The text of a manual · part 3 of 20
Do-more T1H Series PLC Hardware User Manual: Chapter 1. Getting Started, pages 13 to 20
Pages 13 to 20 of 168, from Do-more T1H Series PLC Hardware User Manual
The original document is the PDF (40 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the AutomationDirect T1K-08B, Konnect-It T1K-08B and Koyo T1K-08B
Page 13
Getting Started
Chapter
1
In This Chapter: Introduction . ........................................................................................................... 1–2 Purpose of this Manual. ............................................................................................ 1–2 Purpose of this Chapter. ........................................................................................... 1–2 Online Help Files and Other Documentation............................................................. 1–2 Technical Support..................................................................................................... 1–2 Conventions Used. ..................................................................................................... 1–3 Key Topics for Each Chapter. .................................................................................... 1–3 Before You Begin. ...................................................................................................... 1–4 Do-more T1H Series PLC System Components.......................................................... 1–5 Do-more Software System Requirements. ................................................................. 1–6 Step 1: Install Do-more Designer Software............................................................... 1–7 Step 2: Launch Do-more Designer Software........................................................... 1–10 Step 3: Install Hardware. ......................................................................................... 1–12 Step 4: Apply Power to the PLC ............................................................................. 1–13 Step 5: Establish Communication............................................................................ 1–14 Step 6: Verify Hardware Configuration................................................................... 1–20 Step 7: Create a Ladder Logic Program. ................................................................. 1–24 Rung #1.................................................................................................................. 1-24 Rung #2.................................................................................................................. 1-27 Step 8: Save a Project. ............................................................................................. 1–29 Step 9: Write Project to the Do-more T1H Series PLC . ......................................... 1–29 Step 10: Testing Project Using Data View............................................................... 1–30 Accessing the Help File. ........................................................................................... 1–32
Page 14
Chapter 1: Getting Started
1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D
Introduction
1–2
Purpose of this Manual Thank you for purchasing from our Do-more PLC family of products. This manual shows you how to install, set up, program, troubleshoot and maintain your Do-more T1H Series PLC. For installation personnel, this manual contains information on power and signal wiring, mounting details and configuration procedures. This manual can be very helpful as a quick reference guide for those who are experienced in PLCs. For those who may be new to PLCs or our products, reading this manual will give you an understanding of the variety of features available with the Do-more PLC.
Purpose of this Chapter This chapter will guide you through the basic set up of a Do-more T1H Series PLC. It contains step by step instructions on installing the programming software, installing and configuring your hardware, applying power to the PLC, establishing a communications link, and creating, saving and writing a project to the CPU. Once these steps are completed, your Do-more T1H Series PLC will be running a ladder logic project that you have programmed.
Online Help Files and Other Documentation Do-more Designer, the Do-more PLC programming software, is available for free download from our website at: http://www.automationdirect.com
The software includes searchable online help topics covering all aspects of the software, instruction set, module set up and communication.
Technical Support We strive to make our manuals the best in the industry. We rely on your feedback to let us know if we are reaching our goal. If you cannot find the solution to your particular application, or, if for any reason you need technical assistance, please call us at: 770-844-4200
Our technical support group will work with you to answer your questions. They are available Monday through Friday from 9:00 A.M. to 6:00 P.M. Eastern Time. We also encourage you to visit our web site where you can find technical and non-technical information about our products and our company. http://www.automationdirect.com
Do-more T1H Series PLC Hardware User Manual, 1st Edition, Rev. A - T1H-DM-M
Page 15
Chapter 1: Getting Started
Conventions Used
1 2 When you see the “note pad” icon in the left-hand margin, the paragraph to its immediate right will be a special note. Notes represent information that may make your work quicker or more efficient. The word NOTE: in boldface will mark the beginning of the text. 3 4 5 When you see the “exclamation point” icon in the left-hand margin, the paragraph to its immediate right will be a warning. This information could prevent injury, loss of property, or even death in extreme 6 cases. Any warning in this manual should be regarded as critical information that should be read in its entirety. The word WARNING in boldface will mark the beginning of the text. 7 8 9 10 Key Topics for Each Chapter 11 The beginning of each chapter will list the key topics C that can be found in that chapter. 1 12 13 14 A B C D Getting Started!
HAPTER
In This Chapter...
Introduction .............................................................................1-2 Purpose of this Manual ....................................................................1-2 About Getting Started! ......................................................................1-2 Supplemental Manuals and Other Help ............................................1-2 Technical Support .............................................................................1-2
Conventions Used ....................................................................1-3
Do-more T1H Series PLC Hardware User Manual, 1st Edition, Rev. A - T1H-DM-M
1–3
Page 16
Chapter 1: Getting Started
Before You Begin
1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D
It is recommended that the following items be available to make this short step-by-step introduction to the Do-more T1H Series PLC go smoothly. Example Do-more T1H Series PLC T1K-01AC 110/220 VAC Power Supply
T1K-08TR Relay Output Module
Do-more T1H-DM1E CPU Module
T1K-16TD1 Discrete Output Module
T1K-08ND3 Discrete Input Module
T1H-DM1E TERM
RUN I/O ERR
RUN
STOP
USB TX RX
USB PGM PORT
PC Running Windows XP, Vista, Windows 7, Windows 8
Not available from Automationdirect.com.
Do-more Designer Programming Software
Download software from our webste at: http://www. automationdirect.com
USB-A to USB-B Programming Cable
You can also use an Ethernet or Serial (D2-DSCBL) cable for programming, but we recommend using a USB cable; just plug it in and it works.
AC Power Cord Screwdriver TW-SD-VSL-1
Wire Strippers DN-WS
Hookup Wire
Not available from Automationdirect.com.
1–4
Do-more T1H Series PLC Hardware User Manual, 1st Edition, Rev. A - T1H-DM-M
Page 17
Chapter 1: Getting Started
Do-more T1H Series PLC System Components The Do-more T1H Series CPU modules were designed for use with the Terminator I/O product line. For those not familiar with Terminator I/O, it is a modular system which combines the functions of terminal blocks and I/O modules for distributed I/O. Each Terminator I/O system contains: a Power Supply, a Base Controller, and one or more I/O Module(s). Now with the addition of the T1H CPU, standing in place of the Base Controller, the Terminator distributed I/O system becomes a complete, highly functional, stand-alone PLC system.
1 2 3 CPU T1H-DM1/T1H-DM1E 4 Power Supplies 5 120/240 VAC and 12/24 VDC power supplies are available. The AC version has a built-in 24 VDC supply. A power supply must be the leftmost component in a slave system followed by the CPU. Additional power supplies should be added between I/O modules to meet 6 power budget requirements. 7 I/O Modules A Terminator I/O module assembly consists of an I/O module and a separate base, as shown below. A complete range of discrete modules which support 12/24 VDC, 110/220 VAC and 8 up to 7A relay outputs is offered. The analog I/O modules provide 12 and 14 bit resolution and several selections of I/O signal ranges (including bipolar). The temperature input 9 modules provide 16 bit resolution with several temperature input range selections. 10 11 12 13 14 A B C D Power Supply
Do-more CPU
I/O Modules
T1H-DM1E
TERM
RUN
I/O
ERR
RUN
STOP
USB TX
RX
USB PGM PORT
I/O Module
I/O Base
Do-more T1H Series PLC Hardware User Manual, 1st Edition, Rev. A - T1H-DM-M
1–5
Page 18
Chapter 1: Getting Started
1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D 1–6
Do-more Software System Requirements The Do-more Designer Windows-based programming software works with Windows® XP (Home or Professional, 32-bit), Vista (Home, Basic, Premium, 32 or 64-bit), Windows 7 (Home, Professional, Ultimate, 32 or 64-bit) or Windows 8 (Home, Professional, Enterprise 32 or 64-bit; Windows 8 RT edition is NOT supported). Please check the following requirements when choosing your PC configuration: •
Minimum PC to PLC Connectivity, at least one of the following: - USB Port: connects to the CPU with USB-A connector (USB-A to USB-B cable) - Serial Port: connects to the CPU with RJ-12 connector (RJ-12 to DB9 or RJ-12 to USB-B serial converter cable) -E thernet Port: connects to the CPU (T1H-DM1E) with RJ-45 10Base-T or 100Base-T
(Cat5 Patch Cable)
• Disk: 100MB free disk space •
Video Display: 1024x768, 256 colors resolution (1280x720, true color recommended)
•
Windows XP, 32-bit: - 800MHz, single core CPU (2GHz, multi-core or hyperthreaded recommended) - 512MB RAM (2GB recommended)
•
Vista, Windows 7 or Windows 8, 32 or 64-bit: - 1GHz, single core CPU (2GHz, multi-core recommended) - 1GB RAM (3GB recommended)
NOTE: The PC/Laptop/Ethernet Switch connector at the “opposite end” of the PLC connector will dictate what kind of cable you will need.
Do-more T1H Series PLC Hardware User Manual, 1st Edition, Rev. A - T1H-DM-M
Page 19
Chapter 1: Getting Started
Step 1: Install Do-more Designer Software Download the Do-more Designer programming software (DM-PGMSW) from our website at http://automationdirect.com and launch the install procedure. If you already have Do-more Designer installed, you can just update to version 1.2 or newer to get T1H CPU support. The first screen that opens is the Welcome screen seen here. If there are previous versions of this software already installed, this screen will detail the version number of the software being replaced and the one being installed, click Next to continue. An alert window will appear requesting that all anti-virus software be disabled and also reminding the user that Administrative restrictions may exist.
The License Agreement window will be displayed next. Read over the agreement, select “I accept the terms of the license agreement” and click the Next button to continue. There is also the option to print the license agreement if desired. The print function will print the license agreement to a .pdf file and save it in the location you choose.
Do-more T1H Series PLC Hardware User Manual, 1st Edition, Rev. A - T1H-DM-M
1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D
1–7
Page 20
Chapter 1: Getting Started
1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D 1–8
Now the software will ask a little about you. Please fill in the information requested on the Customer Information screen and click Next to continue.
At this stage, the software will ask which type of install you would like to perform. The Select Type window seen below gives two options for installation type: Complete and Custom. Custom installation allows you to choose which program features to install, whereas Complete installation installs all of the program features available. The Complete installation is selected by default and is recommended for first-time users. Select the installation type desired and click the Next button to continue.
The next screen to appear is the Ready to Install the Program window. This window is an alert window, cautioning you that the program is about to be installed. If there are any changes that need to be made to the install settings do them now before continuing. To review or change any of the previous installation selections, click the Back button to return to the appropriate window and make the change. If no changes are necessary click the Install button to begin the installation. Do-more T1H Series PLC Hardware User Manual, 1st Edition, Rev. A - T1H-DM-M