Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual ยท part 1 of 4

Model LC4/5 "PLUS" User's Manual, pages 1 to 10

Pages 1 to 10 of 40

The original document is the PDF (234 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the AutoMotion AT4CP10200

Page 1

MODEL LC4/5 "PLUS" USER'S MANUAL

This manual covers the use and maintenance of the model LC4/5 "PLUS" series Brushless DC Motor Control product family. Included in this manual are the following model numbers:

LC4A-(P) LC5A-(P) LC4B-(P) LC5B-(P) LC4C-(P) LC5C-(P) LC4D-(P) ............... This document applies to serial numbers beginning after XXXXX0894. If you require further assistance, please call or write:

AUTOMOTION INCORPORATEDtm P.O. Box 7746 Ann Arbor, Michigan USA 48107 (313) 662-7771 FAX # (313) 662-3707 READ ENTIRE MANUAL FIRST. DO NOT RETURN PRODUCTS WITHOUT PRIOR AUTHORIZATION DIRECT FROM AUTOMOTION. Document Creation Date: May 1, 1996. Document Revision 0 Release Date: May 1, 1996. Files: LC45UM & LC45TC Document Control# A10505 Copyright (c) 1996 Automotion Incorporated - All Rights Reserved.

Page 2

SAFETY PRECAUTIONS Read this page and section 1.0 before using the LC4/5 Drive To operate your control successfully, these minimum safety precautions MUST be followed to insure proper performance without injury to the operator and damage to motor or control. FAILURE TO OBSERVE THESE SAFETY PRECAUTIONS COULD RESULT IN SERIOUS BODILY INJURY, INCLUDING DEATH IN EXTREME CASES. 1.

DO NOT touch any of the terminals numbered 16, 17, 18, 19 or 20 when power is applied. All of these terminals are located on connector P2. WARNING! The voltages at these connector pins are dangerous and can produce an electric shock. Bare wires from adjacent connector pins must never be allowed to touch one another. P2 pin 15 must be connected to an external earth ground.

2.

Always operate the control within the prescribed input voltage limits.

3.

Each model has dangerous voltages present on the circuit boards and stores a high voltage charge after being disconnected from the AC power source. DO NOT REMOVE THE COVER IF ONE IS IN PLACE. DO NOT ATTEMPT TO SERVICE THIS PRODUCT IF A PROBLEM OCCURS.

4.

Be cautious when using the control in a 4 Quadrant mode. Instant direction changes can damage the amplifier. Read manual carefully for 4 quadrant limitations.

5.

Do not parallel multiple motors off of the same control.

6.

Under no circumstances must a phase output from the control be connected to anything other than a passive inductive load, such as a motor. See manual for minimum inductance requirements.

7.

The packaged control is designed for use in a NEMA type 1 service. Direct contact with liquids or corrosive chemicals should be avoided. Use in a dust free environment.

8.

Excessive speed can destroy some DC brushless motors and damage user equipment. Check the motor manufacturer's specifications to ensure the maximum current and voltage output for your control model does not exceed the motor limitations.

9.

Do not remove the connectors P1 or P2 from the control while the motor is operating. DO NOT plug connector P2 into the control when wired to live AC power.

10.

Read Automotion's Life support Policy, Section 22 for application limitations.

11.

Never mount this product in the vicinity of combustible materials. Never use this product in an atmosphere of potentially explosive or highly combustible gases or particles.

12.

Models with an external shunt resistor require special installation procedures. An external shunt can become either a shock or fire hazard if not properly mounted and used. Consult Automotion for details.

Page 3

Automotion, Inc. LC4/5 User's Manual

1.0 boards and use large electrolytic capacitors which store a high voltage charge after the unit is disconnected from the power supply. Do not attempt to service these units if a problem occurs or remove the cover! First consult section 18.0, ``In Case of Trouble.'' If this fails to solve the problem, call AUTOMOTION.

Safety Precautions: READ THIS ENTIRE SECTION BEFORE ATTEMPTING TO USE THE LC4/5! To operate the LC4/5 successfully, these minimum safety precautions MUST be followed to insure proper performance with minimal risk of injury to the operator and damage to motor or LC4/5 control.

4. Care must be exercised when using the LC4/5 control in a 4 Quadrant mode. Instant direction changes under these conditions can cause electrical damage to the amplifier. Before using the LC4/5 in this mode, read section 14.0, ``Reversing the Motor, 4 Quadrant Operation.''

Failure to observe these safety precautions could result in serious bodily injury, including death in extreme cases, and will void the warranty.

5. The LC4/5 will control only one brushless DC motor at a time. Do not parallel additional motors off of the same LC4/5 control.

Automotion's products are not authorized for use as critical components in life support devices or systems without the express written approval of the President of Automotion Incorporated.

6. Under no circumstances must a phase output from the LC4/5 control be connected to anything other than a passive inductive motor load. Other loads could cause immediate damage to the LC4/5 control.

1. Do not touch any of the output terminals numbered 16,17, 18, 19, or 20 when power is applied. The voltages at these terminals are dangerous and can produce an electrical shock and cause lethal personal injury. The wires connected there should never have too much insulation removed allowing bare wire to be exposed beyond the terminal block. Bare wires from adjacent terminals must never be allowed to touch one another when power is applied to the LC4/5 control. Ground terminal number 15 MUST always be connected to an appropriate external EARTH power ground during use of the LC4/5 control.

7. The LC4/5 packaged control is designed for use in a NEMA type 1 service. The LC4/5 open frame control requires additional protection. Proper ventilation and mounting is required for reliable performance. Direct contact with liquids, corrosive chemicals, or corrosive gases must be avoided. The operating environment must be clean, dry and free from dust. Special packaging will be needed for the LC4/5 if these conditions are violated. See Section 10.0 "Installation: Mechanical," for more details. 8. Check the motor's peak RPM rating. Excessive speed can destroy some DC brushless motors and damage user equipment. In addition, check the motor manufacturer's specifications to make certain the maximum current limited output for your LC4/5 model will not risk permanent demagnetization of the motor. If the current is too high, see Section 17.0, ``Setting the Maximum Current Limited Output,'' for details on how the upper limit on the LC4/5

2. Always operate the LC4/5 control within the prescribed voltage limits. To attempt to operate outside these bounds may result in damage to the LC4/5 control. See section 3.3 3. All LC4/5 models have dangerous voltages present on the internal circuit

2

Page 4

Automotion, Inc. LC4/5 User's Manual

2.0 may be reduced to a safe level to match the motor's limits.

Unpacking and Repacking: When your package arrives, inspect the shipping box carefully, and save ALL packing materials. Contact the carrier promptly if damage is discovered. Your LC4/5 has arrived carefully packaged from AUTOMOTION in a static proof bag. As you unseal this bag inspect the contents carefully. There should not be any loose or damaged parts in this bag. While unpacking, if you discover any loose or damaged parts, notify AUTOMOTION within two working days.

9. Do not remove the connectors P1 or P2 from the LC4/5 while the motor is operating. This can cause electrical arcing which can damage the connector pins. DO NOT plug connector P2 into the LC4/5 frame when live AC power is wired into the mating connector body. 10. Application limitations for the LC4/5 product are presented in Section 22.0 "Life Support Policy."

Compare the packing slip against all items included in the box. Any shortages or other inspection problems should be reported immediately. Never attempt to operate or power-up the LC4/5 if there is any visible external damage or if it sounds as though there are loose materials inside the chassis.

11. Never mount this product in the vicinity of combustible materials. Never use this product in an atmosphere of potentially explosive or highly combustible gas and/or dust. The LC4/5 should always be located inside an enclosure which is both intrinsically fire safe and shock safe. This may necessitate the need for safety interlocks on the outside enclosure to disconnect all power whenever service is performed.

AUTOMOTION recommends that all packing materials be saved in case the LC4/5 ever needs to be shipped again. Always place the LC4/5 in the same static proof bag used in the original shipment. Abundant filler material should always be placed around the LC4/5 bag so that it cannot shift inside the box.

12. If the LC4/5 is equipped with provisions for an optional external shunt resistor, then special precautions will need to be followed. An external shunt resistor must be mounted within its own enclosure which must be designed to prevent any fire hazard should the resistor overheat for any reason. User access to this resistor must be restricted to prevent any possibility of a shock or burn hazard.

Always insure your shipment for the proper replacement value of its contents. AUTOMOTION will not assume responsibility for any returned goods which have been damaged outside of our factory because of improper packaging or handling. All goods shipped to AUTOMOTION must have prior return authorization and be shipped FREIGHT PREPAID.

13. When applications permit conditions in which excessive motor speed will cause unsafe operation, external provisions may be required for user protection. This product should not be depended upon to prevent excess motor speed in which user safety may be compromised.

3

Page 5

Automotion, Inc. LC4/5 User's Manual

3.0

LC4/5 Product Family Specifications:

3.1

Drive type:

3.3

LC4- 95 to 132 volts AC-RMS, single phase, 50/60 Hz. 145 VAC peak for 1 sec. Automatic over/under voltage shutdown employed. AC line inputs are MOV protected.

2 Quadrant, six step, 3 Phase, Full Wave PWM controlled output.

3.2

LC5- 190 to 245 volts AC-RMS, single phase, 50/60 Hz. 260 VAC peak for 1 sec. Automatic over/under voltage shutdown employed. AC line inputs are MOV protected.

Maximum Current Limited Output: LC4A

LC4B

LC4C

3.25

Amps RMS continuous.

4.5

Amps RMS peak* limited.

5.7

Amps RMS continuous.

8.0

Amps peak* limited.

10.7

Amps RMS continuous.

15.0

Amps peak* limited.

3.4

LC5A

LC5B

LC5C

14.2

Amps RMS continuous.

20.0

Amps RMS peak* limited.

3.25

Amps RMS continuous.

4.5

Amps peak* limited.

7.1

Amps RMS continuous.

10.0

Amps peak* limited.

10.7

Amps RMS continuous.

15.0

Amps peak* limited.

PWM Operating Frequency: Approximately 18 KHz.

3.5

Operating Temperature Range: 0 to +50 degrees Celsius. Automatic over temperature shutdown employed at +50 degrees Celsius on heat sink. Consult Automotion if a larger range is required.

3.6 LC4D

Operational Voltage Supply Range:

Storage Temperature Range: -20 to +85 degrees Celsius.

3.7

Operating Humidity Range: 5 to 95% RH non-condensing.

3.8

Output Voltage to Motor: LC4- Nominally +160 volts chopped DC, phase-to-phase. This is based upon a supply voltage of 115 volts AC-RMS, at full-rated continuous output amps. LC5- Nominally +320 volts chopped DC, phase-to-phase. This is based upon a supply voltage of 230 volts AC-RMS, at full-rated continuous output amps.

* Defined as the peak of a six step waveform. See ``Reversing the Motor, 4 Quadrant Operation'' for precautionary details.

4

Page 6

Automotion, Inc. LC4/5 User's Manual

3.9

Product Size:

3.13

User selectable for either 60 or 120 electrical degrees of signal phase displacement. See section 7.0, ``Motor Requirements.''

Packaged Unit: Height 9.25 inches (23.5 cm) Width 5.4 inches (13.7 cm) Depth 8.5 inches (21.6 cm) Weight 6.25 lb. max (2.81 Kg) ________________________________

3.14

3.10

10.5 3.5 6.25 3.2 inches (26.7 cm) inches (8.9 cm) inches (15.9 cm) lb. max (1.45 Kg)

3.15

Heat Sink Cooling:

Motor Compatibility: Any three phase WYE or DELTA wound brushless DC motor designed to operate with 160 volts DC power and possessing a minimum winding inductance of 150 micro Henries or greater and a minimum winding electrical time constant of 0.5 msec. See Section 7.0, ``Motor Requirements'' for more information.

External forced air cooling may be necessary when prolonged high amperage duty cycles are used and/or high ambient air temperature exists. The LC4/5 will automatically shutdown whenever the heat sink temperature reaches approximately 50 degrees Celsius. To restart the motor, toggle the Start/Stop input after the heat sink has cooled.

3.11

Additional Controls: Start/stop, forward/reverse, dynamic brake, external current limit trip input, external signal input for closed loop speed control. An optional current signal output is available, but must be configured at the factory. See the Table of Contents for further information.

Open Frame Unit: Height Width Depth Weight

Commutation Code:

3.16

Logic Control: All logic I/O terminals numbered 1 through 14 are electrically isolated from the AC power. External logic interfacing should be implemented using TTL outputs. Simple toggle switches may also be used. The maximum input voltage should not exceed +24 volts DC. See appendix for suggested wiring hook-ups.

Speed Control: Stock model is equipped for both external 4 quadrant speed control or Closed Loop, 2 quadrant internal speed regulation. The external speed control may be provided by means of either an analog signal for 0 to +10 volts, or an external PWM source. See the appropriate sections in this manual for further details on each of these capabilities. An optional +/- 10 volt analog signal input card is available. See Section 19.0, "Optional Equipment."

3.17

Dynamic Braking Limitations: Some limitations exist in the use of the dynamic brake. Dynamic Brake Limitations: Maximum 2% Duty Cycle. 10 watts continuous/ 650 Watts intermittent. Please read Section 15.0, ``Dynamic Braking the Motor,'' if you intend to use this feature.

3 .12 Commutation Control: 3.18

Normally provided by three rotor positional sensors located within the brushless DC motor. These sensors may be either of the Hall variety or optical in nature. See section 7.0, ``Motor Requirements.''

Full Short Circuit Protection: The LC4/5 is protected from damage due to a momentary direct short circuit to ground, a short to the AC power supply rails, or a phase-to-phase short. Inadvertent shorts in the motor or motor phase lines may result in the drive tripping off line

5

Page 7

Automotion, Inc. LC4/5 User's Manual and the annunciation of the fault. The fault may be cleared and the drive restarted without damage (once the short has been removed), by resetting the enable/disable line. Frequent short circuits may eventually damage the drive.

3.19

If the LC4/5 is subject to frequent power-up conditions, a different fuse may need to be specified.

4.0

The following steps should be followed in the order shown to complete the proper electrical installation. Always cut and strip only enough insulation off of connecting wires to mate with the LC4/5 terminals. Do not leave bare wires exposed beyond the edge of the terminal block. This would create a potential hazard to the operator and the system from short circuits between adjacent terminals. NEVER MAKE ELECTRICAL CONNECTIONS OR WIRING ADJUSTMENTS WITH LIVE POWER APPLIED TO THE LC4/5 CONTROL. Please refer to FIGURE 1 for information when performing the following installation steps.

1500 VAC HiPot Tested: The LC4/5 is tested at the factory for dielectric strength between incoming AC power and user SELV interface circuits. It is also tested for dielectric strength between incoming AC power and chassis frame ground. The HiPot test level used is 1500 VAC between SELV circuits on connector P1 and incoming AC power on connector P2. A HiPot test level of 1500 VAC is used between the chassis frame ground and incoming AC power on connector P2.

3.20

Packaging: Models with the subscript ``P'' are packaged in a NEMA 1 type ventilated enclosure. All others are open frame. DO NOT PLACE ANY LC4/5 IN CONTACT WITH LIQUIDS, ELECTRICALLY CONDUCTIVE MATERIALS, OR CORROSIVE CHEMICALS OR ALLOW FOREIGN MATERIALS TO FALL INTO THE LC4/5.If the LC4/5 must be used in an environment which violates these conditions, contact AUTOMOTION for special packaging recommendations.

3.21

Quick-Start Set up:

4.1

Step One: Wire motor phases to proper terminals on the LC4/5 control. Use the wire sizes recommended in Section 6.0, ``Power Supply Requirements.'' The three phase wires should be twisted together with approximately six twists per foot (0.3 meters).

4.2

Step Two: Wire the rotor positional sensors into the control. In a typical installation, there will be 5 wires serving the sensor assembly. They are: S1, S2, S3, + low voltage DC power (i.e., Terminal #4, +12 volt DC), and LOGIC GROUND (i.e., Terminal #5).

Fuse Sizes: When replacing a fuse, always use properly rated devices. For the LC4A, use only a LITTELFUSE #314007 or equivalent. For the LC4B, use only a LITTELFUSE #314010 or equivalent. For the LC4C, use only a LITTELFUSE #314020 or equivalent. For the LC4D, use only a LITTELFUSE #314025 or equivalent.

Light gauge wire may be used, such as 24 AWG. When the distance between the motor and the control exceeds 6 feet (1.8 meters), AUTOMOTION recommends using a shielded cable for the sensor wires. A single shield covering the entire bundle should be sufficient with the shield terminated ONLY at Terminal #5 of the LC4/5 control. The motor end of the shield should be left open. If unshielded wire is used, twist these five wires together with approximately six twists per foot (0.3 meters).

For the LC5A, use only a LITTELFUSE #314010 or equivalent. For the LC5B, use only a LITTELFUSE #314015 or equivalent . For the LC5C, use only a LITTELFUSE #314020 or equivalent.

6

Page 8

Automotion, Inc. LC4/5 User's Manual

LC4/5 BASIC WIRING DETAILS

FIGURE 1 NOTES!

LOGIC GROUND and chassis ground are NOT common with each other and normally are kept separate from each other externally. Also, be aware of restrictions involving the use of the Forward/Reverse at high RPM's. SEE THE MANUAL FOR ADDITIONAL DETAILS!! Shown above is a simple open loop speed control installation.

7

Page 9

Automotion, Inc. LC4/5 User's Manual

4.3

Step Three: Determine the proper commutation signal phase shift required for your motor (i.e., 60 or 120 electrical degrees) and place the jumper in JUMPER GROUP 2 located on the bottom of the LC4/5 in the proper position as described below. See FIGURE 4 or FIGURE 5 for placement details. Units are normally shipped in the 120 degree mode, unless otherwise indicated. Reference Section 7.0, ``Motor Requirements'' for more information.

4.4

4.6

With the external AC 50/60 Hz, feed power temporarily DISCONNECTED, wire the feeder block or the power cord into the LC4/5 control at connector J2. Use the wire sizes recommended in Section 6.0, ``Power Supply Requirements.'' NEVER MAKE POWER CONNECTIONS TO THE LC4/5 WITH LIVE AC POWER.

4.7

Decide whether you will be using either open or closed loop speed control. If open loop is required, use Terminal #9 as the input for this 0 to + 10 volt analog signal, which is referenced to LOGIC GROUND (i.e., Terminal #5). A +10 volt DC signal at Terminal #9 will run the motor at maximum current limited RPMs. Please note that for open loop speed control a simple external potentiometer with a minimum resistance of 10K ohms may be used to control your motor RPM's. See section 12.0, "Running the Motor With the LC4/5 Control: CLOSED LOOP" for details.

4.5

Step Seven: Before operating the LC4/5 control for the first time, make sure that all logic control inputs are wired correctly and that the current drain out of Terminal #4 will be no more than 50 mA. Whenever AC power is first applied after a brownout or after a momentary power interruption, the LC4/5 will require a power-up reset. This is done by toggling the Start/Stop input port (i.e., Terminal #6) from OFF to ON. Please note that it is normal for the ``Power/OT Fault'' and LED to be lit at power-up or after a power interruption. Always check the setting of the front panel trim pots. Improper adjustment can cause needless delays and trouble. Review Section 5.0, ``Last Minute Check List'' before operating the LC4/5 for the first time.

Step Four:

Your LC4/5 is designed to operate in several different speed control modes. These include: Open loop, 1, 2, or 4 quadrant speed control using a 0 to +10 volt analog signal; optional +/10 volt input; internal single quadrant closed loop speed control with the tach signal provided by the commutation sensors; internal single quadrant closed loop speed control with the tach signal provided by an external encoder input; external PWM control.

Step Six:

5.0

Last Minute Check List: (read before operating the LC4/5 for the first time) Have you connected your AC power cables correctly? ______ yes______ no Are all connectors snapped into place?

Step Five:

______ yes______ no If you use Forward/Reverse or Dynamic Brake controls, these ports may be toggled by either a simple SPDT switch, or by TTL signal outputs from an external electronic based control. If external TTL signals are used, the common return path must be connected to terminal #5 (LOGIC GROUND).

Have you checked your motor phase output connections and all other wiring to make certain there are no shorts? ______ yes______ no

8

Page 10

Automotion, Inc. LC4/5 User's Manual

Will your power source supply the correct AC voltage?

MOV protected for very short ``soft'' line transients above 145 VAC.

______ yes______ no

For the LC5 models,the voltage range must be between 200 and 245 VAC-RMS or an automatic shutdown of the control may occur. Any continuous supplied voltage over 245 VAC-RMS may cause damage to the LC5 control. The AC line inputs for the LC5 are MOV protected for very short ``soft'' line transients above 260 VAC.

(Remember to bring the motor speed up gradually the first time you operate the LC4/5). Have you adjusted the user accessible trim pots correctly? ______ yes______ no

Consult AUTOMOTION for limitations. If you are NOT using input Terminals #10 and/or #11, have you connected them to Terminal #5 (LOGIC GROUND)?

6.2

Voltage fluctuations on the AC supply line may adversely affect the maximum RPM level attainable by your motor and speed stability, especially when operating in an open loop mode.

______ yes______ no Have you read through this manual entirely including the SAFETY PRECAUTIONS? ______ yes______ no

6.3

If you answer ``NO'' to any of the preceding questions, make the necessary corrections before proceeding.

Power Supply Requirements:

6.1

Power Source:

Wire Size: AUTOMOTION recommends that a minimum wire size of 16 AWG be used for connecting the LC4/5 to both the AC power source and to the three phases of the motor. Use 14 AWG wire for the motor phase connections and the AC power connections if the individual wire lengths exceed 6 feet (1.8 meters).

Please note, upon power up, the drive default condition for Terminal #6 start/stop is ``Stop''. Start/stop input must be toggled OFF and ON to start the motor.

6.0

AC Voltage Fluctuation:

6.4

Cable Requirements The phase output cable should have a maximum distributed capacitance of 100 pF/ft (328 pF/meter) up to a total of 1000 pF.

The power source used with the LC4/5 product family must be a nominal 115 volts for the LC4 or a nominal 208/220 volts for the LC5 models. This source must be single phase AC service with a nominal line frequency of 50/60 Hz, +/- 3%, and the amperage capacity for the supply circuit must be rated at least 10 amperes above the continuous output rating for your particular LC4/5 model.

Total capacitance being the sum of phase to phase and phase to ground (shield) capacitance. If cable losses are higher, compensating line inductors may be required. Contact Automotion for application assistance.

6.5

Fuses: The LC4/5 product line is internally fused. Should the fuse blow, always determine why this occurred before attempting to operate the LC4/5 again. See Section 3.21 for fuse sizes.

For the LC4 models, the voltage range must be between 95 and 132 VAC-RMS or an automatic shutdown of the control may occur. Any continuous supplied voltage over 132 VAC-RMS may cause damage to the LC4 control. The AC line inputs for the LC4 are

9