Page 91

Selecting the Configuration to Transfer After all other required items have been transferred, the configuration can be transferred to the online unit.

Œ Click on Configuration • Click on, and select your configuration

Tips: •

11-8

The configuration to be transferred to an online unit must have a filename extension of .ovb, .ova, .olb or .ola. This indicates that it is a compiled configuration ready for online use. If it has not yet been compiled, a configuration will have a filename extension of .cvb, .cva, .clb or .cla.

Transferring Configurations to a PanelMate

Page 92

Preparing the PanelMate for a Transfer The PanelMate must be changed from the normal online run mode into an offline transfer mode before downloading new files. The following steps must be performed to place the PanelMate into transfer mode: • • • • • • • • •

Cycle power to the PanelMate unit Press HELP Button [Function Key 4 (F4)- see below] while cycling power Unit will go into Offline Mode and screen will display choices Select “More” [Soft Function Key 4 (SFK4) - see below] Select Transfer Mode [Soft Function Key 1 (SF1) - see below] Select “More” Select Serial Mode [Soft Function Key 1 (SFK1) - see below] Connect the Transfer Cable between the PanelMate (Port1) and the personal computer serial port. We recommend using the Transfer Cable manufactured by Cutler-Hammer IDT however, the cable diagram is available in the Users Guide. Warning: When transferring, do not connect any cable to Serial Port 1 RS422/RS485 jack as communication errors will result which may cause download errors.

Soft Function Key 1 (SFK1)

Soft Function Key 4 (SFK4)

Function Key 4 (F4) “Help Key”

Transferring Configurations to a PanelMate

11-9

Page 93

Starting the Transfer Process Begin the transfer process by clicking on “START.” The process will consist of: •

Checking communications and displaying System Parameters of the PanelMate.

•

Transfer the PLC Driver

•

Transfer the Configuration

Press Start

•

11-10

When complete, press Soft Function Key 4 (SFK4) to Exit and then Soft Function Key 1 (SFK1) to Run.

Transferring Configurations to a PanelMate

Page 94

Chapter 12 Running the PanelMate Series 500 Unit Online With the PLC In this chapter, you will learn how to: •

Start up a PanelMate Series 500 unit online with a PLC after completing all necessary file transfers

Running Online With the PLC

12-1

Page 95

Running the PanelMate Series 500 Unit Online With the PLC After the download process is complete the PanelMate needs to be placed in the on-line mode: • • •

Connect your PLC and verify the processor is in the Run Mode. Cycle power to the PanelMate unit. The PanelMate unit will come up in Online Mode.

The PanelMate performs a hardware diagnostic test and should come on-line. If the PanelMate does not come on-line properly or displays a communication error message: • • • •

Verify your configuration to ensure there are no mistakes Confirm the communication settings in the PanelMate Configuration match the settings of the PLC Confirm the PLC cable is correct Consult the error code tables in the Users Manual

NOTE: Your software is supplied with simple “Communication Startup” configurations you can use, along with an optional factory-built cable, to verify startup communication for many frequently-used PLCs. Refer to the Appendix of this Getting Started User’s Guide for further instructions. If the PanelMate is locked in the online startup mode due to an invalid configuration it can be placed back in the transfer mode by performing the following: • • • • • • •

12-2

Cycle power to the PanelMate unit Press HELP Button [Function Key 4 (F4)] while cycling power Unit will go into Offline Mode and screen will display choices Select “More” [Soft Function Key 4 (SFK4)] Select Transfer Mode [Soft Function Key 1 (SF1)] Select “More” Select Serial Mode [Soft Function Key 1 (SFK1)]

Running Online With the PLC

Page 96

Appendix In this chapter, information is provided to:

Appendix

•

Access and understand a set of communication startup configurations for many commonly-used PLCs - these startup configurations permit you to confirm PLC communications with your PanelMate 500 unit as part of your startup process

•

Access and understand two sample configurations provided with your PanelMate 500 configuration software

•

Review a list of 12 “Helpful Reminders” which could be useful as you create your configuration, transfer it to the online unit, and run with a PLC

A-1

Page 97

Communication Startup Configurations The part of the electronic operator station startup process which seems to produce the most common “stumbling blocks” is when a user first attempts to run the operator station online with a PLC. In the case of PanelMate 500, even if the configuration created by the user contains no syntax errors (it passes the “verify” process), and the correct PLC driver is resident in the PanelMate 500 online unit, some of the typical causes of problems include: • the cable from PanelMate 500 to PLC is wired incorrectly

• the communication parameters which must be set in the PLC and in PanelMate are not correctly matched (e.g. wrong baud rate, wrong PLC ID number, etc.)

• the PLC address references in the PanelMate 500 configuration were assigned to the incorrect locations in the PLC

If basic communication has been successfully established, problem #3 above can still occur due to human errors in configuring reference addresses for the PanelMate pages, or errors in programming the PLC. However, committing either of the first two errors above will make it impossible for basic communication to occur between PanelMate and PLC. As a result, to increase the likelihood of success at the first communication attempt between PanelMate 500 and the PLC, Cutler-Hammer IDT makes available the following:

A-2

• a set of “Communication Startup” files which can provide rapid verification of basic communication for many of the most common small PLC models, without even having a program running in the PLC - these configuration files are furnished on the “Examples” diskette which is supplied with the PanelMate 500 configuration software

• optionally available factory-built cables for most PLC models supported by the PLC driver software

Appendix

Page 98

Each startup configuration attempts to read a valid address which has been chosen for the particular PLC model. If the address is successfully read, the words “Communication Link Established” will appear on the screen of the PanelMate 500 online unit.

Note that the first two lines of the page confirm the PLC to which communication has been established. The example shown above is for the Cutler-Hammer D50 or D300 PLC. If communication is unsuccessful, the words “Communication Link Established” will NOT appear. In such a case, press the ALARM control button (the top left button, unless it is reassigned), to go to the alarm page for a communication error message. Before you proceed with development of a multi-page configuration, we strongly recommend that you use these tools to verify basic communication to your PLC.

Appendix

A-3

Page 99

PLC Models Covered, and How to Proceed The following are the PLC models and types of communication for which communication startup files are supplied: Allen-Bradley PLCs SLC 500 family via DH 485 communication SLC 5/03 & 5/04 via A-B RS 232 serial communication (DF1 protocol) SLC 5/04 via A-B Data Highway Plus * Micrologix PLC via A-B RS 232 serial communication (DF1 protocol) PLC 5 family via A-B RS 232 serial communication (DF1 protocol) PLC 5 family via A-B RS 422 serial communication (DF1 protocol) PLC 5 family via A-B Data Highway Plus * * available only for 4-line display online units (2-line units do not support direct connection to Data Highway Plus) Cutler-Hammer PLCs D50 or D300 via RS 485 serial communication D200 (CPU20) via RS 422 serial communication General Electric PLCs model 311 via Series 90 point-to-point serial communication (RS 232 via CMM card) model 311 via Series 90 point-to-point serial communication (RS 422 via CMM card) model 311 via Series 90 point-to-point serial communication (RS 422 via programming port)

A-4

Appendix

Page 100

If you plan to use one of the PLC models and communication approaches noted previously, we recommend that you complete these steps: 1. Examine the charts which follow, to determine the settings you will need to assign (baud rates, PLC ID numbers, etc.) in the PLC model you are using. Whenever possible, the settings are the default settings for the PLC model. Assign any settings necessary. 2. Transfer to the PanelMate 500 unit the appropriate PLC driver (near the top of each chart). Then transfer the communication startup configuration (named in the first line in each chart) for your PaneMate 500 online unit and PLC model. Note that for every configuration name (such as ABDH485), there are actually 4 online file types, corresponding to the 4 categories of online units: 2 and 4 line vacuum fluorescent or LCD display versions. The online file extensions are: name.ova name.ovb name.ola name.olb

(2-line vacuum fluorescent) (4-line vacuum fluorescent) (2-line LCD) (4-line LCD)

For example, if you are connecting your 4-line vacuum fluorescent display online unit to an A-B SLC 5/03 PLC via DH 485, you will need to transfer: - the Allen-Bradley DH 485 PLC driver - the ABDH485.OVB communication startup configuration 3. Connect the correct factory-built cable from the PanelMate 500 online unit to the PLC. (see the last line in the chart) 4. Assign both the PLC and PanelMate 500 to be in RUN mode, and verify that the PanelMate display shows “Communication Link Established”.

Appendix

A-5