The text of a manual · part 2 of 4
Model LC4/5 "PLUS" User's Manual, pages 11 to 20
Pages 11 to 20 of 40
The original document is the PDF (234 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the AutoMotion AT4CP10200
Page 11
Automotion, Inc. LC4/5 User's Manual
6.6
Line Filter:
7.3
Phase Shift Selection:
In some noise sensitive or noisy systems, it may be desirable to place a line filter between the LC4/5 AC power input terminals and AC power source. Such devices are commercially available. Ask AUTOMOTION for recommendations.
Before operating, configure the LC4/5 control to match the phase shift between the signals supplied by the three rotor positional sensors. You can use the LC4/5 with either 60 or 120 electrical degree phase shift. See FIGURE 3.
7.0
Motor Requirements:
7.1
Commutation Feedback:
To program the LC4/5, see FIGURE 4 or FIGURE 5 for an illustration of where to locate the proper jumper pins on the bottom of the chassis. All units are shipped from the factory set for 120 electrical degrees unless otherwise noted.
The LC4/5 control is designed to operate with a three phase brushless DC motor. This motor must employ either three Hall or optical sensors for rotor positional feedback. These sensors must be capable of operation off of the +12 VDC supply provided by the LC4/5. The signal outputs of these sensors may use either passive or active pull-ups. The LC4/5 DOES provide internal pull-ups. So, if the sensors used by your motor do not provide active pull-ups, then passive external pull-ups of three 10K Ohm, 1/4 Watt resistors are optional, though recommended. See FIGURE 2 for details. For distances less than six feet (1.8 meters), twist the sensor wires and sensor power wires together with approximately six twists per foot (0.3 Meter). If the distance between the motor and control exceeds six feet (1.8 meters), use shielded wire for the commutation sensor signal lines and the commutation sensor power lines. DO NOT co-mingle commutation sensor signal lines with motor phase lines.
7.2
Electrical Characteristics: The brushless DC motor should be three phase with either a WYE or DELTA wound stator. The motor inductance should not be less than 150 micro Henries phase-to-phase at full amperage. The total number of poles on the rotor assembly does not affect the performance of the LC4/5 control except at very high RPM's. For the LC4 model, the motor should operate with a DC voltage power source at a minimum of +200 volts. For the LC5 model, the motor should operate with a DC voltage power source at a minimum of +400 volts. Motors should also pass a HiPot test of 1500VAC or higher between all phase lines and frame ground, and also between all phase lines and the commutation sensors.
10
*
To use the LC4/5 control with 60 electrical degree signal phase shift, place the Group 2 jumper in position ``B''.
*
To use the LC4/5 control with 120 electrical degree signal phase shift, place the Group 2 jumper in position ``A''.
Please note that the three rotor positional sensor signals coming into the LC4/5 from your motor must be square waves. When the motor is running at a constant velocity, these signals should exhibit a 50% duty cycle. The bottom of this page left intentionally blank.
Page 12
Automotion, Inc. LC4/5 User's Manual
Typical Hall Sensor Interface (Must be duplicated for each of the three signal inputs).
FIGURE 2
11
Page 13
Automotion, Inc. LC4/5 User's Manual
OPTIONS FOR COMMUTATION SIGNAL PHASE RELATIONSHIPS
NOTE: Each commutation signal has a balanced 50% duty cycle when the motor is running at a constant velocity.
FIGURE 3
12
Page 14
Automotion, Inc. LC4/5 User's Manual
FIGURE 4 PACKAGED LC4/5
13
Page 15
Automotion, Inc. LC4/5 User's Manual
FIGURE 5 OPEN FRAME LC4/5
14
Page 16
Automotion, Inc. LC4/5 User's Manual
8.0
External Shunt Resistor:
8.2
8.1
Shunt Requirement For Regenerative Braking: During rapid deceleration of the motor, power regeneration occurs. This causes kinetic energy to be returned to the LC4/5 control. For small inertial loads this may not be a problem, but for larger loads this returned energy must be dissipated by the control. The amount of energy return will depend upon both the rate of motor deceleration plus the size of the motor load.
AUTOMOTION recommends that certain safety precautions be followed in keeping with good engineering practice when using an external shunt resistor. In particular the following considerations are of importance: ·Selection of a properly sized resistor. ·Correct location and mounting for this external resistor. ·Correct wiring for this resistor to the Automotion brushless drive.
8.3
The LC4/5 control may be purchased with the option to use an external shunt resistor. This is usually a user supplied part. It is absolutely essential that this shunt resistor be properly sized and protected. AUTOMOTION will assist the user in the selection of this part when requested.
If no external shunt resistor is installed the user must understand that excess regeneration may cause nuisance trips. While this occurrence will not damage the control, it will disrupt the normal operation of the motor. Consequently, it is necessary for the external shunt resistor to be properly sized. See Section 8.3 for advice.
15
Selection of an External Shunt Resistor Value: The duty cycle for an external shunt resistor is application dependent. As such it helps to estimate just how much kinetic energy is stored in the motor and its load when deceleration begins. It is this kinetic energy which transfers back to the drive whenever a deceleration cycle begins.
The user is also burdened with the responsibility to make the installation of this external shunt resistor both fire safe and shock safe. Should any failure cause this resistor to overheat or cause its electrical cable to fail, the user must provide an intrinsically safe environment for this part so that no fire hazard can occur. A well designed heat shield is a user requirement for this part. This shield must also serve the purpose of preventing any possibility for a shock or burn hazard. AUTOMOTION does not recommend that this resistor be placed in the vicinity of either combustible or explosive materials and/or gases.
Shunt Safety Precautions:
AUTOMOTION recommends using the AUTOMOTION Field Application Bulletin No. 101-0195 for more selection details. AUTOMOTION DOES NOT recommend the use of a shunt resistor with less than a 50 Watt rating for any application. Consult AUTOMOTION if you wish to violate this guideline.
8.4
Location and Mounting of the External Shunt Resistor: The shunt resistor is a heat producing element powered from high voltage electricity. Consequently the user must follow several common sense safety guidelines to avoid possible problems later. The following is a list of suggested methods for mounting the external shunt resistor:
Page 17
Automotion, Inc. LC4/5 User's Manual
· DO NOT mount the shunt in the proximity of flammable materials. It is suggested that it be mounted only upon a metal surface, such as steel. It is also suggested that if it is to be installed in an enclosure, then this enclosure be made out of nonflammable metal materials with flow through air ventilation.
Temperature limiting devices are available to aid in the removal of the power source from the shunt resistor in the event it begins to overheat for any reason. However, they are not a substitute for making the basic installation fire proof. The simplest way to limit the heat concentration at the shunt resistor is to use the highest ohmic value resistor(s)possible plus higher wattage capacity in every application. This will help to keep shunt resistor surface temperature as low as possible under all circumstances. Worst case testing is always required to insure safe performance at all times.
· DO NOT use the shunt in an explosive atmosphere. ·DO NOT use the shunt in a location where it may be exposed to humidity condensation or other liquids. · Always locate the shunt in a location where it will remain clean and dry. · The shunt is activated by potentially lethal voltages. Mount the shunt someplace where it will not expose the user or service personnel to a shock hazard. A 115 VAC sourced drive can deliver voltages between 200 and 250 peak volts to the shunt. A 208/230 VAC sourced drive can deliver voltages between 400 and 450 peak volts to the shunt. · Always locate the shunt resistor in a location where it has space for ventilation. DO NOT locate in a closed space without free air movement. The following formulas are an indication of the maximum continuous wattage developed across the shunt when whenever it is ON. We suggest you design your installation to be fire and shock safe with this information in mind. For a 115 VAC sourced drive: Maximum wattage = (34150) / (Shunt resistance in Ohms) For a 208/230 VAC sourced drive: Maximum wattage = (132500) / (Shunt resistance in Ohms)
16
8.5
Suggested Wiring Methods for the External Shunt Resistor : At the user's option, a temperature sensitive fuse or switch can be used in conjunction with the external shunt resistor. The function of this device is to limit the temperature rise of the shunt resistor should it ever overheat. The following devices have been tried by Automotion and show merit in this purpose. 1. Elmwood part #JD090-V231. 2. Therm-O-Disc part #G5A01077C. 3. RCD Components fusible resistor #TF04D/.25 Ohm/±5% Tol. 4. Bussman heat limiter fuse part #TGC. Devices 1 and 2 are suitable for application as shown in FIGURE 6 ONLY! All of these listed devices are suitable for application as shown in FIGURE 7. Each part has a slightly different threshold temperature for opening. Check the manufacturers data sheet carefully before use. Any temperature sensing device should be a non-resettable type. The use of any temperature limiting device is not intended to substitute for any safety precautions previously stated.
Page 18
Automotion, Inc. LC4/5 User's Manual
AC POWER
Y)
AC POWER
-
DRIVE TEMPERATURE S\MTCH OR TEMPERATURE FUSE (OPEN GN RISE} © AC POWER <INPUT EXTERNAL EXT. o- - - - - _,, /\ SHUNT © SHUNT RESISTOR 220VAC NEON LAMP (OPTIONAL) FIGURE 6 DRIVE 1uF/600 VOLT GE P/N 40L6101 | TEMPERATURE SWITCH OR TEMPERATURE FUSE HO AC POWER i” (OPEN ON RISE} © INPUT Ceo SHUNT ° EXTERNAL Oo SHUNT RESISTOR 220VAC NEON LAMP (OPTIONAL)
FIGURE 7
17
Page 19
Automotion, Inc. LC4/5 User's Manual
The optional neon lamp is intended to show the user just how heavy a duty cycle is applied to the shunt resistor. It will blink every time the shunt resistor is toggled. If it blinks with a very short duty cycle under worst case decel conditions, the chances are that a higher ohmic resistor value could be used. If it DOES NOT blink at all an external shunt resistor may not be needed. If the user decides to use a temperature sensitive fuse or switch, it is very important that this device be located in close proximity to the shunt resistor. It is obvious that if the surface temperature of the shunt resistor becomes excessively hot the components listed on the previous page must respond effectively. Generally the temperature sensitive device should be mounted in contact with the surface of the shunt resistor or very close to it. Automotion favors the use of the installation shown in FIGURE 6 whenever possible. This is because it requires fewer components. If the installation in FIGURE 7 is used, the 1 µf capacitor should be located away from the path of heat if the shunt resistor should overheat. The capacitor shown in FIGURE 7 is made by General Electric under their part #40L6101. It may be possible to find an equivalent substitute. It is non-polarized and rated for 600 Volt DC service. If the installation shown in FIGURE 7 is used then this capacitor is required. Any installation without it is likely to render the temperature fuse or temperature switch as ineffective. Whichever method is chosen to locate the external shunt resistor, it should be wired to the Automotion drive using at least 16 AWG wire rated for 600 VAC service. We recommend that the wire have a Teflon jacket with a minimum 105° C temperature rating. Wiring guidelines are given in Section 8.1, "Shunt Requirement For Regenerative Braking". It is important that the wire to the shunt resistor be dressed using good installation practice to prevent any short circuits from happening. Short circuits will damage the Automotion drive.
18
The final method of installation should be tested to confirm that it functions correctly and safely. Also apply heat to the temperature sensing device chosen to confirm that it works consistently in your operating environment. Multiple tests are recommended. Any questions regarding the external shunt resistor should be directed to AUTOMOTION. These recommendations are intended to provide some help in your installation of an external shunt resistor. They are not a substitute for using good judgment and following recognized standards in your industry for making your installation safe and reliable under all possible conditions.
The bottom of this page is intentionally blank.
Page 20
Automotion, Inc. LC4/5 User's Manual
9.0
Input/Output Terminal Identification: Terminal Number
Function Description
9
1
COMMUTATION SIGNAL S1, INPUT PORT. Digital signal required from motor. A 10K ohm pull-up resistor is provided internally.
2
COMMUTATION SIGNAL S2, INPUT PORT. Digital signal required from motor. A 10K ohm pull-up resistor is provided internally.
3
COMMUTATION SIGNAL S3, INPUT PORT. Digital signal required from motor. A 10K ohm pull-up resistor is provided internally.
4
+12 VOLT DC REGULATEDOUTPUT PORT. 25 mA maximum load. This may be the power source for the commutation sensors in motor and some external logic.
5
LOGIC GROUND. All external logic should be referenced here. This port is isolated from chassis frame ground and from the AC power lines.
6
START/STOP CONTROL INPUT PORT. Approximately 4.7K ohm input Z. This port is TTL compatible. The maximum applied voltage here must not exceed +24 VDC. 0 volts stops the control. The default condition is STOP.
7
8
Terminal Number
FORWARD/REVERSE DIRECTION CONTROL, INPUT PORT. This port is TTL compatible. The maximum applied voltage here must not exceed +24 VDC. O volts enables ``forward'' motor rotation. Default condition is FORWARD. DYNAMIC BRAKE CONTROL, INPUT PORT. This port is TTL compatible. 0 volts turns off the brake. The default condition is brake ``OFF''.
19
Function Description
OPEN LOOP SPEED CONTROL INPUT PORT. Requires a 0 to +10 volt signal to set the open loop motor speed. +10 volts produces maximum motor RPM's and 100% PWM amplifier output. 0 volts produces zero motor speed and 0% PWM amplifier output. The input Z is approximately 22K ohm. The default condition is zero speed. (+/- volt input optional.)
10 DUAL SPEED SELECT CONTROL, INPUT PORT. A TTL compatible port for selecting one of two Closed Loop speed settings. This uses the internal single quadrant Closed Loop speed control. Both speed settings are controlled through built-in pots. The default condition selects Velocity Setpoint #1. 11 EXTERNAL CLOSED LOOP SPEED CONTROL, INPUT PORT. This port allows for an external signal source to control the internal single quadrant Closed Loop speed. The input Z is approximately 10K ohm. 12 EXTERNAL ENCODER/ EXTERNAL PWM INPUT PORT. This port is TTL compatible. The maximum applied voltage here must not exceed +24 VDC. See Sections 12, 13, and Appendix A & B for configuration details. 13 CURRENT SIGNAL OUTPUT PORT. (Optional). Approximately +.05 volts/Ampere. See Section 19.1 for details. 14 EXT. CURRENT LIMIT TRIP, INPUT PORT. Whenever a digital signal is applied here of +12 volts in amplitude, the LC4/5 stops sourcing current to the motor. Input Z is approximately 22K ohms. See Section 17.0 for details. 15 CHASSIS FRAME GROUND (i.e., heat sink)