Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a spec sheet · part 2 of 6

Air operated 2 port valve (cylinder valve) SAB/SVB Series, pages 11 to 20

Pages 11 to 20 of 58

The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the CKD Pneumatic CVS2-15A-05-02H-1

Page 11

SAB/SVB Series When using the valve for steam, external leaks could occur depending on fluid properties. Install a steam trap by inclining piping, etc., and remove drainage to prevent the inside of the pipe from rusting. Strainer

3. Wiring CAUTION Use the product within the allowable voltage range. Use outside of the allowable voltage range may lead to operation faults or coil damage.

SAB

Steam trap

Use a breaker such as the fuse, etc., on the control circuit for maintenance of electric equipment.

Refer to the table below for tightening torque when piping. <Product/body section piping>

Nominal piping diameter

Recommended piping tightening torque (N m)

Rc1/4 Rc3/8 Rc1/2 Rc3/4 Rc1 Rc1 1/4 Rc1 1/2 Rc2

23 to 25 31 to 33 41 to 43 62 to 65 83 to 86 97 to 100 104 to 108 132 to 136

If the electrical circuit is susceptible to solenoid surge, use a solenoid with a surge suppressor (option), or insert a surge absorber, etc., parallel to the solenoid. Use a wire with nominal section area 0.5mm2 and over as the reference. Check that no excessive force is applied to leads. When using an explosion-proof solenoid valve, follow explosion-proof policy when wiring.

Refer to the table below for tightening torque of the pilot air when piping.

Use of a switching circuit that does not cause contact chatter will lengthen the life of the solenoid valve and motorized valve.

Nominal piping diameter Recommended piping tightening torque (N m)

Wiring when solenoid valve is installed.

Rc1/8

7 to 9

If a manifold is used on the SAB Series operation valve, exhaust pressure from other valves could be led in and cause malfunctions such as momentary opening of the SAB. When using a manifold, use a valve with a built-in "check valve". Similar problems could occur if exhaust is led in from the SVB Series exhaust (R) port, so when piping the exhaust (R) port, do not connect with other exhaust circuits. A check valve is built into CKD pilot 3 or 5 port valve 4G Series. Example of pneumatic pressure that could misoperate

Exhaust pressure

Exhaust pressure

Misoperation of air-operated 2-port valve

(1) Refer to connections on page 13 in the introduction when wiring to a DIN terminal box or T-type terminal box. (2) The size of the screw for the DIN terminal box's junction box outlets can be changed from Pg9 to G1/2 using the optional connector below. 25 16

Pg9

Hexagon head 24

G1/2

Model no.: CVS2-CONNECTOR-F4-202936

(3) Coil orientation is changed by 180°. Turn the coil only when reversing the electric wire connection method. Do not lose internal parts when removing the coil.

Exhaust pressure

Pneumatics system using 4G series Miss-operation prevented for air operated 2 port valve

Check valve

Exhaust pressure

Exhaust pressure

*Note that cylinder can not be operated manually with pressurized state.

Intro 10

Page 12

SAB/SVB Series During Use & Maintenance 1. Maintenance & Inspection WARNING

WARNING

To ensure that the product is used optimally, regularly inspect the product every six months. This frequency varies with the frequency of use.

CAUTION Read the instruction manual thoroughly before starting maintenance to ensure correct operation. Turn power off and release fluids or pressure before starting maintenance. Care must be taken not to clog the strainer-filter. Pilot air pressure Use pilot air pressure in accordance with specifications. Set the pilot pressure for the SAB and SVB Series NO type and double-acting type as shown in the graph below. A sealing fault could occur if pressure is set less than the range shown in the graph below. The NC model type should be selected when the pilot air cannot be controlled. W

W

SAB 23 AV /SVB2 AV Series Pilot air pressure

0.7 0.6

(MPa)

0.1

Pilot air

0.5 set pressure range

0.4 0.3 0.2 0

0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Working pressure (MPa)

SAB23 S/SVB2S Series Pilot air pressure

0.7 0.6

(MPa)

0.1

0.5 0.4 0.3 range ssure et pre s ir a t Pilo

0.2 0

0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Working pressure (MPa)

Intro 11

2. Assembling & Disassembling A spring is used in the cylinder cover. When disassembling this type, the spring could pop out and cause injuries, so take care. The NC (normally closed) has a snap ring to prevent the spring from popping out. Do not remove the snap ring.

CAUTION When cleaning the product, use a low-polluting cleaning agent such as a neutral detergent. (Note that rubber parts must be replaced if they expand.) Consult with CKD on questions about consumables, etc.

Page 13

SAB/SVB Series CAUTION Assembling pilot solenoid valve (for solenoid valve) If the pilot solenoid valve has been disassembled, assemble it as follows.

(1) Coil side Disassembling Loosen the cross headed pan head machine screw, and lift up the coil assembly. The outer spring, plunger assembly, and O ring are removed. Reassembling Set parts in the sequence of the O ring, plunger assembly, outer spring, and coil assembly. Tighten cross headed pan head machine screw with 0.7 to 1.1N m. (2) Guard side Disassembling Loosen the cross headed pan head machine screw, and remove the cover. The valve element spring, valve element guide assembly, and O ring are removed. Reassembling Set parts in the sequence of the O ring, valve element guide assembly, valve element spring, and cover. Tighten cross headed pan head machine screw with 0.7 to 1.1 N m.

Cross headed pan head machine screw

Coil assembly Note 2

Outer spring

Plunger assembly

O ring

Body assembly

Note 1: Do not lose the components such as springs during disassembly. O ring

Note 2: The coil assembly direction is changed 180゚. Loosen and change the cross-headed pan head machine screw. Valving element guide assembly

Note 3: Turbine oil is applied to the plunger as a lubricant.

Valving element spring

Guard

SVB*W/SVB*A/SVB*V Pilot solenoid valve (actuator assembly kit) model no. *1 CVSE2-ACTUATOR-0 - Rated voltage

Cross headed flat head screw

Indicate the coil option symbol in field *1.

Pilot solenoid valve (actuator assembly kit) model no. for SVB*S *1 SVB-ACTUATOR-C - Rated voltage Indicate the coil option symbol in field *1.

Gasket direction (for solenoid valve) A gasket has principles. Check the principles to assemble if disassembling was made.

Gasket

Port R

Port R

SVB1*

SVB2*

NC (normally closed) type

NO (normally open) type

Intro 12

Page 14

SAB/SVB Series How to wire terminal box DIN terminal box (Pg9) and DIN terminal box (Pg9) with indicator light (1) Use the following cabtire cable. • Code outer diameter: 4.5 to 7, nominal section area: 0.75mm2 (2) Insert the crimp terminal for copper wires into the cabtire cable's lead wire, and crimp the terminal with the designated tool. M3 terminal screws are used with the terminal box. (3) Tighten screws with the following tightening torque. • Setscrew tightening torque: 0.5 N•m • Terminal screw tightening torque: 0.5 N•m Setscrew

6 Attach the case.

Tighten with the screws.

Case Note: 180° rotation permissible

T terminal box (G1/2), T types terminal box with indicator light (G1/2) (1) Use the following cabtire cable. • Nominal section area: 0.75mm2 (2) Insert the crimp terminal for copper wires into the cabtire cable's lead wire, and crimp the terminal with the designated tool. M3 terminal screws are used with the terminal box. (3) Tighten screws with the following tightening torque. • Set screw tightening torque: 0.5 N•m • Terminal screw tightening torque: 0.5 N•m

Gasket

Cap assembly

Washer

Gasket

Free terminal screw * Bare crimp terminal for copper wire JIS C2805 R1.25-3 Fixing bracket Coil lead wire

Cap 2 Set the cap, washer, gasket and case. 7 Fix the cable with the cap. 3 Terminal caulking bare crimp terminal for copper wire

Lock nut Set screw

Terminal box

4 Gland

Voltage terminal Note: distinction not required

Crimp terminal fixing Gland Gasket Ground terminal Coil assembly

* Cable connector

Ground cable Cabtire cord JIS C3306 VCTF 0.75mm2 Outer diameter 4.5 to 7

*600V vinyl insulation vinyl cabtire cable JIS C 3312 VCT 0.75mm2

1 Lead wire sheath pealing

5 Gasket and gland coil terminal insertion

Parts marked with an asterisk (*) are not included.

Make wiring by 1 to 7 work procedures.

* The orientation of the cable lead out port is changed by removing the terminal box from the case, rotating it by 180°, then replacing the terminal box into the case.

*Changing direction of T type terminal box Change the orientation of the T-type terminal block from the default state as follows. (1) Hold the width across flats (25 width) of the T-type terminal box with a tool (monkey wrench, spanner, etc.), and loosen it by turning counterclockwise. (2) Loosen the lock nut. (3) Rotate the T-type terminal box clockwise to 15° before the required position. (4) Tighten the lock nut to the coil by hand until it is moderately tight. (5) Hold the width across flats of the T-type terminal box with a tool, and rotate it (approx. 15°) to tighten it to the required position. Note: When further tightening the terminal box to change the orientation from the default, rotate it within 1/2-turn.

Intro 13

Page 15

SAB/SVB Series Working fluid check list : Available : Limited, x: Not available : No applications *1: As a limitation, use is possible if conditions given in ( ) after the fluid name are met.

PTFE

EPDM

FKM

NBR

Stainless steel

PTFE

EPDM

Sealant

Fluid name

FKM

Bronze

Body material

NBR

Material combination a Acetylene Linseed oil Argon d Ethylene glycol The AE agent e Ozone (concentration must be low. A few ppm or less) f Gasoline (must be pure gasoline.) h Glycerin Cresol i Light oil Sodium silicate aqueous solution l Heavy oil A (FKM recommended if additive is entered.) Heavy oil B Heavy oil C Deionized water Silicone oil m Sodium hydroxide Hydrogen gas (High temperature not available. Use the air-operated type when explosion-proof measures are required.) n Liquid soap p Carbon oxide Carbonated water q Nitrogen gas s Natural gas t Kerosene P Propane gas Options per series option : Standard products : Option available

SAB1/2/3, SVB1/2 SAB1S/2S/3S, SVB1S/2S

CAUTION This checklist was prepared using CKD results. These values are for reference only, and are not guaranteed under all conditions. Test and confirm adequacy before starting use.

Intro 14

Page 16

Air operated 2 port valve (Cylinder valve)

SAB*W Series NC (normally closed) type, NO (normally open) type, double acting type Port size: Rc1/4 to Rc2, 32 to 80 flange Working fluid: Water or non-corrosive liquid

JIS symbol

Common specifications

NC (normally closed) type B

Descriptions

SAB1W

X

500 or less mm2/s

Fluid viscosity

0 to 0.7 (*2)

Working pressure range MPa NO (normally open) type Y A

0 to 1 2.0

Withstanding pressure (water) MPa

-10 to 60 (no freezing) (*3)

Fluid temperature

B

Ambient temperature

-10 to 60

Valve seat leakage cm3/min

0 (with water pressure) Free

Mounting attitude Water hammer

Double acting type

1 or less (caused by water supply law)

MPa

*1: Refer to working fluid check list on Intro 14. *2: Note that this differs with the type, so refer to the working pressure range in each model's specifications. *3: Sealant fluoro rubber (FKM) is for -10 to 90 .

B X

Double acting type

Water, non-corrosive fluid (*1)

Working fluid A

SAB3W

SAB2W

NC (normally closed) type NO (normally open) type

Actuation

Y A

Individual specifications Orifice (mm)

Cv flow factor

Rc1/4

10

2.3

Rc3/8

10

2.6

SAB*W-15A

Rc1/2

15

5.6

SAB*W-20A

Rc3/4

16

8

SAB*W-25A

Rc1

20

12

SAB*W-32A

Rc1 1/4

26

20

SAB*W-32F

32 flange

26

SAB*W-40A

Rc1 1/2

SAB*W-40F SAB*W-50A

Descriptions Model no.

Port size

SAB*W-8A SAB*W-10A

Working pressure range (MPa) Pilot air pressure (MPa) Pilot Weight (kg) NC type NO type Double act NC type NO type Double act Port size NC type NO type Double act 0.3 0.3 0 to 0.7

0 to 1

0.35 to 0.7

0.6 0.8 1.1 Rc1/8

2.3

2.2

2.2

20

5.3

5.2

5.2

32

32

3.4

3.2

3.2

40 flange

32

32

6.5

6.3

6.3

Rc2

42

50

5.5

5.2

5

SAB*W-50F

50 flange

42

50

9.4

9.1

8.9

SAB*W-65F (*2)

65 flange

65

70

20.5

19

18

SAB*W-80F (*2)

80 flange

79

100

25

23

22

0 to 0.5

0 to 1

0.25 to 0.7

*1: Refer to page 11 in the introduction for details on the pilot air pressure for NO and double-acting types. *2: Port size 65 and 80 flanges are custom order.

1

(*1)

(*1)

Page 17

SAB*W Series How to order

How to order SAB

1

W

B

15A

B

C Body/sealant material combination Working fluid

*1

D Other options

*2

(Water, liquid) Model no.

E Assembly direction

*3

Symbol

Descriptions

Actuation

A

A Actuation

1

NC (normally closed) type

2

NO (normally open) type

3

Double acting type

Port size

B B Port size

8A

Rc1/4

10A

Rc3/8

15A

Rc1/2

20A

Rc3/4

25A

Rc1

32A

Rc1 1/4

32F

32 flange

40A

Rc1 1/2

40F

40 flange

50A

Rc2

50F

50 flange

65F

65 flange (custom order)

80F

80 flange (custom order)

Body/sealant combination

C

Note on model no. selection 0 *1: Body/sealant combination symbol is O or B for port size 65F or 80F. Note that the body is made from cast iron. *2: Mounting plate (B in D ) can be installed for port size 8A to 32A. *3: Mounting plate assembly position reverse rotation (B-R in D ) is for port size 15A to 32A. *4: Clockwise viewed from above with port A facing right.

Standard

P D E

Option

B

R

<Example of model number>

D

Model: SAB A Actuation : NC (normally closed) type B Port size : Rc1/2 C Body/sealant combination : Body-bronze and sealant-fluoro rubber D Other options : Mounting plate E Assembly direction : No option

B E

Sealant Nitrile rubber

Bronze

Fluoro rubber

Bronze

Ethylene propylene diene rubber

Stainless steel

Nitrile rubber

Stainless steel

Fluoro rubber

Stainless steel

Ethylene propylene diene rubber

Other options Blank

SAB1W-15A-BB

Body Bronze

No option Mounting plate

Assembly direction Blank R

No option Mounting plate assembly position reverse rotation

Refer to the following diagram for the layout drawing. E Assembly direction

SAB (air operated type) *2/4 Symbol

B (mounting plate)

B-R *3

Direction

Without rotation

Mounting plate reverse rotation

B

A

B

A

Arrangement indicates pilot port IN.

2

Page 18

SAB*W Series Internal structure and parts list SAB1W 1

2

7

3

8

4

9

5

6

No. 1 2

Parts name Cylinder guard Piston

Material ADC12 A2017

Aluminum alloy die-casting

3

Adaptor

C3604 (SUS304)

Brass (stainless steel)

4

Piston rod Main valving

SUS304 Stainless steel NBR (FKM and EPDM) Nitrile rubber (fluoro, ethylene propylene diene) SUS304 Stainless steel CAC407 (SCS13) Bronze casting (stainless steel casting)

5 element

6 7

Body Spring

8

O ring

9

Aluminum

SWP

Piano wire

NBR (FKM and EPDM) Nitrile rubber (fluoro, ethylene propylene diene) MY packing seal NBR (FKM and EPDM) Nitrile rubber (fluoro, ethylene propylene diene)

*1: The value in parentheses is for an option. *2: For 65F and 80F, the body is made from FC250 (cast iron), while main valving element is made from FKM.

Dimensions SAB*W-8A to 50A (Rc screw-in type)

14.6

N

2-Rc1/8

10

Y

C

D

2-G

E

X

A

B F

Model no. SAB*W-8A

B

C

D

50

24

12

41.5

SAB*W-15A

71

28

14.5

SAB*W-20A

80

35

17.5

SAB*W-25A

90

43

SAB*W-32A

125

SAB*W-40A

140

SAB*W-50A

160

SAB*W-10A

3

A

E

F

G Rc1/4

N 37

71.5

32

61.5

94

43

Rc1/2

71

106.5

43

Rc3/4

38

21

81.5

120.5

53

Rc1

41.5

55

27.5

109.5

155

63

Rc1 1/4

46

61

30.5

130.5

179

77

Rc1 1/2

53

76

38

164

220

95

Rc2

61

Rc3/8

38

Page 19

SAB*W Series Dimensions, optional dimensions

Dimensions SAB*W-32F to 80F (flange type) 14.6

N

10

2-Rc1/8

Y

E

D

X

80F H

L

K

4-

19 K

L

M A

8- 19

Model no.

A

D

E

H

K

L

M

N

SAB*W-32F

170

109.5

195

135

36

100

12

46

SAB*W-40F

180

130.5

218.5

140

42

105

12

53

SAB*W-50F

180

164

259.5

155

54

120

14

61

SAB*W-65F

210

199

347.5

175

68

140

16

101

SAB*W-80F

240

214

367.5

185

82

150

16

111

Optional dimensions Mounting plate SAB*W-8A/10A-* B

Mounting plate SAB*W-15A to 32A-* B / B-R

X

9

P

8

2

20

Y

Port A

Q

6 25

2-

R

12 S

T *Drawing indicates B .

Model no.

P

Q

50

SAB*W-15A

90

62

SAB*W-20A

90

SAB*W-25A SAB*W-32A

*Use the body installation setscrews if fixed without mounting plate. (Thread size: M4 depth 8 pitch 19)

R

S

T

70

39

2.3

30

70

48.5

2.3

30

95

75

52

3.2

40

105

85

66.5

3.2

45

4

Page 20

Air operated 2 port valve (Cylinder valve)

SAB*A Series NC (normally closed) type, NO (normally open) type, double acting type Port size: Rc1/4 to Rc2, 32 to 80 flange Working fluid: Air, gas

JIS symbol

Common specifications

NC (normally closed) type

Descriptions

B

SAB1A

Working pressure range MPa

NO (normally open) type

0 to 0.9

B

Pilot air pressure

MPa

0.35 to 0.7

A

Double acting type B

Refer to Intro 11. -10 to 60 (no freezing) (*2)

Fluid temperature

X

0 to 1 2.0

Withstanding pressure (water) MPa

Y

Ambient temperature

-10 to 60

Valve seat leakage cm3/min

0.12 or less (with pneumatics) Free

Mounting attitude

Y

Double acting type

Air/gas (*1)

Working fluid A

SAB3A

SAB2A

NC (normally closed) type NO (normally open) type

Actuation

X

*1: Refer to working fluid check list on Intro 14. *2: Sealant fluoro rubber (FKM) is -10 to 90 .

A

Individual specifications Descriptions Model no.

Port size

Orifice (mm)

C [dm3/(s bar)] b

S (mm2)

Allowable back pressure (MPa)

Pilot port size

Weight (kg)

NC (normally closed) type SAB1A-8A

Rc1/4

10

8.3

0.4

-

SAB1A-10A

Rc3/8

10

11

0.4

-

SAB1A-15A

Rc1/2

15

-

-

120

0.6

SAB1A-20A

Rc3/4

16

-

-

150

0.8

SAB1A-25A

Rc1

20

-

-

240

1.1

SAB1A-32A

Rc1 1/4

26

-

-

390

SAB1A-32F

32 flange

26

-

-

390

SAB1A-40A

Rc1 1/2

32

-

-

610

SAB1A-40F

40 flange

32

-

-

610

6.3

SAB1A-50A

Rc2

42

-

-

920

5.2

SAB1A-50F

50 flange

42

-

-

920

9.1

SAB1A-65F (*2)

65 flange

65

-

-

1290

19.5

SAB1A-80F (*2)

80 flange

79

-

-

1840

23.5 0.3

0.3

0.5

0.3

2.2 Rc1/8 0.1

5.2 3.2

NO (normally open) type SAB2A-8A

Rc1/4

10

8.9

0.4

-

SAB2A-10A

Rc3/8

10

12

0.3

-

SAB2A-15A

Rc1/2

15

-

-

140

SAB2A-20A

Rc3/4

16

-

-

180

0.8

SAB2A-25A

Rc1

20

-

-

280

1.1

SAB2A-32A

Rc1 1/4

26

-

-

450

SAB2A-32F

32 flange

26

-

-

450

SAB2A-40A

Rc1 1/2

32

-

-

680

SAB2A-40F

40 flange

32

-

-

680

SAB2A-50A

Rc2

42

-

-

1020

SAB2A-50F

50 flange

42

-

-

1020

9.1

SAB2A-65F (*2)

65 flange

65

-

-

1290

19

SAB2A-80F (*2)

80 flange

79

-

-

1840

23

0.3 0.1

0.6

2.2 Rc1/8

5.2 3.2 6.3

0.05

5.2

Double acting type (*1) SAB3A-8A

Rc1/4

10

8.3 (8.9)

0.4

-

0.3

SAB3A-10A

Rc3/8

10

11 (12)

0.4 (0.3)

-

0.3

SAB3A-15A

Rc1/2

15

-

-

120 (140)

0.6

SAB3A-20A

Rc3/4

16

-

-

150 (180)

0.8

SAB3A-25A

Rc1

20

-

-

240 (280)

1.1

SAB3A-32A

Rc1 1/4

26

-

-

390 (450)

SAB3A-32F

32 flange

26

-

-

390 (450)

SAB3A-40A

Rc1 1/2

32

-

-

610 (680)

3.2

SAB3A-40F

40 flange

32

-

-

610 (680)

6.3

SAB3A-50A

Rc2

42

-

-

920 (1020)

5.2

SAB3A-50F

50 flange

42

-

-

920 (1020)

9.1

SAB3A-65F (*2)

65 flange

65

-

-

1290

18

SAB3A-80F (*2)

80 flange

79

-

-

1840

22

2.2 1

*1: Values given in parentheses ( ) for the double-acting type's C, b, and S values are the flow rate when port A is pressurized. *2: Port size 65 and 80 flanges are custom order. *3: Effective sectional area S and sonic conductance C are converted as S 5.0 X C.

5

Rc1/8