Page 59

SC22-3/-3E Safety Controller Instruction Manual

6 Onboard Interface Configuration (OBI) 6.1 Onboard Interface (OBI) Overview The Safety Controller’s onboard interface (OBI) consists of a display and six push buttons that are used to: • • • • • •

Select a language Create, confirm, edit, erase, send, and receive a configuration Display real-time Run mode information Display current fault data, fault log data, and to clear the fault log Display the model number of the Safety Controller Set a password

The configuration is used to define the input devices that will be connected to the Safety Controller and to establish relationships between input devices, and between the input devices and the outputs. This section provides a “map” and description of Run mode and Configuration mode options, using the OBI. See the following figure for an overview of all the Run mode and Configuration mode options available. For an example of a beginning-to-end configuration process using the OBI, refer to the OBI tutorial in the SC22 Configuration Tutorial, found at www.bannerengineering.com. Press the OK button to make a selection or move further into the menu tree; press the ESC button to move up a step. When a vertical list of options appears on the screen, use the Up/Down arrow buttons to highlight an option to select. Press OK to select the highlighted option. When a single option appears on the screen (for example, an input device) with an arrow running across the top of the screen, use the Left/Right arrow push buttons to step through the selections; press OK to select the option showing on the screen.

www.bannerengineering.com - Tel: 763.544.3164

59

Page 60

SC22-3/-3E Safety Controller Instruction Manual

Run Mode

ESC →

Configuration Mode

View Fault Log

← OK

ESC →

← OK

Clear Fault Log

Terminal Assignments

Confirm Configuration

ESC →

Receive File from XM

Confirm Safety Confirm Outputs System Settings

Edit Password

Set Language

Edit Input

Status Outputs

Safety Outputs

System Settings

Terminal Assignments

(Section 5.4.5)

ESC →

(Section 5.4.4)

← OK

← OK

ESC →

← OK

(Section 5.4.3)

Save Configuration

Input/Output Mapping

Status Output Settings

ESC →

Delete Input

Configuration Summary

Outputs/System Settings

Non-Safety Input

Safety Input

Cancel OFF Delay

Mute Enable

ON/OFF

← OK www.bannerengineering.com - Tel: 763.544.3164

Reset

AVM

Bypass Switch

Mute Sensor

Enabling Device

Rope Pull

EDM

Protective Stop

Safety Mat

Figure 46. OBI Configuration Mode Map

ESC →

(Section 5.5.2)

ESC →

Two-Hand Control

Optical Sensor

Gate Switch

E-Stop

← OK

(Section 5.5.1)

60

(Section 5.3.4)

Name Configuratio n (Section 5.4.1)

Inputs

← OK

Confirm Inputs

← OK

← OK

Send File to XM

Exit Configuration

(Section 5.3.4)

ESC →

← OK

Erase Configuration

(Section 5.4.2)

(Section 5.5)

Configuration Checksum

View Network Settings

System Options

(Section 5.3.3)

ESC →

← OK

(Section 5.3.2)

Add Input

View Response Times

ESC →

Configuration File

(Section 5.4)

Status Output Settings

Enter Password (Section 5.3.1)

Configuration Mode

Edit Configuration

Input/Outpu t Mapping

Set Display Contrast software and hardware versions

ESC →

View Current Faults

Model Number

Configuration Summary

(Section 5.3)

ESC →

← OK

Fault Diagnostics

ESC →

← OK

System Menu

View Response Times

Page 61

SC22-3/-3E Safety Controller Instruction Manual

6.2 Run Mode From Run mode, press OK to view the System menu. This menu provides the ability to read fault diagnostic information, enter the Configuration mode to create or edit a configuration, read the configuration summary, view the Safety Controller's model number, and adjust the contrast of the display. Use the Up/Down arrows to highlight your selection, then press OK to select. Fault Diagnostics - Use this screen to view current faults and the fault log, or clear the fault log. Refer to section Finding and Fixing Faults on page 79 for more information. Configuration Mode - Use this selection to enter the Configuration mode and to create or edit a configuration; refer to section Configuration Mode on page 61 for more information. Configuration Summary - This selection provides read-only screens to review: • • • • • •

Input device terminal assignments for each device in the current configuration The mapping relationships between input devices, and between input devices and safety outputs The current settings of the status outputs (to change the settings, see section Configuration File on page 61) Safety output response times (used to calculate safety distance) for each input mapped to the output The current network settings configured for network communication The configuration checksum: a unique identifier for any configuration that is programmed into a Safety Controller. It becomes available after a configuration is confirmed and is provided for the user to track configuration revisions

Use the Up/Down arrows to highlight your selection, then press OK to select it. Model Number - Select this screen to see the Controllers' model number, and software and hardware versions. This can be useful when an applications help call is needed. Set Display Contrast - Select this screen to adjust the brightness of the Controller display screen background and images for ambient conditions. Use the Left/Right arrows to adjust contrast level (left for lighter, right for more saturated); when contrast is correct, press OK.

6.3 Configuration Mode The first step in creating a configuration using the OBI is entering the Configuration mode. To enter the Configuration mode from the main Run mode screen, press OK to display the System menu. At the System menu, press the Down arrow until Configuration Mode is highlighted and press OK.

6.3.1 Enter Controller Password Before any configuration can take place, the password must be entered. The default password is 0000. For instructions on changing the password, refer to section System Options on page 63. • • • •

Use the Left/Right arrows to select the password digit position. Use the Up/Down arrows to select the value for each position (choices 0-9). When the password is entered, press OK to enter the Configuration mode. Read the caution that the safety outputs will turn OFF when Configuration mode is entered and press OK.

6.3.2 Configuration File Edit Configuration - To edit the configuration from the Configuration Mode menu, select Configuration File and press OK. See section Name Configuration on page 63 for more instructions. To begin editing the configuration, select Edit Configuration from the Configuration File menu and press OK. Erase Configuration - This selection is used to remove the current configuration from the Controller, so a new configuration can be created (the Controller can hold only one configuration at a time). To keep the current file, send it to the XM card before erasing it from the Controller. To perform an Erase, use the up/down arrows to select the option from the menu and press OK. When prompted whether you want to do this, highlight Yes and press OK. Send File to XM - This selection is used to send a configuration file to the XM card plugged into the Controller’s XM port. The file can then be stored and/or transported to another Controller. Insert the XM card into the Controller’s XM port, highlight the selection and press OK. www.bannerengineering.com - Tel: 763.544.3164

61

Page 62

SC22-3/-3E Safety Controller Instruction Manual Receive File from XM - This selection is used to receive a configuration from the XM card. Highlight the selection and press OK. The Controller will ask if you want to overwrite the current configuration (if not, send the existing configuration to an empty XM card first). Answer Yes, then if one is not already in the port, insert an XM card and press OK. If the new configuration is unconfirmed, the Controller provides the option to confirm it at this time.

6.3.3 Confirm Configuration Any changes are made to a configuration must be confirmed again before it can be used in a safeguarding application. Select Confirm Configuration and press OK. The Confirm Configuration menu will appear. Safety-critical configurations for the inputs, safety outputs, and the system settings are available for the review. An unchecked box in the Confirm Configuration menu indicates the safety-critical settings have not yet been confirmed.

Confirm Configurations of Inputs - Select Confirm Inputs and press OK. The next menu lists all of the safety inputs in the configuration. Use the Up/Down arrows to select an input and press OK. The next series of menus lists the safety-critical configurations for this input, including some or all of the following (depending on the device): • • • • • • • • • • • •

Circuit type Safety Output mapping or input mapping Reset logic (manual or automatic) Simultaneity (simultaneous or concurrent) Startup test Mute time limit Enabling device time limit Bypass time limit Debounce times (if not equal to default) Directional muting (enabled or disabled) Mute-dependent override (enabled or disabled) AVM monitoring time limit

Press OK after reviewing each setting. Repeat the confirmation process for each input. When all inputs have been confirmed, each input in the display will have a check mark. To continue confirming the configuration, select <Done> and press OK.

Confirm Configuration of Safety Outputs - Select Safety Outputs and press OK. Use the Up/Down arrows to select a safety output and press OK. The next series of menus displays the safety-critical configurations for the selected safety output. Review each setting and press OK. When a safety output has been confirmed, a checked box appears in front of it on the Confirm Outputs screen. Repeat the confirmation process for each safety output. When all safety outputs have been confirmed, each output in the display has a check mark.

After each output is confirmed, select <Done> and press OK. The Confirm Configuration menu reappears, indicating whether the inputs and safety outputs are confirmed. If any boxes do not have a check mark, repeat the confirmation of those components. Confirm System Settings - The last step is to confirm the system settings. Select System Settings and press OK. The next series of menus lists the safety-critical system settings. Review each setting and press OK to confirm.

62 www.bannerengineering.com - Tel: 763.544.3164

Page 63

SC22-3/-3E Safety Controller Instruction Manual

Final Confirmation Step - After all of the safety-critical configuration settings are confirmed, the configuration can be used in a safeguarding application. If any changes are made to the configuration, the confirmation process must be repeated. Select <Done> and press OK to exit the Confirm Configuration menu. Press ESC or go to Exit Configuration to return to Run mode.

6.3.4 System Options Edit Password - Allows to change the password to something other than the default. The password may be unique to each Controller. The procedure is similar to that used to enter the default password initially: 1. Use the Left/Right arrows to select the password digit position. 2. Use the Up/Down arrows to select the value for each position (0-9). 3. When the password is entered, press OK. Set Language - This screen is used to determine what language will appear on the display. The options are English, German, Spanish, French, Italian, Portuguese, and Japanese. Highlight the desired language then press OK. NOTE: Language can also be changed immediately following power-up. The screen appears automatically, and the language selection can be changed at that time. If nothing is changed, the screen times out after 5 seconds and continues to Run mode in the language that was selected before the Controller was last powered down.

6.3.5 Exit Configuration Use this screen to return to Run mode. Select Exit Configuration Mode and press OK to exit and return to the System Menu.

6.4 Edit Configuration 6.4.1 Name Configuration Follow these steps to give the configuration a custom name: 1. Use the Left/Right arrows to select the character position. Up to 16 characters are possible. 2. Use the Up/Down arrows to select the character for each position (choices A-Z, 0-9, -, +, or space). 3. When the configuration name is entered, press OK.

6.4.2 Inputs Add Input - Select this option to add either a safety or non-safety input device (see section Add an Input on page 65). Delete Input - This option is used to remove a previously added input device from the configuration. A screen will appear with all of the previously configured inputs; use the Left/Right arrows to select a device and press OK. Select Yes to confirm the deletion and press OK. If No is selected, the screen will return to choose a different input to delete. To return to the Inputs menu, press ESC. Edit Input - This option is used to edit a previously configured input device in the configuration. A screen will appear with all of the previously configured inputs; use the Left/Right arrows to select a device and press OK. A series of screens will appear, with the device’s properties; select each property (in the same way used to define the input initially; see section Add an Input on page 65), and press OK. The Inputs menu also displays when ESC is pressed after all of the required inputs have been added. Press ESC when the Inputs menu displays to return to the Edit Configuration menu.

6.4.3 Outputs/System Settings www.bannerengineering.com - Tel: 763.544.3164

63

Page 64

SC22-3/-3E Safety Controller Instruction Manual

Safety Outputs This option is used to configure the safety outputs. Use the Up/Down arrows to select Safety Outputs and press OK. Select the output to configure and press OK. You will be given the opportunity to change the output’s name, and give it an ON- or OFF-delay.

Status Outputs This option is used to configure the status outputs. Status outputs are configured individually. Use the Up/Down arrows to select Status Outputs and press OK. Use the Left/Right arrows to select the status output to configure (O1 to O10), and press OK to view the Status Output Properties menu. The status outputs can be configured to indicate: • The status of an input device • The status of a safety output • A system lockout • An I/O fault • The need to perform a system reset • The need to perform a reset operation on a safety output • When an input is being muted • The logical status (ON or ON-delay) of a safety output Name the Status Output - Use the Up/Down arrows to select Change Name and press OK. 1. Use the Left/Right arrows to select the character to be changed (up to 10 characters) 2. Use the Up/Down arrows to change the character (A-Z, 0-9, -, +, and space) 3. Press OK when done 4. When the display returns to the Status Output Properties menu, the top line of the display will reflect the new name

Select the function of the Status Output - Use the Up/Down arrows to select Select Function and press OK. 1. Use the Left/Right arrows to select a function, then press OK 2. The display returns to the Status Output Properties menu

Select the source for the Status Output function - Select Select Source and press OK. 1. Use the Left/Right arrows to select a device and press OK 2. The display returns to the Status Output Properties menu

Select the signal convention - The options are: • 24V = Input Active and • 24V = Input Inactive (for example, if tracking an input; see section External Device Monitoring (EDM) on page 37 for more information). 1. Use the Left/Right arrows to toggle between the selections and press OK. 2. To save the settings for this output, select <Done> and press OK. The display returns to the Outputs/System Settings menu. To configure additional status outputs, select Status Outputs, select another status output and repeat the steps above. When the last status output is configured, press ESC to return to the Edit Configuration menu.

System Settings Select the output’s reset mode, power up mode, and whether mute will be active on power-up. System Reset - Use the Left/Right arrows to toggle between Monitored or Non-Monitored, and press OK. Power Up Option - Use the Left/Right arrows to select among Normal, Auto, or Manual, and press OK. 64 www.bannerengineering.com - Tel: 763.544.3164

Page 65

SC22-3/-3E Safety Controller Instruction Manual Mute on Power-Up - Use the Left/Right arrows to toggle between Off or On, and press OK.

6.4.4 Configuration Summary The Configuration Summary menu provides read-only screens to review: • • • •

Input device Terminal Assignments for each device in the current configuration The mapping relationships between input devices, and between input devices and safety outputs The current settings of the status outputs (to change the settings, see section Outputs/System Settings on page 63) Safety output response times for each input mapped to the output. Response times can be used to calculate the minimum safety distance (separation distance)

Use the Up/Down arrows to navigate between options, then press OK to select.

6.5 Add an Input Input devices are categorized as either safety inputs or non-safety inputs. While the devices differ, the process for adding either is virtually identical. Use the up/down arrow buttons to select Safety or Non-Safety and press OK.

6.5.1 Add a Safety Input Safety input device options include: • E-stop buttons • Gate (interlock) switches • Optical sensors (including safety light curtains, single-/multiple-beam sensors, and area scanners) • Two-hand control devices • Safety mats • Protective stop devices • External device monitoring (EDM and AVM) contacts • Rope pulls • Enabling devices • Mute sensors • Bypass switches See section Input Device and Safety Category Reference on page 86 for more information about each of the input device types.

6.5.2 Add a Non-Safety Input Non-safety input device options include: • • • •

Manual reset switches ON/OFF switches Mute Enable switches Cancel OFF-delay switch

Select an Input Device (Either Safety or Non-Safety) - Use the left/right arrows to select the proper device, then press OK. The arrows at the top of the screen indicate whether more options are available to the left or to the right. After the device is selected, a new screen appears with the appropriate properties to select for that device.

6.5.3 Configure Input Device Properties For each input device, the following parameters must be configured: • Name (or use the auto-generated default name) • Circuit type • Terminal assignments (or use the auto-generated terminal assignments) • Reset logic (for some devices) • Output mapping or input mapping (depending on device) Enter Input Device Name - The Enter Name menu is displayed. A default name automatically appears, but the device may be renamed (up to 10 characters). www.bannerengineering.com - Tel: 763.544.3164

65

Page 66

SC22-3/-3E Safety Controller Instruction Manual

1. Use the left/right arrows to select the character position. 2. Use the up/down arrows to select the character for each position (choices A-Z, 0-9, -, +, or space). 3. When the screen (as shown below) shows the correct device name, press OK.

Input Properties Menu - The Input Properties menu is used to: • Select the input device’s circuit type • Edit the terminal assignments, if needed • Select the output(s) (or input), the input will control • Select between automatic and manual reset logic (depending on device) Select the Circuit Type of the Input - Use the up/down arrows to select Select Circuit Type, and press OK. See section Input Device and Safety Category Reference on page 86 for more information about safety circuit integrity levels and the capabilities of each circuit type. 1. The Select Circuit Type menu appears. 2. Use the left/right arrows to select the desired circuit type (a dual-channel, 4terminal circuit type is shown below) for the input device and press OK. 3. After the circuit type is selected, the display returns to the Input Properties menu.

Edit the Terminal Assignments - When the input circuit type is selected, the Safety Controller automatically assigns the next available terminals for the input device. Only unassigned terminals can be assigned. (Exception: Terminals used for a specific input device can be assigned twice during the edit process, if the same terminals will be used, in a different order, for this specific device.) To view and change these terminal assignments, select Edit Terminals, and press OK. 1. Use the left/right arrow buttons to select the terminal assignment to be changed. 2. Use the up/down arrows to change the terminal assignment. 3. When the terminal assignments are as desired, press OK. 4. After the terminal assignments are approved, the display returns to the Input Properties menu.

Map Outputs - This option is used to select which of the Safety Output(s) the input controls. Any combination of 1, 2, or all 3 outputs may be selected, but at least one must be selected. All safety devices, plus reset and ON/OFF non-safety devices must be mapped to one or more Safety Outputs. Map mute enable devices, mute sensors, and bypass sensors to a safety input device. 1. Select Map Outputs in the Input Properties menu, and press OK. 2. To map the input to an output, use the up/down arrows to select the output, then press OK. 3. A filled-in circle on the display indicates the input is mapped to the corresponding output; an empty circle indicates the input is not mapped to that output. 4. To add or remove the input mapping, select the output and press OK. When the input is mapped to the Safety Outputs as desired, select Save and press OK. 5. After the input is mapped to the Safety Outputs, the display returns to the Input Properties menu. The screen shows device ES01 mapped to all three Safety Outputs.

Select Reset Logic - To select automatic or manual reset logic, select Reset Logic and press OK. 1. Use the left/right arrows to select the desired reset logic parameter and press OK. 2. The display returns to the Input Properties menu.

66 www.bannerengineering.com - Tel: 763.544.3164

Page 67

SC22-3/-3E Safety Controller Instruction Manual

Save the Input Device Parameters - When all of the device’s parameters have been set as desired, select < Done > and press OK to save the parameters. 1. The display indicates the input parameters were saved. Press OK to continue. 2. The display returns to the Edit Inputs menu.

www.bannerengineering.com - Tel: 763.544.3164

67