Page 1 of Model LC4/5 "PLUS" User's Manual

Manual · AutoMotion

Model LC4/5 "PLUS" User's Manual

Manual40 pagesPDF 234 KB

User's manual for the Automotion LC4/5 "PLUS" brushless DC motor controls: specifications, wiring, setup and speed control modes.

What this file really is

The old site listed this file as a manual for the AutoMotion AT4CP10200. The file is named for the AutoMotion AT4CP10200, but the document is the user's manual for the Automotion LC4/5 "PLUS" brushless DC motor controls and does not mention the AT4CP10200.

Download the PDF234 KB

Filed with · 1 model

Also filed with these models on the old site

Summary

What is in it

Automotion's user's manual for the LC4/5 "PLUS" series of brushless DC motor controls (models LC4A to LC4D and LC5A to LC5C, packaged "P" or open frame). It gives safety precautions, specifications, a quick-start wiring procedure, power supply and motor requirements, terminal identification and mounting, then explains open loop, closed loop and external PWM speed control, reversing and 4 quadrant operation, dynamic braking, soft start, current limit setting and troubleshooting.

Its parts

  1. Safety Precautions
  2. Unpacking and Repacking
  3. LC4/5 Product Family Specifications
  4. Quick-Start Setup
  5. Last Minute Checklist
  6. Power Supply Requirements
  7. Motor Requirements
  8. External Shunt Resistor
  9. Input/ Output Terminal Identification
  10. Installation: Mechanical
  11. Running the Motor with the LC4/5: OPEN LOOP
  12. Running the Motor with the LC4/5: CLOSED LOOP
  13. External PWM Speed Control
  14. Reversing the Motor, 4 Quadrant Operation
  15. Dynamic Braking the Motor

From the manual

Key facts from this manual

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

This is the AutoMotion user's manual for the Model LC4/5 PLUS brushless DC motor control family: models LC4A to LC4D and LC5A to LC5C, packaged (P) or open frame. It does not name the AT4CP10200. It gives specifications, safety rules, quick-start wiring, the terminal list, mounting, running the motor and troubleshooting.

Read for this summary: pages 1 to 9, 20 to 22, 26 to 28 and 39 to 40 of 40.

What it is
LC4/5 PLUS brushless DC motor control; models LC4A, LC4B, LC4C, LC4D, LC5A, LC5B, LC5C, packaged (P) or open frame p. 1, 7
AC input
LC4: 95 to 132 VAC RMS; LC5: 190 to 245 VAC RMS; single phase, 50/60 Hz p. 5
Output to motor
LC4: nominally +160 volts chopped DC; LC5: nominally +320 volts, phase-to-phase p. 5
Drive type
2 quadrant, six step, 3 phase, full wave PWM output at about 18 KHz p. 5
Speed control
External 0 to +10 volt analog signal or external PWM; internal 2 quadrant closed loop; optional +/- 10 volt input card p. 6
Commutation
Three Hall or optical rotor sensors; 60 or 120 electrical degrees set by jumper group 2, normally shipped at 120 p. 6, 9
Motor requirements
Three phase WYE or DELTA brushless DC motor for 160 volts DC, at least 150 micro Henries and 0.5 msec time constant p. 6
Fuses
LITTELFUSE #314007 (LC4A), #314010 (LC4B, LC5A), #314015 (LC5B), #314020 (LC4C, LC5C), #314025 (LC4D) p. 7
Terminals
1 to 3 sensor inputs, 4 +12 V out, 5 logic ground, 6 start/stop, 7 forward/reverse, 8 brake, 9 speed input, 15 chassis ground, 16 and 17 AC in, 18 to 20 motor phases p. 20, 21, 22
Logic inputs
Terminals 1 to 14 isolated from AC power; TTL or toggle switches; maximum +24 volts DC p. 6
Temperature
Operating 0 to +50 degrees Celsius (shutdown at +50 on heat sink); storage -20 to +85; humidity 5 to 95% RH non-condensing p. 5
Packaged unit size
9.25 in high, 5.4 in wide, 8.5 in deep; 6.25 lb max (2.81 Kg) p. 6
Dynamic brake
Maximum 2% duty cycle; 10 watts continuous, 650 watts intermittent p. 6
Short circuit protection
Protected against momentary shorts to ground, to the AC rails or phase-to-phase; reset by the enable/disable line p. 6, 7

What this manual walks you through

  • Safety precautions before using the control p. 2, 3
  • Unpacking, inspecting and repacking the control p. 4
  • Quick-start wiring of motor phases, rotor sensors and AC power p. 7, 9
  • Setting the commutation phase jumper for 60 or 120 degrees p. 9
  • Last minute checklist before first power-up p. 9
  • Input and output terminal identification p. 20, 21
  • Mounting packaged and open frame units p. 21
  • Running the motor in open loop and closed loop speed control p. 22
  • Troubleshooting by symptom, including the Power/OT Fault and Current Limit LEDs p. 26, 28

Good to know

  • At least 12 minutes must pass after all external power is disconnected before the control may be handled. p. 21
  • The control runs only one brushless DC motor; motors must not be paralleled off one control. p. 3
  • The control shuts down when the heat sink reaches about 50 degrees Celsius; toggle Start/Stop to restart after it cools. p. 6
  • Limits apply to rapid direction changes above 1000 RPM. p. 22
  • Connectors P1 and P2 must not be removed while the motor runs, and P2 must not be plugged in when wired to live AC. p. 2

Questions this manual answers

What fuse does the AutoMotion LC4C take?

A LITTELFUSE #314020 or equivalent. p. 7

Why does the Power/OT Fault LED come on when the LC4/5 tries to run the motor?

The supply may be below 95 VAC (LC4) or 190 VAC (LC5), or the chassis may be near 50 degrees Celsius; either shuts it down. p. 28

What AC voltage do the LC4 and LC5 run on?

LC4: 95 to 132 VAC; LC5: 190 to 245 VAC, single phase, 50/60 Hz. p. 5

How do I restart the LC4/5 after a power interruption?

Toggle the Start/Stop input, terminal 6, from OFF to ON; the Power/OT Fault LED being lit at power-up is normal. p. 9

How do I set the LC4/5 for a 60 or 120 degree motor?

Place the jumper in jumper group 2 on the bottom of the unit; units normally ship set for 120 degrees. p. 9

The whole text · 4 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20
  3. Pages 21 to 3021-30
  4. Pages 31 to 4031-40

The file

Revision and size

RevisionDocument Revision 0, May 1, 1996, Document Control# A10505
PublisherAutomotion Incorporated
Pages40
PDF234 KB
TextText from the PDF itself; page 18 is a scan, read by OCR, which may hold reading errors.