Page 1 of Air operated 2 port valve (cylinder valve) SAB/SVB Series

Spec sheet · CKD Pneumatic

Air operated 2 port valve (cylinder valve) SAB/SVB Series

Spec sheet58 pagesPDF 1.3 MB

CKD catalog for the SAB/SVB Series air operated 2 port valves (cylinder valves) for water, air, low vacuum and steam.

What this file really is

The old site listed this file as a spec sheet for the CKD Pneumatic CVS2-15A-05-02H-1. The file is named for the CKD CVS2-15A-05-02H-1, but it is a catalog for the SAB/SVB Series air operated 2 port valves; CVS2 appears only in an optional connector part number.

Download the PDF1.3 MB

Filed with · 1 model

Also filed with these models on the old site

Summary

What is in it

A CKD product catalog for the SAB and SVB Series air operated 2 port valves, also called cylinder valves. It explains the series variations by fluid (water and liquid, air and gas, low vacuum, steam), port sizes and actuation types, flow characteristic formulas, and detailed safety precautions for design, piping, wiring, pilot air pressure and maintenance, followed by the specification pages for each model group, including solenoid valve integrated versions.

From the sheet

Key facts from this sheet

Each line names its page in the PDF.

A CKD catalog (CC-770A) for the SAB and SVB Series air operated 2 port valves (cylinder valves), in NC, NO and double acting types for water, air or gas, low vacuum and steam. It does not describe the CVS2-15A-05-02H-1 itself; the CVS2 name appears only in the part number of an optional DIN terminal box connector. It gives specifications, model number codes, dimensions, parts lists and installation and maintenance cautions.

Read for this summary: pages 1 to 6, 8, 11 to 12, 16 to 20, 28 to 29 and 58 of 58.

Product
SAB/SVB Series air operated 2 port valve (cylinder valve), catalog CC-770A p. 1
Fluid variants
SAB/SVB*W water and liquid; *A air/gas; *V low vacuum; *S steam p. 2
Actuation
NC (normally closed), NO (normally open) or double acting p. 16
Port sizes
Rc1/4 to Rc2 and 32 to 80 flange; 65 and 80 flanges custom order; SAB*S up to 50 flange p. 16, 28
Materials
Bronze or stainless steel body; nitrile, fluoro, ethylene propylene diene rubber or tetrafluoroethylene resin seals p. 2
SAB*W-15A
Rc1/2 port, 15 mm orifice, Cv flow factor 5.6 p. 16
SAB*S steam rating
SAB*S: fluid temperature -10 to 184 (no freezing); ambient -10 to 90; pilot air 0.35 to 0.7 MPa p. 28
SAB*W fluid temperature
SAB*W: -10 to 60 (no freezing); fluoro rubber (FKM) sealant -10 to 90 p. 16
SAB*A seat leakage
SAB*A: 0.12 cm3/min or less (with pneumatics) p. 20
Pilot port
Rc1/8; recommended tightening torque 7 to 9 N m p. 11, 16
DIN connector option
CVS2-CONNECTOR-F4-202936 changes the DIN terminal box outlet screw from Pg9 to G1/2 p. 11
Coil power
Low wattage coil: 2W instead of the conventional 4W (DC) p. 2
NAB Series comparison
Up to 40% less operating air and 50% smaller actuator; body face to face dimensions compatible p. 2
Wiring
Wire of 0.5mm2 nominal section area and over p. 11

What this sheet walks you through

  • Choosing a valve series by working fluid p. 2, 3
  • Building an SAB*W model number p. 17
  • Building an SAB*S model number for steam p. 29
  • Piping tightening torques for body and pilot ports p. 11
  • Wiring the solenoid valve integrated type p. 11
  • Setting pilot air pressure for NO and double acting types p. 12
  • Maintenance, inspection and disassembly p. 12
  • Reading flow figures: C, b, S and Cv p. 4, 5
  • SAB*W parts list and dimensions p. 18, 19

Good to know

  • The NC type cylinder cover holds a spring that can pop out; do not remove its snap ring. p. 12
  • Exhaust from other valves on a manifold can briefly open an SAB valve; use pilot valves with a built-in check valve. p. 11
  • Setting pilot pressure below the graphed range on NO and double acting types can cause a sealing fault. p. 12
  • On steam, install a steam trap by inclining the piping and remove drainage. p. 11
  • The cylinder cannot be operated manually while pressurized. p. 11

Questions this sheet answers

Does this catalog describe the CVS2-15A-05-02H-1?

No. It covers the SAB/SVB Series; the CVS2 name appears only in the optional DIN terminal box connector, CVS2-CONNECTOR-F4-202936. p. 1, 11

What does the model number SAB1W-15A-BB mean?

An NC type water valve with an Rc1/2 port, bronze body, fluoro rubber sealant and a mounting plate. p. 17

What steam temperature can the SAB*S valve handle?

The SAB*S lists a fluid temperature of -10 to 184 (no freezing) for steam, water and air. p. 28

How often should an SAB or SVB valve be inspected?

Every six months, adjusted for how often the valve is used. p. 12

The whole text · 6 parts

Read the sheet here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20
  3. Pages 21 to 3021-30
  4. Pages 31 to 4031-40
  5. Pages 41 to 5041-50
  6. Pages 51 to 5851-58

The file

Revision and size

RevisionCC-770A
PublisherCKD
Pages58
PDF1.3 MB
TextText from the PDF itself; pages 7 and 57 are scans, read by OCR, which may hold reading errors.