Page 120
SC22-3/-3E Safety Controller Instruction Manual
12 Glossary A Automatic Reset The safety input device control operation setting where the assigned safety output will automatically turn on when all of its associated input devices are in the Run state. C Complementary Contacts Two sets of contacts which are always in opposite states.
Change of State (COS) The change of an input signal when it switches from Run-to-Stop or Stop-to-Run state.
Concurrent (also Concurrency) The setting in which both channels must be off at the same time before turning back on. If this is not satisfied, the input will be in a fault condition.
Closed-Open Debounce Time Time to bridge a jittery input signal or bouncing of input contacts to prevent nuisance tripping of the Controller. Adjustable from 6 ms to 100 ms. The default value is 6 ms (50 ms for mute sensors). D Designated Person A person or persons identified and designated in writing, by the employer, as being appropriately trained and qualified to perform a specified checkout procedure.
Dual-Channel Having redundant signal lines for each safety input or safety output.
Diverse-Redundancy The practice of using components, circuitry or operation of different designs, architectures or functions to achieve redundancy and to reduce the possibility of common mode failures. M Machine Response Time The time between the activation of a machine stopping device and the instant when the dangerous parts of the machine reach a safe state by being brought to rest.
Manual reset The safety input device control operation setting where the assigned safety output will turn On only after a manual reset is performed and if the other associated input devices are in their Run state. O
Off Signal The safety output signal that results when at least one of its associated input device signals changes to the Stop state. In this manual, the safety output is said to be Off or in the Off state when the signal is 0 V dc nominally.
Open-Closed Debounce Time Time to bridge a jittery input signal or bouncing of input contacts to prevent unwanted start of the machine. Adjustable from 10 ms to 500 ms. The default value is 50 ms.
On Signal The safety output signal that results when all of its associated input device signals change to the Run state. In this manual, the safety output is said to be On or in the On state when the signal is 24 V dc nominally. P Pass-Through Hazard A pass-through hazard is associated with applications where personnel may pass through a safeguard (which issues a stop command to remove the hazard), and then continues into the guarded area, such as in perimeter guarding. Subsequently, their presence is no longer detected, and the related danger becomes the unexpected start or restart of the machine while personnel are within the guarded area.
PELV Protected extra-low voltage power supply, for circuits with earth ground. Per IEC 61140: "A PELV system is an electrical system in which the voltage cannot exceed ELV (25 V ac rms or 60 V ripple free dc) under normal conditions, and under single-fault conditions, except earth faults in other circuits."
Q Qualified Person A person who, by possession of a recognized degree or certificate of professional training, or who, by extensive knowledge, training and experience, has successfully demonstrated the ability to solve problems relating to the subject matter and work. R Run Signal The input signal monitored by the Controller that, when detected, causes one or more safety outputs to turn On if their other associated input signals are also in the Run state. In this manual, either the input device or the device signal is said to be in the Run state.
120 www.bannerengineering.com - Tel: 763.544.3164
Page 121
SC22-3/-3E Safety Controller Instruction Manual
S Safety-Rated Device A device that is designed to an applicable safety standard and when properly applied, reduces the level of risk. SELV Separated or safety extra-low voltage power supply, for circuits without earth ground. Per IEC 61140: "A SELV system is an electrical system in which the voltage cannot exceed ELV (25 V ac rms or 60 V ripple free dc) under normal conditions, and under single-fault conditions, including earth faults in other circuits." Simultaneous (also Simultaneity) The setting in which both channels must be off at the same time AND, when they turn back on, they must turn on within 3 seconds of each other. If both conditions are not satisfied, the input will be in a fault condition. Single-Channel Having only one signal line for a safety input or safety output.
Start Up Test For certain safety devices, like safety light screens or safety gates, it can be an advantage to test the device on power up at least one time for proper function. If ‘Start up Test’ has been selected for a safety light screen and the light screen is clear at power up, it would be necessary to cycle the light screen one time (from On to Off and back to On), even if the Controller has been configured for auto power up. Stop Signal The input signal monitored by the Controller that, when detected, causes one or more safety outputs to turn Off. In this manual, either the input device or device signal is said to be in the Stop state. System Reset The term used to describe a manual system reset operation required for one or more Safety Outputs to turn On after Controller power-up, when configured for manual power-up, and lockout (fault detection) situations.
www.bannerengineering.com - Tel: 763.544.3164
121
Page 122
Index C
String 118 System Checkout 72, 73 System Reset 70
Checkout 72, 73 Cleaning 79 Commissioning Checkout 72, 73
L
D
O
Daily Checkout 72 Dword 118
Octet 118
E
P
Ethernet 11
Periodic Checkout 72, 73
UDINT 118 UINT 118
F
R
W
Fault Diagnostics 79 Faults 79
Repairs 79
Warranty 79 Word 118
H
S
Hex 118
Semi-annual Checkout 72
Lockout 71, 83
T Troubleshooting 79
U