One-page Beckhoff data sheet for the KL2184, a 4-channel 24 V DC digital output Bus Terminal that switches to negative potential. It gives the technical data and the contact layout of the outputs and power contacts.

What it is
4-channel digital output Bus Terminal, 24 V DC, with four 0 V (ground) switching outputs p. 1
Rated load voltage
24 V DC (-15 %/+20 %) p. 1
Output current
0.5 A per channel, short-circuit-proof; short circuit current <7A p. 1
Load type
Ohmic, inductive, lamp load p. 1
Connection
2-/3-wire, with +24 V and 0 V power contacts p. 1
Operating temperature
0…+55 °C operating, -25…+85 °C storage; 95 % relative humidity, no condensation p. 1
Breaking energy
< 100 mJ/channel; reverse voltage protection p. 1
Electrical isolation
500 V (K-bus/field potential) p. 1
Current consumption
Power contacts typ. 30 mA + load; K-bus typ. 9 mA p. 1
Process image
4 outputs; no address or configuration setting p. 1
Indicators
One signal LED per channel p. 1
Protection class
IP 20, variable installation position p. 1
Weight
approx. 70 g p. 1
Pluggable version
KS2184 with pluggable wiring p. 1

What this manual walks you through

  • Contact layout of the four outputs and power contacts p. 1

Questions this manual answers

How much current can each KL2184 output carry?

Up to 0.5 A per channel; the outputs are short-circuit-proof. p. 1

Does the KL2184 switch to 24 V or to ground?

Its four outputs switch to 0 V (ground), that is to negative potential. p. 1

What loads can the KL2184 drive?

Ohmic, inductive and lamp loads at a rated 24 V DC. p. 1

What is the operating temperature of the KL2184?

0 to +55 °C in operation and -25 to +85 °C in storage. p. 1

The file

Size and text

Pages1
PDF816 KB
TextText from the PDF itself.

Every page · 1

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Beckhoff KL2184 Tech Manual

The text of page 1, from the PDF itself

Digital OutputKL2184Signal LED1Signal LED2Signal LED3Signal LED4Output 1Output 2

+24 V Power contact +24 V

0V Power contact 0 VOutput 3Output 4Top viewContact assembly

KL2184 | 4-channel digital output terminal 24 V DC, switching to negative potential The KL2184 digital output terminal connects the binary control signals from the automation unit on to the actuators at the process level with electrical isolation. The KL2184 version has four 0 V (ground) switching outputs and generates load currents with outputs that are resistant to overload and short-circuit. The Bus Terminal contains four channels that indicate their signal state by means of light emitting diodes. Technical data

KL2184 | KS2184Connection technology2-/3-wireNumber of outputs4Rated load voltage24 V DC (-15 %/+20 %)Load type

ohmic, inductive, lamp load

Max. output current

0.5 A (short-circuit-proof) per channel

Short circuit current<7ABreaking energy< 100 mJ/channel

Reverse voltage protection

yes

Electrical isolation

500 V (K-bus/field potential)

Current consumption power contacts

typ. 30 mA + load

Current consumpt. K-bus

typ. 9 mA

Bit width in the process image

4 outputs

Configuration

no address or configuration setting

Weight

approx. 70 g

Operating/storage temperature

0…+55 °C/-25…+85 °CRelative humidity95 %, no condensation

Vibration/shock resistance

conforms to EN 60068-2-6/EN 60068-2-27/29

EMC immunity/emission

conforms to EN 61000-6-2/EN 61000-6-4

Protect. class/installation pos.

IP 20/variable

Pluggable wiring

for all KSxxxx Bus Terminals

Approvals

CE, UL, Ex

BECKHOFF New Automation Technology

We reserve the right to make technical changes.