The text of a spec sheet · part 6 of 6
Air operated 2 port valve (cylinder valve) SAB/SVB Series, pages 51 to 58
Pages 51 to 58 of 58
The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the CKD Pneumatic CVS2-15A-05-02H-1
Page 51
SVB*S Series Dimensions
Dimensions SVB*S-8A to 50A-*2C (Rc screw-in type) N Grommet lead wire type
(300)
22
19. 5 15. 5
Manual override
Rc1/ 8
D
E
M5 depth 4.5 (Exhaust port)
C
2-G
B F
A *Drawing indicates no optional assembly direction.
Model no. SVB*S-8A
A
B
C
D
50
24
12
56.5
SVB*S-15A
71
28
14.5
SVB*S-20A
80
35
17.5
SVB*S-25A
90
43
SVB*S-32A
125
SVB*S-40A SVB*S-50A
SVB*S-10A
E
F
G
N
Rc1/4
54.5
113.5
32
81.5
141
43
Rc1/2
55.5
91
153.5
43
Rc3/4
55.5
21
102
168
53
Rc1
59
55
27.5
128.5
201
63
Rc1 1/4
63.5
140
61
30.5
154.5
230
77
Rc1 1/2
70.5
160
76
38
188
271
95
Rc2
78.5
SVB*S-32F to 50F-*2C (flange type) N Grommet lead wire type
(300)
19.5
Rc3/8
15.5
22 Manual override R
M5 depth 4.5 (Exhaust port)
E
D
Rc1/8
H
L
K
4- 19 M A *Drawing indicates no optional assembly direction.
Model no.
A
D
E
H
K
L
M
N
SVB*S-32F
170
128.5
241
135
36
100
12
63.5
SVB*S-40F
180
154.5
269.5
140
42
105
12
70.5
SVB*S-50F
180
188
311
155
54
120
14
78.5
36
Page 52
SVB*S Series Optional dimensions With DIN terminal box (Pg9),
With T type terminal box (G1/2), with DIN terminal box with indicator light (Pg9)
with T type terminal box with indicator light (G1/2) SVB*S-*-* 3T 3R
53
15.5
(85.5)
44
(Outer diameter
36
16
26
18 44.5 (38)
P
Pg9 Applicable cable
24
15.5 (54.5)
35
22
P
G1/2 4.5 to
7)
Indicator A SVB1S-8A to 50 F -** L
Port A
8
2
20
W (valve open)
Mounting plate SVB*S-8A/10A-** B
R
25
2- 6
37
Model no.
W
SVB1S-8A
4
SVB1S-10A
4
SVB1S-15A
6.5
SVB1S-20A
6.5
SVB1S-25A
7
SVB1S-32A/F
8
SVB1S-40A/F
10.5
SVB1S-50A/F
13
50 62
46
SVB*S-*-* 2G 2H
Page 53
SVB*S Series Optional dimensions
Dimensions Mounting plate SVB*S-15A to 32A-** B / B-R / B-Y
P
9
P
Q 12 R
S
T *Drawing indicates B .
Mounting plate SVB*S-15A to 32A-** B-X / B-Z
9
P
Q 12 R
S
T
*Drawing indicates B-X .
Model no.
P
Q
R
S
T
SVB*S-15A
90
70
55
2.3
30
SVB*S-20A
90
70
65
2.3
30
SVB*S-25A
95
75
68.5
3.2
40
SVB*S-32A
105
85
86.5
3.2
45
38
Page 54
SAB/SVB Series Options for interchanging old/new models Old/new complete interchangeable mounting plate Available in perfect compatible installation plate for old (NAB/NSB) installation plate type.
Series: SAB*W/A/V/S Series SVB*W/A/V/S Series * Refer to How to Order explanations on pages 2, 6, 10, and 14 for details on models for which the mounting plate option is selectable.
How to order 1
SAB
A
B
15A
B2
R
E Assembly Air operated Working fluid C Body/sealant type material combination direction A Actuation D Other options B Port size
1
SVB
A
B
15A
2G
B2
D
R
Other options
B
Mounting plate
B2
Compatible mounting plate
200 VAC
G Voltage With solenoid Working fluid C Body/sealant E Other options valve material combination A Actuation B Port size D Coil F Assembly direction E
Other options
B
Mounting plate
B2
Compatible mounting plate
Comparison of new and old products (air operated type) Old type Symbol
New type
B
Direction
Symbol
Direction Compatible mounting plate reverse rotation
B
B2-R
A
B
Arrangement
A
Arrangement
Comparison of new and old products (with solenoid valve) Old type
New type
Symbol
B
Symbol
Direction
-
Direction Coil reverse,mounting plate reverse
B
A
B2-R B
Arrangement
A
Arrangement *Mounting plate is assembled in the 180° opposite side, if "B2-R " is selected in the assembly directions.
New type Symbol
B2-Y
Direction
Cylinder guard 180° rotation, mounting plate reverse
B
A
Or
Arrangement *Mounting plate is assembled in the 180° opposite side, if "B2-Y" is selected in an assembly direction. indicates pilot port IN.
39
Page 55
SAB/SVB Series Dimensions
Dimensions SAB*W/A/V Series SVB*W/A/V Series
P
9
P
Q
R
12
Port B
S
Port A
T *The drawing indicates example when solenoid valve is installed.
Model no.
P
Q
R
S
T
SAB/SVB*W/A/V-15A
90
70
43
2.3
30
SAB/SVB*W/A/V-20A
95
75
48
2.3
40
SAB/SVB*W/A/V-25A
105
85
53
3.2
45
SAB*S Series SVB*S Series
P
9
P
12 R
Q
S
Port B
Port A
T *The drawing indicates example when solenoid valve is installed.
Model no.
P
Q
R
S
T
SAB/SVB*S-15A
90
70
53
2.3
30
SAB/SVB*S-20A
95
75
58
2.3
40
SAB/SVB*S-25A
105
85
63
3.2
45
40
Page 56
SAB/SVB Series Old/new replacement option Old/new pilot port size conversion connector Conversion connectors are available to correspond with differences in the old and new pilot port sizes.
Series: SAB/SVB Series How to order CVSE2-P-CONNECTOR-D4-162163 Dimensions Rc1/4 R 1/8
18 27
Hexagon head 21
Note: With the double-acting type, air port spacing is too narrow for two to be installed.
Introducing custom order parts A solenoid valve for pilot is incorporated at the valve top section. Series: SVB*A/V/W Series Consult with CKD, your nearest sales office, for "How to order": model no.
Open and close detecting switch of valve mounted on the cylinder valve. 2 types are available in open and close signal detection switch, valve single/both sides installation.
Series: SAB*A/V/W Series SVB*A/V/W Series
Consult with CKD, your nearest sales office, for "How to order": model no.
41
Page 57
MEMO
CKD
42
Page 58
CKD(SHANGHAI) CORPORATION ●WUXI OFFICE ●NANJING OFFICE ●HANGZHOU OFFICE ●WUHAN OFFICE ●QINGDAO OFFICE
●SHENYANG OFFICE ●XIAN OFFICE ●CHONGQING OFFICE ●CHENGDU OFFICE ●GUANGZHOU OFFICE ●SHENZHEN OFFICE
●SUZHOU OFFICE ●BEJING OFFICE ●TIANJING OFFICE ●CHANG CHUN OFFICE ●DALIAN OFFICE
CKD KOREA CORPORATION CKD CORPORATION EUROPE BRANCH
●HWASEONG OFFICE
CKD UK OFFICE
CKD CANADA
CKD CORPORATION TAIWAN BRANCH
M-CKD PRECISION SDN.BHD. CKD BELGIUM OFFICE
●JOHOR BAHRU OFFICE ●MELAKA OFFICE ●PENANG OFFICE
CKD CO.,LTD.,o.s. CZECH OFFICE
CKD SINGAPORE PTE. LTD.
CKD USA CORPORATION ●CINCINNATI OFFICE ●SAN ANTONIO OFFICE ●SAN JOSE OFFICE
CKD THAI CORPORATION LTD. ●LAEMCHABANG OFFICE ●NAVANAKORN OFFICE ●RAYONG OFFICE ●LAMPHUN OFFICE ●KORAT OFFICE ●AMATANAKORN OFFICE
:Distributors
Website http://www.ckd.co.jp/ □ OVERSEAS DPT. SALES DIV. 2-250 Ouji Komaki, Aichi 485-8551, Japan □ PHONE +81-(0)568-74-1338 FAX +81-(0)568-77-3461 U.S.A
Thailand
China
CKD USA CORPORATION
CKD THAI CORPORATION LTD.
CKD (SHANGHAI) CORPORATION
● HEADQUARTERS 4080 Winnetka Avenue, Rolling Meadows, IL 60008 USA
● SALES HEADQUARTERS-BANGKOK OFFICE Suwan Tower, 14/1 Soi Saladaeng 1, North Sathorn Rd., Bangrak, Bangkok 10500 Thailand
● SALES HEADQUARTERS / SHANGHAI OFFICE Room 1903, 333 Jiujiang Road, Shanghai, 200001, China
PHONE +1-847-368-0539 FAX +1-847-788-0575
PHONE +66(0) 2-267-6300 FAX +66-(0)2-267-6305
EUROPE CKD EUROPE BRANCH De Fruittuinen 28 Hoofddorp 2132NZ The Netherlands
Korea
CKD SINGAPORE PTE LTD.
CKD KOREA CORPORATION
705 Sims Drive #03-01/02, Shun Li Industrial Complex, 387384 Singapore
PHONE +31(0) 23-5541490 FAX +31-(0)23-5541491
Malaysia
PHONE +65-6744-2623 FAX +65-6744-2486
M-CKD PRECISION SDN.BHD. ● HEADQUARTERS Lot No.6,Jalan Modal 23/2, Seksyen 23, Kawasan, MIEL, Fasa 8, 40300 Shah Alam,Selangor Darul Ehsan, Malaysia
PHONE +86(0) 21-63602277 FAX +86-(0)21-63511661
Singapore
Taiwan
Room No.1105, 11th FL, The Korea Teachers Pention B/L. 27-2, Yoido-Dong, Youngdeungpo-Gu, Seoul, 150-742, Korea PHONE +82(0)2-783-5201〜5203 FAX +82(0)2-783-5204
CKD CORPORATION TAIWAN BRANCH
PHONE +60(0)3-5541-1468 FAX +60(0) 3-5541-1533
Rm.1405, 14F, No.96, Sec.2, Chung Shan N.Rd., Taipei, Taiwan, R.O.C. PHONE +886(0) 2-2523-0374 FAX +886-(0)2-2523-5081
The goods and their replicas, or the technology and software in this catalog are subject to complementary export regulations by Foreign Exchange and Foreign Trade Law of Japan. If the goods and their replicas, or the technology and software in this catalog are to be exported, laws require the exporter to make sure they will never be used for the development or the manufacture of weapons for mass destruction. ●Specifications are subject to change without notice.
2007.5.ACC