Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of Do-more T1H Series PLC Hardware User Manual

Manual · AutomationDirect

Do-more T1H Series PLC Hardware User Manual

Manual168 pagesPDF 40 MB

Hardware user manual for the Do-more T1H Series PLC and Terminator I/O, with specifications for the T1K-08B(-1) I/O terminal base.

Download the PDF40 MB

Covers · 3 models

The models it covers

Summary

What is in it

AutomationDirect hardware user manual for the Do-more T1H Series PLC, which pairs the T1H CPU module with Terminator I/O modules. It walks through getting started with Do-more Designer software, then gives specifications for the CPU modules, the T1K-08B(-1) and T1K-16B(-1) I/O terminal bases and T1K power supplies, discrete, analog and specialty I/O modules, followed by installation and wiring guidelines and EU directives. The T1K-08B appears in the terminal base chapter with its wiring and environmental specifications.

Its parts

  1. Getting Started
  2. Do-more T1H Series PLC Overview
  3. Specifications - CPU Modules
  4. Specifications - Terminal Bases and Power Supplies
  5. Specifications - Discrete I/O Modules
  6. Specifications - Analog I/O Modules
  7. Specifications - Specialty Modules
  8. Installation and Wiring

From the manual

Key facts from this manual

Each line names its page in the PDF.

AutomationDirect hardware user manual for the Do-more T1H Series PLC, built from the T1H-DM1 or T1H-DM1E CPU and Terminator I/O. It covers the T1K-08B(-1) and T1K-16B(-1) I/O terminal bases, the T1K-01AC and T1K-01DC power supplies and the discrete, analog and specialty modules. It gives specifications, power budgeting, assembly and wiring guidance.

Read for this summary: pages 1, 46 to 48, 50 to 53, 62 to 68, 70, 131 to 132, 142 and 145 of 168.

Device
I/O terminal base for Terminator I/O modules in the Do-more T1H Series PLC; T1K-08B and T1K-08B-1 versions p. 62, 63
Terminal types
Terminator I/O bases come with screw clamp or spring clamp connectors p. 142
Screw torque
1.77-3.54 lb·in (0.2-0.4 N·m) for screw terminals; not applicable to spring clamps p. 142
Screwdriver
Screw terminals: 0.5 mm x 3.0 mm blade; spring clamps: push in with a 0.4 mm x 2 mm to 0.8 mm x 4 mm blade p. 62
Mounting
The I/O module presses into the base; the assembly snaps onto DIN rail p. 131
Hot swap
Not supported; remove system power before removing an I/O module from its base p. 132, 145
CPU ports
T1H-DM1: USB and RS-232; T1H-DM1E: USB, RS-232 and 10/100 Base-T Ethernet p. 48, 50, 53
AC power supply
T1K-01AC: 110/220 VAC (85-264 VAC) input; 5 VDC at 2.0 A plus 24 VDC auxiliary at 300 mA, or 1.5 A with 500 mA p. 64, 66
DC power supply
T1K-01DC: 12/24 VDC (10.8-26.4 VDC) input; 5 VDC at 2.0 A p. 64, 66
USB cables
USB Type A to B: USB-CBL-AB3 (3 ft), USB-CBL-AB6 (6 ft), USB-CBL-AB10 (10 ft), USB-CBL-AB15 (15 ft) p. 52
RS-232 port
RJ-12, 1200 to 115200 baud; cables D2-DSCBL, FA-CABKIT, EA-MG-PGM-CBL; FA-ISOCON converts to isolated RS-422/485 p. 52
Software
Do-more Designer V1.2 or newer p. 51
Expansion cable
T1K-10CBL base expansion cable p. 65
Discrete modules
15 discrete I/O modules: DC and AC inputs, DC, AC and relay outputs p. 70

What this manual walks you through

  • Checking which Terminator I/O components the Do-more T1H CPUs support p. 47
  • Choosing a CPU port for each communication protocol p. 48
  • Calculating the power budget for each power supply p. 66, 67, 68
  • Inserting I/O modules into bases and mounting on DIN rail p. 131
  • Removing I/O modules from the base p. 132
  • Wiring the I/O module bases p. 142
  • Selecting internal 24 VDC power for DC input modules p. 142
  • Following the I/O wiring checklist and output fusing p. 145

Good to know

  • Field device power may still be on the terminal block with system power off; check it before removing a wire. p. 142
  • Exceeding the power budget may make the system operate unpredictably. p. 66
  • A power supply is required in the leftmost position; each supply powers the modules to its right up to the next supply. p. 132
  • The CPU USB port is not compatible with older full speed USB devices. p. 52
  • With one Ethernet port, Ethernet I/O cannot sit on an isolated network while other Ethernet functions are used. p. 53

Questions this manual answers

What is the T1K-08B?

The manual lists the T1K-08B(-1) as an I/O terminal base for the Terminator I/O modules used in the Do-more T1H Series PLC. p. 62, 63

How do I put an I/O module into a Terminator I/O base?

Pull the base arm back, align the module slides with the base track, and press the module firmly into the base. p. 131

Can Terminator I/O modules be hot swapped on the Do-more T1H?

No. The T1H Series PLC does not support hot swap, so remove system power before removing a module from its base. p. 132, 145

How much 24 VDC can the T1K-01AC power supply provide?

300 mA from its auxiliary 24 VDC supply, or 500 mA if the 5 VDC output is lowered to 1.5 A. p. 64, 66

What cable programs the Do-more T1H CPU over USB?

A USB Type A to Type B cable, such as USB-CBL-AB3, USB-CBL-AB6, USB-CBL-AB10 or USB-CBL-AB15. p. 52

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. T1H-DM-M Manual1
  2. Warning3
  3. Manual History7
    1. Chapter 1: Getting Started9
    2. Chapter 2: Do-more T1H Series PLC Overview10
    3. Chapter 3: Specifications - CPU Modules10
    4. Chapter 4: Specifications - Terminal Bases and Power Supplies10
    5. Chapter 5: Specifications - Discrete I/O Modules10
    6. Chapter 6: Specifications - Analog I/O Modules10
    7. Chapter 7: Specifications - Specialty Modules11
    8. Chapter 8: Installation and Wiring11
    9. Appendix A: European Union Directives (CE)11
  4. Chapter 1. Getting Started13
    1. Introduction14
    2. Conventions Used15
    3. Before You Begin16
    4. Step 1: Install Do-more Designer Software18
    5. Step 2: Launch Do-more Designer Software22
    6. Step 3: Install Hardware23
    7. Step 4: Apply Power to the PLC25
    8. Step 5: Establish Communication25
    9. Step 6: Verify Hardware Configuration31
    10. Step 7: Create a Ladder Logic Program36
    11. Step 8: Save a Project41
    12. Step 9: Write Project to the Do-more T1H Series PLC41
    13. Step 10: Testing Project Using Data View42
    14. Accessing the Help File44
  5. Chapter 2. Do-more PLC Hardware Overview45
    1. Do-more T1H Series PLC Overview46
  6. Chapter 3. Specifications - CPU Modules49
    1. CPU Specifications50
    2. Communications Ports Specifications52
    3. Ethernet I/O54
    4. Status Indicators56
    5. Mode Switch Functions56
    6. DIP Switch Specifications57
    7. Battery Replacement59
  7. Chapter 4. Specifications - Terminal Bases and Power Supplies61
    1. T1K-08B(-1) I/O Terminal Base62
45 more lines, from page 62 on
  1. T1K-16B(-1) I/O Terminal Base62
    1. T1K-01AC, T1K-01DC Power Supply64
    2. Calculating the Power Budget66
  2. Chapter 5. Specifications - Discrete I/O Modules69
    1. Discrete I/O Modules Overview70
    2. T1K-08ND3 - DC Input71
    3. T1K-16ND3 - DC Input73
    4. T1K-08NA-1 - AC Input75
    5. T1K-16NA-1 - AC Input76
    6. T1K-08TD1 - DC Output77
    7. T1K-16TD1 - DC Output78
    8. T1K-08TD2-1 - DC Output79
    9. T1K-16TD2-1 - DC Output80
    10. T1H-08TDS - Isolated DC Output81
    11. T1K-08TA - AC Output82
    12. T1K-16TA - AC Output83
    13. T1K-08TAS - Isolated AC Output84
    14. T1K-08TR - Relay Output85
    15. T1K-16TR - Relay Output86
    16. T1K-08TRS - Isolated Relay Output87
    17. Analog I/O Modules Overview90
    18. T1F-08AD-1 - 8 Channel Analog Current Input94
    19. T1F-08AD-2 - 8 Channel Analog Voltage Input95
    20. T1F-16AD-1 - 16 Channel Analog Current Input96
    21. T1F-16AD-2 - 16 Channel Analog Voltage Input97
    22. T1F-16RTD - 16 Channel RTD Input98
    23. T1F-16TMST - 16 Channel Thermistor Input100
    24. T1F-14THM - 14 Channel Thermocouple Input102
    25. T1F-08DA-1 - 8 Channel Analog Current Output105
    26. T1F-08DA-2 - 8 Channel Analog Voltage Output106
    27. T1F-16DA-1 - 16 Channel Analog Current Output107
    28. T1F-16DA-2 - 16 Channel Analog Voltage Output108
    29. T1F-8AD4DA-1 - 8 Channel Analog Current Input / 4 Channel Analog Current Output109
    30. T1F-8AD4DA-2 - 8 Channel Analog Voltage Input / 4 Channel Analog Voltage Output111
    31. Specialty Modules Overview114
    32. T1H-CTRIO115
  3. Chapter 8. Installation and Wiring123
    1. Safety Guidelines124
    2. Mounting Guidelines127
    3. Assembling the Components131
    4. Multiple Power Supplies / Local Expansion Configurations133
    5. Wiring Guidelines141
    6. I/O Wiring Strategies146
    7. European Union (EU) Directives160
    8. Basic EMC Installation Guidelines163

From the PDF’s own bookmarks.

The whole text · 20 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 61-6
  2. Pages 7 to 127-12
  3. Chapter 1. Getting Started, pages 13 to 2013-20
  4. Chapter 1. Getting Started, pages 21 to 2821-28
  5. Chapter 1. Getting Started, pages 29 to 3629-36
  6. Chapter 1. Getting Started, pages 37 to 4437-44
  7. Chapter 2. Do-more PLC Hardware Overview45-48
  8. Chapter 3. Specifications - CPU Modules49-60
  9. Chapter 4. Specifications - Terminal Bases and Power Supplies61-68
  10. Chapter 5. Specifications - Discrete I/O Modules, pages 69 to 7769-77
  11. Chapter 5. Specifications - Discrete I/O Modules, pages 78 to 8678-86
  12. Chapter 5. Specifications - Discrete I/O Modules, pages 87 to 9587-95
  13. Chapter 5. Specifications - Discrete I/O Modules, pages 96 to 10496-104
  14. Chapter 5. Specifications - Discrete I/O Modules, pages 105 to 113105-113
  15. Chapter 5. Specifications - Discrete I/O Modules, pages 114 to 122114-122
  16. Chapter 8. Installation and Wiring, pages 123 to 132123-132
  17. Chapter 8. Installation and Wiring, pages 133 to 142133-142
  18. Chapter 8. Installation and Wiring, pages 143 to 152143-152
  19. Chapter 8. Installation and Wiring, pages 153 to 162153-162
  20. Chapter 8. Installation and Wiring, pages 163 to 168163-168

The file

Revision and size

Part no.T1H-DM-M
Revision1st Edition, Rev. A, 10/16
PublisherAutomationDirect
Pages168
PDF40 MB
TextText from the PDF itself; pages 1 and 113 are scans, read by OCR, which may hold reading errors.
T1H-DM-M

The first pages · 3 of 168

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 168
Page 2
Page 2of 168
Page 3
Page 3of 168

More documents · 1

For the same models