Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual · part 6 of 28

Troubleshooting Nuclear Instruments, pages 51 to 60

Pages 51 to 60 of 273

The original document is the PDF (12 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Camac Output register Driver CAMAC

Page 51

Chapter 3

-353.3.17

Break-Out Box

A tester for V24, RS-232 interfaces

The instrument is inserted into the RS-232 link. LEDs show the status of each line. With UlP-switches each line can be interrupted and arranged, also a low or high level can be applied. A delay of two adjustable times is possible for each signal. Such economic instruments are recommended of serial interfaces.

for fast troubleshooting

ABC

(55)

Page 52

Chapter 3 3.3. 20

-36Prom Programmer suitable for programming Proms of the type 2716 to 27512 serial and parallel interfaces 512 k-bit memory

RAM internal

The c a p a b i l i t i e s of such an instrument are: p r o g r a m m i n g (4 programming algorithms) e d i t i n g (e.g. e d i t i n g the buffer RAM) CPU communication (operation from a host c o m p u t e r ) e m u l a t i o n (transfer d a t a from b u f f e r RAM to optional emulator module ) i n t e r f a c e to an external device (RS-232, Centronics)

3 a d a p t o r s for copying d i f f e r e n t types of E-Proms

2 adaptors mainly used for m u l t i p l e copying of E-Proms (gang-programming)

Some Prom-programmers on the Bi-polar devices and PALs.

market are also able to program

But normally, PAL-circuits are protected and therefore no copying is possible (spare PAL circuits have to be ordered from the manufacturer).

(56)

Page 53

-37-

Chapter 3

The Prom Programmer described requires for E-Proms a personality module for the individual Prom families to be p r o g r a m m e d . Especially with new devices, it takes some time until such cards become available from the manufacturer and sometimes even a m o d i f i c a t i o n to the basic instrument is necessary to provide the required features. New Prom Programmers which are now available allow programming of the i n d i v i d u a l parameters for burning a device into their memory and are therefore more flexible. Personality cards for these i n s t r u m e n t s are not necessary.

(57)

Page 54

Chapter 3

3.4

-38-

RECOMMENDED ELECTRONIC COMPONENTS

Below is a list of spare parts and electronic components that are considered to represent an optimal store for a medium large electronics service laboratory. The last column in the catalogue n u m b e r refers to a large mail house in the FRG (Fa. Buerklin, P.O. Box 200440, 8000 M u n i c h , FRG). The value of these components is a b o u t US$ 4.000.-. By adjusting the number of ordered components, a less or more expensive stock can be acquired. Item

Quant i t y

Description

Cat.

No

Resistors

1 2 3 4 5

50 50 50 50 100

6 7 8 9 10

M e t a l resistor

1ROO 3R32 5R90 6R81 10RO

31E710 31E760 31E778 31E781 30E100

100 100 100 100 100

33R2 51R1 75RO 100R 475R

30E150 30E168 30E184 30E196 30E261

11 12 13 14 15

200 100 200 200 200

1KOO 3K48 10KO 100K 1MOO

30E292 30E345 30E389 30E485 30E582

16 17 18 19 20

50 50 1 5 5

3M90 10MO Service Sortiment, CCR-011R Resistor 5W.OR33 OR47

30E645 30E695 27E230 62E112 62E116

21 22 23 24 25

5 5 3 3 3

Resistor network

26 27 28

3 20 20

Varistors

OR68 1RO

10W.MR1 MR2 MR3

62E118 62K124 37E900 37E905 37E910

MR4

37E919 82E2255 82E2235

6.8uF,16V 6.8uF,35V

26D479 26D600

275VAC.1W 150VAC,1W

Capacitors, coils

29 30

(58)

50 50

Tantal capacitor

Page 55

Chapter 3

-39lOuF, 16V 10uF,35V 22uF, 16V 22uF,35V 47uF, 16V

26D480 26D605 27D524 27D568 27D528

31 32 33 34 35

50 50 50 50 50

36 37 38 39 40

50 1 50 50 50

41 42 43 44 45

50 50 50 50 50

46 47 48 49 50

50 50 20 20 20

10nF,40V 1 OOnF,50V Ceramics, high vol. lOpF, 3kV 100pF,3kV 22pF,3kV

59D250 53D661 61D300 61D324 61U308

51

20

61D352

52 53 54 55 56

20 20 20 20 20

10nF,3kV 10uF,6kV Styroflex capacitor 470pF , 160V lOOOpF, 160V lOOOOpF, 160V HF-coil 22uH lOOuH

47uF,35V Service S o r t i m e n t , CCC-001 1000uF,40V Electrolytic cap. 2200uF,40V 4700uF ,40V

27D572 28D810 11D315 11D320 11D325

10000uF,25V 10pF,63V 1 OOpF,63V 470pF,63V lnF,63V

11D274 59D162 59D174 59D182 59D200

Ceramics cap.

49D304 49D308 49D314 74D316 74D324

Potent iome t ers

57 58 59 60

10 10 10 10

Potent iome t er

IK 4K7 22K 100K

68E223 68E225 68E227 68E229

61 62 63 64 65 66

5 3 3 3 3 3 lOturn p o t e n t i o m e t e r , IK 2K 5K 10K 100K Dial

67E853 67E854 67E855 67E856 67E860 20H712

Transistors and linear integrated circuits 67 68 69 70

10 10 10 10

JFET, 2N4416

2N4861 2N3819 2N3823

27S7700 27S8300 27S4700 27S4850

(59)

Page 56

Chapter 3

-40-

100 100 20 10 10

Bipolar Transistor, 2N3904 2N3906 Transistor, BFY90 Comparator, LM710 LM711

27S5200 27S5300 17S4000 41S5300 41S5350

10 10 10 10 10

LM311D Operational amplifier, LM741CD LM748CD LM318D LM324D

41S2290 41S5380 41S5405 41S2575 41S3175

10 10 10 10 20

LF356N LF357N TL071CP CA3140E Voltage regulators, LM723CD

40S9000 40S9060 49S5500 40S2950 41S5370

10 10 10 10 10

UA7805CKC UA7812CKC UA7824CKC UA7905CKC UA7912CKC

50S1450 50S1600 50S1750 50S1800 50S1950

10 20 20 10 10

UA7924CKC LM317T LM337T LM340K12 Darlington Transistor, BD651

50S2100 41S2550 41S3600 41S3750 14S6150

10 5 5 5 5

Power Power Power Power

BD652 Transistor, 2N3055S switching Tr. MJE3055 HV Transistor, BU208 switching MOS FET BUZ80

14S6200 27S2500 24S4900 19S2950 19S6800

5 20 20 20 20

Power Transistor, TI.P33F npn Transistor 2N2219A pnp Transistor 2N2905A npn Transistor, 2N2222A pnp Transistor, 2N2907A

25S2875 27S1100 27S1950 27S1250 27S2150

10 10 5 npn Transistor, BD139-16 pnp Transistor, BD140-16 Thyristor, 2N4441

13S5300 13S5500 27S7800

Diodes , zener diodes 109 110 111 112 113 114 115

(60)

50 100 20 5 3 5 10

Diode, 1N4007 1N4148 1N5408 Bridge rectifier

3A.600V 10A.500V

Switching diode, MR854 Zener diode ZPD 5 . 1

26S8100 26S8150 26S8876 55A658 57A190 24S4910 25S8000

Page 57

Chapter 3

-41116 117 118 119 120

10 10 10 10 10

ZPD ZPD ZPD ZPD ZPD

5.6 6.8 8.2 10 12

25S8050 25S8150 25S8250 25S8350 25S8450

121 122 123

10 10 10

ZPD 15 ZPD 24 ZPD 33

25S8550 25S88UO 25S8950

Servicesortiment, fast slow Precise fuse

0. 1A 0.4A 1.6A

46G240 46G244 46G268 46G274 46G280

4A 0.4A 1.6A 4A

46G284 46G319 46G325 46G329

Fuses

124 125 126 127 128

1 1 20 20 20

129 130 131 132

20 20 20 20 s low,

Soldering supplies

133 134 135

5 5 5

FLUITIN soldering wire, 100g, 0.7 5mm 11L402 Desoldering wire, 1 . 3mm 10L752 2 . 5mm 10L756

Connectors and cables

136 137 138 139 140

5 5 20 3 3

BNC extension connector BNC, T BNC, cable plug NIM connector, male NIM connector, female

78F270 78F290 78F200 55F7251 55F7253

141 142 143 144 145

50 50 100 100 6

Centering pin Centering recept ors Contact pins Contact receptor s Protecting cover

55F760 55F766 55F7725 5 5F77 8 55F798

146 147 148 149 150

3 3 3 3 300

Connector ,

Pins

55F400 55F401 55F410 55K412 55F408

151 152 153 154 155

300 25m 10m 20m 10m

Pins Cable RG58C/U RG59B/U Cable , 5pol Flat cable , 50po 1

55F418 96F730 96F746 94F306 94F439

9pol , male 25pol , male 9pol , female 25pol , female

(61)

Page 58

Chapter 3

-42-

ü i g i t a l i n t e g r a t e d circuits 156 157 158 159 160

50 5Ü 50 50 50

SN74LSOON

161 162 163 164 165 166

20 20 20 20 10 10

SN74LS138N SN74LS123N SN74LS191N SN74LS193N SN74LS374N SN74LS245N

43S5900

LED,

67S4350 67S4450 67S4500

SN74LS02N SN74LS10N SN74LS74AN SN74LS90N

43S2750 43S2900 43S3250 43S4600 43S4950

43S5550 43S7150 43S7250 43S9900 43S7800

LEDs 167 160 169 170

20 20 20 20

3 m m , red 3mm , green 5mm , red 5mm, green

67S4600

Swi t ehe s 171 172 173

5 5 5

S w i t c h , Ipol, E-E 2pol, E-E 2pol, E-A-E

10G700 10G740 10G750

Miscellaneous 174 175 176 177 178 179 180

(62)

1 set 1 set 1 1 pak . 2 2 10

Screws

16H695 16H954 80B533 12H592 46G628

Nuts Heat conducting paste Wire wrap pins Fuse h o l d e r , 5x2 Omm 6.3x31. 7mm

46G642

IC-breakable sockets

16B110

Page 59

-43-

SKILLS :

Chapter 3

R e a d i n g and U n d e r s t a n d i n g of Circuit Diagrams

Diagrams are the main aids to repair. For fault location the most essential information is t h a t concerning functional s t r u c t u r e , i.e. how the components are connected to perform their required f u n c t i o n . C i r c u i t diagrams are o f t e n c r i t i c i z e d on the basis of bad p r e s e n t a t i o n ; due to t h i s , national s t a n d a r d s were d e v e l o p e d to specify the r e q u i r e m e n t s for an e f f i c i e n t diagram. A c c o r d i n g to B r i t i s h S t a n d a r d : "Diagrams should be drawn so that the main sequence of c a u s e - t o - e f f e c t goes from left to r i g h t , and/or from top to b o t t o m . The input should always be on the l e f t , and t lie o u t p u t on the r i g h t . When this is i m p r a c t i c a l , the d i r e c t i o n of operation should be shown by an arrow. Components a s s o c i a t e d w i t h each operational stage should be grouped together." U n f o r t u n a t e l y , really good c i r c u i t diagrams are still rare. It is o f t e n said that the after-sales policy of the manufacturer is mirrored in the diagrams. Some companies prefer to give repair services and they d i s t r i b u t e almost useless circuit diagrams to scare away n o n - f a c t o r y approaches to maintenance. The s t a n d a r d i z a t i o n of the graphic symbols for components is much more e f f i c i e n t ; however, some companies still use their own local s t a n d a r d s in 'the nuclear field. The same applies to cable connection notations and markings. There is no general rule; each company has its own g r a p h i c symbols in m u l t i - s h e e t diagrams for i n t e r c o n n e c t i o n s , test p o i n t s , e t c . During repair work, correct reading of the graphic symbols is essential. This should be t e s t e d very carefully; even a single m i s t a k e in identifying the symbols indicates further learning requirements. The next step is to test ones' colour code reading c a p a b i l i t i e s . For e f f i c i e n t repair work, one should acquire a faultless reading c a p a b i l i t y with a rate of ten items per minute. Colour b l i n d n e s s i n h i b i t s the c o r r e c t i d e n t i f i c a t i o n of resistor values. This can be r a t h e r dangerous in repair work and it should be avoided by employing personnel without this deficiency. It is very important to be able to locate certain components on the c i r c u i t board from the circuit diagram and vice versa. Skills can be quickly developed by training. An a c c e p t a b l e level is d e m o n s t r a t e d by being able to c o r r e c t l y locate ten components, b o t h ways, in ten m i n u t e s . The c a p a b i l i t y to locate components running at high voltage is a needed skill in nuclear instrument repairs. The repair personnel should be able to correctly mark with red pencil all high voltage lines and c o m p o n e n t s on the diagram within 30 m i n u t e s , and they should be able to locate the same in the i n s t r u m e n t as well. In many systems, interlocks, fuses, and thermo-switches might inhibit o p e r a t i o n due to present or past hazard situations. Often

(63)

Page 60

Chapter 3

-44- they are connected to logic c i r c u i t s , timers, e t c . The technic ians should be able to correctly identify such circuits w i t h i n ten minutes Circuits can be inoperative because of faulty switch functions. It is important to be able to identify which circuit points should be connected together to secure operation and which lines should be c u t . Such decisions should be c o r r e c t l y made w i t h i n five minutes.

Signal propagation determination is very important. This can be a c o m p l i c a t e d task. The general rule is to find each active components inputs and o u t p u t s . This requires f a m i l i a r i t y with the 1C pin configurations: location of the power inputs and signal lines. It is not i m p o r t a n t to memorize these pins, however. In two minutes time one should be able to list the e x p e c t e d voltage levels and signals on a 14-pin 1C, after looking on its diagram and the s p e c i f i c a t i o n s in the catalogue.

A nuclear electronics service man should be able to discriminate between filtering c i r c u i t s around the power lines and frequency characteristics d e t e r m i n i n g components round amplifiers. They should be able to correctly group such components at a rate of four items per m i n u t e . In some circuits the feedback loops are rather elaborated. However, they should be correctly identified as the time limit is one hour.

The real test of "understanding" a circuit is electronician can prepare a correct functional diagram circuit.

if of the the

The general rules for producing functional diagrams are: the main signal flow must be from left to right; the signal flow must be emphasized; this can be done by showing flow paths in a straight line, avoiding crossover of flow paths; arrows may be used to avoid ambiguity;

indicate direction of flow, only to main inputs must be on the left and outputs on the right; the source of all inputs and the destination of all outputs must be shown; all plugs, sockets, controls, test points and terminals useful in troubleshooting must be shown and referenced; normal state measurements for all test points must be available ;

symbols must be according to local standards. It is a good practice to mark points where stages can be isolated from each other, with indication of possible test signals and expected correct outputs.

(64)