Page 282

Expansions card

22 Expansions card The chapter is not valid for E50, E100 and E200. In the terminals there is a possibility to connect different expansion cards to increase the communication possibilities.

22.1 IFC PBDP With the expansion card IFC PBDP the terminal can be connected to and communicate as a slave with a Profibus network. For information about how to setup the card, see the manual for the product. For information about how to configure a Profibus network, see the manual for Profibus network.

22.2 IFC MC With the expansion card IFC MC you can connect a PCMCIA memory card to the terminal. You can select to use the memory card to expand the project memory, use it as backup or for moving files between terminals. For further information we refer to the manual for IFC MC.

22.3 IFC 128E IFC 128E is an expansion card for connection of external function keys or switches. Up to 128 external function keys/switches can be used. For further information see the manual for the product.

22.4 IFC ETTP and IFC ETCX The expansion cards IFC ETTP and IFC ETCX are cards for network comunication using TCP/IP via a twisted cable or coaxial cable. For further information, see the manual for IFC ETTP and IFC ETCX.

271

Page 283

Expansions card

22.5 IFC PI IFC PI is an expansion card which makes it possible to connect a printer with parallel connection to the terminal. The RS-232 port on the expansion card can not be used for external communication. For further information see the manual for IFC PI.

272

Page 284

Project transfer

23 Project transfer The project must be transferred from the PC to the terminal, in order to be used in the terminal. Connect the PC with MAC Programmer+ to the terminal via the cables MAC-PROG/9-CAB or CAB6.

Personal computer Terminal RS-422

RS-232

MAC-PROG/9-CAB

Personal computer Terminal RS-422

RS-232

CAB6

Note! Driver and system program are also transferred when a project is transferred to E50. All communication between a PC and E50 is made via MAC Programmer+.

273

Page 285

Project transfer

23.1 Terminal settings The transfer parameters are set in the terminal in Setup mode under Setup, Port Parameters, MAC Programmer+. Note! The communication settings must be the same in the PC software as in the terminal.

23.2 Transfer settings The transfer is controlled from the MAC Programmer+. In the menu Project Transfer you can select what is to be transferred.

274

Page 286

Project transfer

Parameter

Description

Percent complete

Shows the status of the transfer during transfer.

Byte count

Shows the number of bytes transferred during transfer.

Time elapsed

Shows elapsed time since one of the function’s send, receive or verify was activated.

Status

Shows which part of the project that is transferred. For example Setup, block, alarm groups, symbols and function keys.

Info

Display the defined driver that will be send to the terminal.

Retries

When the transfer fails, the MAC Programmer+ makes a number of retries before the transfer is shut down.

Terminal version

When contact is enabled with the terminal, current terminal type and program version are displayed here.

Test project on send

Tests automatically the project before transfer.

Automatic terminal RUN/Transfer switching

The terminal is automatically put in transfer mode and will return to the previous mode after transfer.

Check terminal version

Checks the terminal version and gives a warning if the project and the terminal don’t match.

Send complete project

Select if you want to transfer the whole project.

Partial send options

None: All: From To:

Delete

Trend data: Delete all stored trend data in the terminal. Recipe data: Delete all stored recipe data in the terminal.

No blocks are sent to the terminal. All blocks are sent to the terminal. State an interval of blocks to be sent to the terminal. Alarms: Select if alarms shall be sent to the terminal. Symbols: Select if symbols shall be sent to the terminal. Time channels Select if time channels shall be sent to the terminal. LED’s Select if LED’s shall be sent to the terminal. Message library Select if message library shall be sent to the terminal. Setup Select if the setup shall be sent to the terminal. Function keys Select if function keys shall be sent to the terminal. Passwords Select if passwords shall be sent to the terminal.

275

Page 287

Project transfer Parameter

276

Description

Download driver

Never: Always: Automatic:

Driver will never be downloaded. Driver will always be downloaded. Driver will be downloaded to the terminal when the driver in the terminal and the driver defined in current project are not the same. These parameters are valid for both driver and system program for E50.

Set terminal clock

The clock in the personal computer will be sent to the terminal.

Send

Transfer the project to the terminal according to current settings.

Receive

The MAC Programmer+ loads the project in the terminal. Current project in the MAC Programmer+ will be overwritten.

Verify

Compares the project in the MAC Programmer+ with the project in the terminal.

Stop

Interrupt the transfer.

Settings

Select if TCP/IP transfer or Serial transfer. If you select TCP/IP transfer no further settings is necessary. If you select Serial transfer the parameters described in the table below must be stated.

Page 288

Project transfer The communication parameters are set under Comm Settings in the Transfer menu or by choosing Settings in the Project Transfer dialog. Parameter

Description

Use TCP/IP transfer

Select if the project shall be transferred via TCP/IP.

Use serial transfer

Select this if you will use serial transfer of the project.

Port

Select communication port.

Baudrate

Baudrate (bits/second).

Timeout

Number of milliseconds between retries.

Retries

Number of retries before the transfer is shut down.

Parity

Select type of parity control.

Databits

Select number of data bits. Must be 8 bits.

Stopbits

Select number of stop bits.

Speed set manually

Used when communication via a modem. You must set the baudrate in the terminal and PC software manually and they must be the same.

Note! Communication can fail if other programs are running under Windows at the same time as the transfer takes place. Failure is avoided by shutting down the other programs. During block transfer, links to relevant symbols are included. If the symbols are not transferred, problems may occur.

277

Page 289

Project transfer

23.3 TCP/IP transfer When transferring via TCP/IP you need to select Use TCP/IP transfer in the Comm Settings dialog in the Transfer menu. When you press Send in the Project transfer dialog the following dialog is shown.

Host address State the IP address of the terminal you want to transfer to. Terminal Control port State the TCP/IP-port number for RUN/TRANSFER switching. Need normally not to be changed. Default is 6001. Transfer port State the TCP/IP-port number for transferring. Need normally not to be changed. Default is 6000. User ID State a username used during RUN/Transfer switching authentication. Not needed if the terminal is already in transfer mode. Password State a password used during RUN/Transfer switching authentication. Not needed if the terminal is already in transfer mode. Save password in project Saves the password and user id so that you don’t need to enter it next time.

278

Page 290

Project transfer

23.4 Serial transfer When serial transfer is used you need to select Use serial transfer in the Comm Settings dialog in the Transfer menu. When you press Send in the Project Transfer dialog the project will be sent to the terminal.

23.5 Transfer via modem Settings when using modem communication between a PC and an operator terminal.

Modem settings Make the settings on the modem connected to the operator terminal as follows: AT &F E0 Q1 &D0 &K0 &W Make the settings on the modem connected to the PC as follows: AT &F &D0 &K0 &Q0 &W The table below describes the modem commands. Command

Description

AT

Inform the modem that a command follows. Each command shall be proceeded by AT.

&F

Load the default settings

E0

Echo off

Q1

Command answer off

&D0

The modem ignore the DTR signal

&K0

No flow control

&Q0

Direct asynchronous mode

&W

Save settings

279

Page 291

Project transfer

Communication at selectable speed 1. Configure the modem. 2. Make the communication settings in the Comm settings dialog under Transfer in MAC Programmer+.

3. Set Baudrate, parity, data bits, stop bits and select Speed set manually. 4. Set the communication parameters in the terminal in the same way as in the MAC Programmer+ (Setup – Port parameters – MP) 5. Set the terminal in Transfer mode. 6. Use HMI Tools Modem program to make the call up.

280

Page 292

Project transfer 7. Then you select Transfer in MAC Programmer+.

Don’t select Automatic terminal RUN/TRANSFER switching.

281

Page 293

Project transfer

Automatic transfer 1. Configure the modem. 2. Make the communication settings in the Comm settings dialog under Transfer in MAC Programmer+. The baudrate must be 2400 baud.

3. Use HMI Tools modem program to make the call up.

282

Page 294

Project transfer 4. Then you select Transfer in MAC Programmer+.

Note! If Auto terminal RUN/TRANSFER switching is used the baudrate must be set to 2400 baud.