Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of Relay Output Modules T1K-08TRS

Spec sheet · AutomationDirect

Relay Output Modules T1K-08TRS

Spec sheet6 pagesPDF 3.4 MB

Catalog pages for the T1K-08TRS 8-point isolated relay output module of the Terminator I/O system, with installation and power data.

Download the PDF3.4 MB

Covers · 3 models

The models it covers

Summary

What is in it

Catalog pages for the T1K-08TRS, an 8-point isolated relay output module for the Terminator I/O system. They give its output specifications, typical relay life and fusing, then general Terminator I/O information: dimensions and environmental specifications, installing and hot-swapping I/O modules, power supplies and power budgeting, expansion cable configurations, and terminal bases and field device wiring options.

Its parts

  1. Relay Output Modules
  2. Dimensions and Installation
  3. I/O Module Installation
  4. Power Supplies and Power Requirements
  5. Expansion I/O Configurations
  6. Field Device Wiring and Power Options

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

Pages from the AutomationDirect Universal Field I/O catalog for the T1K-08TRS 8-point isolated relay output module of the Terminator I/O family. Besides the module's own specification page it covers installation, power supplies and the power budget, expansion cables and terminal base wiring for Terminator I/O systems.

Device
8-point, isolated relay output module for Terminator I/O p. 1, 4
Terminal base
T1K-16B or T1K-16B-1, purchased separately p. 1
Base power
400 mA at 5VDC; 0 at 24VDC p. 4
Fuses
User replaceable T1K-FUSE-3, one point per fuse p. 1
Fuse LEDs
FU1/FU2 lit means fuse 1 or 2 blown, and likewise FU3/FU4, FU5/FU6, FU7/FU8 p. 1
Inductive loads
Solenoid (inductive) loads above 2A cannot be used p. 1
Hot swap
I/O modules can be removed and replaced with system power on p. 3, 6
Terminal wiring
Screw type bases: 1.77-3.54 lb-in (0.2 - 0.4 Nm), solid 25-12 AWG, stranded 26-12 AWG; spring clamp bases: solid 25-14 AWG, stranded 26-14 AWG p. 6
Mounting
On DIN rail, horizontally, never upside-down p. 2, 3
Power supply example
T1K-01AC supplies 2000 mA at 5VDC and 300 mA at 24VDC in the power budget example p. 4
Expansion cables
T1K-10CBL(-1), T1K-05CBL-RR(-1) and T1K-05CBL-LL(-1); the (-1) versions also pass 24 VDC p. 5

What this sheet walks you through

  • Installing an I/O module in its terminal base and on DIN rail p. 3
  • Removing an I/O module from its base p. 3
  • Checking unit dimensions and mounting orientation p. 2
  • Calculating the power budget for each power supply p. 4
  • Laying out expansion bases with expansion cables p. 5
  • Powering field devices from the bussed or an external 24 VDC supply p. 6

Good to know

  • Solenoid (inductive) loads over 2A cannot be used on this module. p. 1
  • When hot swapping, do not touch the terminals, and remove power when it is just as convenient. p. 6
  • Do not jumper modules together into a 24 VDC bus when using hot swap; wire each module to the external supply. p. 6
  • The catalog does not replace the product's technical data sheet or the T1K-INST-M Installation and I/O Manual. p. 2

Questions this sheet answers

What base does the T1K-08TRS need?

A T1K-16B or T1K-16B-1 terminal base, which is purchased separately. p. 1

What fuse does the T1K-08TRS use?

User replaceable T1K-FUSE-3 fuses; LEDs such as FU1/FU2 light when a fuse in that pair is blown. p. 1

Can the T1K-08TRS drive solenoid valves?

Only solenoid (inductive) loads of 2A or less; larger inductive loads cannot be used. p. 1

How much power does the T1K-08TRS draw from the supply?

400 mA at 5VDC and none at 24VDC, per the power requirements table. p. 4

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Relay Output Modules1
  2. Dimensions and Installation2
  3. I/O Module Installation3
  4. Power Supplies and Power Requirements4
  5. Expansion I/O Configurations5
  6. Field Device Wiring and Power Options6

From the PDF’s own bookmarks.

The whole text · 1 part

Read the sheet here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 61-6

The file

Revision and size

RevisionVolume 13
PublisherAutomationDirect
Pages6
PDF3.4 MB
TextText from the PDF itself.

The first pages · 4 of 6

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 6
Page 2
Page 2of 6
Page 3
Page 3of 6
Page 4
Page 4of 6

More documents · 1

For the same models