Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a spec sheet · part 5 of 6

Air operated 2 port valve (cylinder valve) SAB/SVB Series, pages 41 to 50

Pages 41 to 50 of 58

The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the CKD Pneumatic CVS2-15A-05-02H-1

Page 41

SVB*A Series How to order

How to order With solenoid valve

SVB

1

A

15A

B

2G

S

AC100V

Working fluid (Air and gas) Model no.

Symbol A

A Actuation

B B Port size

C

Descriptions

Actuation 1

NC (normally closed) type

2

NO (normally open) type

Port size 8A

Rc1/4

10A

Rc3/8

15A

Rc1/2

20A

Rc3/4

25A

Rc1

32A

Rc1 1/4

32F

32 flange

40A

Rc1 1/2

40F

40 flange

50A

Rc2

50F

50 flange

65F

65 flange (custom order)

80F

80 flange (custom order)

Body/sealant combination

C Body/sealant combination

*1 0

Standard

Fluoro rubber

Bronze

Ethylene propylene diene rubber

E

Option

Bronze

P

R D Coil

2C

3T

E Other options

Ethylene propylene diene rubber

With DIN terminal box with indicator light (Pg9) T type terminal box (G1/2) With T type terminal box with indicator light (G1/2)

No option

S

With surge suppressor

B

Mounting plate

Assembly direction Blank

No option

X

Cylinder guard 90° rotation

Y

Cylinder guard 180° rotation

Z

Cylinder guard 270° rotation

R

<Example of model number>

Coil 180° reverse rotation <with solenoid valve> Mounting plate/coil 180° reverse rotation <with solenoid valve>

Refer to Page 20 for the layout drawing.

SVB1A-15A-B2GS-AC100V Model: SVB A Actuation : NC (normally closed) type B Port size : Rc1/2 C Body/sealant combination : Body-bronze and sealant-fluoro rubber D With coil : DIN terminal box (Pg9) E Other options : With surge suppressor F Assembly direction : No option G Voltage : 100 VAC 50/60Hz and 110 VAC 60Hz

Stainless steel

Other options Blank

F

Fluoro rubber

With DIN terminal box (Pg9)

3R

*1: Body/sealant combination symbol is O or B for port size *2 65F or 80F. Note that the body is made from cast iron. *3 *2: Mounting plate (B in E ) can be installed for port size 8A to 32A. *4 *3: Indicate SB in E if both surge suppressor and mounting *5 plate are selected. *4: A surge suppressor is attached for the lead wire coil, while F Assembly direction assembled in the terminal box for the coil with terminal box. *6 *5: Manual override (non-locking) specifications are provided as standard. *6: Optional assembly directions are available for 8A to 50F.

Nitrile rubber

Stainless steel

Standard Grommet lead wire Option

2H

E

Stainless steel

Coil 2G

Note on model no. selection

Sealant Nitrile rubber

B D

D

Body Bronze

G G Voltage

Voltage

AC100V

100 VAC 50/60Hz 110 VAC 60Hz

AC200V

200 VAC 50/60Hz 220 VAC 60Hz

DC24V

24 VDC

26

Page 42

SVB*A Series Internal structure and parts list SVB1A

1

2 R

3

4 9

5

10 6 7

No. 1 2 3 4 5 6 7

8

8 9 10

Material Parts name Pilot solenoid valve Cylinder guard ADC12 Aluminum alloy die-casting Spring SWP Piano wire Piston A2017 Aluminum Adaptor C3604 (SUS304) Brass (stainless steel) Piston rod SUS304 Stainless steel Main valving NBR (FKM and EPDM) Nitrile rubber (fluoro, ethylene propylene diene) element SUS304 Stainless steel Body CAC407 (SCS13) Bronze casting (stainless steel casting) O ring NBR (FKM and EPDM) Nitrile rubber (fluoro, ethylene propylene diene) MY packing seal NBR (FKM and EPDM) Nitrile rubber (fluoro, ethylene propylene diene)

*1: The value in parentheses is for an option. *2: For 65F and 80F, the body is made from FC250 (cast iron), while main valving element is made from FKM.

Dimensions SVB*A-8A to 50A-*2C (Rc screw-in type) N Grommet lead wire type

(300)

19.5

15.5

22

Manual override P R

Rc1/8 M5 depth 4.5

D

E

(Exhaust port)

C

2-G

B

A

F

*Drawing indicates no optional assembly direction.

Model no. SVB*A-8A

B

C

D

50

24

12

45.5

SVB*A-15A

71

28

14.5

SVB*A-20A

80

35

17.5

SVB*A-25A

90

43

SVB*A-32A

125

SVB*A-40A SVB*A-50A

SVB*A-10A

27

A

E

F

G Rc1/4

N 48.5

102.5

32

65.5

125

43

Rc1/2

49.5

75

137.5

43

Rc3/4

49.5

21

85.5

151.5

53

Rc1

53

55

27.5

113.5

186

63

Rc1 1/4

57.5

140

61

30.5

134.5

210

77

Rc1 1/2

64.5

160

76

38

168

251

95

Rc2

72.5

Rc3/8

Page 43

SVB*A Series Dimensions, optional dimensions

Dimensions SVB*A-32F to 80F-*2C (flange type) Grommet lead wire type N (300)

22

19.5

15.5 Manual override

P

R

Rc1/8

E

D

M5 depth 4.5 (Exhaust port)

80F

H

L

K

4- 19

K

L

M A

8-

19

*Drawing indicates no optional assembly direction.

Model no.

A

D

E

H

K

L

M

N

SVB*A-32F

170

113.5

226

135

36

100

12

57.5

SVB*A-40F

180

134.5

249.5

140

42

105

12

64.5

SVB*A-50F

180

168

291

155

54

120

14

72.5

SVB*A-65F

210

203

347.5

175

68

140

16

113

SVB*A-80F

240

218

367.5

185

82

150

16

123

Optional dimensions DIN terminal box, T type terminal box and mounting plate are same as SVB*W Series. Refer to Page 23 and 24.

28

Page 44

Air operated 2 port valve with solenoid valve (Cylinder valve)

SVB*V Series NC (normally closed), NO (normally open) types Port size: Rc 1/4 to Rc2, 32 to 50 flange Working fluid: Low vacuum

JIS symbol

Common specifications

NC (normally closed) type

Descriptions

P

Actuation

B

SVB1V

SVB2V

NC (normally closed) type

NO (normally open) type

Low vacuum (air, water) (*1)

Working fluid mm2/s

Fluid viscosity

A

500 or less

Working pressure range Pa (abs) 1.3 x 102 to 7 x 105. (Note that this differs with the type, so refer to the working pressure range in each model's specifications.) NO (normally open) type

Withstanding pressure (water) MPa

P

Fluid temperature

B

A

2.0 -10 to 60 (no freezing)

Ambient temperature

-10 to 60

Valve seat leakage Pa m3/s He

1.33 x 10-3 or less Free

Mounting attitude *1: Refer to working fluid check list on Intro 14.

Electric specifications Rated voltage Apparent power (VA) Power consumption (W)

100 VAC (50/60Hz)/110 VAC (60Hz), 200 VAC (50/60Hz)/220 VAC (60Hz), 24 VDC 3.6 (50Hz), 2.8 (60Hz)

At holding At starting

11 (50Hz), 9 (60Hz)

AC

1.9 (50Hz), 1.5 (60Hz)

DC

2.0

Heat proof class

B

Protective structure

Grommet lead wire

IPX2

(IEC standards 529)

With DIN terminal box (Pg9)

IPX5

T type terminal box (G1/2)

IPX5

Note 1: The allowable voltage range should be within

10% of rated voltage.

Individual specifications Orifice C (mm) [dm3/(s bar)]

S Working pressure range Pa (abs) Pilot air pressure (MPa) Pilot Weight (kg) (mm2) NC type NO type NC type NO type Port size NC type NO type

Descriptions Model no.

Port size

SVB*V-8A

Rc1/4

10

8.3

0.4

-

SVB*V-10A

Rc3/8

10

12

0.3

-

SVB*V-15A

Rc1/2

15

-

-

140

SVB*V-20A

Rc3/4

16

-

-

180

SVB*V-25A

Rc1

20

-

-

280

SVB*V-32A

Rc1 1/4

26

-

-

450

SVB*V-32F

32 flange

26

-

-

450

SVB*V-40A

Rc1 1/2

32

-

-

680 b

0.5 1.3 x 102 to 7 x 105 to 1 x 106

0.5 0.35 to 0.7

(*1)

0.8 1 1.3 Rc1/8

2

1.3 x 10

5

2

1.3 x 10

6

0.25 to 0.7

(*1)

2.5

2.4

5.5

5.4

3.6

3.4

SVB*V-40F

40 flange

32

-

-

680

6.7

6.5

SVB*V-50A

Rc2

42

-

-

1020

5.7

5.4

SVB*V-50F

50 flange

42

-

-

1020

9.6

9.3 to 5 x 10

*1: Refer to page 11 in the introduction for details on the pilot air pressure for NO type.

29

1.3 x 102 to 1 x 10

Page 45

SVB*V Series How to order

How to order With solenoid valve

SVB

1

V

15A

B

2G

S

AC100V

Working fluid (Low vacuum)

Symbol A

Model no.

A Actuation

B B Port size

C

Descriptions

Actuation 1

NC (normally closed) type

2

NO (normally open) type

Port size 8A

Rc1/4

10A

Rc3/8

15A

Rc1/2

20A

Rc3/4

25A

Rc1

32A

Rc1 1/4

32F

32 flange

40A

Rc1 1/2

40F

40 flange

50A

Rc2

50F

50 flange

Body/sealant combination

C Body/sealant combination

Body 0

Standard

P D E

Option

B

R D D Coil

2C

3T

Note on model no. selection *1: Mounting plate (B in E ) can be installed for port size 8A to 32A. *2: Indicate SB in E if both surge suppressor and mounting plate are selected. *3: A surge suppressor is attached for the lead wire coil, while assembled in the terminal box for the coil with terminal box. *4: Manual override (non-locking) specifications are provided as standard.

Assembly direction

Ethylene propylene diene rubber Nitrile rubber

Stainless steel

Fluoro rubber

Stainless steel

Ethylene propylene diene rubber

With DIN terminal box with indicator light (Pg9) T type terminal box (G1/2) With T type terminal box with indicator light (G1/2)

No option

S

With surge suppressor

B

Mounting plate

Assembly direction Blank

No option

X

Cylinder guard 90° rotation

Y

Cylinder guard 180° rotation

Z

Cylinder guard 270° rotation

R

<Example of model number>

Coil 180° reverse rotation <with solenoid valve> Mounting plate/coil 180° reverse rotation <with solenoid valve>

Refer to Page 20 for the layout drawing.

SVB1V-15A-B2GS-AC100V Model: SVB A Actuation : NC (normally closed) type B Port size : Rc1/2 C Body/sealant combination : Body-bronze and sealant-fluoro rubber D Coil : With DIN terminal box (Pg9) E Other options : With surge suppressor F Assembly direction : No option G Voltage : 100 VAC 50/60Hz and 110 VAC 60Hz

Bronze Stainless steel

Other options Blank

F F

Fluoro rubber

With DIN terminal box (Pg9)

3R

*1 *2 *3 *4

Nitrile rubber

Bronze

Standard Grommet lead wire Option

2H

E

Bronze

Coil 2G

E Other options

Sealant

G G Voltage

Voltage

AC100V

100 VAC 50/60Hz 110 VAC 60Hz

AC200V

200 VAC 50/60Hz 220 VAC 60Hz

DC24V

24 VDC

30

Page 46

SVB*V Series Internal structure and parts list SVB1V

1

2 R

3

4 9

5

10 6 7 8

No. 1 2 3 4 5 6 7 8 9 10

Material Parts name Pilot solenoid valve Cylinder guard ADC12 Aluminum alloy die-casting Spring SWP Piano wire Piston A2017 Aluminum Adaptor C3604 (SUS304) Brass (stainless steel) Piston rod SUS304 Stainless steel Main valving NBR (FKM and EPDM) Nitrile rubber (fluoro, ethylene propylene diene) element SUS304 Stainless steel Body CAC407 (SCS13) Bronze casting (stainless steel casting) O ring NBR (FKM and EPDM) Nitrile rubber (fluoro, ethylene propylene diene) MY packing seal NBR (FKM and EPDM) Nitrile rubber (fluoro, ethylene propylene diene)

The value in parentheses is for an option.

Dimensions SVB*V-8A to 50A-*2C (Rc screw-in type) N Grommet lead wire type

(300)

19.5

15.5

22

Manual override P R

Rc1/8 M5 depth 4.5

D

E

(Exhaust port)

C

2-G

B

A

F

*Drawing indicates no optional assembly direction.

Model no. SVB*V-8A

B

C

D

50

24

12

45.5

SVB*V-15A

71

28

14.5

SVB*V-20A

80

35

17.5

SVB*V-25A

90

43

SVB*V-32A

125

SVB*V-40A SVB*V-50A

SVB*V-10A

31

A

E

F

G Rc1/4

N 48.5

102.5

32

65.5

125

43

Rc1/2

49.5

75

137.5

43

Rc3/4

49.5

21

85.5

151.5

53

Rc1

53

55

27.5

113.5

186

63

Rc1 1/4

57.5

140

61

30.5

134.5

210

77

Rc1 1/2

64.5

160

76

38

168

251

95

Rc2

72.5

Rc3/8

Page 47

SVB*VSeries Dimensions, optional dimensions

Dimensions SVB*V-32F to 50F-*2C (flange type) N Grommet lead wire type (300)

22

19.5

15.5 Manual override

P

R

Rc1/8

E

D

M5 depth 4.5 (Exhaust port)

H

L

K

4- 19

M A *Drawing indicates no optional assembly direction.

Model no.

A

D

E

H

K

L

M

N

SVB*V-32F

170

SVB*V-40F

180

113.5

226

135

36

100

12

57.5

134.5

249.5

140

42

105

12

SVB*V-50F

180

64.5

168

291

155

54

120

14

72.5

Optional dimensions DIN terminal box, T type terminal box and mounting plate are same as SVB*W Series. Refer to Page 23 and 24.

32

Page 48

Air operated 2 port valve with solenoid valve (Cylinder valve)

SVB*S Series NC (normally closed), NO (normally open) types Port size: Rc 1/4 to Rc2, 32 to 50 flange Working fluid: Steam, water, air

Common specifications

JIS symbol NC (normally closed) type

Descriptions

P

Actuation

B

SVB1S

SVB2S

NC (normally closed) type

NO (normally open) type

Steam, water, air, non-corrosive fluids (*1)

Working fluid mm2/S

Liquid viscosity

A

500 or less 0 to 1

Working pressure range MPa

NO (normally open) type P

Pilot air pressure B

2.0

Withstanding pressure (water) MPa MPa

0.35 to 0.7

A

Refer to Intro 11. -10 to 184 (no freezing)

Fluid temperature Ambient temperature

-10 to 60

Valve seat leakage cm3/min.

300 or less (with pneumatics 0.02 to 1MPa) Free

Mounting attitude *1: Refer to working fluid check list on Intro 14.

Electric specifications Rated voltage

100 VAC (50/60Hz)/110 VAC (60Hz), 200 VAC (50/60Hz)/220 VAC (60Hz), 24 VDC 3.6 (50Hz), 2.8 (60Hz)

At holding

Apparent power (VA) Power consumption (W)

At starting

11 (50Hz), 9 (60Hz)

AC

1.9 (50Hz), 1.5 (60Hz)

DC

2.0

Heat proof class

B

Protective structure

Grommet lead wire

IPX2

(IEC standards 529)

With DIN terminal box (Pg9)

IPX5

T type terminal box (G1/2)

IPX5

Note 1: The allowable voltage range should be within

10% of rated voltage.

Individual specifications Descriptions Model no.

Port size

Orifice (mm)

C [dm3/(s bar)] b

S (mm2)

Cv flow factor

Pilot port size

Weight (kg)

NC type: normally closed SVB1S-8A

Rc1/4

10

8.3

0.4

-

2.1

0.5

SVB1S-10A

Rc3/8

10

11

0.4

-

2.5

0.5

SVB1S-15A

Rc1/2

15

-

-

120

5.5

0.8

SVB1S-20A

Rc3/4

16

-

-

150

7

1

SVB1S-25A

Rc1

20

-

-

240

11

1.4

SVB1S-32A

Rc1 1/4

26

-

-

390

18.5

SVB1S-32F

32 flange

26

-

-

390

18.5

5.6

SVB1S-40A

Rc1 1/2

32

-

-

610

29

3.7

SVB1S-40F

40 flange

32

-

-

610

29

6.8

SVB1S-50A

Rc2

42

-

-

920

43

5.6

SVB1S-50F

50 flange

42

-

-

920

43

9.5

Rc1/8

2.6

NO type: normally open SVB2S-8A

Rc1/4

10

8.9

0.4

-

2.3

0.5

SVB2S-10A

Rc3/8

10

12

0.3

-

2.6

0.5

SVB2S-15A

Rc1/2

15

-

-

140

5.6

0.8

SVB2S-20A

Rc3/4

16

-

-

180

8

1

SVB2S-25A

Rc1

20

-

-

280

12

1.4

SVB2S-32A

Rc1 1/4

26

-

-

450

20

SVB2S-32F

32 flange

26

-

-

450

20

5.6

SVB2S-40A

Rc1 1/2

32

-

-

680

32

3.7

SVB2S-40F

40 flange

32

-

-

680

32

6.8

SVB2S-50A

Rc2

42

-

-

1020

50

5.6

SVB2S-50F

50 flange

42

-

-

1020

50

9.5

*1: Refer to page 11 in the introduction for details on the pilot air pressure for NO type.

33

Rc1/8

2.6

Page 49

SVB*S Series How to order

How to order With solenoid valve

SVB

1

S

15A

E

2G

L

AC100V

Working fluid (Steam, water, air) Symbol A

Model no.

A Actuation

B B Port size

C

Descriptions

Actuation 1

NC (normally closed) type

2

NO (normally open) type

Port size 8A

Rc1/4

10A

Rc3/8

15A

Rc1/2

20A

Rc3/4

25A

Rc1

32A

Rc1 1/4

32F

32 flange

40A

Rc1 1/2

40F

40 flange

50A

Rc2

50F

50 flange

Body/sealant combination

C Body/sealant combination

Body

*1

D D Coil

Stainless steel Tetrafluoroethylene resin Fluoro rubber water

F

Stainless steel Tetrafluoroethylene resin Tetrafluoroethylene resin Solvent

Coil Standard Grommet lead wire With DIN terminal box (Pg9)

3T

Option

2H

*4: Indicate as followings if options are selected E . Surge suppressor + mounting plate SB Surge suppressor + indicator SL Mounting plate + indicator BL Surge suppressor + mounting plate + indicator SBL *5: A surge suppressor is attached for the lead wire coil, while assembled in the terminal box for the coil with terminal box. *6: Manual override (non-locking) specifications are provided as standard.

F F

Assembly direction

No option

S

With surge suppressor

B

Mounting plate

L

With indicator

Assembly direction Blank

No option

X

Cylinder guard 90° rotation

Y

Cylinder guard 180° rotation

Z

Cylinder guard 270° rotation

R

Coil 180° reverse rotation <with solenoid valve> Mounting plate/coil 180° reverse rotation <with solenoid valve>

Refer to Page 20 for the layout drawing.

<Example of model number>

SVB1S-15A-E2GL-AC100V

T type terminal box (G1/2)

Other options Blank

*2 *3 *1: Select C or E for steam. *2: Mounting plate (B in E ) can be installed for port size 8A to *4 *5 32A. *3: Indicator (L in E ) is installed for only actuation 1: NC type. *6

With DIN terminal box with indicator light (Pg9) With T type terminal box with indicator light (G1/2)

3R E

Remarks

E

2C

E Other options

O ring

Bronze

2G

Note on model no. selection

Sealant

Tetrafluoroethylene resin Fluoro rubber Steam/air/

C

G G Voltage

Model: SVB A Actuation : NC (normally closed) type B Port size : Rc1/2 C Body/sealant combination : Body-stainless steel and sealant-tetrafluoroethylene resin D With coil : DIN terminal box (Pg9) E Other options : With indicator F Assembly direction : No option G Voltage : 100 VAC 50/60Hz and 110 VAC 60Hz

Voltage

AC100V

100 VAC 50/60Hz 110 VAC 60Hz

AC200V

200 VAC 50/60Hz 220 VAC 60Hz

DC24V

24 VDC

34

Page 50

SVB*S Series Internal structure and parts list SVB1S

1

2 R

3

4

5 9 6

7

8

No. 1 2 3 4 5 6 7 8 9

Parts name Pilot solenoid valve Cylinder guard Spring Piston Adaptor Piston rod Main valving element

Material

ADC12 SWP A2017 C3604 (SUS304) SUS304 PTFE CAC407 (SCS13) Body Rod packing seal PTFE

The value in parentheses is for an option.

35

Aluminum alloy die-casting Piano wire Aluminum Brass (stainless steel) Stainless steel Tetrafluoroethylene resin Bronze casting (stainless steel casting) Tetrafluoroethylene resin