Page 51
CANopen, DeviceNet BX5xxx, BC5250
DeviceNet, Modbus, RS485/RS232 | Bus Terminal Controller
CANopen Bus Terminal Controller
DeviceNet “Compact” Bus Terminal
DeviceNet Bus Terminal Controller for up to 64 Bus Terminals
Controller for up to 64 Bus Terminals for up to 64 Bus Terminals
(255 with K-bus extension)
(255 with K-bus extension)
(255 with K-bus extension)
Technical data
BX5100
BC5250
BX5200
Number of Bus Terminals
64 (255 with K-bus extension)
64 (255 with K-bus extension)
Max. number of bytes
32 Tx/Rx PDOs
512 byte input and 512 byte output
1,450 mA
1,000 mA
1,450 mA
The BX5100 Bus Terminal Controller has a CANopen slave interface. It has automatic baud rate detection up to 1 Mbaud and an address selection switch for address assignment.
The “Compact” BC5250 Bus Terminal Controller with DeviceNet interface extends the Beckhoff small controller series by a cost-optimised version in a compact housing. The DeviceNet Controller offers automatic baud rate detection up to 500 kbaud and two address selection switches for address assignment.
The BX5200 Bus Terminal Controller has a DeviceNet slave interface. It has automatic baud rate detection up to 500 kbaud and an address selection switch for address assignment. Up to 512 byte of input and 512 byte of output can be exchanged with the controller.
Bus interface open style connector, 5-pin open style connector, 5-pin open style connector, 5-pin
Data transfer rates automatic detection up to 1 Mbaud automatic detection up to 500 kbaud automatic detection up to 500 kbaud
Program memory
256 kbytes
48 kbytes
256 kbytes
Data memory
256 kbytes
32 kbytes
256 kbytes
Remanent data
2 kbytes
2 kbytes
2 kbytes
Online change yes yes yes
Weight approx. 250 g approx. 100 g approx. 250 g
Operating temperature
0…+55 °C
0…+55 °C
0…+55 °C
Approvals
CE, UL
CE, UL, Ex
CE, UL
Further information www.beckhoff.com/BX5100 www.beckhoff.com/BC5250 www.beckhoff.com/BX5200 fieldbus
Bus Terminal
Current supply K-bus
510
Accessories Cordsets and connectors see page
608 see page
608 see page
608
PC Fieldbus Cards
FC510x
703
FC520x
704
FC520x
704
TwinCAT PLC see page
794 see page
794 see page
794
BECKHOFF New Automation Technology
We reserve the right to make technical changes.
Page 52
BC7300, BC80xx
Modbus, RS485
Modbus RS485 Bus Terminal Controller
RS485 Bus Terminal Controller
RS485 “Compact“ Bus Terminal for up to 64 Bus Terminals for up to 64 Bus Terminals
Controller for up to 64 Bus Terminals (255 with K-bus extension)
BC7300
BC8000
BC8050
64
64
64 (255 with K-bus extension)
512 byte input and 512 byte output
512 byte input and 512 byte output
1,750 mA
1,750 mA
Bus Terminal
1,000 mA
511
The Bus Terminal Controller BC7300 is a Bus Coupler with integrated PLC functionality and has a fieldbus interface for Modbus. The BC7300 is an intelligent slave and can be used as a non-central intelligence in the Modbus system.
The Bus Terminal Controller BC8000 is a Bus Coupler with integrated PLC functionality and has an RS485 interface. The programmable interface is suitable for the connection of serial devices. The protocol can be freely programmed. The serial interface then functions as a master.
The “Compact” Bus Terminal Controller BC8050 with serial RS485 interface extends the Beckhoff small controller series by a cost-optimised version in a compact housing. An open serial protocol – like in the BK8x00 Bus Couplers – and the Modbus RTU/ASCII protocol are implemented. The address and the protocol are selected via the two rotary selection switches.
D-sub 9-pin, RS485
RS485 D-sub
RS485 D-sub
150, 300, 600, 1,200, 2,400, 4,800, 9,600, 19,200,
1.2 kbaud…57.6 kbaud
1.2 kbaud…38.4 kbaud
32/96 kbytes
32/96 kbytes
48 kbytes
32/64 kbytes
32/64 kbytes
32 kbytes
512 bytes
512 bytes
2 kbytes
–
– yes approx. 170 g approx. 170 g approx. 100 g
0…+55 °C
0…+55 °C
0…+55 °C
CE, UL, Ex, GL
CE, UL, Ex, GL
CE www.beckhoff.com/BC7300 www.beckhoff.com/BC8000 www.beckhoff.com/BC8050
38,400 baud (default: 9,600 baud)
see page
608
– see page
We reserve the right to make technical changes.
see page
608
– 794 see page see page
608
– 794 see page
794
BECKHOFF New Automation Technology
Page 53
RS232/RS485
BC81xx, BX8000
RS232/RS485, Ethernet | Bus Terminal Controller
RS232 Bus Terminal Controller
RS232 “Compact“ Bus Terminal
RS232/RS485 Bus Terminal for up to 64 Bus Terminals
Controller for up to 64 Bus Terminals
Controller for up to 64 Bus Terminals
(255 with K-bus extension)
(255 with K-bus extension)
BX8000
Technical data
BC8100
BC8150
Number of Bus Terminals
64
64 (255 with K-bus extension)
Max. number of bytes
512 byte input and 512 byte output fieldbus 1,750 mA
1,000 mA
1,450 mA
The BC8100 Bus Terminal Controller is a Bus Coupler with integrated PLC functionality and has a RS232 interface, with which peer-to-peer connection is possible. The programmable interface is suitable for the connection of serial devices. The protocol can be freely programmed.
The “Compact” Bus Terminal Controller BC8150 with serial RS232 interface extends the Beckhoff small controller series by a cost-optimised version in a compact housing. An open serial protocol – like in the BK8x00 Bus Couplers – and the Modbus RTU/ASCII protocol are implemented.
The BX8000 Bus Terminal Controller is a stand-alone PLC. One unit consists of the BX8000 Bus Terminal Controller with up to 64 Bus Terminals and a bus end terminal. With the terminal bus extension system, the connection of up to 255 Bus Terminals is possible. The controller is programmed via the COM1 interface.
Bus interface
RS232 D-sub
RS232 D-sub open style connector, 5-pin
Data transfer rates
1.2 kbaud…57.6 kbaud
1.2 kbaud…38.4 kbaud
300 baud…115 kbaud
Program memory
32/96 kbytes
48 kbytes
256 kbytes
Data memory
32/64 kbytes
32 kbytes
256 kbytes
Remanent data
512 bytes
2 kbytes
2 kbytes
Online change
– yes yes
Weight approx. 170 g approx. 100 g approx. 250 g
Operating temperature
0…+55 °C
0…+55 °C
0…+55 °C
Approvals
CE, UL, Ex
CE, UL, Ex
CE, UL
Further information www.beckhoff.com/BC8100 www.beckhoff.com/BC8150 www.beckhoff.com/BX8000
Bus Terminal
Current supply K-bus
512
Accessories Cordsets and connectors see page
PC Fieldbus Cards
–
TwinCAT PLC see page
BECKHOFF New Automation Technology
608 see page
608
– 794 see page see page
608
– 794 see page
794
We reserve the right to make technical changes.
Page 54
BC90xx
Ethernet
Ethernet Bus Terminal Controller
Ethernet “Compact“ Bus Terminal
Ethernet TCP/IP “Economy plus” Bus Terminal for up to 64 Bus Terminals
Controller for up to 64 Bus Terminals
Controller for up to 64 Bus Terminals
(255 with K-bus extension)
(255 with K-bus extension)
BC9000
BC9050
BC9020
64
64 (255 with K-bus extension)
512 byte input and 512 byte output 1,000 mA
1,750 mA
Bus Terminal
1,750 mA
513
The Bus Terminal Controller BC9000 is a Bus Coupler with integrated PLC functionality and has a fieldbus interface for Ethernet. It is an intelligent slave that can be used as a non-central intelligence in the Ethernet system. One unit consists of the Bus Terminal Controller, any number of terminals between 1 and 64, and a bus end terminal.
The “Compact” BC9050 Bus Terminal Controller with Ethernet interface extends the Beckhoff small controller series by a cost-optimised version in a compact housing.
The BC9020 “Economy plus” Bus Terminal Controller is a Bus Coupler with integrated PLC functionality and has a fieldbus interface for Ethernet. It is an intelligent slave and can be used as decentralised intelligence in the Ethernet system.
1 x RJ 45
1 x RJ 45
1 x RJ 45
10/100 Mbaud, automatic recognition
10/100 Mbaud, automatic recognition
10/100 Mbaud, automatic recognition of the transmission rate of the transmission rate of the transmission rate
64/96 kbytes
48 kbytes
128 kbytes
64/128 kbytes
32 kbytes
128 kbytes
4,080 bytes
2 kbytes
2 kbytes
– yes yes approx. 170 g approx. 100 g approx. 170 g
0…+55 °C
0…+55 °C
0…+55 °C
CE, UL, Ex, GL
CE, UL, Ex
CE, UL, Ex, GL www.beckhoff.com/BC9000 www.beckhoff.com/BC9050 www.beckhoff.com/BC9020 see page
608 see page
608 see page
608
FC90xx
706
FC90xx
706
FC90xx
706 see page
794 see page
794 see page
794
We reserve the right to make technical changes.
BECKHOFF New Automation Technology
Page 55
Ethernet
BC9120, BC9100
Ethernet | Bus Terminal Controller
Ethernet TCP/IP “Economy plus” Bus Terminal
Ethernet TCP/IP Bus Terminal Controller
Controller for up to 64 Bus Terminals (255 with for up to 64 Bus Terminals
K-bus extension, with integrated 2-channel switch)
(with integrated 2-channel switch)
Technical data
BC9120
BC9100
Number of Bus Terminals
64 (255 with K-bus extension)
64
Max. number of bytes
512 byte input and 512 byte output fieldbus Current supply K-bus
1,750 mA
1,750 mA +60 °C
Bus Terminal
-20 °C
514
In contrast to the BC9020, the BC9120 has an additional RJ 45 port. Both Ethernet ports operate as 2-channel switches.
The Bus Terminal Controller BC9100 is a Bus Coupler with integrated PLC functionality and has a fieldbus interface for Ethernet. The BC9100 is an intelligent slave and can be used as a non-central intelligence in the Ethernet system.
Bus interface
2 x RJ 45 (2-channel switch)
2 x RJ 45 (2-channel switch)
Data transfer rates
10/100 Mbaud, automatic recognition
10/100 Mbaud, automatic recognition of the transmission rate of the transmission rate
Program memory
128 kbytes
64/96 kbytes 64/128 kbytes
Data memory
128 kbytes
Remanent data
2 kbytes
4,080 bytes
Online change yes
–
Weight approx. 170 g approx. 170 g
Operating temperature
0…+55 °C
-20…+60 °C
Approvals
CE, UL, Ex, GL
CE, UL, Ex, GL
Further information www.beckhoff.com/BC9120 www.beckhoff.com/BC9100
Accessories Cordsets and connectors see page
608 see page
608
PC Fieldbus Cards
FC90xx
706
FC90xx
706
TwinCAT PLC see page
794 see page
794
BECKHOFF New Automation Technology
We reserve the right to make technical changes.
Page 56
BX9000, BC9191
Ethernet
Ethernet Room Controller Ethernet Bus Terminal Controller
Building Automation Room Controller for up to 64 Bus Terminals (255 with K-bus extension)
BX9000
BC9191
64 (255 with K-bus extension)
64 512 byte input and 512 byte output 350 mA
Bus Terminal
1,450 mA
515
The BX9000 Bus Terminal Controller has an Ethernet slave/master interface. The controller has automatic baud rate detection up to 100 Mbaud. The address can optionally be entered via DHCP, BootP, ARP or with the joystick switch.
Digital inputs: – 3 x 24 V DC Analog inputs: – 3 x 0…10 V; 1 x PT/Ni1000 (-20…+60 °C); 1 x resistance measurement for set value specification
RJ 45
2 x RJ 45 (switched)
10/100 Mbaud, automatic recognition
10/100 Mbaud, automatic recognition of the transmission rate of the transmission rate
256 kbytes
48 kbytes
256 kbytes
32 kbytes
2 kbytes
2 kbytes yes yes approx. 250 g approx. 375 g
0…+55 °C
0…+55 °C
CE, UL
CE www.beckhoff.com/BX9000 www.beckhoff.com/BC9191
Digital outputs: – 1 x 230 V AC, 10 A, relay; 3 x 230 V AC, 1 A, relay; 2 x 230 V AC, 1 A, triac Analog outputs: – 2 x 0…10 V see page
608 see page
608
FC90xx
706
FC90xx
706 see page
794 see page
794
For availability status see Beckhoff website at: www.beckhoff.com/BC9191
We reserve the right to make technical changes.
BECKHOFF New Automation Technology
Page 57
KLxxxx | Bus Terminals
Bus Terminal
The Bus Terminals have a galvanic isolation between the field level and the communication level (K-bus). A terminal is equipped with 1…n input or output channels. The channels within a terminal are usually not electrically isolated from each other.
516
The terminals are supplied with field voltage by the power contacts which are available on the left hand side, provided that the terminals have power contacts. Depending on the terminals 24 V DC, 230 V AC or other voltages are transferred by the power contacts. The supply power required for each terminal, which is provided through the power contacts, is listed in the technical data of each terminal. The maximum load of the power contacts is 10 A.
Beckhoff Bus Terminals feature function-dependant coloured labels: yellow for digital inputs, red for digital outputs, green for analog inputs, blue for analog outputs. The LED frames for HD Bus Terminals are also colourcoded accordingly.
Different field level connection techniques can be used for Bus Terminals: – standard terminal point: 0.08…2.5 mm2 spring force technology – HD Bus Terminal: 0.08… 0.75 mm² (with ferrule); 0.08…1.5 mm² (single-wire); spring force technology; direct plug-in technique – ribbon: especially used in Asia for digital input/output channels – plug-in wiring level: KS terminals
Some 2-channel Bus Terminals have a PE power contact, which can be used for PE distribution by connecting it together with similar terminals. The EMC spring contact on the underside of the terminal only serves to remove interference and may not be used as a protective earth . Technical data see page
BECKHOFF New Automation Technology
487
We reserve the right to make technical changes.
Page 58
2-channel terminals
4-channel terminals
8-channel terminals
16-channel terminals
The 2-channel terminals
Along with four channels
The 8-channel terminals have one
The HD (High Density) housing allows provide additional power the 4-channel terminals have channel per connection point due to
16 channels to be accommodated
(+24 V DC), ground (0 V DC)
another four connection points a high packing density. The power on a unit that is only 12 mm wide.
and in many cases also PE for available. These can provide contact of the terminal will be used
The power contact of the terminal each channel. Connection is
24 V DC or ground. Connec- as the common reference potential.
will be used as the common reference carried out with 3- or 4-wire tion is carried out with 2-wire
Connection is carried out with 1-wire potential. Connection is carried out connection.
connection.
connection.
with 1-wire connection.
various supply voltages. 1-, 2-, 3- and 4-wire connections allow the use of Bus Terminals in almost all applications without further wiring work. The KL3xxx and KL4xxx Bus Terminal product family processes analog signals. The most commonly used are 0…10 V, ±10 V, 0…20 mA and 4…20 mA. Also many other industry-standard voltage and current signals are supported and pre-processed. In the KL5xxx and KL6xxx Bus Terminal product families other complex signals, such as position values and digital interfaces, are supported. Some Bus Terminals act as fieldbus masters for subordinate bus systems. The Bus Terminal station thus becomes a universal gateway between different systems. The KL9xxx system terminals round off the application of Bus Terminals with power feed and power supply units.
The Bus Terminal system has stood the test of time in machine or building automation applications where a temperature range of 0 to +55 °C is sufficient. For requirements beyond that, the operating temperature range of selected standard Bus Terminals and couplers was extended to –20 to +60 °C. The storage temperature of these ET components (Extended Temperature Range) has also been adapted and is now -40 to +85 °C. The exact definition of the operating conditions in temperature ranges outside 0 to +55 °C, installation requirements that possibly deviate from the standard and, if applicable, deviating technical data can be found in the documentation. Bus Terminals which are suited to the extended temperature range are marked accordingly. +60 °C -20 °C
Technical data
KLxxxx | KSxxxx
Electrical isolation
500 V (K-bus/field voltage); is not indicated otherwise
Operating/storage temperature
0…+55 °C/-25…+85 °C (terminals with extended temperature range: -20…+60 °C/-40…+85 °C)
Relative humidity
95 %, no condensation
Vibration/shock resistance conforms to EN 60068-2-6/EN 60068-2-27/29
EMC immunity/emission conforms to EN 61000-6-2/EN 61000-6-4
Protect. class/installation pos.
IP 20/variable (see documentation)
www. beckhoff.com/BusTerminal We reserve the right to make technical changes.
BECKHOFF New Automation Technology
Bus Terminal
The Bus Terminals offer the possibility to directly connect many different signals. No signal converter or additional evaluation device is needed. The direct connection reduces the costs and simplifies the control technology. Each Bus Terminal separates the internal electronics from the connection level and thus simplifies the creation of voltage groups with different voltages. In addition, interfering voltages on the signal connector lose their adverse effects. The KL1xxx, KL2xxx Bus Terminal product family is designed for the processing of digital or binary signals. There are “High” and “Low” states. In the positive switching logic the High state corresponds to the level of the supply voltage, the Low state corresponds to ground level. For negative switching logic it is the other way around. The Bus Terminal product family supports both types of logic for
517
Page 59
Digital Input
KL1408, KL1418
Bus Terminal
Digital input | 24 V DC, positive switching The digital inputs of a 24 V supply are among the most used signals. The EN 61131-2 standard describes the input characteristic and distinguishes three types. Type 1 has a small input current with low power dissipation. This input is optimised for mechanical switches and activelyswitched electronic outputs. Type 2 has a significantly larger input current and is optimised for 2-wire sensors with a high quiescent current consumption. In switched-on state the current consumption of this input is high. The related power dissipation is generally not acceptable. Type 3 is a combination between type 1, with low current in switched-on state, and a satisfactorily high quiescent current for the majority of modern 2-wire sensors. The type 3 input can be used in almost all applications as a replacement for type 1.
The diagram shows the typical current/voltage curves of the Bus Terminal inputs and the allowable range of conformity in accordance with the standard. The input circuits differ in their filtering functions. The filtering has the task of suppressing electromagnetic interference. However, this does have the drawback of signal deceleration. The filter time of 3 ms is comparatively slow, but it can suppress the bouncing of a mechanical switch and delivers a stable signal for simple PLC applications. Filter times of 0.2 ms are suitable for applications with shortest possible reaction times and should be used for mechanical switches only in a restricted manner.
8-channel digital input terminal, 24 V DC, 1-wire, type 1/3 Technical data
KL1408 |
KL1418 |
KS1408
KS1418
Connection technology
1-wire
Specification
EN 61131-2, type 1/3
Input filter typ. 3.0 ms
Number of inputs
8 typ. 0.2 ms
+60 °C -20 °C
1
5
2
6
3
7
4
8
518
Type 1
Type 2
VIN /V 30
VIN /V 30
25
25
ON
20
15
10
10 5
5 0 −3
ON
20
15
The KL1408 and KL1418 digital input terminals have eight inputs, which are each assigned to a connection point. This way, a high packing density can be achieved for signal sources with common grounds.
OFF 0
10
5
15
I IN /mA
0 −3
OFF 0
5
10
15
Signal voltage “0”: -3…5 V DC
Signal voltage “0” -3…5 V DC
Signal voltage “1”: 15…30 V DC
Signal voltage “1”: 11…30 V DC
18 30
I IN /mA
Type 3 VIN /V 30 25
ON
20 15
24 V DC (-15 %/+20 %)
Current consumption typ. 2 mA + load power contacts
10 5 0 −3
Nominal voltage
OFF 0
5
10
15
I IN /mA
Signal voltage “0”: -3…5 V DC Signal voltage “1”: 11…30 V DC
Current consumpt. K-bus typ. 5 mA
Operating temperature
-20…+60 °C
Approvals
CE, UL, Ex, GL
Characteristics of the 3 input types
Weight approx. 55 g according to EN 61131-2 (24 V DC)
Further information www.beckhoff.com/KL1408
BECKHOFF New Automation Technology
We reserve the right to make technical changes.
Page 60
KL18xx, KL14xx
Digital Input
16-channel digital
8-channel digital input +
8-channel digital
4-channel digital
4-channel digital input terminal,
8-channel digital output, input terminal, input terminal, input terminal,
24 V DC, 1-wire,
24 V DC, 1-wire,
24 V DC, 2-wire,
24 V DC, 2-wire,
24 V DC, 2-wire, type 1/3 type 1/3 type 1/3 type 1/3 type 2
KL1859
KL1808
KL1809
KL1819
KL1404 |
KL1414 |
KS1404
KS1414
KL1434
2-wire EN 61131-2, type 2 typ. 3.0 ms typ. 3.0 ms typ. 3.0 ms
16
8 inputs + 8 outputs
8
4 typ. 0.2 ms typ. 0.2 ms 4
Type 2
1
9
1
9
1
9
2
10
2
10
2
10
3
11
3
11
3
11
4
12
4
12
4
12
5
13
5
13
5
13
6
14
6
14
6
14
7
15
7
15
7
15
8
8
16
The HD (High Density) Bus Terminals with higher packing density contain 16 terminal points housed in a 12 mm terminal block.
16
The KL1859 digital Bus Terminal combines eight digital inputs and eight digital outputs in one device. – – – – number of outputs: 8 max. output current: 0.5 A (per channel) load type: ohmic, inductive, lamp load reverse voltage protection: yes
8
5
1
5
2
6
2
6
3
7
3
7
4
8
4
8
519 Type 2
16
The KL1808 HD (High Density) Bus Terminal has eight inputs and eight 24 V connections, which are suitable for the connection of 2-wire sensors.
Type 2
1
Bus Terminal typ. 3.0 ms
The KL1404 and KL1414 digital input terminals are suitable for the connection of four 2-wire sensors.
Type 2
The KL1434 digital input terminal is suitable for the connection of four 2-wire sensors of type 2 (EN 61131-2).
24 V DC (-15 %/+20 %)
24 V DC (-15 %/+20 %)
24 V DC (-15 %/+20 %)
24 V DC (-15 %/+20 %)
24 V DC (-15 %/+20 %)
typ. 4 mA + load typ. 15 mA + load typ. 2 mA + load typ. 1 mA + load only load typ. 3 mA typ. 20 mA typ. 25 mA typ. 15 mA typ. 3 mA
0…+55 °C
0…+55 °C
0…+55 °C
0…+55 °C
0…+55 °C
CE, Ex
CE, Ex
CE, Ex
CE, UL, Ex, GL
CE, UL, Ex approx. 60 g approx. 60 g approx. 60 g approx. 50 g approx. 50 g www.beckhoff.com/KL1809 www.beckhoff.com/KL1859 www.beckhoff.com/KL1808 www.beckhoff.com/KL1404 www.beckhoff.com/KL1434
We reserve the right to make technical changes.