Page 31
Automotion, Inc. LC4/5 User's Manual
Use of the optional current signal output feature.
FIGURE 9 Suggested method for current loop feedback.
30
Page 32
Automotion, Inc. LC4/5 User's Manual
20.0
Custom Features Section: If your unit included any non-standard, custom features; they would be listed here.
31
Page 33
Automotion, Inc. LC4/5 User's Manual
21.0
Warranty:
22.0
AUTOMOTION INCORPORATED hereinafter referred to as the ``Company,'' warrants its products for a period of 2 years from date of shipment to be free of defects caused by faulty material or inferior workmanship. The liability of the Company under this warranty extends to the replacement, repair, or issuance of credit, at the Company's option, for any of its products which are returned by the initial Purchaser during such period, provided: The Company is promptly notified in writing upon discovery of such defects by Purchaser. The defective product(s) is returned to the Company after the Company has issued a Return Authorization Number, with all return transportation charges prepaid by Purchaser. The Company's examination of such product(s) shall disclose to its satisfaction that such defects exist and have not been caused by improper installation, neglect, repair, alteration, misapplication, or accident caused by the Purchaser. Under no circumstances shall the Company be liable for collateral or consequential damages of any nature incurred through the use of our products.
32
Life Support Policy: AUTOMOTION'S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF AUTOMOTION INCORPORATED. As described herein: Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and whose failure to perform, when properly used in when properly used in accordance with instructions for use provided in the User's Manual and in the labeling, can be reasonable expected to result in a significant injury to the user. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
Page 34
Automotion, Inc. LC4/5 User's Manual
23.0
Appendices: Appendix A: Suggested method for external logic control interfacing.
NOTES:
Use of the PWM signal input for speed control is optional. If this input is to be used Terminal #9 should be connected to Terminal #4. See the manual for additional details. All logic input/output signals on the LC4/5 are electrically isolated from the motor drive output power.
33
Page 35
Automotion, Inc. LC4/5 User's Manual
Appendix B: Use of an external input signal with an external closed loop speed reference signal input.
NOTES:
The input impedance of Terminal #11 is 10K ohm. Therefore, both the low pass filter time constant required to smooth the incoming PWM signal and the peak signal required. A buffer amplifier between the RC filter and Terminal #11 may be needed. The signal source coming into Terminal #11 need not be just from a PWM generator. An analog source may be used directly. Check the Group 1 jumper setting if an external encoder signal is to be used. See Section 12.0 for details.
34
Page 36
Automotion, Inc. LC4/5 User's Manual
Appendix C: Motor Phase Commutation Sequence and Input/Output State Tables: The following tables may be used to understand how the feedback signals from the three rotor positional sensors are decoded and subsequently energize the output phases of the LC4/5 control. In each table a ``1'' designates a + or ``high'' logic signal level. Conversely, a ``0'' designates a ``low'' logic signal level. For correct signal transition recognition, all + or ``high'' logic signal levels must match, but not exceed, the amplitude of the voltage available on Terminal #4 of the LC4/5 control. AUTOMOTION recommends that the output voltage source available at Terminal #4 be used to power your external rotor positional sensors.
I/O State Table; 60 Electrical Degree Communication Signal Phase Shift:
S1
S2
Forward Motion Current Source -Current Sink S3 Output Enabled Output Enabled
0 1 1 1 0 0
0 0 1 1 1 0
0 0 0 1 1 1
Phase 2 Phase 2 Phase 1 Phase 1 Phase 3 Phase 3
Phase 1 Phase 3 Phase 3 Phase 2 Phase 2 Phase 1
Reverse +Current Source Output Enabled
Motion -Current Sink Output Enabled
Phase 1 Phase 3 Phase 3 Phase 2 Phase 2 Phase 1
Phase 2 Phase 2 Phase 1 Phase 1 Phase 3 Phase 3
I/O State Table; 120 Electrical Degree Communication Signal Phase Shift Mode:
S1
S2
Forward Motion Current Source -Current Sink S3 Output Enabled Output Enabled
0 1 1 1 0 0
0 0 0 1 1 1
1 1 0 0 0 1
Phase 2 Phase 2 Phase 1 Phase 1 Phase 3 Phase 3
Phase 1 Phase 3 Phase 3 Phase 2 Phase 2 Phase 1
Reverse +Current Source Output Enabled
Motion -Current Sink Output Enabled
Phase 1 Phase 3 Phase 3 Phase 2 Phase 2 Phase 1
Phase 2 Phase 2 Phase 1 Phase 1 Phase 3 Phase 3
Please Note: The Dynamic Brake input port, when enabled, will activate current sink outputs and disable all current source outputs. By applying a 0 to +10 volt DC analog signal to Terminal #9, the rate of braking may be throttled. See Section 15.0, ``Dynamic Braking the Motor,'' for additional details.
35
Page 37
Automotion, Inc. LC4/5 User's Manual
Appendix D: Basic wiring installation details of LC4/5 with optional DC bus input.
NOTES!
LOGIC GROUND and chassis ground are NOT common with each other and normally are kept separate from each other externally. Also, be aware of restrictions involving the use of the Forward/Reverse at high RPM's. SEE THE MANUAL FOR ADDITIONAL DETAILS!! Shown above is a simple open loop speed control installation.
36
Page 38
Automotion, Inc. LC4/5 User's Manual
24.0
Addendum:
37
Page 39
Automotion, Inc. LC4/5 User's Manual
TABLE OF CONTENTS Section#
Section Title
1.0
Safety Precautions
2.0
Unpacking and Repacking
3.0
LC4/5 Product Family Specifications
4.0
Quick-Start Setup
5.0
Last Minute Checklist
6.0
Power Supply Requirements
7.0
Motor Requirements
8.0
External Shunt Resistor
9.0
Input/ Output Terminal Identification
10.0
Installation: Mechanical
11.0
Running the Motor with the LC4/5: OPEN LOOP
12.0
Running the Motor with the LC4/5: CLOSED LOOP
13.0
External PWM Speed Control
14.0
Reversing the Motor, 4 Quadrant Operation
15.0
Dynamic Braking the Motor
16.0
Using Soft Start
17.0
Setting the Maximum Current Limited Output
18.0
In Case of Trouble
19.0
Optional Equipment
20.0
Custom Features Section
21.0
Warranty
22.0
Life Support Policy
23.0
Appendices/ Application Notes
24.0
Addendum
PLEASE NOTE! Read this manual entirely. Particularly "SAFETY PRECAUTIONS" BEFORE attempting to use the LC4/5 Brushless Motor Control.
Page 40
Automotion, Inc. LC4/5 User's Manual
List of Illustrations Figure 1
LC4/5 Basic Wiring Details
Figure 2
Typical Hall Sensor Interface
Figure 3
Options For Commutation Signal Phase Relationships
Figure 4
Packaged LC4/5
Figure 5
Open Frame LC4/5
Figure 6
External Shunt Hook-up 1
Figure 7
External Shunt Hook-up 2
Figure 8
LED Diagnostics Chart
Figure 9
Optional Current Signal Output Feature
PLEASE NOTE! Read this manual entirely. Particularly "SAFETY PRECAUTIONS" BEFORE attempting to use the LC4/5 Brushless Motor Control.