Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of SC22-3/-3E Safety Controller Instruction Manual

Manual · Banner

SC22-3/-3E Safety Controller Instruction Manual

Manual122 pagesPDF 6.1 MB

Instruction manual for the Banner SC22-3 and SC22-3E configurable 24V dc safety controllers, including the Ethernet model.

Download the PDF6.1 MB

Covers · 1 model

The models it covers

Summary

What is in it

The Banner instruction manual for the SC22-3 and Ethernet-compatible SC22-3E safety controllers, which monitor safety and non-safety input devices and control up to three independent machine primary control elements. It covers components and specifications, installation and input device wiring, safety and status outputs, configuration from a PC or the onboard LCD, operation, checkout procedures, troubleshooting with fault codes, a reference for input devices and safety categories, and the Ethernet reference.

Its parts

  1. About This Document
  2. Overview
  3. Components and Specifications
  4. System Installation
  5. PC Interface Configuration (PCI)
  6. Onboard Interface Configuration (OBI)
  7. Operating Instructions
  8. System Checkout
  9. Troubleshooting
  10. Input Device and Safety Category Reference
  11. Ethernet Reference

From the manual

Key facts from this manual

Each line names its page in the PDF.

Instruction manual for the Banner SC22-3 and SC22-3E Safety Controllers, configurable 24V dc controllers that monitor safety and non-safety input devices and switch up to three independent safety outputs. The SC22-3E adds an Ethernet port to the features of the SC22-3. It covers ordering parts, specifications, installation, setup from a PC or the onboard display, checkout and fault codes.

Read for this summary: pages 1, 9 to 11, 15 to 16, 21 to 24 and 79 to 82 of 122.

Device
Configurable 24V dc safety controller for safety and non-safety input devices, controlling up to three machine primary control elements p. 9
Supply voltage
24V dc, ± 20% p. 23
SC22-3E current
SC22-3E: 0.4 A controller only, 4.9 A with all outputs on at full rated load p. 23
Ethernet
SC22-3E: 10/100 Base-T/TX, RJ45; EtherNet/IP (with PCCC) and Modbus/TCP; 32 virtual status outputs, fault codes and fault log p. 23
Inputs
22 input terminals for safety or non-safety devices p. 15
Safety outputs
3 redundant solid-state safety outputs, SO1, SO2 and SO3 (6 terminals) p. 15, 23
SC22-3E output rating
SC22-3E: 0.5 A max. per safety output at 24V dc p. 23
Status outputs
10 configurable; 0.5A each, 1.0 A total, at 24V dc p. 16, 23
Response time
10 ms max. ON to OFF with standard 6 ms debounce; recovery 400 ms max. with manual reset p. 23
Operating temperature
0 °C to +55 °C (+32 °F to +131 °F) p. 23
PC software
PCI software on CD p/n 134534; Windows XP, 2000, Vista or 7; USB 1.1 or 2.0 type A port p. 10, 11
Spare parts
SC-XM1 memory card (SC-XM1-5 pack of 5), SC-XMP card programming tool, SC-TS1 screw and SC-TC1 clamp terminal sets, SC-USB1 1.8 m USB A/B cable p. 21
Ethernet cordsets
Cat5e shielded STP07, STP25, STP50, STP75; crossover STPX07, STPX25, STPX50, STPX75; 2.1 m to 22.9 m p. 21, 22
Interface modules
SC-IM9A, SC-IM9B, SC-IM9C (10A; for 1, 2 or 3 safety outputs); IM-T-9 series such as IM-T-9A (6A) p. 22

What this manual walks you through

  • Choosing a starter kit, replacement parts and accessories p. 21, 22
  • Connecting the controller to a PC by USB and to a network by Ethernet p. 11
  • Setting ON-delays and OFF-delays on the safety outputs p. 16
  • Choosing what the status outputs report p. 16
  • Cleaning the controller p. 79
  • Tracking down random trips and lockouts p. 79
  • Looking up fault codes and the checks for each p. 79, 80, 81, 82

Good to know

  • Connect the controller only to a SELV or PELV power supply. p. 23
  • Rated NEMA 1 (IEC IP20); mount it inside a NEMA 3 (IEC IP54) or better enclosure. p. 23
  • Clamp terminals take one wire only; a second wire can loosen and cause a short. p. 23
  • External device monitoring must be wired separately to the N.C. contacts of interface modules. p. 22
  • The controller has no field-replaceable parts and should not be repaired in the field. p. 79

Questions this manual answers

What power supply does the SC22-3E need?

24V dc ± 20% from a SELV or PELV supply. The SC22-3E draws 0.4 A alone and 4.9 A with all outputs on at full rated load. p. 23

Which Ethernet protocols does the SC22-3E support?

EtherNet/IP (with PCCC) and Modbus/TCP over 10/100 Ethernet. The manual lists ControlLogix, SLC and PLC5 PLCs and Modbus/TCP devices. p. 9, 23

What does fault code 4.1 Supply Voltage Low mean?

The supply voltage fell below the rated voltage for more than 6 ms. Check the power supply voltage and current rating and look for overloaded outputs. p. 82

What is the part number of the SC22 memory card?

The external memory (XM) card is SC-XM1, sold as a pack of 5 as SC-XM1-5; the SC-XMP tool programs it from a PC. p. 21

Why does the SC22 safety controller trip or lock out at random?

Intense electrical noise can cause it. Check that the supply is within 24 V dc ± 20%, terminal blocks are fully inserted, wires are secure and no noise sources run nearby. p. 79

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. 1 About This Document5
    1. 1.1 Important . . . Read This Before Proceeding!5
    2. 1.2 EC Declaration of Conformity (DoC)5
    3. 1.3 Standards and Regulations5
    4. 1.4 Contact Us7
    5. 1.5 Banner Engineering Corp Limited Warranty7
  2. 2 Overview9
    1. 2.1 Ethernet-Compatible Model9
    2. 2.2 Applications10
    3. 2.3 Design and Testing10
    4. 2.4 Components10
    5. 2.5 Configuring the Safety Controller12
    6. 2.6 Input and Output Connections15
    7. 2.7 System Settings18
    8. 2.8 Internal Logic19
    9. 2.9 Password Overview19
    10. 2.10 Confirming a Configuration20
  3. 3 Components and Specifications21
    1. 3.1 SC22-3 Safety Controller Starter Kit Models21
    2. 3.2 Replacement Parts/Accessories21
    3. 3.3 Ethernet Cordsets21
    4. 3.4 Interface Modules22
    5. 3.5 Specifications23
  4. 4 System Installation25
    1. 4.1 Appropriate Application25
    2. 4.2 Installing the Safety Controller25
    3. 4.3 Safety Input Devices26
    4. 4.4 Non-Safety Input Devices30
    5. 4.5 Input Device Resets31
    6. 4.6 Safety Input Function33
    7. 4.7 EDM, OSSD (Safety Output), and FSD Hookup37
    8. 4.8 Status Outputs46
    9. 4.9 Virtual Status Outputs49
    10. 4.10 Commissioning Checkout49
  5. 5 PC Interface Configuration (PCI)50
    1. 5.1 PC Interface (PCI) Overview50
  6. 6 Onboard Interface Configuration (OBI)59
    1. 6.1 Onboard Interface (OBI) Overview59
    2. 6.2 Run Mode61
40 more lines, from page 61 on
  1. 6.3 Configuration Mode61
    1. 6.4 Edit Configuration63
    2. 6.5 Add an Input65
  2. 7 Operating Instructions68
    1. 7.1 Monitoring Controller Operation68
    2. 7.2 Display Controller Information, PC Interface (PCI)68
    3. 7.3 Display Controller Information, Onboard Interface (OBI)68
    4. 7.4 Manual Reset70
    5. 7.5 System Resets and Lockout Conditions70
    6. 7.6 Reset Signal Requirements71
  3. 8 System Checkout72
    1. 8.1 Schedule of Required Checkouts72
    2. 8.2 Commissioning Checkout Procedure72
    3. 8.3 Initial Setup, Commissioning and Periodic Checkout Procedures73
  4. 9 Troubleshooting79
    1. 9.1 Cleaning79
    2. 9.2 Repairs and Warranty Service79
    3. 9.3 Finding and Fixing Faults79
    4. 9.4 Recovering from a Lockout83
    5. 9.5 Fault Diagnostics83
    6. 9.6 Fault Diagnostics - OBI84
  5. 10 Input Device and Safety Category Reference86
    1. 10.1 Safety Circuit Integrity and ISO 13849-1 Safety Circuit Principles86
    2. 10.2 Protective (Safety) Stop88
    3. 10.3 Interlocked Guard or Gate89
    4. 10.4 Optical Sensor94
    5. 10.5 Two-Hand Control96
    6. 10.6 Safety Mat99
    7. 10.7 Emergency Stop Push Buttons102
    8. 10.8 Rope (Cable) Pull105
    9. 10.9 Enabling Device106
    10. 10.10 Bypass Switches (Bypassing Safeguards)108
    11. 10.11 Mute Sensor Pair110
  6. 11 Ethernet Reference116
    1. 11.1 Ethernet Setting Access116
    2. 11.2 EtherNet/IP Assembly Objects116
    3. 11.3 Support Files117
    4. 11.4 Table Row and Column Descriptions118
  7. 12 Glossary120
  8. Index122

From the PDF’s own bookmarks.

The whole text · 18 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Contents1-4
  2. 1 About This Document5-8
  3. 2 Overview9-20
  4. 3 Components and Specifications21-24
  5. 4 System Installation, pages 25 to 3325-33
  6. 4 System Installation, pages 34 to 4234-42
  7. 4 System Installation, pages 43 to 4943-49
  8. 5 PC Interface Configuration (PCI)50-58
  9. 6 Onboard Interface Configuration (OBI)59-67
  10. 7 Operating Instructions68-71
  11. 8 System Checkout72-78
  12. 9 Troubleshooting79-85
  13. 10 Input Device and Safety Category Reference, pages 86 to 9586-95
  14. 10 Input Device and Safety Category Reference, pages 96 to 10496-104
  15. 10 Input Device and Safety Category Reference, pages 105 to 114105-114
  16. 10 Input Device and Safety Category Reference, page 115115
  17. 11 Ethernet Reference116-119
  18. Pages 120 to 122120-122

The file

Revision and size

Revision133487 Rev. D, 28 October 2015
PublisherBanner Engineering Corp.
Pages122
PDF6.1 MB
TextText from the PDF itself.

The first pages · 3 of 122

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 122
Page 2
Page 2of 122
Page 3
Page 3of 122