Page 1

New Products

New Product

Air operated 2 port valve (cylinder valve) SAB/SVB Series 2 PORT AIR OPERATED VALVE

CC-770A 4

Page 2

2 P O RT A I R O P E R AT E VA LV E

SAB SVB Series •

Small,Smart

Achieving higher energy saving performance and ultimate compact size SAB/SVB Series Ultimate compact size is realized in "Small" and "Smart" concept. Incorporating new flow path in the body, remarkably compacts actuator with conventional products performance is now available.

Pre cise and mea

Compact and energy saving sure

Se mic on du

Fo o men t, et c d cto r

Actuator Volume Approximate max.

Operation air consumption reduced by 40% maximum (*1) Actuator size (volume) reduced by 50% maximum (*1)

Air consumption Approximate max.

*1. Comparison with conventional NAB Series *2. Excluding port size 65F and 80F

Au to

*My body face to face dimensions have conventional products NAB series and compatibility.

learance

Same c mo

Ma

Compact/energy saving actuator bile chi ne

Power consumption reduced by Low wattage coil

Wide variation

Freely combined to any 4 directions

Two types of body material (bronze and stainless steel) and 4 types of sealant (nitrile rubber, fluoro rubber, ethylene propylene diene rubber and tetrafluoroethylene resin) are available in accordance with working fluid. 13 types of port size, 3 types of actuation are available, and solenoid valve integrated type to drive cylinders are also available.

MPa MADE IN JAPAN istr

Free actuator installation attitude

Safe and reliable operation em y

Cylinder driven by external pilot air Operation is foreign matter high reliability equipped by certain strongly.

With incorporated solenoid valve available by valve for steam Air operated type and solenoid valve integrated type are newly added in the series. This CKD original solenoid valve integrated type is realized with advanced technologies including new heat resistance and insulation materials.

Usable in flammable environment Due to air operated perfect structure, SAB can be used in the flammable environment.

Stable operation, durable to foreign matters and compatible with different fluids water, air, gas, low vacuum,

SAB/SVB series variation Model

Applicable fluids

SAB/SVB*W

Water and liquid

SAB/SVB*A

Air/gas

SAB/SVB*V

Low vacuum

SAB/SVB*S

For steam steam to high viscosity fluid or powder mixed fluids, etc., and compatible with wide applications. 2 port valve

Air operated 2 port valve

50%

Power consumption is reduced to 2W form conventional 4W (DC).

Ch

Usable from

50% downsized 40% cut

Port size 8A

10A

15A

20A

25A

32A/F

40A/F

50A/F

65F

80F

Page 3

Category

Air operated type

Model name

Water, liquid

Low vacuum

Steam, water, air

SVB*W Air/gas SVB*A Low vacuum SVB*V Steam, water, air SVB*S

NO

Double acting operation

Page Rc1/4

Rc3/8

Rc1/2

Rc3/4

Rc1

Rc1 1/4

32 Flange

Rc1 1/2

40 Flange

Rc2

50 Flange

65 Flange

80 Flange

9

SAB*V

13 2 port

Water, liquid

NC

5

SAB*A

SAB*S

Port size

Actuation

1

Air/gas

Intro 1

Series variation

(Cylinder valve)

SAB*W

With solenoid valve

SAB/SVB Series

Air operated 2 port valve

No. of port

Series variation

17

25

29

33

Intro 2

Page 4

Flow characteristics 1. Flow characteristics indication The catalog specifications indicate the flow as followings. Components

Indication

Unit

New JIS compliant indication

C and b

Pneumatic components

S

Conventional indication

Cv General purpose valves

New JIS compliant indication Cv Conventional indication

Standards ISO 6358: 1989 Pneumatic fluid power - Components using compressible fluids - Determination of flow-rate characteristics JIS B8390: 2000 (ISO 6358 translation) JIS B8373: 1993 " pneumatic 2 port solenoid valve " JIS B8374: 1993 " pneumatic 3 port solenoid valve " JIS B8375: 1993 " pneumatic 4/5 port solenoid valve " JIS B8379: 1995 " pneumatics noise reduction device " ANSI (NFPA) T3.21.3: 1990 IEC 60534-2-3: 1997 Industrial-process control valves - Part 2-3: Flow capacity - Test procedures JIS B2005-2-3: 2004 (IEC 60534-2-3 translation) JIS B8471: 2004 " solenoid valve for water " JIS B8472: 1994 " solenoid valve for steam " JIS B8473: 1994 " solenoid valve for fuel "

2. Explanation of pneumatic components The flow characteristics of pneumatic components were conventionally indicated with effective sectional area S and capacity coefficient Cv. JIS was revised (JIS B 8390: 2000), and these are now indicated with sonic conductance C and critical pressure ratio b.

component in the choke flow by the sum of the upstream absolute pressure and standard state density. (sonic conductance) S

5.0C (C can be sized in the conventional method.)

Critical pressure ratio b: Pressure rate at which choke flow results if smaller than this value.

Mass flow

The sonic conductance C: Value obtained by dividing the passage mass flow of the

(downstream pressure/upstream pressure) (critical pressure ratio)

Effective sectional area S (mm2): Value calculated from changes in pneumatic tank pressure

Critical pressure ratio b indicating the ideal restriction effective sectional area at which friction or restricted flow does not occur when flowing in the choke flow from the component on the pneumatic tank. * Choke flow: Flow at which upstream pressure is higher than downstream pressure, and speed at

Subsonic flow Chalk flow certain sections of components reaches sonic levels. The fluid's mass flow is proportional to the upstream pressure, and does not rely on downstream pressure. (Choked flow)

Drawing 1 Mass flow characteristics for primary side pressure.

Flow formula Shown as followings depending on the practical unit Q : Flow rate [dm3/min(ANR)], SI unit dm3 (cubic decimeter) is expressed as (liter). 1dm3 = 1 C : Sonic conductance (dm3/ (s/bar)) b : Critical pressure ratio (-) P1 : Primary side pressure (MPa) P2 : Secondary side pressure (MPa) t : Temperature ( )

P2 + 0.1 P1 + 0.1

Chalk flow when b

293

Q = 600 x C (P1 + 0.1)

: (1)

273 + t P2 + 0.1 P1 + 0.1

Subsonic flow when > b

2

P2 + 0.1 Q = 600 x C (P1 + 0.1)

1-

P1 + 0.1

-b

293

: : (2)

273 + t 1-b

To calculate effective sectional area S, substitute value C obtained with C=S/5 in the above formula. For subsonic flow, substitute b = 0.5 in formula (2).

Intro 3

Page 5

3. Explanation of general purpose valves The general purpose valve flow characters are indicated with capacity coefficient Cv. To comply with old IEC Standards, attempts were made to indicate features with capacity coefficient Av to unify indications with SI units. The Av value was eliminated from the control valve capacity coefficient with JIS B 2005-2-3: 2004 revisions, and only Kv and Cv types are used. The Cv indication is still used to indicate flow features of the general purpose valves. For Av values, conversion values are listed for reference as needed. Capacity

: The non-SI adjustment valve capacity coefficient is used commonly worldwide. U.S. gal value indicating the flow coefficient Cv of 40 to 100°F city water for one minute through the valve (test part) when the differential pressure is 1 psi.

1

Cv = Q

Capacity w

P

Cv : Capacity coefficient Q : Flow (U.S.gal/min) (1U.S.gal/min. = 6,309 x 10-5m3/s) : Fluid density (1b/ft3) (1b/ft3 = 16,018kg/m3) w : 40°F to 100°F (4 to 38 ) water density (1b/ft3) P : differential pressure (psi) (1psi = 6.8948kPa)

: (3)

: Value indicating city water flow rate passing through valve (test part) as m3/s unit at pressure difference 1 Pa.

coefficient Av The value is calculated based on the following formula.

Av = Q

P

Av : Capacity coefficient (m2) Q : Flow (m3/s) : Fluid density (kg/m3) P : Differential pressure (Pa)

: (4)

Flow formula Shown as followings depending on the practical unit

Capacity coefficient Cv For liquid:

Q = 45.16 Cv

P G

Cv : Flow factor Q : Flow ( /min) P : Differential pressure (MPa) G : Specific gravity (water G = 1)

: (5)

For steam: P1 For P2

2

97 Cv P1 W=

P1 For P2 >

2

K 194 Cv

W=

: (6)

(P1 -P2 ) P2 K

: (7)

Cv W P1 P2 K

: Flow factor : Flow (kg/h) : Primary absolute pressure (MPa) : Secondary absolute pressure (MPa) : (1 + 0.0013ts) ts: Degree of superheat (Saturated vapor K = 1)

Intro 4

Page 6

Flow formula Shown as followings depending on the practical unit

Capacity coefficient Av For liquid: Q = 1.9 x 106Av

P G

Q : Flow ( /min) Av : Capacity coefficient (m2) P: Differential pressure (MPa) G : Specific gravity (water = 1)

: (8)

For steam: Q = 8.1 x 106 Av

P (P2 + 0.1)

: (9)

Q : Flow (kg/h) Av : Capacity coefficient (m2) P: Differential pressure (MPa) P1 : Primary side pressure (MPa) : P = P1 - P2 P2 : Secondary side pressure (MPa)

Conversion of capacity coefficient Av = 28 x 10-6 Kv = 24 x 10-6 Cv : (10)

Kv : Value indicating the flow of 5 to 40 city water as m3/h passing through the valve when the differential pressure is 1 bar. Cv : Value indicating 60°F city water flow rate passing through valve as US gal/min unit at pressure difference 1lbf/in2 (psi). Values do not match because test methods for Kv and Cv for pneumatic use differ.

Intro 5

Page 7 read from a scan by OCR; it may hold reading errors

MEMO

CKD Intro 6

Page 8

Fluid control components

Safety precautions Always read this section before starting use.

When designing and manufacturing a device using CKD products, the manufacturer is obligated to check that device safety mechanical mechanism, pneumatic control circuit, or water control circuit and the system operated by electrical control that controls the devices is secured. It is important to select, use, handle, and maintain the product appropriately to ensure that the CKD product is used safely. Observe warnings and precautions to ensure device safety. Check that device safety is ensured, and manufacture a safe device.

WARNING 1 This product is designed and manufactured as a general industrial machine part. It must be handled by an operator having sufficient knowledge and experience in handling.

2 Use this product in accordance of specifications. Contact CKD when using the product outside the unique specifications range, when using it outdoors, and when using it under the conditions and environment below. Do not attempt to modify or additionally machine the product. 1 Use for special applications requiring safety including nuclear energy, railroad, aviation, ship, vehicle, medical equipment, equipment, or applications coming into contact with beverage or food, amusement equipment, emergency shutoff circuits, press machine, brake circuits, or for safeguard. 2 Use for applications where life or assets could be adversely affected, and special safety measures are required.

3 Observe corporate standards and regulations, etc., related to the safety of device design and control, etc. ISO4414, JIS B8370 (pneumatic system rules) Including High Pressure Gas Maintenance Law, Occupational Safety and Sanitation Laws, other safety rules, body standards and regulations, etc.

4 Do not handle, pipe, or remove devices before confirming safety. 1 Inspect and service the machine and devices after confirming safety of the entire system related to this product. 2 Note that there may be hot or charged sections even after operation is stopped. 3 When inspecting or servicing the device, turn off the energy source (air supply or water supply), and turn off power to the facility.

Discharge any compressed air from the system, and pay enough attention to possible water leakage and leakage of electricity. 4 When starting or restarting a machine or device that incorporates pneumatic components, make sure that the system safety, such as pop-out prevention measures, is secured.

5 Observe warnings and cautions on the pages below to prevent accidents. The safety cautions are ranked as "DANGER", "WARNING" and "CAUTION" in this section.

DANGER : When a dangerous situation may occur if handling is mistaken leading to fatal or serious injuries, or when there is a high degree of emergency to a warning. WARNING: When a dangerous situation may occur if handling is mistaken leading to fatal or serious injuries.

CAUTION : When a dangerous situation may occur if handling is mistaken leading to minor injuries or physical damage. Note that some items described as "CAUTION" may lead to serious results depending on the situation. In any case, important information that must be observed is explained.

Intro 7

Page 9

Safety precautions

Fluid control components warning and cautions Always read this section before starting use.

Design & Selection CAUTION

1. Safety designing

External pilot air

WARNING This product can not be used as an emergency shut off valve. Valves in this catalog are not designed to ensure safety such as emergency shutoff. When using in this system, take separate measures that will ensure safety.

Take measures to prevent harm to operators or objects if this product fails

CAUTION Leakage current from other fluid control components When operating the solenoid valve with a programmable controller, etc., check that leakage current from the programmable controller's output is within the specifications below. Failure to observe this could lead to malfunctions. CR circuit Triode AC Switch

C

Programmable controller side

R

Leakage Current

100 VAC: 3mA or less 200 VAC: 1.5mA or less 24 VDC: 1mA or less must be maintained.

(1) Drainage measures: Compressed air contains high levels of drainage (water, oxidized oil, tar, foreign matter) that may reduce pneumatic component reliability. Improve air quality by dehumidifying with an after cooler or dryer, removing foreign matter with a filter, and removing tar with a tar removal filter, etc. (2) Pre-lubrication: This series is used with pre-lubrication specifications, so a lubricator is not required. When lubricating, continuously lubricate so that the component does not run out of lubrication. Use the turbine oil Class 1/ ISOVG32 (#90) or equivalent. (3) Filter: Install a filter with a 5 m or less filter element.

3. Working environment WARNING SVB series can not be used in the flammable environment. When using in a flammable environment, change the model to the SAB Series and provide a separate explosion-proof solenoid valve in the pilot air circuit.

Solenoid valve

Do not use this product in an environment in which corrosive gases could impregnate configuration materials.

In fluid flow, if a liquid ring circuit is created, pressure could rise when temperature fluctuates and prevent operation. Provide a relief valve so that a liquid ring circuit is not created.

Do not use this product near heat-generating elements or where it may be subject to radiated heat.

Vibration

Use the product within the ambient temperature range.

Mount and use in a place with no vibration.

Take the appropriate freezing prevention such as the countermeasures for cold district use. When insulating the solenoid valve, etc., do not treat the coil.

Liquid ring

2. Working fluid WARNING Working fluid (1) Do not use this product for fluids other than applicable fluids in catalog specifications. (2) Before starting use, confirm compatibility of the product and applicable fluid with the Control Fluid Checklist (Introduction, page 14). (3) Depending on the model, wear powder could be generated when internal parts are worn through valve operation. This could flow to the secondary side of the valve. (4) The durability of the rod packing (MY packing) drops if working fluid quality is poor and contains powder, sludge, or foreign matter. If rod packing sealing is poor, working fluid could leak into the cylinder and flow back into pilot air piping, damaging to devices in the air circuit. Conduct regular maintenance or take appropriate measures.

Special purpose grease For cylinder valve, grease applies to the piston rod sealing sections. When using special fluids, indicate the type of grease. <Example> Oxygen: Fluorine grease Medium vacuum: Silicone grease Fluids for foods: Vaseline Dry air for painting: Vaseline

Fluid temperature

Take appropriate safeguards for protective structures listed in catalog specifications. Consult with CKD when using outdoors. Take appropriate safeguards when using this product in places where oil or spatter from welding, etc., contact could occur. If levels of dust are high in the area, provide a silencer on the exhaust port or face the elbow joint downward so that dust does not get inside. Take appropriate safeguards when using this product in places where water contact could occur.

4. How to use WARNING Do not touch coils or actuators with hands or otherwise while power is on or immediately after turning power on. The solenoid valve's coil and actuator will heat up when electricity is passed through them. Depending on the product, directly touching these sections could cause burns.

Use within the working fluid temperature range.

Intro 8

Page 10

SAB/SVB Series Do not touch electric wiring connections with hands or otherwise (bare charged sections) while power is on. An electric shock could occur. Touching electric wire connections while power is on could lead to electrical shock.

Use within the maximum service pressure and maximum working pressure difference range.

CAUTION Do not step the valve, nor put the heavy things on it. When using the product with continuous energizing and low frequency, consult with CKD. If the product has not been used for more than a month, carry out trial operation.

When not using the product for one or more months after using water or hot water, remove any water or hot water left in the product. Water or hot water residue will cause rusting and may lead to operation faults or leaks. If residual water cannot be removed, operate the valve several times a day to ensure correct use.

5. Securing of space CAUTION Secure sufficient space for maintenance and inspection.

Installation & Adjustment 1. Installation CAUTION Always thoroughly read the Instruction Manual before installing this product. Do not apply external force to the coil section when a solenoid valve is installed. After installing, check for leaks from pipes and for wire connections, and check that the product is correctly installed.

2. Piping CAUTION Observe the valid thread length for piping. Chamfer the end of the screw a half-pitch. Before piping, flush the inside of the pipe with 0.3 MPa of air, and remove foreign matter such as dirt, metal chips, rust, and sealing tape. If excessive sealant (tape, gel) is applied when piping, it could enter the product and cause operation faults. When applying or wrapping sealant on piping material, apply it or wind it from the pipe end along the screw and leave 1.5 to 2 threads uncovered. Dirt or foreign matter in fluid may prevent the product from functioning correctly. Install an 80 mesh or higher filter for water flow, and a 5 m or less filter for air flow. Do not mistake the supply port when piping to the product. Do not pipe with using a solenoid valve section. Failure to observe this, the product could be damaged. (For solenoid valve) Install the by-pass circuit, and use the elbow union when piping to simplify the maintenance or repair work.

When piping the SAB or SVB Series, pay attention to the supply port on the unit and pilot operation side. Model no. SAB1W SAB2W SAB3W SAB1A SAB2A SAB3A SAB1V SAB2V SAB3V SAB1S SAB2S SAB3S SVB1W SVB2W SVB1A SVB2A SVB1V SVB2V SVB1S SVB2S

Body side supply port

Pilot operation side supply port

A A A B A A or B A A A B A A or B A A B A A A B A

X Y X and Y X Y X and Y X Y X and Y X Y X and Y P P P P P P P P

1

Note 1) With the SAB 23 V or SVB 12 V side port, connect the chamber (vacuum holding side) to port A.

Vacuum pump Chamber

V.P A

B

Note that when using for vacuum break, etc., set the pressurized port to port A.

When operating a hydraulic cylinder with a cylinder valve for water, if the valve's B port is piped to the cylinder, pressure in the valve's B port and piping rises and apply excessive pressure on the valve body, leading to damage. In this case, pipe the valve's A port to the cylinder side. Example of improper use)

Example of proper use)

Sealed

A B

Sealed

B A

When controlling fluid in a tank, pipe at a level slightly above the bottom of the tank. A

Intro 9

B

B A