Page 282
Expansions card
22 Expansions card The chapter is not valid for E50, E100 and E200. In the terminals there is a possibility to connect different expansion cards to increase the communication possibilities.
22.1 IFC PBDP With the expansion card IFC PBDP the terminal can be connected to and communicate as a slave with a Profibus network. For information about how to setup the card, see the manual for the product. For information about how to configure a Profibus network, see the manual for Profibus network.
22.2 IFC MC With the expansion card IFC MC you can connect a PCMCIA memory card to the terminal. You can select to use the memory card to expand the project memory, use it as backup or for moving files between terminals. For further information we refer to the manual for IFC MC.
22.3 IFC 128E IFC 128E is an expansion card for connection of external function keys or switches. Up to 128 external function keys/switches can be used. For further information see the manual for the product.
22.4 IFC ETTP and IFC ETCX The expansion cards IFC ETTP and IFC ETCX are cards for network comunication using TCP/IP via a twisted cable or coaxial cable. For further information, see the manual for IFC ETTP and IFC ETCX.
271
Page 283
Expansions card
22.5 IFC PI IFC PI is an expansion card which makes it possible to connect a printer with parallel connection to the terminal. The RS-232 port on the expansion card can not be used for external communication. For further information see the manual for IFC PI.
272
Page 284
Project transfer
23 Project transfer The project must be transferred from the PC to the terminal, in order to be used in the terminal. Connect the PC with MAC Programmer+ to the terminal via the cables MAC-PROG/9-CAB or CAB6.
Personal computer Terminal RS-422
RS-232
MAC-PROG/9-CAB
Personal computer Terminal RS-422
RS-232
CAB6
Note! Driver and system program are also transferred when a project is transferred to E50. All communication between a PC and E50 is made via MAC Programmer+.
273
Page 285
Project transfer
23.1 Terminal settings The transfer parameters are set in the terminal in Setup mode under Setup, Port Parameters, MAC Programmer+. Note! The communication settings must be the same in the PC software as in the terminal.
23.2 Transfer settings The transfer is controlled from the MAC Programmer+. In the menu Project Transfer you can select what is to be transferred.
274
Page 286
Project transfer
Parameter
Description
Percent complete
Shows the status of the transfer during transfer.
Byte count
Shows the number of bytes transferred during transfer.
Time elapsed
Shows elapsed time since one of the function’s send, receive or verify was activated.
Status
Shows which part of the project that is transferred. For example Setup, block, alarm groups, symbols and function keys.
Info
Display the defined driver that will be send to the terminal.
Retries
When the transfer fails, the MAC Programmer+ makes a number of retries before the transfer is shut down.
Terminal version
When contact is enabled with the terminal, current terminal type and program version are displayed here.
Test project on send
Tests automatically the project before transfer.
Automatic terminal RUN/Transfer switching
The terminal is automatically put in transfer mode and will return to the previous mode after transfer.
Check terminal version
Checks the terminal version and gives a warning if the project and the terminal don’t match.
Send complete project
Select if you want to transfer the whole project.
Partial send options
None: All: From To:
Delete
Trend data: Delete all stored trend data in the terminal. Recipe data: Delete all stored recipe data in the terminal.
No blocks are sent to the terminal. All blocks are sent to the terminal. State an interval of blocks to be sent to the terminal. Alarms: Select if alarms shall be sent to the terminal. Symbols: Select if symbols shall be sent to the terminal. Time channels Select if time channels shall be sent to the terminal. LED’s Select if LED’s shall be sent to the terminal. Message library Select if message library shall be sent to the terminal. Setup Select if the setup shall be sent to the terminal. Function keys Select if function keys shall be sent to the terminal. Passwords Select if passwords shall be sent to the terminal.
275
Page 287
Project transfer Parameter
276
Description
Download driver
Never: Always: Automatic:
Driver will never be downloaded. Driver will always be downloaded. Driver will be downloaded to the terminal when the driver in the terminal and the driver defined in current project are not the same. These parameters are valid for both driver and system program for E50.
Set terminal clock
The clock in the personal computer will be sent to the terminal.
Send
Transfer the project to the terminal according to current settings.
Receive
The MAC Programmer+ loads the project in the terminal. Current project in the MAC Programmer+ will be overwritten.
Verify
Compares the project in the MAC Programmer+ with the project in the terminal.
Stop
Interrupt the transfer.
Settings
Select if TCP/IP transfer or Serial transfer. If you select TCP/IP transfer no further settings is necessary. If you select Serial transfer the parameters described in the table below must be stated.
Page 288
Project transfer The communication parameters are set under Comm Settings in the Transfer menu or by choosing Settings in the Project Transfer dialog. Parameter
Description
Use TCP/IP transfer
Select if the project shall be transferred via TCP/IP.
Use serial transfer
Select this if you will use serial transfer of the project.
Port
Select communication port.
Baudrate
Baudrate (bits/second).
Timeout
Number of milliseconds between retries.
Retries
Number of retries before the transfer is shut down.
Parity
Select type of parity control.
Databits
Select number of data bits. Must be 8 bits.
Stopbits
Select number of stop bits.
Speed set manually
Used when communication via a modem. You must set the baudrate in the terminal and PC software manually and they must be the same.
Note! Communication can fail if other programs are running under Windows at the same time as the transfer takes place. Failure is avoided by shutting down the other programs. During block transfer, links to relevant symbols are included. If the symbols are not transferred, problems may occur.
277
Page 289
Project transfer
23.3 TCP/IP transfer When transferring via TCP/IP you need to select Use TCP/IP transfer in the Comm Settings dialog in the Transfer menu. When you press Send in the Project transfer dialog the following dialog is shown.
Host address State the IP address of the terminal you want to transfer to. Terminal Control port State the TCP/IP-port number for RUN/TRANSFER switching. Need normally not to be changed. Default is 6001. Transfer port State the TCP/IP-port number for transferring. Need normally not to be changed. Default is 6000. User ID State a username used during RUN/Transfer switching authentication. Not needed if the terminal is already in transfer mode. Password State a password used during RUN/Transfer switching authentication. Not needed if the terminal is already in transfer mode. Save password in project Saves the password and user id so that you don’t need to enter it next time.
278
Page 290
Project transfer
23.4 Serial transfer When serial transfer is used you need to select Use serial transfer in the Comm Settings dialog in the Transfer menu. When you press Send in the Project Transfer dialog the project will be sent to the terminal.
23.5 Transfer via modem Settings when using modem communication between a PC and an operator terminal.
Modem settings Make the settings on the modem connected to the operator terminal as follows: AT &F E0 Q1 &D0 &K0 &W Make the settings on the modem connected to the PC as follows: AT &F &D0 &K0 &Q0 &W The table below describes the modem commands. Command
Description
AT
Inform the modem that a command follows. Each command shall be proceeded by AT.
&F
Load the default settings
E0
Echo off
Q1
Command answer off
&D0
The modem ignore the DTR signal
&K0
No flow control
&Q0
Direct asynchronous mode
&W
Save settings
279
Page 291
Project transfer
Communication at selectable speed 1. Configure the modem. 2. Make the communication settings in the Comm settings dialog under Transfer in MAC Programmer+.
3. Set Baudrate, parity, data bits, stop bits and select Speed set manually. 4. Set the communication parameters in the terminal in the same way as in the MAC Programmer+ (Setup – Port parameters – MP) 5. Set the terminal in Transfer mode. 6. Use HMI Tools Modem program to make the call up.
280
Page 292
Project transfer 7. Then you select Transfer in MAC Programmer+.
Don’t select Automatic terminal RUN/TRANSFER switching.
281
Page 293
Project transfer
Automatic transfer 1. Configure the modem. 2. Make the communication settings in the Comm settings dialog under Transfer in MAC Programmer+. The baudrate must be 2400 baud.
3. Use HMI Tools modem program to make the call up.
282
Page 294
Project transfer 4. Then you select Transfer in MAC Programmer+.
Note! If Auto terminal RUN/TRANSFER switching is used the baudrate must be set to 2400 baud.
283
Page 295
Project transfer