The text of a spec sheet · part 2 of 6
Air operated 2 port valve (cylinder valve) SAB/SVB Series, pages 11 to 20
Pages 11 to 20 of 58
The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the CKD Pneumatic CVS2-15A-05-02H-1
Page 11
SAB/SVB Series When using the valve for steam, external leaks could occur depending on fluid properties. Install a steam trap by inclining piping, etc., and remove drainage to prevent the inside of the pipe from rusting. Strainer
3. Wiring CAUTION Use the product within the allowable voltage range. Use outside of the allowable voltage range may lead to operation faults or coil damage.
SAB
Steam trap
Use a breaker such as the fuse, etc., on the control circuit for maintenance of electric equipment.
Refer to the table below for tightening torque when piping. <Product/body section piping>
Nominal piping diameter
Recommended piping tightening torque (N m)
Rc1/4 Rc3/8 Rc1/2 Rc3/4 Rc1 Rc1 1/4 Rc1 1/2 Rc2
23 to 25 31 to 33 41 to 43 62 to 65 83 to 86 97 to 100 104 to 108 132 to 136
If the electrical circuit is susceptible to solenoid surge, use a solenoid with a surge suppressor (option), or insert a surge absorber, etc., parallel to the solenoid. Use a wire with nominal section area 0.5mm2 and over as the reference. Check that no excessive force is applied to leads. When using an explosion-proof solenoid valve, follow explosion-proof policy when wiring.
Refer to the table below for tightening torque of the pilot air when piping.
Use of a switching circuit that does not cause contact chatter will lengthen the life of the solenoid valve and motorized valve.
Nominal piping diameter Recommended piping tightening torque (N m)
Wiring when solenoid valve is installed.
Rc1/8
7 to 9
If a manifold is used on the SAB Series operation valve, exhaust pressure from other valves could be led in and cause malfunctions such as momentary opening of the SAB. When using a manifold, use a valve with a built-in "check valve". Similar problems could occur if exhaust is led in from the SVB Series exhaust (R) port, so when piping the exhaust (R) port, do not connect with other exhaust circuits. A check valve is built into CKD pilot 3 or 5 port valve 4G Series. Example of pneumatic pressure that could misoperate
Exhaust pressure
Exhaust pressure
Misoperation of air-operated 2-port valve
(1) Refer to connections on page 13 in the introduction when wiring to a DIN terminal box or T-type terminal box. (2) The size of the screw for the DIN terminal box's junction box outlets can be changed from Pg9 to G1/2 using the optional connector below. 25 16
Pg9
Hexagon head 24
G1/2
Model no.: CVS2-CONNECTOR-F4-202936
(3) Coil orientation is changed by 180°. Turn the coil only when reversing the electric wire connection method. Do not lose internal parts when removing the coil.
Exhaust pressure
Pneumatics system using 4G series Miss-operation prevented for air operated 2 port valve
Check valve
Exhaust pressure
Exhaust pressure
*Note that cylinder can not be operated manually with pressurized state.
Intro 10
Page 12
SAB/SVB Series During Use & Maintenance 1. Maintenance & Inspection WARNING
WARNING
To ensure that the product is used optimally, regularly inspect the product every six months. This frequency varies with the frequency of use.
CAUTION Read the instruction manual thoroughly before starting maintenance to ensure correct operation. Turn power off and release fluids or pressure before starting maintenance. Care must be taken not to clog the strainer-filter. Pilot air pressure Use pilot air pressure in accordance with specifications. Set the pilot pressure for the SAB and SVB Series NO type and double-acting type as shown in the graph below. A sealing fault could occur if pressure is set less than the range shown in the graph below. The NC model type should be selected when the pilot air cannot be controlled. W
W
SAB 23 AV /SVB2 AV Series Pilot air pressure
0.7 0.6
(MPa)
0.1
Pilot air
0.5 set pressure range
0.4 0.3 0.2 0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Working pressure (MPa)
SAB23 S/SVB2S Series Pilot air pressure
0.7 0.6
(MPa)
0.1
0.5 0.4 0.3 range ssure et pre s ir a t Pilo
0.2 0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Working pressure (MPa)
Intro 11
2. Assembling & Disassembling A spring is used in the cylinder cover. When disassembling this type, the spring could pop out and cause injuries, so take care. The NC (normally closed) has a snap ring to prevent the spring from popping out. Do not remove the snap ring.
CAUTION When cleaning the product, use a low-polluting cleaning agent such as a neutral detergent. (Note that rubber parts must be replaced if they expand.) Consult with CKD on questions about consumables, etc.
Page 13
SAB/SVB Series CAUTION Assembling pilot solenoid valve (for solenoid valve) If the pilot solenoid valve has been disassembled, assemble it as follows.
(1) Coil side Disassembling Loosen the cross headed pan head machine screw, and lift up the coil assembly. The outer spring, plunger assembly, and O ring are removed. Reassembling Set parts in the sequence of the O ring, plunger assembly, outer spring, and coil assembly. Tighten cross headed pan head machine screw with 0.7 to 1.1N m. (2) Guard side Disassembling Loosen the cross headed pan head machine screw, and remove the cover. The valve element spring, valve element guide assembly, and O ring are removed. Reassembling Set parts in the sequence of the O ring, valve element guide assembly, valve element spring, and cover. Tighten cross headed pan head machine screw with 0.7 to 1.1 N m.
Cross headed pan head machine screw
Coil assembly Note 2
Outer spring
Plunger assembly
O ring
Body assembly
Note 1: Do not lose the components such as springs during disassembly. O ring
Note 2: The coil assembly direction is changed 180゚. Loosen and change the cross-headed pan head machine screw. Valving element guide assembly
Note 3: Turbine oil is applied to the plunger as a lubricant.
Valving element spring
Guard
SVB*W/SVB*A/SVB*V Pilot solenoid valve (actuator assembly kit) model no. *1 CVSE2-ACTUATOR-0 - Rated voltage
Cross headed flat head screw
Indicate the coil option symbol in field *1.
Pilot solenoid valve (actuator assembly kit) model no. for SVB*S *1 SVB-ACTUATOR-C - Rated voltage Indicate the coil option symbol in field *1.
Gasket direction (for solenoid valve) A gasket has principles. Check the principles to assemble if disassembling was made.
Gasket
Port R
Port R
SVB1*
SVB2*
NC (normally closed) type
NO (normally open) type
Intro 12
Page 14
SAB/SVB Series How to wire terminal box DIN terminal box (Pg9) and DIN terminal box (Pg9) with indicator light (1) Use the following cabtire cable. • Code outer diameter: 4.5 to 7, nominal section area: 0.75mm2 (2) Insert the crimp terminal for copper wires into the cabtire cable's lead wire, and crimp the terminal with the designated tool. M3 terminal screws are used with the terminal box. (3) Tighten screws with the following tightening torque. • Setscrew tightening torque: 0.5 N•m • Terminal screw tightening torque: 0.5 N•m Setscrew
6 Attach the case.
Tighten with the screws.
Case Note: 180° rotation permissible
T terminal box (G1/2), T types terminal box with indicator light (G1/2) (1) Use the following cabtire cable. • Nominal section area: 0.75mm2 (2) Insert the crimp terminal for copper wires into the cabtire cable's lead wire, and crimp the terminal with the designated tool. M3 terminal screws are used with the terminal box. (3) Tighten screws with the following tightening torque. • Set screw tightening torque: 0.5 N•m • Terminal screw tightening torque: 0.5 N•m
Gasket
Cap assembly
Washer
Gasket
Free terminal screw * Bare crimp terminal for copper wire JIS C2805 R1.25-3 Fixing bracket Coil lead wire
Cap 2 Set the cap, washer, gasket and case. 7 Fix the cable with the cap. 3 Terminal caulking bare crimp terminal for copper wire
Lock nut Set screw
Terminal box
4 Gland
Voltage terminal Note: distinction not required
Crimp terminal fixing Gland Gasket Ground terminal Coil assembly
* Cable connector
Ground cable Cabtire cord JIS C3306 VCTF 0.75mm2 Outer diameter 4.5 to 7
*600V vinyl insulation vinyl cabtire cable JIS C 3312 VCT 0.75mm2
1 Lead wire sheath pealing
5 Gasket and gland coil terminal insertion
Parts marked with an asterisk (*) are not included.
Make wiring by 1 to 7 work procedures.
* The orientation of the cable lead out port is changed by removing the terminal box from the case, rotating it by 180°, then replacing the terminal box into the case.
*Changing direction of T type terminal box Change the orientation of the T-type terminal block from the default state as follows. (1) Hold the width across flats (25 width) of the T-type terminal box with a tool (monkey wrench, spanner, etc.), and loosen it by turning counterclockwise. (2) Loosen the lock nut. (3) Rotate the T-type terminal box clockwise to 15° before the required position. (4) Tighten the lock nut to the coil by hand until it is moderately tight. (5) Hold the width across flats of the T-type terminal box with a tool, and rotate it (approx. 15°) to tighten it to the required position. Note: When further tightening the terminal box to change the orientation from the default, rotate it within 1/2-turn.
Intro 13
Page 15
SAB/SVB Series Working fluid check list : Available : Limited, x: Not available : No applications *1: As a limitation, use is possible if conditions given in ( ) after the fluid name are met.
PTFE
EPDM
FKM
NBR
Stainless steel
PTFE
EPDM
Sealant
Fluid name
FKM
Bronze
Body material
NBR
Material combination a Acetylene Linseed oil Argon d Ethylene glycol The AE agent e Ozone (concentration must be low. A few ppm or less) f Gasoline (must be pure gasoline.) h Glycerin Cresol i Light oil Sodium silicate aqueous solution l Heavy oil A (FKM recommended if additive is entered.) Heavy oil B Heavy oil C Deionized water Silicone oil m Sodium hydroxide Hydrogen gas (High temperature not available. Use the air-operated type when explosion-proof measures are required.) n Liquid soap p Carbon oxide Carbonated water q Nitrogen gas s Natural gas t Kerosene P Propane gas Options per series option : Standard products : Option available
SAB1/2/3, SVB1/2 SAB1S/2S/3S, SVB1S/2S
CAUTION This checklist was prepared using CKD results. These values are for reference only, and are not guaranteed under all conditions. Test and confirm adequacy before starting use.
Intro 14
Page 16
Air operated 2 port valve (Cylinder valve)
SAB*W Series NC (normally closed) type, NO (normally open) type, double acting type Port size: Rc1/4 to Rc2, 32 to 80 flange Working fluid: Water or non-corrosive liquid
JIS symbol
Common specifications
NC (normally closed) type B
Descriptions
SAB1W
X
500 or less mm2/s
Fluid viscosity
0 to 0.7 (*2)
Working pressure range MPa NO (normally open) type Y A
0 to 1 2.0
Withstanding pressure (water) MPa
-10 to 60 (no freezing) (*3)
Fluid temperature
B
Ambient temperature
-10 to 60
Valve seat leakage cm3/min
0 (with water pressure) Free
Mounting attitude Water hammer
Double acting type
1 or less (caused by water supply law)
MPa
*1: Refer to working fluid check list on Intro 14. *2: Note that this differs with the type, so refer to the working pressure range in each model's specifications. *3: Sealant fluoro rubber (FKM) is for -10 to 90 .
B X
Double acting type
Water, non-corrosive fluid (*1)
Working fluid A
SAB3W
SAB2W
NC (normally closed) type NO (normally open) type
Actuation
Y A
Individual specifications Orifice (mm)
Cv flow factor
Rc1/4
10
2.3
Rc3/8
10
2.6
SAB*W-15A
Rc1/2
15
5.6
SAB*W-20A
Rc3/4
16
8
SAB*W-25A
Rc1
20
12
SAB*W-32A
Rc1 1/4
26
20
SAB*W-32F
32 flange
26
SAB*W-40A
Rc1 1/2
SAB*W-40F SAB*W-50A
Descriptions Model no.
Port size
SAB*W-8A SAB*W-10A
Working pressure range (MPa) Pilot air pressure (MPa) Pilot Weight (kg) NC type NO type Double act NC type NO type Double act Port size NC type NO type Double act 0.3 0.3 0 to 0.7
0 to 1
0.35 to 0.7
0.6 0.8 1.1 Rc1/8
2.3
2.2
2.2
20
5.3
5.2
5.2
32
32
3.4
3.2
3.2
40 flange
32
32
6.5
6.3
6.3
Rc2
42
50
5.5
5.2
5
SAB*W-50F
50 flange
42
50
9.4
9.1
8.9
SAB*W-65F (*2)
65 flange
65
70
20.5
19
18
SAB*W-80F (*2)
80 flange
79
100
25
23
22
0 to 0.5
0 to 1
0.25 to 0.7
*1: Refer to page 11 in the introduction for details on the pilot air pressure for NO and double-acting types. *2: Port size 65 and 80 flanges are custom order.
1
(*1)
(*1)
Page 17
SAB*W Series How to order
How to order SAB
1
W
B
15A
B
C Body/sealant material combination Working fluid
*1
D Other options
*2
(Water, liquid) Model no.
E Assembly direction
*3
Symbol
Descriptions
Actuation
A
A Actuation
1
NC (normally closed) type
2
NO (normally open) type
3
Double acting type
Port size
B B Port size
8A
Rc1/4
10A
Rc3/8
15A
Rc1/2
20A
Rc3/4
25A
Rc1
32A
Rc1 1/4
32F
32 flange
40A
Rc1 1/2
40F
40 flange
50A
Rc2
50F
50 flange
65F
65 flange (custom order)
80F
80 flange (custom order)
Body/sealant combination
C
Note on model no. selection 0 *1: Body/sealant combination symbol is O or B for port size 65F or 80F. Note that the body is made from cast iron. *2: Mounting plate (B in D ) can be installed for port size 8A to 32A. *3: Mounting plate assembly position reverse rotation (B-R in D ) is for port size 15A to 32A. *4: Clockwise viewed from above with port A facing right.
Standard
P D E
Option
B
R
<Example of model number>
D
Model: SAB A Actuation : NC (normally closed) type B Port size : Rc1/2 C Body/sealant combination : Body-bronze and sealant-fluoro rubber D Other options : Mounting plate E Assembly direction : No option
B E
Sealant Nitrile rubber
Bronze
Fluoro rubber
Bronze
Ethylene propylene diene rubber
Stainless steel
Nitrile rubber
Stainless steel
Fluoro rubber
Stainless steel
Ethylene propylene diene rubber
Other options Blank
SAB1W-15A-BB
Body Bronze
No option Mounting plate
Assembly direction Blank R
No option Mounting plate assembly position reverse rotation
Refer to the following diagram for the layout drawing. E Assembly direction
SAB (air operated type) *2/4 Symbol
B (mounting plate)
B-R *3
Direction
Without rotation
Mounting plate reverse rotation
B
A
B
A
Arrangement indicates pilot port IN.
2
Page 18
SAB*W Series Internal structure and parts list SAB1W 1
2
7
3
8
4
9
5
6
No. 1 2
Parts name Cylinder guard Piston
Material ADC12 A2017
Aluminum alloy die-casting
3
Adaptor
C3604 (SUS304)
Brass (stainless steel)
4
Piston rod Main valving
SUS304 Stainless steel NBR (FKM and EPDM) Nitrile rubber (fluoro, ethylene propylene diene) SUS304 Stainless steel CAC407 (SCS13) Bronze casting (stainless steel casting)
5 element
6 7
Body Spring
8
O ring
9
Aluminum
SWP
Piano wire
NBR (FKM and EPDM) Nitrile rubber (fluoro, ethylene propylene diene) MY packing seal NBR (FKM and EPDM) Nitrile rubber (fluoro, ethylene propylene diene)
*1: The value in parentheses is for an option. *2: For 65F and 80F, the body is made from FC250 (cast iron), while main valving element is made from FKM.
Dimensions SAB*W-8A to 50A (Rc screw-in type)
14.6
N
2-Rc1/8
10
Y
C
D
2-G
E
X
A
B F
Model no. SAB*W-8A
B
C
D
50
24
12
41.5
SAB*W-15A
71
28
14.5
SAB*W-20A
80
35
17.5
SAB*W-25A
90
43
SAB*W-32A
125
SAB*W-40A
140
SAB*W-50A
160
SAB*W-10A
3
A
E
F
G Rc1/4
N 37
71.5
32
61.5
94
43
Rc1/2
71
106.5
43
Rc3/4
38
21
81.5
120.5
53
Rc1
41.5
55
27.5
109.5
155
63
Rc1 1/4
46
61
30.5
130.5
179
77
Rc1 1/2
53
76
38
164
220
95
Rc2
61
Rc3/8
38
Page 19
SAB*W Series Dimensions, optional dimensions
Dimensions SAB*W-32F to 80F (flange type) 14.6
N
10
2-Rc1/8
Y
E
D
X
80F H
L
K
4-
19 K
L
M A
8- 19
Model no.
A
D
E
H
K
L
M
N
SAB*W-32F
170
109.5
195
135
36
100
12
46
SAB*W-40F
180
130.5
218.5
140
42
105
12
53
SAB*W-50F
180
164
259.5
155
54
120
14
61
SAB*W-65F
210
199
347.5
175
68
140
16
101
SAB*W-80F
240
214
367.5
185
82
150
16
111
Optional dimensions Mounting plate SAB*W-8A/10A-* B
Mounting plate SAB*W-15A to 32A-* B / B-R
X
9
P
8
2
20
Y
Port A
Q
6 25
2-
R
12 S
T *Drawing indicates B .
Model no.
P
Q
50
SAB*W-15A
90
62
SAB*W-20A
90
SAB*W-25A SAB*W-32A
*Use the body installation setscrews if fixed without mounting plate. (Thread size: M4 depth 8 pitch 19)
R
S
T
70
39
2.3
30
70
48.5
2.3
30
95
75
52
3.2
40
105
85
66.5
3.2
45
4
Page 20
Air operated 2 port valve (Cylinder valve)
SAB*A Series NC (normally closed) type, NO (normally open) type, double acting type Port size: Rc1/4 to Rc2, 32 to 80 flange Working fluid: Air, gas
JIS symbol
Common specifications
NC (normally closed) type
Descriptions
B
SAB1A
Working pressure range MPa
NO (normally open) type
0 to 0.9
B
Pilot air pressure
MPa
0.35 to 0.7
A
Double acting type B
Refer to Intro 11. -10 to 60 (no freezing) (*2)
Fluid temperature
X
0 to 1 2.0
Withstanding pressure (water) MPa
Y
Ambient temperature
-10 to 60
Valve seat leakage cm3/min
0.12 or less (with pneumatics) Free
Mounting attitude
Y
Double acting type
Air/gas (*1)
Working fluid A
SAB3A
SAB2A
NC (normally closed) type NO (normally open) type
Actuation
X
*1: Refer to working fluid check list on Intro 14. *2: Sealant fluoro rubber (FKM) is -10 to 90 .
A
Individual specifications Descriptions Model no.
Port size
Orifice (mm)
C [dm3/(s bar)] b
S (mm2)
Allowable back pressure (MPa)
Pilot port size
Weight (kg)
NC (normally closed) type SAB1A-8A
Rc1/4
10
8.3
0.4
-
SAB1A-10A
Rc3/8
10
11
0.4
-
SAB1A-15A
Rc1/2
15
-
-
120
0.6
SAB1A-20A
Rc3/4
16
-
-
150
0.8
SAB1A-25A
Rc1
20
-
-
240
1.1
SAB1A-32A
Rc1 1/4
26
-
-
390
SAB1A-32F
32 flange
26
-
-
390
SAB1A-40A
Rc1 1/2
32
-
-
610
SAB1A-40F
40 flange
32
-
-
610
6.3
SAB1A-50A
Rc2
42
-
-
920
5.2
SAB1A-50F
50 flange
42
-
-
920
9.1
SAB1A-65F (*2)
65 flange
65
-
-
1290
19.5
SAB1A-80F (*2)
80 flange
79
-
-
1840
23.5 0.3
0.3
0.5
0.3
2.2 Rc1/8 0.1
5.2 3.2
NO (normally open) type SAB2A-8A
Rc1/4
10
8.9
0.4
-
SAB2A-10A
Rc3/8
10
12
0.3
-
SAB2A-15A
Rc1/2
15
-
-
140
SAB2A-20A
Rc3/4
16
-
-
180
0.8
SAB2A-25A
Rc1
20
-
-
280
1.1
SAB2A-32A
Rc1 1/4
26
-
-
450
SAB2A-32F
32 flange
26
-
-
450
SAB2A-40A
Rc1 1/2
32
-
-
680
SAB2A-40F
40 flange
32
-
-
680
SAB2A-50A
Rc2
42
-
-
1020
SAB2A-50F
50 flange
42
-
-
1020
9.1
SAB2A-65F (*2)
65 flange
65
-
-
1290
19
SAB2A-80F (*2)
80 flange
79
-
-
1840
23
0.3 0.1
0.6
2.2 Rc1/8
5.2 3.2 6.3
0.05
5.2
Double acting type (*1) SAB3A-8A
Rc1/4
10
8.3 (8.9)
0.4
-
0.3
SAB3A-10A
Rc3/8
10
11 (12)
0.4 (0.3)
-
0.3
SAB3A-15A
Rc1/2
15
-
-
120 (140)
0.6
SAB3A-20A
Rc3/4
16
-
-
150 (180)
0.8
SAB3A-25A
Rc1
20
-
-
240 (280)
1.1
SAB3A-32A
Rc1 1/4
26
-
-
390 (450)
SAB3A-32F
32 flange
26
-
-
390 (450)
SAB3A-40A
Rc1 1/2
32
-
-
610 (680)
3.2
SAB3A-40F
40 flange
32
-
-
610 (680)
6.3
SAB3A-50A
Rc2
42
-
-
920 (1020)
5.2
SAB3A-50F
50 flange
42
-
-
920 (1020)
9.1
SAB3A-65F (*2)
65 flange
65
-
-
1290
18
SAB3A-80F (*2)
80 flange
79
-
-
1840
22
2.2 1
*1: Values given in parentheses ( ) for the double-acting type's C, b, and S values are the flow rate when port A is pressurized. *2: Port size 65 and 80 flanges are custom order. *3: Effective sectional area S and sonic conductance C are converted as S 5.0 X C.
5
Rc1/8
5.2