: If the power supply common of an external power supply is not connected to the 0V terminal on the module, then the output of the external transmitter must be isolated. To avoid “ground loop” errors, recommended 4–20 mA transmitter types are: –For 2 or 3 wire connections: Isolation between the input supply signal and the power supply. –For 4 wire connections: Isolation between the input supply signal, the power supply and the 4–20mA output.
Side View
Equivalent Input Circuit Transmitter Supply 18-30VDC
+
+
-
-
See NOTE 1 +
+
4 – 20mA 20mA
20mA
4mA
Internal Module Circuitry
Input
– 3–Wire Current Transmitter
Input Signal Ranges
Module Supply 24VDC V0 V1 mm (in.)
0 – 20mA
Fuse 250 ohms
0mA Analog Switch
Environmental Air
4–Wire Current Transmitter
A
+
Conversion Time (Default: Normal Mode)
F
Commons (not isolated)
-
+
Input Resistance
Fuse
80 (3.15)
Input Ranges
Input points
25.7(1.01)
8, single ended (1 common)
8.1 (0.32)
54.3(2.14)
T1F–08AD–1 8 Channel Current Analog Input Number of Channels
48 (1.89)
9.2 (0.36)
Rev B
3–46
Specifications
0
1638
8191 –20 to 20mA
A to D Converter
20mA 0mA
*Fast mode supported in module hardware version B or later.
COM
–20mA –8191
8191
8191
Page 74
Wiring & Dimensions
0–5V, 0–10V, +/– 5V, +/– 10V
Resolution
14 bit (13 bit plus sign bit)
Frequency Response
–3db @ 500Hz, –20db/decade
Input Resistance
200K ohm min.
Absolute Max. Ratings
Fault Protected Input 130V(rms) or 100VDC
T1F–08AD–2 F
-
Normal Mode: 5ms per channel *Fast Mode: 0.5ms per channel
Linearity Error
+ / – 2 count max.
Input Stability
+ / – 1 count
Calibration Full Scale Error
8 counts max.
Calibration Offset Error
2 counts max.
Max. Full Scale Inaccuracy (% of full scale); all errors included
0.08% @ 25_C 0.26% @ 60_C
Master Update Rate
8 channels per scan max.
Input Points Required
256 discrete pts. or 8 dwords (d (double) word = 32 bit word) Network Interface dependent
Base Power Required
75mA @ 5VDC
External Power Supply
18–30 VDC, 50mA, class 2
Operating Temperature
0 to 60_C (32 to 140_F)
Storage Temperature
–20 to 70_C (–4 to 158_F)
Accuracy vs. Temperature
+ / – 50 ppm / _C max. full scale
0
4–Wire Voltage Transmitter
5 to 95% (non–condensing)
Environmental Air
No corrosive gases permitted
Vibration
MIL STD 810C 514.2
Shock
MIL STD 810C 516.2
Noise Immunity
NEMA ICS3–304 weight
136g
Transmitter Supply 18-30VDC + Module Supply 24VDC
Note: V1 internally connected to Commons
0 – 8191 counts
+ / – 5V
–4095 to 4095 counts
+ / – 10V
–8192 to 8191 counts
5
6
7 mm (in.)
83.3 (3.28)
–5 to 5V
0 – 10V 5V
10V
5V
0V
0
4095
0V
–5V
0V
0V
0
8191
–10 to 10V 10V
Side View mm (in.)
–10V –4095
4095
–8192
8191
Equivalent Input Circuit Transmitter Supply 18-30VDC
– 3–Wire Voltage Transmitter
*Fast mode supported in module hardware version B or later.
+
+
-
-
Module Supply 24VDC V0 V1 Input
+
COM
Internal Module Circuitry
A to D Converter
3–47
0 – 10V
4 4
Analog Switch
0 – 4095 counts
3
Input Signal Ranges
+
0 – 5V
2
2 3
8.1 (0.32)
NOTES: 1: Shields should be grounded at the signal source. 2: Unused inputs should be connected to Common (0VDC). 3: More than one external power supply can be used, provided all the power supply commons are connected.
See NOTE 1
Input Range Resolution:
D
1
C 5
0 1 2 3 4 5 6 7
0 – 5V
Relative Humidity
E
B 6 1
+
Conversion Time (Default: Normal Mode)
Commons (not isolated)
A
25.7(1.01)
Input Ranges
Input points
+
8, single ended (1 common)
8.1 (0.32)
80 (3.15)
T1F–08AD–2 8 Channel Voltage Analog Input Number of Channels
48 (1.89)
9.2 (0.36)
Rev B
54.3(2.14)
Specifications
Page 75
89 (3.5)
9.2 (0.36) 8.1 (0.32)
T1F–16AD–1 16 Channel Current Analog Input Number of Channels
16, single ended (1 common)
Input Ranges
0–20mA, 4–20mA, –20 to 20mA
Resolution
14 bit (13 bit plus sign bit)
Frequency Response
–3db @ 500Hz, –20db/decade
Input Resistance
250 ohm
Absolute Max. Ratings
8V max. input
+
Conversion Time
5ms per channel
Linearity Error
+ / – 2 count max.
4–Wire Current Transmitter
Input Stability
+ / – 1 count
Full Scale Error (Offset Error not included)
16 counts max.
Offset Error
2 counts max.
Max. Full Scale Inaccuracy (% of full scale) all errors included
0.18% @ 25_C , 0.36% @ 60_C
Master Update Rate
16 channels per scan max.
Input Points Required
512 discrete pts. or 16 dwords (d (double) word = 32 bit word) Network Interface dependent
Base Power Required
75mA @ 5VDC
External Power Supply
18–30 VDC, 50mA, class 2
Recommended Fuse
0.032A, Series 217 Fast Acting
Operating Temperature
0 to 60_C (32 to 140_F)
Storage Temperature
–20 to 70_C (–4 to 158_F)
Accuracy vs. Temperature
+ / – 50 ppm / _C max. full scale
Relative Humidity
5 to 95% (non–condensing)
Environmental Air
No corrosive gases permitted
3–48
Wiring & Dimensions
54.3(2.14)
Input points 0 1 2 3 4 5 6 7 8 9 10 11 12 13 1415
Fuse
Fuse
Commons (not isolated) COM 0
COM 1
COM 2
COM 3
V2
V3
2–Wire Current Transmitter
25.7(1.01)
-
+ Transmitter Supply 18-30VDC V0
V1
8.1 (0.32)
-
Note: V0 and V1 internally Module Supply connected 24VDC
Note: V2 and V3 internally connected to Commons
+ mm (in.)
83.3 (3.28) NOTES: 1: Shields should be grounded at the signal source. 2: More than one external power supply can be used, provided all the power supply commons are connected. 3: A Series 217, 0.032A fast-acting fuse is recommended for 4–20 mA current loops. 4: If the power supply common of an external power supply is not connected to the 0V terminal on the module, then the output of the external transmitter must be isolated. To avoid “ground loop” errors, recommended 4–20 mA transmitter types are: –For 2 or 3 wire connections: Isolation between the input supply signal and the power supply. –For 4 wire connections: Isolation between the input supply signal, the power supply and the 4–20mA output.
side View
Shock
MIL STD 810C 516.2
Noise Immunity
NEMA ICS3–304
Weight
168g
Transmitter Supply 18-30VDC +
+
-
-
See NOTE 1 +
Input
–
Input Range Resolution: –20 to 20mA
–8192 to 8191 counts
0 – 20mA
0 – 8191 counts
4 – 20mA
1638 – 8191 counts
3–Wire Current Transmitter
+
Module Supply 24VDC
4 – 20mA 20mA
20mA
V0-V1 V2-v3 Internal Module Circuitry
Fuse 250 ohms
4mA 0mA Analog Switch
MIL STD 810C 514.2 mm (in.)
Input Signal Ranges
Equivalent Input Circuit
0 – 20mA
Vibration
80 (3.15)
Specifications
0
1638
8191
–20 to 20mA A to D Converter
20mA 0mA
COM
–20mA –8191
8191
8191
Page 76
Wiring & Dimensions 89 (3.5)
9.2 (0.36) 8.1 (0.32)
T1F–16AD–2 16 Channel Voltage Analog Input Input Ranges
0–5V, 0–10V, +/– 5V, +/– 10V
Resolution
14 bit (13 bit plus sign bit)
Frequency Response
–3db @ 500Hz, –20db/decade
Input Resistance
200K ohm min.
Absolute Max. Ratings
Fault Protected Input 130V(rms) or 100VDC
Conversion Time
5ms per channel
Linearity Error
+ / – 2 count max.
Input Stability
+ / – 1 count
Calibration Full Scale Error
8 counts max.
Calibration Offset Error
2 counts max.
Max. Full Scale Inaccuracy (% of full scale); all errors included
0.08% @ 25_C 0.26% @ 60_C
Master Update Rate
16 channels per scan max.
Input Points Required
512 discrete pts. or 16 dwords (d (double) word = 32 bit word) Network Interface dependent
Base Power Required
75mA @ 5VDC
External Power Supply
18–30VDC, 50mA, class 2
Operating Temperature
0 to 60_C (32 to 140_F)
Storage Temperature
–20 to 70_C (–4 to 158_F)
Accuracy vs. Temperature
+ / – 50 ppm / _C max. full scale
Relative Humidity
Input points 54.3(2.14)
16, single ended (1 common)
0 1 2 3 4 5 6 7 8 9 10 11 12 13 1415
+
Commons (not isolated)
-
4–Wire Voltage Transmitter
COM 0
COM 1
COM 2
COM 3 2
+ Transmitter Supply 18-30VDC V0
V2
V1
V3
8.1 (0.32)
-
Note: V0 and V1 Internally Module Supply connected 24VDC
Note: V2 and V3 internally connected to Commons
+ mm (in.)
83.3 (3.28) NOTES: 1: Shields should be grounded at the signal source. 2: Unused inputs should be connected to Common (0VDC). 3: More than one external power supply can be used, provided all the power supply commons are connected.
Input Signal Ranges –5 to 5V
0 – 10V
0 – 5V
–10 to 10V
5V
10V
5V
10V side View
5 to 95% (non–condensing)
Environmental Air
No corrosive gases permitted
Vibration
MIL STD 810C 514.2
Shock
MIL STD 810C 516.2
Noise Immunity
NEMA ICS3–304
Weight
168g
Input Range Resolution:
0V
0
4095
0
8191
0 – 8191 counts
+ / – 5V
–4095 to 4095 counts
+ / – 10V
–8192 to 8191 counts
4095
–8192
8191
Equivalent Input Circuit Transmitter Supply 18-30VDC
+ – 3–Wire Voltage Transmitter
+
+
-
-
Module Supply 24VDC V0-V1 V2-V3 Input
+
COM
Internal Module Circuitry
A to D Converter
3–49
0 – 10V
–10V –4095
Analog Switch
0 – 4095 counts mm (in.)
0V
–5V
0V
0V
See NOTE 1
0 – 5V
80 (3.15)
Number of Channels
25.7(1.01)
Specifications
Page 77
Wiring & Dimensions 48 (1.89)
9.2 (0.36)
T1F–08DA–1 8 Channel Current Analog Output
3–50
Specifications
8.1 (0.32)
Output Points
8
Output Ranges
0–20mA, 4–20mA
Output Type single ended, 1 common
Resolution
12 bit (1 in 4096)
Commons (not isolated)
30 VDC 30 VDC
Max. Load (Ohm) / Power Supply
620/18V, 910/24V, 1200/30V
Min. Load (ohm) / Power Supply**
0/24V, 350/30V @ 40_C 250/24V, 600/30V @ 60_C
Linearity Error (end to end)
+ / – 2 count max. + / – 0.050% of full scale max
Conversion Settling Time
400us max. full scale change
Full Scale Calibration Error
+ / – 12 counts max.
Offset Calibration Error
0 – 20mA: + / – 5 counts max. 4 – 20mA: + / – 6 counts max.
Accuracy vs. Temperature
+ / – 50 ppm/_C full scale calibration change
Max. Full Scale Inaccuracy (% of full scale) all errors included
0.2% @ 25_C , 0.4% @ 60_C
Master Update Rate
8 channels per scan max.
Output Points Required
256 disctete pts. or 8 dwords (d (double) word = 32 bit word) Network Interface dependent
Base Power Required
75mA @ 5VDC
External Power Supply
21.6–26.4VDC, 150mA class 2
0
0 to 60_C (32 to 140_F)
Storage Temperature
–20 to 70_C (–4 to 158_F)
Relative Humidity
5 to 95% (non–condensing)
Environmental Air
No corrosive gases permitted
Vibration
MIL STD 810C 514.2
Shock
MIL STD 810C 516.2
Noise Immunity
NEMA ICS3–304
Weight
145g
**max. allowable output power dissipation. For example, at 60_C and 24VDC, there must be a load of at least 250 ohms on the output circuit. Smaller loads will damage the analog output circuit.
D
1
2
C 5 3
4 4
2 3 5
6
7
0 1 2 3 4 5 6 7
Loop Supply 18-30VDC
+ Module Supply 24VDC
8.1 (0.32)
Note: V1 internally connected to Commons mm (in.)
NOTES: 1: Shields should be connected to the 0V terminal of the module or the 0V of the power supply. 2. Unused current outputs should remain open (no connections) for minimum power consumption.
83.3 (3.28)
Output Signal Ranges 4 – 20mA
0 – 20mA 20mA
20mA
Side View
4mA 0mA
Operating Temperature
E
B 6 1
+
Peak Output Voltage
Load 250 ohms typical
A
25.7(1.01)
Max. Loop Supply
F
80 (3.15)
Number of Channels
54.3(2.14)
Rev B
0
0
4095 mm (in.)
4095
Equivalent Output Circuit Loop Supply 18-30VDC See Note 1
+
+
-
-
Load 250 ohms typical
Module Supply 24VDC V0 V1 Output
Internal Module Circuitry Current sinking
D to A Converter
Note: This module requires software setup via the Module Control Byte. Refer to the Memory Map Chapter in the T1K–INST–M Installation and I/O Manual.
COM
Page 78
Specifications
Wiring & Dimensions 48 (1.89)
9.2 (0.36)
T1F–08DA–2 8 Channel Voltage Analog Output
8.1 (0.32)
Output Points
0–5V, 0–10V, +/– 5V, +/– 10V
Output Type single ended, 1 common
Resolution
12 bit (1 in 4096)
Peak Output Voltage
15 VDC
Load Impedance
4K ohm min.
Load Capacitance
0.01uF max.
Linearity Error (end to end)
+ / – 2 count max. + / – 0.050% of full scale max
Conversion Settling Time
100us max. full scale change
Full Scale Calibration Error
+ / – 12 counts max.
Offset Calibration Error
10V ranges:+ / – 6 counts max 5V ranges: + / – 11 counts max
Accuracy vs. Temperature
+ / – 50 ppm/_C full scale calibration change
Max. Full Scale Inaccuracy (% of full scale); all errors and temp drift included
10V ranges:+ / –0.2% @ 25_C + / –0.4% @ 60_C 5V ranges: + / –0.3% @ 25_C + / –0.5% @ 60_C
Master Update Rate
8 channels per scan max.
Output Points Required
256 discrete pts. or 8 dwords (d (double) word = 32 bit word) Network Interface dependent
Base Power Required
F
Commons (not isolated) Load 4K ohm minimum
21.6–26.4VDC, 150mA class 2
Operating Temperature
0 to 60_C (32 to 140_F)
Storage Temperature
–20 to 70_C (–4 to 158_F)
Relative Humidity
5 to 95% (non–condensing)
Environmental Air
No corrosive gases permitted
Vibration
MIL STD 810C 514.2
Shock
MIL STD 810C 516.2
Noise Immunity
NEMA ICS3–304
Weight
145g
D
1
2
C 5 3
4 4
2 3 5
6
7
8.1 (0.32)
Note: V1 internally connected to Commons mm (in.)
NOTES: 1: Shields should be connected to the 0V terminal of the module ot the 0V terminal of the power supply. 2. Unused voltage outputs should remain open (no connections) for minimum power consumption.
0V – 10V
5V
–5V to +5V
10V
0V
–10V to +10V
+5V
+10V
0V
0V
–5V
–10V
Side View
0V 4095
83.3 (3.28)
Bipolar Ranges
Unipolar Ranges 0V – 5V
0
0
4095
0 (+2047) +4095 mm (in.)
0 (+2047)+4095
Equivalent Output Circuit Module Supply 24VDC + V0 V1
See Note 1
Output
Load 4K ohm minimum
COM
Internal Module Circuitry Voltage Sink/Source
D to A Converter
3–51
Note: This module requires software setup via the Module Control Byte. Refer to the Memory Map Chapter in the T1K–INST–M Installation and I/O Manual.
E
B 6 1
0 1 2 3 4 5 6 7
+ Module Supply 24VDC
75mA @ 5VDC
External Power Supply
0
A
80 (3.15)
8
Output Ranges
25.7(1.01)
Number of Channels
54.3(2.14)
Rev B
Page 79
0–20mA, 4–20mA
Output Type single ended, 1 common
Resolution
12 bit (1 in 4096)
Max. Loop Supply
30 VDC
Peak Output Voltage
30 VDC
Max. Load (ohm) / Power Supply
620/18V, 910/24V, 1200/30V
Min. Load (ohm) / Power Supply**
0/24V, 350/30V @ 40_C 250/24V, 600/30V @ 60_C
Linearity Error (end to end)
+ / – 2 count max. + / – 0.050% of full scale max
Conversion Settling Time
400us max. full scale change
Full Scale Calibration Error
+ / – 12 counts max.
Offset Calibration Error
0 – 20mA: + / – 5 counts max. 4 – 20mA: + / – 6 counts max.
Accuracy vs. Temperature
+ / – 50 ppm/_C full scale calibration change
Max. Full Scale Inaccuracy (% of full scale) all errors included
0.2% @ 25_C, 0.4% @ 60_C
Master Update Rate
16 channels per scan max.
Output Points Required
512 discrete pts. or 16 dwords (d (double) word = 32 bit word) Network Interface dependent
Base Power Required
75mA @ 5VDC
External Power Supply
21.6–26.4VDC, 150mA class 2
Operating Temperature
0 to 60_C (32 to 140_F)
Storage Temperature
–20 to 70_C (–4 to 158_F)
Relative Humidity
5 to 95% (non–condensing)
Environmental Air
No corrosive gases permitted
Vibration
MIL STD 810C 514.2
Shock
MIL STD 810C 516.2
Noise Immunity
NEMA ICS3–304
Weight
172g
**max. allowable output power dissipation. For example, at 60_C and 24VDC, there must be a load of at least 250 ohms on the output circuit. Smaller loads will damage the analog output circuit.
Output Points 54.3(2.14)
Output Ranges
0 1 2 3 4 5 6 7 8 9 10 11 12 13 1415
Commons (not isolated)
Load 250 ohms typical
Loop Supply 18-30VDC +
COM 0
COM 1
COM 2
COM 3
V0
V1
V2
V3
+
16
8.1 (0.32)
Note: V0 and Module Supply V1 Internally 24VDC connected
8.1 (0.32)
Note: V2 and V3 internally connected to Commons mm (in.)
83.3 (3.28)
NOTES: 1: Shields should be connected to the 0V terminal of the module or the 0V of the power supply. 2. Unused current outputs should remain open (no connections) for minimum power consumption.
Output Signal Ranges 4 – 20mA
0 – 20mA 20mA
20mA side View 4mA 0mA 0
0
4095
See Note 1 Load 250 ohms typical
4095
Equivalent Output Circuit Loop Supply 18-30VDC
80 (3.15)
Rev B Number of Channels
89 (3.5)
9.2 (0.36)
25.7(1.01)
T1F–16DA–1 16 Channel Current Analog Output
Note: This module requires software setup via the Module Control Byte. Refer to the Memory Map Chapter in the T1K–INST–M Installation and I/O Manual.
3–52
Wiring & Dimensions
Specifications
+
+
-
-
Module Supply 24VDC V0-V1 V2-V3 Output
Internal Module Circuitry Current sinking
D to A Converter
COM mm (in.)
Page 80
Wiring & Dimensions
Specifications
89 (3.5)
9.2 (0.36) 8.1 (0.32)
T1F–16DA–2 16 Channel Voltage Analog Output Rev B
0–5V, 0–10V, +/– 5V, +/– 10V
Output Type single ended, 1 common
Resolution
12 bit (1 in 4096)
Peak Output Voltage
15 VDC
Load Impedance
4K ohm min.
Load Capacitance
0.01uF max.
Linearity Error (end to end)
+ / – 2 count max. + / – 0.050% of full scale max
Conversion Settling Time
100us max. full scale change
Full Scale Calibration Error
+ / – 12 counts max.
Offset Calibration Error
10V ranges:+ / – 6 counts max 5V ranges: + / – 11 counts max
Accuracy vs. Temperature
+ / – 50 ppm/_C full scale calibration change
Max. Full Scale Inaccuracy (% of full scale); all errors and temp drift included
10V ranges:+ / –0.2% @ 25_C + / –0.4% @ 60_C 5V ranges: + / –0.3% @ 25_C + / –0.5% @ 60_C
Master Update Rate
16 channels per scan max.
Output Points Required
512 discrete pts. or 16 dwords (d (double) word = 32 bit word) Network Interface dependent
Base Power Required
75mA @ 5VDC
External Power Supply
Output Points 0 1 2 3 4 5 6 7 8 9 10 11 12 13 1415
Commons (not isolated)
Load 4K ohm minimum
Storage Temperature
–20 to 70_C (–4 to 158_F)
Relative Humidity
5 to 95% (non–condensing)
Environmental Air
No corrosive gases permitted
Vibration
MIL STD 810C 514.2
Shock
MIL STD 810C 516.2
Noise Immunity
NEMA ICS3–304
Weight
172g
COM 1
COM 2
COM 3
V0
V1
V2
V3
-
Note: V0 and V1 Internally connected
Module Supply 24VDC
Unipolar Ranges 0V – 5V mm (in.)
83.3 (3.28)
Bipolar Ranges
10V
0V
0V 0
4095
–5V to +5V
0V – 10V
+10V
0V
0V
–5V 0
4095
–10V to +10V
+5V side View mm (in.)
–10V
0 (+2047) +4095
0 (+2047)+4095
Equivalent Output Circuit Module Supply 24VDC + V0-V1 V2-V3
See Note 1
Output
Load 4K ohm minimum
COM
Internal Module Circuitry Voltage Sink/Source
D to A Converter
3–53
Note: This module requires software setup via the Module Control Byte. Refer to the Memory Map Chapter in the T1K–INST–M Installation and I/O Manual.
8.1 (0.32)
Note: V2 and V3 internally connected to Commons
NOTES: 1: Shields should be connected to the 0V terminal of the module or the 0V of the power supply. 2. Unused voltage outputs should remain open (no connections) for minimum power consumption.
5V
0 to 60_C (32 to 140_F)
COM 0
+
21.6–26.4VDC, 150mA class 2
Operating Temperature
54.3(2.14)
Output Ranges
80 (3.15)
16
25.7(1.01)
Number of Channels