The text of a spec sheet · part 5 of 6
Air operated 2 port valve (cylinder valve) SAB/SVB Series, pages 41 to 50
Pages 41 to 50 of 58
The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the CKD Pneumatic CVS2-15A-05-02H-1
Page 41
SVB*A Series How to order
How to order With solenoid valve
SVB
1
A
15A
B
2G
S
AC100V
Working fluid (Air and gas) Model no.
Symbol A
A Actuation
B B Port size
C
Descriptions
Actuation 1
NC (normally closed) type
2
NO (normally open) type
Port size 8A
Rc1/4
10A
Rc3/8
15A
Rc1/2
20A
Rc3/4
25A
Rc1
32A
Rc1 1/4
32F
32 flange
40A
Rc1 1/2
40F
40 flange
50A
Rc2
50F
50 flange
65F
65 flange (custom order)
80F
80 flange (custom order)
Body/sealant combination
C Body/sealant combination
*1 0
Standard
Fluoro rubber
Bronze
Ethylene propylene diene rubber
E
Option
Bronze
P
R D Coil
2C
3T
E Other options
Ethylene propylene diene rubber
With DIN terminal box with indicator light (Pg9) T type terminal box (G1/2) With T type terminal box with indicator light (G1/2)
No option
S
With surge suppressor
B
Mounting plate
Assembly direction Blank
No option
X
Cylinder guard 90° rotation
Y
Cylinder guard 180° rotation
Z
Cylinder guard 270° rotation
R
<Example of model number>
Coil 180° reverse rotation <with solenoid valve> Mounting plate/coil 180° reverse rotation <with solenoid valve>
Refer to Page 20 for the layout drawing.
SVB1A-15A-B2GS-AC100V Model: SVB A Actuation : NC (normally closed) type B Port size : Rc1/2 C Body/sealant combination : Body-bronze and sealant-fluoro rubber D With coil : DIN terminal box (Pg9) E Other options : With surge suppressor F Assembly direction : No option G Voltage : 100 VAC 50/60Hz and 110 VAC 60Hz
Stainless steel
Other options Blank
F
Fluoro rubber
With DIN terminal box (Pg9)
3R
*1: Body/sealant combination symbol is O or B for port size *2 65F or 80F. Note that the body is made from cast iron. *3 *2: Mounting plate (B in E ) can be installed for port size 8A to 32A. *4 *3: Indicate SB in E if both surge suppressor and mounting *5 plate are selected. *4: A surge suppressor is attached for the lead wire coil, while F Assembly direction assembled in the terminal box for the coil with terminal box. *6 *5: Manual override (non-locking) specifications are provided as standard. *6: Optional assembly directions are available for 8A to 50F.
Nitrile rubber
Stainless steel
Standard Grommet lead wire Option
2H
E
Stainless steel
Coil 2G
Note on model no. selection
Sealant Nitrile rubber
B D
D
Body Bronze
G G Voltage
Voltage
AC100V
100 VAC 50/60Hz 110 VAC 60Hz
AC200V
200 VAC 50/60Hz 220 VAC 60Hz
DC24V
24 VDC
26
Page 42
SVB*A Series Internal structure and parts list SVB1A
1
2 R
3
4 9
5
10 6 7
No. 1 2 3 4 5 6 7
8
8 9 10
Material Parts name Pilot solenoid valve Cylinder guard ADC12 Aluminum alloy die-casting Spring SWP Piano wire Piston A2017 Aluminum Adaptor C3604 (SUS304) Brass (stainless steel) Piston rod SUS304 Stainless steel Main valving NBR (FKM and EPDM) Nitrile rubber (fluoro, ethylene propylene diene) element SUS304 Stainless steel Body CAC407 (SCS13) Bronze casting (stainless steel casting) O ring NBR (FKM and EPDM) Nitrile rubber (fluoro, ethylene propylene diene) MY packing seal NBR (FKM and EPDM) Nitrile rubber (fluoro, ethylene propylene diene)
*1: The value in parentheses is for an option. *2: For 65F and 80F, the body is made from FC250 (cast iron), while main valving element is made from FKM.
Dimensions SVB*A-8A to 50A-*2C (Rc screw-in type) N Grommet lead wire type
(300)
19.5
15.5
22
Manual override P R
Rc1/8 M5 depth 4.5
D
E
(Exhaust port)
C
2-G
B
A
F
*Drawing indicates no optional assembly direction.
Model no. SVB*A-8A
B
C
D
50
24
12
45.5
SVB*A-15A
71
28
14.5
SVB*A-20A
80
35
17.5
SVB*A-25A
90
43
SVB*A-32A
125
SVB*A-40A SVB*A-50A
SVB*A-10A
27
A
E
F
G Rc1/4
N 48.5
102.5
32
65.5
125
43
Rc1/2
49.5
75
137.5
43
Rc3/4
49.5
21
85.5
151.5
53
Rc1
53
55
27.5
113.5
186
63
Rc1 1/4
57.5
140
61
30.5
134.5
210
77
Rc1 1/2
64.5
160
76
38
168
251
95
Rc2
72.5
Rc3/8
Page 43
SVB*A Series Dimensions, optional dimensions
Dimensions SVB*A-32F to 80F-*2C (flange type) Grommet lead wire type N (300)
22
19.5
15.5 Manual override
P
R
Rc1/8
E
D
M5 depth 4.5 (Exhaust port)
80F
H
L
K
4- 19
K
L
M A
8-
19
*Drawing indicates no optional assembly direction.
Model no.
A
D
E
H
K
L
M
N
SVB*A-32F
170
113.5
226
135
36
100
12
57.5
SVB*A-40F
180
134.5
249.5
140
42
105
12
64.5
SVB*A-50F
180
168
291
155
54
120
14
72.5
SVB*A-65F
210
203
347.5
175
68
140
16
113
SVB*A-80F
240
218
367.5
185
82
150
16
123
Optional dimensions DIN terminal box, T type terminal box and mounting plate are same as SVB*W Series. Refer to Page 23 and 24.
28
Page 44
Air operated 2 port valve with solenoid valve (Cylinder valve)
SVB*V Series NC (normally closed), NO (normally open) types Port size: Rc 1/4 to Rc2, 32 to 50 flange Working fluid: Low vacuum
JIS symbol
Common specifications
NC (normally closed) type
Descriptions
P
Actuation
B
SVB1V
SVB2V
NC (normally closed) type
NO (normally open) type
Low vacuum (air, water) (*1)
Working fluid mm2/s
Fluid viscosity
A
500 or less
Working pressure range Pa (abs) 1.3 x 102 to 7 x 105. (Note that this differs with the type, so refer to the working pressure range in each model's specifications.) NO (normally open) type
Withstanding pressure (water) MPa
P
Fluid temperature
B
A
2.0 -10 to 60 (no freezing)
Ambient temperature
-10 to 60
Valve seat leakage Pa m3/s He
1.33 x 10-3 or less Free
Mounting attitude *1: Refer to working fluid check list on Intro 14.
Electric specifications Rated voltage Apparent power (VA) Power consumption (W)
100 VAC (50/60Hz)/110 VAC (60Hz), 200 VAC (50/60Hz)/220 VAC (60Hz), 24 VDC 3.6 (50Hz), 2.8 (60Hz)
At holding At starting
11 (50Hz), 9 (60Hz)
AC
1.9 (50Hz), 1.5 (60Hz)
DC
2.0
Heat proof class
B
Protective structure
Grommet lead wire
IPX2
(IEC standards 529)
With DIN terminal box (Pg9)
IPX5
T type terminal box (G1/2)
IPX5
Note 1: The allowable voltage range should be within
10% of rated voltage.
Individual specifications Orifice C (mm) [dm3/(s bar)]
S Working pressure range Pa (abs) Pilot air pressure (MPa) Pilot Weight (kg) (mm2) NC type NO type NC type NO type Port size NC type NO type
Descriptions Model no.
Port size
SVB*V-8A
Rc1/4
10
8.3
0.4
-
SVB*V-10A
Rc3/8
10
12
0.3
-
SVB*V-15A
Rc1/2
15
-
-
140
SVB*V-20A
Rc3/4
16
-
-
180
SVB*V-25A
Rc1
20
-
-
280
SVB*V-32A
Rc1 1/4
26
-
-
450
SVB*V-32F
32 flange
26
-
-
450
SVB*V-40A
Rc1 1/2
32
-
-
680 b
0.5 1.3 x 102 to 7 x 105 to 1 x 106
0.5 0.35 to 0.7
(*1)
0.8 1 1.3 Rc1/8
2
1.3 x 10
5
2
1.3 x 10
6
0.25 to 0.7
(*1)
2.5
2.4
5.5
5.4
3.6
3.4
SVB*V-40F
40 flange
32
-
-
680
6.7
6.5
SVB*V-50A
Rc2
42
-
-
1020
5.7
5.4
SVB*V-50F
50 flange
42
-
-
1020
9.6
9.3 to 5 x 10
*1: Refer to page 11 in the introduction for details on the pilot air pressure for NO type.
29
1.3 x 102 to 1 x 10
Page 45
SVB*V Series How to order
How to order With solenoid valve
SVB
1
V
15A
B
2G
S
AC100V
Working fluid (Low vacuum)
Symbol A
Model no.
A Actuation
B B Port size
C
Descriptions
Actuation 1
NC (normally closed) type
2
NO (normally open) type
Port size 8A
Rc1/4
10A
Rc3/8
15A
Rc1/2
20A
Rc3/4
25A
Rc1
32A
Rc1 1/4
32F
32 flange
40A
Rc1 1/2
40F
40 flange
50A
Rc2
50F
50 flange
Body/sealant combination
C Body/sealant combination
Body 0
Standard
P D E
Option
B
R D D Coil
2C
3T
Note on model no. selection *1: Mounting plate (B in E ) can be installed for port size 8A to 32A. *2: Indicate SB in E if both surge suppressor and mounting plate are selected. *3: A surge suppressor is attached for the lead wire coil, while assembled in the terminal box for the coil with terminal box. *4: Manual override (non-locking) specifications are provided as standard.
Assembly direction
Ethylene propylene diene rubber Nitrile rubber
Stainless steel
Fluoro rubber
Stainless steel
Ethylene propylene diene rubber
With DIN terminal box with indicator light (Pg9) T type terminal box (G1/2) With T type terminal box with indicator light (G1/2)
No option
S
With surge suppressor
B
Mounting plate
Assembly direction Blank
No option
X
Cylinder guard 90° rotation
Y
Cylinder guard 180° rotation
Z
Cylinder guard 270° rotation
R
<Example of model number>
Coil 180° reverse rotation <with solenoid valve> Mounting plate/coil 180° reverse rotation <with solenoid valve>
Refer to Page 20 for the layout drawing.
SVB1V-15A-B2GS-AC100V Model: SVB A Actuation : NC (normally closed) type B Port size : Rc1/2 C Body/sealant combination : Body-bronze and sealant-fluoro rubber D Coil : With DIN terminal box (Pg9) E Other options : With surge suppressor F Assembly direction : No option G Voltage : 100 VAC 50/60Hz and 110 VAC 60Hz
Bronze Stainless steel
Other options Blank
F F
Fluoro rubber
With DIN terminal box (Pg9)
3R
*1 *2 *3 *4
Nitrile rubber
Bronze
Standard Grommet lead wire Option
2H
E
Bronze
Coil 2G
E Other options
Sealant
G G Voltage
Voltage
AC100V
100 VAC 50/60Hz 110 VAC 60Hz
AC200V
200 VAC 50/60Hz 220 VAC 60Hz
DC24V
24 VDC
30
Page 46
SVB*V Series Internal structure and parts list SVB1V
1
2 R
3
4 9
5
10 6 7 8
No. 1 2 3 4 5 6 7 8 9 10
Material Parts name Pilot solenoid valve Cylinder guard ADC12 Aluminum alloy die-casting Spring SWP Piano wire Piston A2017 Aluminum Adaptor C3604 (SUS304) Brass (stainless steel) Piston rod SUS304 Stainless steel Main valving NBR (FKM and EPDM) Nitrile rubber (fluoro, ethylene propylene diene) element SUS304 Stainless steel Body CAC407 (SCS13) Bronze casting (stainless steel casting) O ring NBR (FKM and EPDM) Nitrile rubber (fluoro, ethylene propylene diene) MY packing seal NBR (FKM and EPDM) Nitrile rubber (fluoro, ethylene propylene diene)
The value in parentheses is for an option.
Dimensions SVB*V-8A to 50A-*2C (Rc screw-in type) N Grommet lead wire type
(300)
19.5
15.5
22
Manual override P R
Rc1/8 M5 depth 4.5
D
E
(Exhaust port)
C
2-G
B
A
F
*Drawing indicates no optional assembly direction.
Model no. SVB*V-8A
B
C
D
50
24
12
45.5
SVB*V-15A
71
28
14.5
SVB*V-20A
80
35
17.5
SVB*V-25A
90
43
SVB*V-32A
125
SVB*V-40A SVB*V-50A
SVB*V-10A
31
A
E
F
G Rc1/4
N 48.5
102.5
32
65.5
125
43
Rc1/2
49.5
75
137.5
43
Rc3/4
49.5
21
85.5
151.5
53
Rc1
53
55
27.5
113.5
186
63
Rc1 1/4
57.5
140
61
30.5
134.5
210
77
Rc1 1/2
64.5
160
76
38
168
251
95
Rc2
72.5
Rc3/8
Page 47
SVB*VSeries Dimensions, optional dimensions
Dimensions SVB*V-32F to 50F-*2C (flange type) N Grommet lead wire type (300)
22
19.5
15.5 Manual override
P
R
Rc1/8
E
D
M5 depth 4.5 (Exhaust port)
H
L
K
4- 19
M A *Drawing indicates no optional assembly direction.
Model no.
A
D
E
H
K
L
M
N
SVB*V-32F
170
SVB*V-40F
180
113.5
226
135
36
100
12
57.5
134.5
249.5
140
42
105
12
SVB*V-50F
180
64.5
168
291
155
54
120
14
72.5
Optional dimensions DIN terminal box, T type terminal box and mounting plate are same as SVB*W Series. Refer to Page 23 and 24.
32
Page 48
Air operated 2 port valve with solenoid valve (Cylinder valve)
SVB*S Series NC (normally closed), NO (normally open) types Port size: Rc 1/4 to Rc2, 32 to 50 flange Working fluid: Steam, water, air
Common specifications
JIS symbol NC (normally closed) type
Descriptions
P
Actuation
B
SVB1S
SVB2S
NC (normally closed) type
NO (normally open) type
Steam, water, air, non-corrosive fluids (*1)
Working fluid mm2/S
Liquid viscosity
A
500 or less 0 to 1
Working pressure range MPa
NO (normally open) type P
Pilot air pressure B
2.0
Withstanding pressure (water) MPa MPa
0.35 to 0.7
A
Refer to Intro 11. -10 to 184 (no freezing)
Fluid temperature Ambient temperature
-10 to 60
Valve seat leakage cm3/min.
300 or less (with pneumatics 0.02 to 1MPa) Free
Mounting attitude *1: Refer to working fluid check list on Intro 14.
Electric specifications Rated voltage
100 VAC (50/60Hz)/110 VAC (60Hz), 200 VAC (50/60Hz)/220 VAC (60Hz), 24 VDC 3.6 (50Hz), 2.8 (60Hz)
At holding
Apparent power (VA) Power consumption (W)
At starting
11 (50Hz), 9 (60Hz)
AC
1.9 (50Hz), 1.5 (60Hz)
DC
2.0
Heat proof class
B
Protective structure
Grommet lead wire
IPX2
(IEC standards 529)
With DIN terminal box (Pg9)
IPX5
T type terminal box (G1/2)
IPX5
Note 1: The allowable voltage range should be within
10% of rated voltage.
Individual specifications Descriptions Model no.
Port size
Orifice (mm)
C [dm3/(s bar)] b
S (mm2)
Cv flow factor
Pilot port size
Weight (kg)
NC type: normally closed SVB1S-8A
Rc1/4
10
8.3
0.4
-
2.1
0.5
SVB1S-10A
Rc3/8
10
11
0.4
-
2.5
0.5
SVB1S-15A
Rc1/2
15
-
-
120
5.5
0.8
SVB1S-20A
Rc3/4
16
-
-
150
7
1
SVB1S-25A
Rc1
20
-
-
240
11
1.4
SVB1S-32A
Rc1 1/4
26
-
-
390
18.5
SVB1S-32F
32 flange
26
-
-
390
18.5
5.6
SVB1S-40A
Rc1 1/2
32
-
-
610
29
3.7
SVB1S-40F
40 flange
32
-
-
610
29
6.8
SVB1S-50A
Rc2
42
-
-
920
43
5.6
SVB1S-50F
50 flange
42
-
-
920
43
9.5
Rc1/8
2.6
NO type: normally open SVB2S-8A
Rc1/4
10
8.9
0.4
-
2.3
0.5
SVB2S-10A
Rc3/8
10
12
0.3
-
2.6
0.5
SVB2S-15A
Rc1/2
15
-
-
140
5.6
0.8
SVB2S-20A
Rc3/4
16
-
-
180
8
1
SVB2S-25A
Rc1
20
-
-
280
12
1.4
SVB2S-32A
Rc1 1/4
26
-
-
450
20
SVB2S-32F
32 flange
26
-
-
450
20
5.6
SVB2S-40A
Rc1 1/2
32
-
-
680
32
3.7
SVB2S-40F
40 flange
32
-
-
680
32
6.8
SVB2S-50A
Rc2
42
-
-
1020
50
5.6
SVB2S-50F
50 flange
42
-
-
1020
50
9.5
*1: Refer to page 11 in the introduction for details on the pilot air pressure for NO type.
33
Rc1/8
2.6
Page 49
SVB*S Series How to order
How to order With solenoid valve
SVB
1
S
15A
E
2G
L
AC100V
Working fluid (Steam, water, air) Symbol A
Model no.
A Actuation
B B Port size
C
Descriptions
Actuation 1
NC (normally closed) type
2
NO (normally open) type
Port size 8A
Rc1/4
10A
Rc3/8
15A
Rc1/2
20A
Rc3/4
25A
Rc1
32A
Rc1 1/4
32F
32 flange
40A
Rc1 1/2
40F
40 flange
50A
Rc2
50F
50 flange
Body/sealant combination
C Body/sealant combination
Body
*1
D D Coil
Stainless steel Tetrafluoroethylene resin Fluoro rubber water
F
Stainless steel Tetrafluoroethylene resin Tetrafluoroethylene resin Solvent
Coil Standard Grommet lead wire With DIN terminal box (Pg9)
3T
Option
2H
*4: Indicate as followings if options are selected E . Surge suppressor + mounting plate SB Surge suppressor + indicator SL Mounting plate + indicator BL Surge suppressor + mounting plate + indicator SBL *5: A surge suppressor is attached for the lead wire coil, while assembled in the terminal box for the coil with terminal box. *6: Manual override (non-locking) specifications are provided as standard.
F F
Assembly direction
No option
S
With surge suppressor
B
Mounting plate
L
With indicator
Assembly direction Blank
No option
X
Cylinder guard 90° rotation
Y
Cylinder guard 180° rotation
Z
Cylinder guard 270° rotation
R
Coil 180° reverse rotation <with solenoid valve> Mounting plate/coil 180° reverse rotation <with solenoid valve>
Refer to Page 20 for the layout drawing.
<Example of model number>
SVB1S-15A-E2GL-AC100V
T type terminal box (G1/2)
Other options Blank
*2 *3 *1: Select C or E for steam. *2: Mounting plate (B in E ) can be installed for port size 8A to *4 *5 32A. *3: Indicator (L in E ) is installed for only actuation 1: NC type. *6
With DIN terminal box with indicator light (Pg9) With T type terminal box with indicator light (G1/2)
3R E
Remarks
E
2C
E Other options
O ring
Bronze
2G
Note on model no. selection
Sealant
Tetrafluoroethylene resin Fluoro rubber Steam/air/
C
G G Voltage
Model: SVB A Actuation : NC (normally closed) type B Port size : Rc1/2 C Body/sealant combination : Body-stainless steel and sealant-tetrafluoroethylene resin D With coil : DIN terminal box (Pg9) E Other options : With indicator F Assembly direction : No option G Voltage : 100 VAC 50/60Hz and 110 VAC 60Hz
Voltage
AC100V
100 VAC 50/60Hz 110 VAC 60Hz
AC200V
200 VAC 50/60Hz 220 VAC 60Hz
DC24V
24 VDC
34
Page 50
SVB*S Series Internal structure and parts list SVB1S
1
2 R
3
4
5 9 6
7
8
No. 1 2 3 4 5 6 7 8 9
Parts name Pilot solenoid valve Cylinder guard Spring Piston Adaptor Piston rod Main valving element
Material
ADC12 SWP A2017 C3604 (SUS304) SUS304 PTFE CAC407 (SCS13) Body Rod packing seal PTFE
The value in parentheses is for an option.
35
Aluminum alloy die-casting Piano wire Aluminum Brass (stainless steel) Stainless steel Tetrafluoroethylene resin Bronze casting (stainless steel casting) Tetrafluoroethylene resin