Page 73
Programming using MAC Programmer+
5.8 I/O change With the function I/O change you can change a single I/O or move a whole I/O area. You can change I/O in the whole project or only in the object that was marked when you selected the function. You can use the function on block in the block list, object in the graphic block and text block editor, lines in the alarm list, lines in the function key editor, lines in the LED editor or lines in the crossreference list. Select the function I/O change in the Edit menu.
Change I/O in Select if you want to change I/O in the whole project or for selected objects.
Change type Select if an I/O shall change place or if you want to move a whole I/O area.
From I/O, End I/O, To I/O State the I/O to be changed and what it should be changed to or which I/O area you want to move.
62
Page 74
Programming using MAC Programmer+
5.9 Change BDTP station With this function you can change the index numbering in a BDTP client project in a BDTP network. For example from station 1 to station 3. Select the function BDTP Station Change in the File menu.
Change station in
Select if you want to change the index numbering in the whole project or for selected objects. From station, To station
Enter the index number to be changed and to which BDTP station index number to be changed to. Confirm each change
Select if you want to confirm the change of BDTP station for each object.
63
Page 75
Programming using MAC Programmer+
5.10 I/O crossreference The function crossreference is used to document I/O in a clear way. Select the function I/O Crossreference in the View menu.
In the dialog displayed you state the Start I/O and End I/O. If you leave the Start I/O field empty, all I/O up to the value in the End I/O field will be included. If you leave the End I/O field empty, all I/O from the value in the Start I/O field will be included. If you leave both the fields empty all I/O in the list will be included.
Presentation The result of the function will be presented in a list with two levels. The first level shows used I/Os and how many objects that refer to respective I/O. You reach the second level when you double click on the + character to the left of the I/O. Now the objects containing the I/O you clicked on are displayed. The + character will become a - character. The button Print View opens the print dialog and you can select to print the crossreference list as it looks on the display to a connected printer.
64
Page 76
Programming using MAC Programmer+
One or several lines in the list can be copied and pasted into e.g. a Microsoft Word document.
5.11 Other editors The MAC Programmer+ also has editors for handling Function keys, LEDs, Alarms, Alarm groups, Passwords and Time channels. These editors are activated from the Functions menu. The editors work in a similar way. The parameters are described in separate chapters in this manual. Defined Function keys, LEDs, Alarms, Alarm groups and Time channels are displayed in a list in the editors respectively. Add a new definition with Append or Insert. If you want to change a definition, mark the alarm, make the changes and press Update. If you want to update or append more than one definition to the list, press Update or Append once and then press Enter. Thereafter Update or Append remain operational until changed. Erase a marked definition with Delete or Clear. End the editor with Exit. The following example describes the Alarms editor. The alarm is numbered automatically. When you press Append the alarm definitions is listed last, and when you press Insert the new definition will always be inserted before the marked definition in the list. When you press Update you confirm changes made on a definition.
65
Page 77
Programming using MAC Programmer+
5.12 The File Menu There are functions for creating, opening, saving and closing projects in the File menu. Printer settings, previewing print out, creating documentation headers and activating print out are also selected from here. Furthermore there are functions for testing a project and altering project settings. With the function MELSEC I/O Naming you select if the internal name list should be used or if a name file from MELSEC MEDOC or MELSEC MEDOC plus should be imported.
66
Page 78
Programming using MAC Programmer+
5.13 The Edit Menu Functions for cutting, copying, pasting, undo and select all are found in the Edit menu.
5.14 The View Menu Function editor for block editing, symbol handling, crossreference and name list are to be found in the View menu.
Block List Blocks included in the application are shown in the block list. In the block list you create new blocks by pressing the button New. Basic parameters for the block are defined in the block header.
67
Page 79
Programming using MAC Programmer+
Block Manager Blocks included in the application are shown in the Block Manager graphically. In the Block Manager you create new blocks, define the block header, define block jump with the functions in the toolbox.
Symbol Manager Activates the symbol manager. In the symbol manager you create a library of symbols in BMP format. The symbols in the symbol manager are then available in the symbol list when you create static and dynamic symbol objects. It is also possible to duplicate and edit defined symbols.
I/O Crossreference Under I/O Crossreference you document I/O in a clear way. See the section I/O Crossreference in this chapter.
Name list Under Name list you define a local name list for used devices. Devices used in the project without defined name can be inserted in the name list with the function Undefined. New devices can be added and existing names can be edited and updated. With the function Rebind you update the project with the changes done in the name list. A name list can be exported to a text file and a text file can be imported to a name list. The items in the file is separated either with the character →, ; or ,. An internal name list can be sorted. The text file may not include national characters. Note! In the function MELSEC I/O Naming in the File menu you must choose Internal name list to use the name list.
68
Page 80
Programming using MAC Programmer+
If you have created a local name list in your project you can choose I/O signals from this name list via the I/O button. Click on the button I/O in all instances where you want to enter an address. The I/O browser has incremental searching. Incremental searching means that searching begins immediately while you are still entering characters in the name/device. The I/O list is stated in device order or name order.
If you have linked a driver specific name file to your project you can choose I/O signals from this name file via the I/O button.
69
Page 81
Programming using MAC Programmer+
Controller I/O The button I/O in the I/O browser can give you heop with addressing different PLC-systems.
Note! The function Controller I/O is not supported by all PLC-systems.
5.15 The Functions Menu Function editor for function keys, LED, alarm, time channels, passwords and message libraries are to be found in the Function menu.
Function keys Under Function keys you define global and local function keys. See the chapter Function keys.
LED Under LED you define the function for the LEDs. See the chapter LEDs.
70