For the Cutler-Hammer 542VM PanelMate Series 500 and Eaton 542VM PanelMate Series 500

Page 81

Saving Changes If changes were made to the application, the user is prompted to save the changes before the application is closed. Œ Choose File then Save As...

• Choose a file name

Select OK to save file

Select Cancel to discard changes Tips:

9-2

•

The Configuration Software automatically prompts the user to save each open window with changes if the program is exited

•

While working on your application, run verify occassionally to check work

Saving the Configuration

Page 82

Chapter 10 Compiling the Application In this chapter, you will learn how to: •

Compile an application for downloading

Compiling the Application

10-1

Page 83

Compiling an Application for Downloading Prior to downloading to the online unit, the application must first be compiled into a file as follows: Œ Choose File then Compile or click Compile icon

Ž Select OK

• Choose a filename for the application

Tips:

10-2

•

When you compile a file, the verify function is automatically run

•

Compiling the file will create a new file which ends with the filename extension .ovb, .ova, .olb or .ola - this file is then available for transfer into an online unit

Compiling an Application

Page 84

Chapter 11 Transferring the Configuration to a PanelMate Series 500 Online Unit In this chapter, you will learn: •

How to setup your Personal Computer and PanelMate Series 500 online unit

•

How to perform the file transfer process

Transferring Configurations to a PanelMate

11-1

Page 85

PanelMate Transfer Overview This chapter explains how to transfer a configuration from a PC to a PanelMate Series 500 online unit. PanelMate requires two separate file types to operate. These files must be the proper version and loaded in the proper sequence for PanelMate to function properly. The two file types are: •

Drivers: A driver is the master program plus the PLC communication protocol.

•

Configurations: These are the operator screens that you configure. The version of these files can be the same or “older” than the version of the driver in the PanelMate.

The following is the order in which your setup should occur for proper transfer: Select PC serial port parameters Select Systems Information Select PLC Driver Select Options Select Configuration Prepare PanelMate for Transfer Start Transfer

11-2

Transferring Configurations to a PanelMate

Page 86

Starting the PanelMate Transfer Screen When you have completed a configuration and have saved and compiled it, begin the transfer process by selecting PanelMate Transfer:

Œ Select File

• Select PanelMate Transfer

Transferring Configurations to a PanelMate

11-3

Page 87

Setting up the Computer Communication Parameters The computer must be setup properly before the transfer process can begin:

Œ Click on Port Parameters • Click on and select the computer Port and the transfer Baud Rate

Tips:

11-4

•

Make sure that that the computer communication port that you select in the PanelMate Software is also set in your computer setup screen as a communication port and not a mouse port

•

Check power saving options in your computer setup screen to ensure they have been deactivated. Most laptops shut down serial ports when they enter power saving modes

Transferring Configurations to a PanelMate

Page 88

Determining PanelMate System Information The System Information option reads and displays the version of PLC driver and configuration that is currently in the PanelMate. The first transfer is normally a reading of the parameters in PanelMate so that proper communications can be verified.

Œ Select System Info

• Click on System/Configuration Info

Tips: •

PanelMate units are shipped from the factory loaded with a set of demonstration screens that can be used without having a PLC connected

•

Successfully verifying the information in a PanelMate allows you to confirm that your computer serial port and cable are properly setup

•

The information displayed on this screen is very helpful if you need to contact Cutler-Hammer IDT Customer Support for assistance

Transferring Configurations to a PanelMate

11-5

Page 89

Selecting the PLC Drivers to Transfer The next step is to transfer the PLC driver that you have used in your configuration.

Œ Click on Drivers • Click on and select the proper driver

Ž Click on Add to Operation List

Tip: •

11-6

Transferring the driver downloads the master program plus the PLC protocol.

Transferring Configurations to a PanelMate

Page 90

Selecting Options to Transfer Any special options that you have used in your configuration must next be transferred into the online unit. Options are “One Time Use” disks that enable each PanelMate to accept configurations that are using the following features: • •

A-B DH-485 PLC driver Print Option

Œ Click on Options • Click on and select the proper drive Ž Click on to confirm the option disk is valid • Click on Add to Operation List

Tips: •

The A-B AcceleratI/On, Modicon Modbus Plus, and Genius I/O cards are not software options. However, they must be installed in the PanelMate before downloading configuration screens using the appropriate drivers

Transferring Configurations to a PanelMate

11-7