Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of Terminator I/O Installation and I/O Manual

Manual · AutomationDirect

Terminator I/O Installation and I/O Manual

Manual127 pagesPDF 4.1 MB

Installation and I/O manual for AutomationDirect Terminator I/O, including the T1K-01DC power supply and T1K-08TRS relay output module.

Download the PDF4.1 MB

Covers · 6 models

The models it covers

Summary

What is in it

The AutomationDirect Terminator I/O installation and I/O manual (manual number T1K-INST-M). It introduces the Terminator I/O system components, then covers safety, mounting, DIN rail assembly and power wiring, I/O wiring strategies, sinking and sourcing, relay output guidelines, wiring and specifications for each module (including the T1K-01AC and T1K-01DC power supplies and the T1K-08TRS relay output), power budget calculation, hot swap, and the I/O memory map and analog module resolution.

Its parts

  1. Introduction
  2. Installation and Power Wiring
  3. I/O Wiring and Specifications
  4. I/O Memory Map and Analog Module Resolution

From the manual

Key facts from this manual

Each line names its page in the PDF.

This is the Terminator I/O Installation and I/O Manual (T1K-INST-M) for the whole Terminator I/O family, including the T1K-01DC power supply and the T1K-08TRS relay output module. It shows how to install and wire the power supplies, bases and I/O modules, lists each module's specifications, and explains how to work out a power budget.

Read for this summary: pages 1 to 4, 9 to 13, 20, 27, 36, 40, 44 to 46, 51 and 72 of 127.

Document
Terminator Installation and I/O Manual, manual number T1K-INST-M p. 4
Operating temperature
32° F to 131° F (0° C to 55° C); storage -4° F to 158° F (-20° C to 70° C) p. 20
Input power
T1K-01DC: 12/24VDC (10.8-26.4VDC) with less than 10% ripple, 20W max. p. 20, 51
Relay outputs
T1K-08TRS: 8 relay outputs, Form A (SPST) normally open, 1 point per isolated common p. 72
Base power output
T1K-01DC: 5.25VDC (5.00-5.50VDC), 2000 mA, 5% max. ripple p. 45, 51
Load current
T1K-08TRS: 7A per point max. (subject to derating); 8A inrush for 10ms; 5mA @ 5VDC min. load p. 72
Relay voltage range
T1K-08TRS: 6-240 VAC (47-63Hz), 6-27 VDC p. 72
Fuses
T1K-08TRS: 8 user-replaceable T1K-FUSE-3 fuses (10A, 250V), 1 per point; NQ3-10 SOC Corp. p. 72
Module power draw
T1K-08TRS: 400mA @ 5VDC, 0 mA at 24VDC p. 46, 72
Fuse LEDs
T1K-08TRS: LEDs FU1/FU2 through FU7/FU8 light when a fuse in that pair is blown p. 72
System size
Up to 16 I/O modules per slave (node), in one base row plus two local expansion rows p. 13
Supply terminals
T1K-01DC: 24-12 AWG solid or stranded wire, torque 4.43-5.31 lb-in (0.5-0.6 Nm) p. 27
Response time
T1K-08TRS: OFF to ON < 15ms, ON to OFF < 10ms p. 72
Weight
T1K-08TRS: 185g p. 72

What this manual walks you through

  • Wiring the AC and DC power supply terminals p. 27
  • Calculating the power budget and adding power supplies p. 45, 46
  • Choosing relay outputs and prolonging relay contact life p. 36
  • Wiring screw clamp and spring clamp I/O bases p. 40
  • Hot swapping an I/O module with power on p. 44
  • Checking the installation environment against the environmental specifications p. 20
  • Understanding the parts of a Terminator I/O system and its base controllers p. 12, 13

Good to know

  • Exceeding the power budget may make the system operate unpredictably. p. 45
  • T1K-08TRS: solenoid (inductive) loads over 2A cannot be used. p. 72
  • Relays are not suited to loads under 10 mA or to high-speed or heavy duty cycle switching. p. 36
  • The base controller and power supply cannot be hot swapped. p. 13
  • Field device power may still be on the terminal block with system power off. p. 40

Questions this manual answers

What input voltage does the T1K-01DC need?

12/24VDC, within 10.8 to 26.4VDC, with less than 10% ripple. p. 20

Does the T1K-01DC have a 24VDC auxiliary output?

No. The power supply chart lists auxiliary 24VDC current only for the T1K-01AC (300 mA), none for the T1K-01DC. p. 20, 45

What fuse does the T1K-08TRS take?

T1K-FUSE-3 (10A, 250V), eight per module, one per point, located under the top cover. p. 72

How much current can each T1K-08TRS relay output switch?

Up to 7A per point, subject to derating. p. 72

Can a Terminator I/O module be replaced with power on?

Yes, discrete and analog I/O modules can be hot swapped, but not the base controller or power supply, and not every base controller supports it. p. 44

The whole text · 13 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20
  3. Pages 21 to 3021-30
  4. Pages 31 to 4031-40
  5. Pages 41 to 5041-50
  6. Pages 51 to 6051-60
  7. Pages 61 to 7061-70
  8. Pages 71 to 8071-80
  9. Pages 81 to 9081-90
  10. Pages 91 to 10091-100
  11. Pages 101 to 110101-110
  12. Pages 111 to 120111-120
  13. Pages 121 to 127121-127

The file

Revision and size

RevisionT1K-INST-M
PublisherAutomationDirect
Pages127
PDF4.1 MB
TextText from the PDF itself; page 1 is a scan, read by OCR, which may hold reading errors.

The first pages · 3 of 127

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 127
Page 2
Page 2of 127
Page 3
Page 3of 127